A telescopic bollard drops into the ground when a vehicle needs through and rises again when the lane must close. It gives a site the control of a gate with the footprint of a bollard, and it suits an entrance that must open for staff in the morning and close behind them at night.

The order starts with the duty, not with the bollard. A lane that opens twice a day asks for a different lift from a yard where vehicles come and go all day, and a site with no mains power beside the lane asks for a different drive from a site with a supply already in place.

The lift, the keys, the pit and the drainage all sit inside one schedule, and an order that names each one plainly gets the right bollards on the right line. The rising bollards page covers the powered type in full, and our choosing HVM bollards guide works through the options.

  • ISO 22343-1Vehicle security barrier ratings
  • 1,500 kg to 30,000 kgTest vehicles, car to truck
  • Manual or poweredTwo lifts for two duties
  • 1,200 mm / 500 mmProtectUK gap cap and height floor

Where a telescopic bollard earns its place: entrances, yards and driveways

The entrance to a yard is where most telescopic bollards stand, in a line across a lane that must open for vehicles the site knows and close to vehicles it does not. The bollards drop for a delivery, a contractor or a resident, and rise again once the vehicle has passed, so the lane is open only while a vehicle the site expects is using it.

A driveway takes the same bollard in a shorter line, across a single lane where a car must pass and a stranger must not. A line of two or three bollards guards a domestic or small commercial entrance without the ground works a gate would need, and the bollards sit flush with the surface when they are down, so the lane is clear for the vehicles that belong there.

A yard with more than one entrance needs a telescopic line on each one, because a lane left open is a lane a vehicle can use. The survey should walk every entrance to the yard and mark the ones that need to open and the ones that should stay shut, so no entrance is left off the order. The warehouses and logistics sector page covers the yards the bollards guard.

Manual or powered: the lift that fits the duty

A manual telescopic bollard lifts by hand and drops by hand, with a key that locks it up and a key that locks it down. It suits a lane that opens a few times a day, where the person who opens it is the person who closes it, and it asks for no power, no motor and no cable run to the lane.

A powered telescopic bollard lifts on a motor and drops on a motor, with a reader, a fob or a remote that drives it. It suits a lane that opens many times a day, where a driver should not have to leave the vehicle to lift a bollard, and the motor, the power supply and the controls all belong on the order with the bollard.

The duty decides the lift, not the catalogue. A manual bollard on a lane that opens a hundred times a day will be left down, and a powered bollard on a lane that opens twice a week is power and money spent for nothing, so the daily cycle belongs on the order beside the lift. Our gate automation guide covers how a powered barrier is driven.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Lowering and raising: keys, readers and the daily cycle

Access control on a telescopic line decides who can lower it, and when. Staff take a key for the bollards they use every day, visitors take the intercom, and a fob or a reader suits a lane that many hands use, because a fob can be stopped when staff leave and a key cannot.

The daily cycle decides the wear. A bollard on a staff entrance that rises and falls a hundred times a day needs a drive proved for that duty, and a bollard on a service yard that moves once a week needs less, so the cycle count belongs on the order beside the rating.

A bollard that is left down is no bollard at all, so the routine should name who raises it and when. The last person through the lane raises the line behind them, and the record should show the line was checked at the end of the day. Readers, fobs and biometrics in the lane are covered in our security turnstiles guide.

The daily cycle: who lowers the bollard and who raises it again

A telescopic bollard guards the lane only while it stands up, so the daily cycle is the part of the order the site lives with. The routine names the person who lowers the line for the first delivery, the person who raises it after each vehicle has passed, and the person who checks the line at the end of the day, because a bollard that no one owns stays down. A lane used twice a day needs a different routine from a yard where vehicles pass all day long, and the order names the daily count beside the lift, so the drive is proved for the duty the lane carries. The person who lowers the line in the morning is often not the person who raises it after the last delivery, so the routine names both, and the handover between them is written down, not left to memory.

The keys to the line belong on the same list as the people who hold them, and the list names who holds a key, who holds the spare and who holds the key to the manual override. Stopping a fob takes a change on the list behind the reader, while a lost key takes a new cylinder and a new set of keys, so the routine for a lost key is written down before the first key is cut. The gate automation guide names the drive and the controls on a powered barrier, and the bollard regulations guide lists the rules the line must meet.

