ArxBridge
Telescopic Bollards
Telescopic bollards: retractable bollards for entrances and yards, with manual and powered lifts, keys and access control, drainage and one schedule.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A telescopic bollard drops into the ground when a vehicle needs through and rises again when the lane must close. It gives a site the control of a gate with the footprint of a bollard, and it suits an entrance that must open for staff in the morning and close behind them at night.
The order starts with the duty, not with the bollard. A lane that opens twice a day asks for a different lift from a yard where vehicles come and go all day, and a site with no mains power beside the lane asks for a different drive from a site with a supply already in place.
The lift, the keys, the pit and the drainage all sit inside one schedule, and an order that names each one plainly gets the right bollards on the right line. The rising bollards page covers the powered type in full, and our choosing HVM bollards guide works through the options.
- ISO 22343-1Vehicle security barrier ratings
- 1,500 kg to 30,000 kgTest vehicles, car to truck
- Manual or poweredTwo lifts for two duties
- 1,200 mm / 500 mmProtectUK gap cap and height floor
Where a telescopic bollard earns its place: entrances, yards and driveways
The entrance to a yard is where most telescopic bollards stand, in a line across a lane that must open for vehicles the site knows and close to vehicles it does not. The bollards drop for a delivery, a contractor or a resident, and rise again once the vehicle has passed, so the lane is open only while a vehicle the site expects is using it.
A driveway takes the same bollard in a shorter line, across a single lane where a car must pass and a stranger must not. A line of two or three bollards guards a domestic or small commercial entrance without the ground works a gate would need, and the bollards sit flush with the surface when they are down, so the lane is clear for the vehicles that belong there.
A yard with more than one entrance needs a telescopic line on each one, because a lane left open is a lane a vehicle can use. The survey should walk every entrance to the yard and mark the ones that need to open and the ones that should stay shut, so no entrance is left off the order. The warehouses and logistics sector page covers the yards the bollards guard.
Manual or powered: the lift that fits the duty
A manual telescopic bollard lifts by hand and drops by hand, with a key that locks it up and a key that locks it down. It suits a lane that opens a few times a day, where the person who opens it is the person who closes it, and it asks for no power, no motor and no cable run to the lane.
A powered telescopic bollard lifts on a motor and drops on a motor, with a reader, a fob or a remote that drives it. It suits a lane that opens many times a day, where a driver should not have to leave the vehicle to lift a bollard, and the motor, the power supply and the controls all belong on the order with the bollard.
The duty decides the lift, not the catalogue. A manual bollard on a lane that opens a hundred times a day will be left down, and a powered bollard on a lane that opens twice a week is power and money spent for nothing, so the daily cycle belongs on the order beside the lift. Our gate automation guide covers how a powered barrier is driven.
Lowering and raising: keys, readers and the daily cycle
Access control on a telescopic line decides who can lower it, and when. Staff take a key for the bollards they use every day, visitors take the intercom, and a fob or a reader suits a lane that many hands use, because a fob can be stopped when staff leave and a key cannot.
The daily cycle decides the wear. A bollard on a staff entrance that rises and falls a hundred times a day needs a drive proved for that duty, and a bollard on a service yard that moves once a week needs less, so the cycle count belongs on the order beside the rating.
A bollard that is left down is no bollard at all, so the routine should name who raises it and when. The last person through the lane raises the line behind them, and the record should show the line was checked at the end of the day. Readers, fobs and biometrics in the lane are covered in our security turnstiles guide.
The daily cycle: who lowers the bollard and who raises it again
A telescopic bollard guards the lane only while it stands up, so the daily cycle is the part of the order the site lives with. The routine names the person who lowers the line for the first delivery, the person who raises it after each vehicle has passed, and the person who checks the line at the end of the day, because a bollard that no one owns stays down. A lane used twice a day needs a different routine from a yard where vehicles pass all day long, and the order names the daily count beside the lift, so the drive is proved for the duty the lane carries. The person who lowers the line in the morning is often not the person who raises it after the last delivery, so the routine names both, and the handover between them is written down, not left to memory.