Time of day Who acts What the record shows
First opening The person on duty lowers the line Time, name and vehicles expected
Each delivery The line rises after each vehicle passes Line raised behind every vehicle
End of day The last person through checks the line Every bollard up and record signed
Night No one lowers the line without the key Key held by the person on duty

Left down overnight: the lane that stands open while the site sleeps

A bollard left down overnight leaves the lane open to any vehicle that comes, and the site will not know until the morning. The end of day check is the part of the routine that stops that happening, and it is done on the lane itself, not from the office, because a bollard that looks up from a distance can still sit short of its full height. A bollard that stops short of its full height, a lift that jams halfway and a lock that will not turn each go on the record the day they are found, and the pit is checked with the bollard, because grit in the pit will jam the lift as surely as a broken motor. The round follows the fire door inspection checklist, which names the checks for each visit.

Keep the routine in the handover pack beside the maintenance schedule, so the next team can see who lowers the line and who raises it again. The security bollards page names the fixed bollards beside the line, the bollard cost factors guide works through the build step by step, and the powered type is covered on the rising bollards page, with the controls that drive it.

The pit, the drainage and the ground it sits in

A telescopic bollard drops into a pit in the ground, and the pit takes concrete, drainage and a frame that holds the bollard true, so the ground works under the surface often cost as much as the bollard above it. The depth of the pit follows the rating, so a higher rating asks for deeper foundations and more concrete.

Drainage decides how long a telescopic bollard lasts. A pit that holds water corrodes the bollard from below, so the drain, the sump and the pump belong on the schedule beside the concrete, and the inspection round should look for the pit that no longer drains.

Services often run under a telescopic lane, and the pit must be dug without cutting through them. A survey maps the water, gas, power and data lines before any ground is broken, because striking one stops the work and the quote at once. What the line must meet is set out in our bollard regulations guide.

Safety and the release: what happens when the power goes

A powered telescopic bollard is a machine, and the safety devices are what make it safe to use. Loops in the road, photocells across the lane and warning lights on the approach each stop the bollard rising under a vehicle or a person, and a line without them has no proven safety at all.

When the power goes, the bollard must fail in the position the site needs, and the position is named on the schedule before the order is placed. A bollard that stays up traps vehicles inside, and a bollard that drops lets them through, so the site decides which failure it can live with.

Prove the safety devices with the bollard, as one assembly, rather than fitting them after the bollard is in the ground. A loop blind to a vehicle, a photocell set too low or a warning light no one can see each leaves the line unsafe, so the devices belong on the test report with the bollard. BS EN 12453 sets out the safety in use of power operated doors, and the road blockers guide covers the blockers that rise from the road.

A bollard that stays up traps the fire appliance outside

When the power goes, a powered telescopic bollard must fail in the position the site needs, and the position is named on the schedule before the order is placed. A bollard that stays up traps vehicles inside, and a bollard that drops lets them through, so the site decides which failure it can live with, and the decision belongs on the order beside the lift. A yard that holds a fire appliance route cannot take a bollard that stays up on power loss, because the appliance must reach the building when the power has already gone.

The manual override must work on power failure as well as on alarm, and it must be written into the order beside the motor. A release that needs power to work is no release at all, so the release is checked on the inspection round, and the person who holds the key to the override belongs on the access list with the staff who hold the keys to the bollards. The override key should sit with the person on duty, not in a drawer no one can reach, because a release no one can find in the dark is no release at all. The powered type is named in full on the rising bollards page, and the road blockers guide lists the blockers that rise from the road.

Fail position What it does Site that takes it
Stays up Lane stays shut Site that must stay shut at night
Drops down Lane opens Site with a fire appliance route
Manual override Lowered by hand Site where staff hold the key
Release on alarm Drops on alarm Site where escape comes first

Winter works on the pit before it works on the bollard

A telescopic bollard drops into a pit in the ground, and the pit is where winter does its work. Frost swells the ground round the pit, grit washes in from the lane and settles in the seals, and standing water corrodes the bollard from below, so the drain, the sump and the pump belong on the schedule beside the concrete, and the inspection round should look for the pit that no longer drains. A lift that sticks in the cold is a lane that will not open when the site needs it open.

The winter round looks for a bollard that no longer rises true, a seal that has come away and let grit into the pit, and a key or a lock that no longer turns in the cold, and each fault goes on the record the day it is found. The pit should be checked on the round with the bollard, so the round covers the pit as well as the steel above it. How a powered barrier is driven is laid out in the gate automation guide, the bollard cost factors guide puts a cost beside each step up the scale, the ratings are listed in the ISO 22343 vehicle security barriers guide, and the fixed bollards beside the line are named on the security bollards page.

Spacing, height and the line beside the gate

The gap beside a telescopic bollard and the height of the bollard both belong on the schedule, because ProtectUK guidance puts a 1,200 mm cap on the clear gap and a 500 mm floor under the height. Leave a wider gap and a vehicle slips past the line, and fit a lower bollard and a vehicle climbs it.

The fixed bollards between the telescopic ones close the line where a vehicle could slip through. They sit beside the gate post, along the wall and at the kerb where a vehicle could mount the pavement, and each one takes the same spacing and height as the telescopic bollards beside it. The security bollards page covers the fixed bollards, and our bollard cost factors guide works through what each step up the scale adds to the build.

A telescopic line beside a gate must carry the same vehicle rating as the gate, because a rated gate beside an unrated gap leaves the line open. The rating on the bollards comes from a live test, with vehicles from a 1,500 kg car to a 30,000 kg truck driven at 48, 64 or 80 km/h, and the string records the vehicle class, the speed, the angle and the penetration. The ratings in full are in our ISO 22343 vehicle security barriers guide, and the vehicle impact ratings page sets out the ratings the order should name.

Keeping the lift smooth: the inspection round for a telescopic line

A telescopic bollard moves, so it asks for more care than a fixed one. The inspection round looks for a bollard that no longer rises true, a lift that sticks, a seal that has come away and let grit into the pit, and a key or a lock that no longer turns, and each fault goes on the record the day it is found.

The pit should be checked on the round, because a pit that holds water corrodes the bollard from below and a pit full of grit stops the lift. The drain, the sump and the pump are checked with the bollard, so the round covers the pit as well as the steel above it.

What each check looks for is set out in the fire door inspection checklist, and the same discipline runs through the telescopic line: the record names the bollard, the fault, the repair and the date it was fixed, so the next team can see what was checked and what was done.

The telescopic order: one schedule for the whole entrance

Build the enquiry as a specification, with one line for every bollard on the site. Each line names the position, the rating, the lift and the drive, the keys and the access control, the pit and the drainage, and the bollard, the pit and the controls as one line.

Send the test report, the classification and the maintenance schedule with the bollards, and file them on the day they arrive. The handover pack names the inspection routine the site will follow, so the record covers the whole life of the line. The how to specify security doors guide runs through the same discipline column by column, and our security gates cost factors guide works through what each step up the line adds to the build.

Position Bollard Lift What to check
Yard entrance Telescopic bollards Powered Motor, loops, release
Driveway Telescopic bollards Manual Key, lock, socket
Service lane Telescopic bollard Powered Cycle count, drainage
Pedestrian area Fixed bollards None Spacing 1,200 mm, height 500 mm
Gate posts Fixed bollards None Same rating as the gate

A telescopic bollard opens the lane for the vehicles the site expects and closes it to the rest, so the lift, the keys, the pit and the drainage must all sit on the same schedule.

What is a telescopic bollard?

A bollard that drops into the ground when a vehicle needs through and rises again when the lane must close. It gives a site the control of a gate with the footprint of a bollard.

Manual or powered: which telescopic bollard fits?

The duty decides. A manual bollard suits a lane that opens a few times a day, and a powered bollard suits a lane that opens many times a day, where a driver should not have to leave the vehicle to lift it.

What vehicle rating do telescopic bollards need?

The vehicle the lane must stop sets it. ISO 22343-1 proves a barrier by driving a vehicle at it, from a 1,500 kg car to a 30,000 kg truck at 48, 64 or 80 km/h, and the rating names the vehicle, the speed, the angle and the penetration.

What happens to a powered telescopic bollard in a power cut?

It must fail in the position the site needs, and the position is named on the schedule before the order is placed. A bollard that stays up traps vehicles inside, and a bollard that drops lets them through.

Who checks telescopic bollards?

The site team checks them, on the routine the maintenance plan sets out. The record for each bollard names what was found, what was repaired and the date the repair was done.

Ordering this alongside other openings? The security door enquiry checklist lists what to send for each one: location, size, rating and hardware.

Specifying telescopic bollards for an entrance?Send the lane plan and the duty the line must carry for a tested bollard quotation.
Get a free quote

Related

More in guides for specifiers

10 mistakes when specifying certified security doors 10 steps to specify an LPS 1175 door Acceptance and Snagging of a Security Door or Barrier Job Access Control Doors Acoustic Doors: Ratings and Specification After a Forced Entry Attempt: Checking a Security Door Airport Security Doors Anti-Ligature Doors for Mental Health Wards Anti-Ram Bollards Anti-ram gates and barriers: protecting vehicle entrances Arcade Security Doors Explained Automatic Doors Automatic Gates Cost Factors Automatic Vehicle Barriers Ballistic Panels Bank Security Doors Bingo Hall Security Doors Explained Blast doors: glazed vs solid and how they are rated Blast protection window film: what it does and what it cannot do Blast resistant windows: what drives the cost and how to specify them Bollard Cost Factors Explained Bollard regulations in the UK: spacing, height and depth Bookmaker Security Doors Explained Builders Merchant Security Doors Bullet Resistant Glass Cost Factors Bullet resistant glass ratings explained: BR1 to BR7 and SG classes Bullet resistant vs bulletproof glass: what the difference means Buying Security Doors and HVM Through Public Frameworks Car Park Security Doors Explained Car Showroom Security Doors Casino Security Doors Explained CDM 2015 Duties When Security Doors, Shutters or HVM Are Installed Cinema Security Doors Cleanroom Doors Cold Store Doors College Security Doors Commissioning, Handover and the O&M Manual for Security Doors and HVM Communal entrance doors for flats: Secured by Design and what to specify Community Centre Security Doors Control Room Doors Court Security Doors Crash Rated Fences and HVM Fencing Explained Data centre physical security: doors, glazing, HVM and shielding by zone Dental Practice Security Doors Depot Security Doors Explained Door Entry Systems Due Diligence When Selecting Vehicle Security Barriers Emergency Exit Doors EMP Shielding Cost Factors Explained Exhibition Centre Fire Door Rules Exhibition Centre Security Doors Factory Security Doors Faraday cage vs RF shielded room: what a business needs FB4 vs FB6 vs FB7: how to choose a ballistic rating Fire and security doors: how dual certification works Fire Compartmentation Fire Curtains Fire Door Certification Fire Door Closers Explained Fire Door Cost Factors Fire Door Duties of the Accountable Person Fire Door Gaps Fire Door Hardware Explained Fire door inspection checklist for steel and timber doors Fire Door Maintenance Fire Door Regulations Care Homes Fire Door Regulations for A and E Departments Fire Door Regulations for Airports Explained Fire Door Regulations for Bowls Clubs Fire door regulations for commercial buildings in the UK Fire Door Regulations for Dialysis Centres Fire Door Regulations for Hockey Clubs Fire Door Regulations for Hospitals Explained Fire Door Regulations for Offices Explained Fire Door Regulations for Operating Theatres Fire Door Regulations for Retail Explained Fire Door Regulations for Schools Explained Fire Door Regulations for Snooker Clubs Fire Door Regulations for Stadiums Fire Door Regulations for Student Accommodation Fire Door Regulations for Warehouses Fire Door Regulations Leisure Centres Fire Door Regulations Restaurants Fire Door Remediation Programme for Housing Providers Fire Door Rules for Badminton Clubs Fire Door Rules for Bingo Halls Fire Door Rules for Bookmakers Fire Door Rules for Bowling Alleys Fire Door Rules for Car Parks Fire Door Rules for Car Showrooms Fire Door Rules for Cinemas Fire Door Rules for Climbing Centres Fire Door Rules for Colleges Fire Door Rules for Community Centres Fire Door Rules for Cricket Clubs Fire Door Rules for Dental Practices Fire Door Rules for Depots Explained Fire Door Rules for Golf Clubs Fire Door Rules for GP Surgeries Fire Door Rules for Gyms Explained Fire Door Rules for Ice Rinks Fire Door Rules for Maternity Units Fire Door Rules for Mental Health Units Fire Door Rules for Museums Fire Door Rules for Oncology Units Fire Door Rules for Opticians Fire Door Rules for Pawnbrokers Fire Door Rules for Petrol Stations Fire Door Rules for Pharmacies Fire Door Rules for Ports Fire Door Rules for Post Offices Fire Door Rules for Prisons Fire Door Rules for Rehabilitation Centres Fire Door Rules for Self Storage Fire Door Rules for Shopping Centres Fire Door Rules for Squash Clubs Fire Door Rules for Supermarkets Fire Door Rules for Swimming Pools Fire Door Rules for Tennis Clubs Fire Door Rules for Theatres Fire Door Rules for UK Arcades Fire Door Rules for UK Casinos Fire Door Rules for UK Hospices Fire Door Rules for Walk-in Centres Fire Door Signage Fire Door Vision Panels Fire Doors and Gateway 2 in Higher-Risk Buildings Fire Rated Glass Cost Explained Fire Rated Sliding Doors Explained Fire Rated Windows Cost Factors Fire Rated Windows Explained Fire Safety Enforcement Notices and Fire Doors: What the Responsible Person Must Do Flat Entrance Doors: PAS 24 and Fire Rated Forced Entry vs Ballistic vs Blast: Which Rating a Site Needs Garage Security Doors Explained Gate Automation Explained Golden Thread Records for Fire Doors GP Surgery Security Doors Explained Gym Security Doors Explained High Speed Doors HMO Fire Doors Hospice Security Doors Explained Hospital Security Doors: Wards, A&E, Plant Hospital Security Gates Hotel Fire Doors Hotel Security Doors How to choose HVM bollards: fixed, shallow mount, removable and automatic How to keep an LPS 1175 door rating valid after installation How to Specify Fire Doors in a Housing Tender How to specify security doors: a checklist for architects How to Verify a Secured by Design Listing How to Verify an LPS 1175 Certificate on Red Book Live How to Write an Operational Requirement for Physical Security HVM planters and street furniture: protection that blends in In-Service Care of Vehicle Security Barriers Installation Handover: LPS 1175 Doors and PAS 68 Barriers Intumescent Seals ISO 16933 explained: EXV and SB classes and hazard ratings ISO 22343 vehicle security barriers explained Keeping a Dual-Certified Fire and Security Door Valid in Service Laboratory Security Doors Layered Security for a Site: Deter, Detect, Delay, Mitigate, Respond Lead Times and Programme Risks for LPS 1175 Doors Leisure Centre Security Doors Library Security Doors Listed Building Fire Doors Loading Bay Doors Explained Lockdown and Access Control Hardware on an LPS 1175 Door LPS 1175 Gates and Grilles Explained LPS 1175 Issue 8 explained: from SR1 to SR8 to A1 to H20 LPS 1175 Roller Shutters LPS 1175 vs ASTM F2781 and Other US Ratings Explained LPS 1175 vs EN 1627: how UK and European burglar resistance ratings compare LPS 1175 vs PAS 24: which security standard does your door need? LPS 1175 Windows and Walling Explained Martyn’s Law and Places of Worship: What a Buyer Checks for Doors and Entry Control Martyn’s Law Enhanced Tier: Physical Measures and the Specifier Brief Martyn’s Law Standard Tier: Procedures, Doors and Shutters Martyn’s Law Timeline and the SIA Regulator Martyn’s Law: what premises must do and which physical measures to consider Master Key Systems MRI and RF shielded rooms: how they work and what to specify Museum Security Doors NPSA Catalogue of Security Equipment (CSE) Explained NPSA Forced Entry and Blast Guidance for Government Sites NPSA Guidance on Lockdown and Marauding Attack: What It Asks of Doors and Entrances Office Security Doors Optician Security Doors Explained Panic Hardware PAS 24 requirements for doors and windows explained PAS 68 Bollard Foundations Explained PAS 68 bollards: ratings, spacing and cost factors PAS 68 vs IWA 14 vs ISO 22343: hostile vehicle mitigation standards explained Pawnbroker Security Doors Explained Pedestrian Gates Petrol Station Security Doors Pharmacy Security Doors Planning Permission for Security Shutters, Gates and Bollards on Commercial Premises Plant room doors: fire, security and ventilation requirements Plant Room Fire Doors Port Security Doors Post Office Security Doors Explained Powder coating vs galvanising vs paint for steel Preliminary Market Engagement for Security Doors and HVM Prison Security Doors Programming a Security Door and Barrier Package on a Live Site Public-Sector Tender Response Checklist for Security Door and HVM Supply Reading a PAS 24 and SBD Door Test Report Regulation 38 Fire Safety Information at Handover for Fire-Rated Security Doorsets Replacing Security Doors in an Occupied Building Restaurant Security Doors Retail Security Doors Revolving Doors RF shielding standards and how shielded rooms are tested Rising Bollard Cost Factors Road Blocker Cost Factors Explained Road Blockers Explained Roller Shutter Cost Factors: What Drives the Price Roller shutter regulations in the UK: safety and maintenance Safe room and panic room doors: specification basics Safety Duties for Powered Doors, Gates and Barriers on Commercial Sites School Security Doors Sectional Doors Secured by Design explained: is it mandatory for doors? Secured by Design vs NPSA vs LPCB: Which One You Need Security Door Locks Security Door Maintenance Checklist Security Doors and Access for Everyone: What Approved Document M Asks Security Doors for A and E Departments Security Doors for Badminton Clubs Security Doors for Bowling Alleys Security Doors for Bowls Clubs Security Doors for Climbing Centres Security Doors for Cricket Clubs Security Doors for Dialysis Centres Security Doors for Golf Clubs Security Doors for Hockey Clubs Security Doors for Ice Rinks Security Doors for Maternity Units Security Doors for Mental Health Units Security Doors for Oncology Units Security Doors for Operating Theatres Security Doors for Rehabilitation Centres Security Doors for Snooker Clubs Security Doors for Squash Clubs Security Doors for Swimming Pools Security Doors for Tennis Clubs Security Doors for Walk-in Centres Security Doors West Midlands Explained Security Fencing Security Gates Cost Factors Explained Security shutters vs high performance roller doors Security shutters vs retractable grilles: which suits retail and commercial openings? Security Turnstiles Explained Security Window Film Security Windows for Schools Explained Self Storage Security Doors Server Room Doors Explained Shopping Centre Security Doors Smoke Control Doors Explained Smoke Curtains Specification Mistakes When Mixing LPS 1175, PAS 24 and SBD in One Tender SR2 vs SR3 vs SR4 security doors: choosing the right LPS 1175 level Stadium Security Doors Steel Door Frames Steel vs aluminium security doors: strength, ratings and looks Steel vs timber fire doors: which suits your building? Student Accommodation Security Doors Substation doors: security, ventilation and specification Supermarket Security Doors Tender Evaluation Criteria and Scoring for Security Doors and HVM The Scope of a Maintenance Contract for Security Doors and Barriers Theatre Security Doors Thermal and Weather Performance of External Security Doorsets Thermally broken steel security doors: U-values and certification Traffic Calming as Hostile Vehicle Mitigation Transport hub security requirements Turnstile Cost Factors Explained Turnstile vs speed gate vs security portal: choosing entrance control Types of security doors for commercial buildings University Security Doors Explained Vehicle Dynamics Assessment: What It Tells the Buyer Before a Barrier Is Specified Warehouse Security Doors Explained Warehouse Security Gates Warranty, Defects Liability and Guarantees for Security Doors and Barriers What affects the cost of a bullet resistant door What affects the cost of a high-security door in the UK Window Security Bars View all →