The keys to the line belong on the same list as the people who hold them, and the list names who holds a key, who holds the spare and who holds the key to the manual override. Stopping a fob takes a change on the list behind the reader, while a lost key takes a new cylinder and a new set of keys, so the routine for a lost key is written down before the first key is cut. The gate automation guide names the drive and the controls on a powered barrier, and the bollard regulations guide lists the rules the line must meet.
| Time of day | Who acts | What the record shows |
|---|---|---|
| First opening | The person on duty lowers the line | Time, name and vehicles expected |
| Each delivery | The line rises after each vehicle passes | Line raised behind every vehicle |
| End of day | The last person through checks the line | Every bollard up and record signed |
| Night | No one lowers the line without the key | Key held by the person on duty |
Left down overnight: the lane that stands open while the site sleeps
A bollard left down overnight leaves the lane open to any vehicle that comes, and the site will not know until the morning. The end of day check is the part of the routine that stops that happening, and it is done on the lane itself, not from the office, because a bollard that looks up from a distance can still sit short of its full height. A bollard that stops short of its full height, a lift that jams halfway and a lock that will not turn each go on the record the day they are found, and the pit is checked with the bollard, because grit in the pit will jam the lift as surely as a broken motor. The round follows the fire door inspection checklist, which names the checks for each visit.
Keep the routine in the handover pack beside the maintenance schedule, so the next team can see who lowers the line and who raises it again. The security bollards page names the fixed bollards beside the line, the bollard cost factors guide works through the build step by step, and the powered type is covered on the rising bollards page, with the controls that drive it.
The pit, the drainage and the ground it sits in
A telescopic bollard drops into a pit in the ground, and the pit takes concrete, drainage and a frame that holds the bollard true, so the ground works under the surface often cost as much as the bollard above it. The depth of the pit follows the rating, so a higher rating asks for deeper foundations and more concrete.
Drainage decides how long a telescopic bollard lasts. A pit that holds water corrodes the bollard from below, so the drain, the sump and the pump belong on the schedule beside the concrete, and the inspection round should look for the pit that no longer drains.
Services often run under a telescopic lane, and the pit must be dug without cutting through them. A survey maps the water, gas, power and data lines before any ground is broken, because striking one stops the work and the quote at once. What the line must meet is set out in our bollard regulations guide.
Safety and the release: what happens when the power goes
A powered telescopic bollard is a machine, and the safety devices are what make it safe to use. Loops in the road, photocells across the lane and warning lights on the approach each stop the bollard rising under a vehicle or a person, and a line without them has no proven safety at all.
When the power goes, the bollard must fail in the position the site needs, and the position is named on the schedule before the order is placed. A bollard that stays up traps vehicles inside, and a bollard that drops lets them through, so the site decides which failure it can live with.
Prove the safety devices with the bollard, as one assembly, rather than fitting them after the bollard is in the ground. A loop blind to a vehicle, a photocell set too low or a warning light no one can see each leaves the line unsafe, so the devices belong on the test report with the bollard. BS EN 12453 sets out the safety in use of power operated doors, and the road blockers guide covers the blockers that rise from the road.
A bollard that stays up traps the fire appliance outside
When the power goes, a powered telescopic bollard must fail in the position the site needs, and the position is named on the schedule before the order is placed. A bollard that stays up traps vehicles inside, and a bollard that drops lets them through, so the site decides which failure it can live with, and the decision belongs on the order beside the lift. A yard that holds a fire appliance route cannot take a bollard that stays up on power loss, because the appliance must reach the building when the power has already gone.
The manual override must work on power failure as well as on alarm, and it must be written into the order beside the motor. A release that needs power to work is no release at all, so the release is checked on the inspection round, and the person who holds the key to the override belongs on the access list with the staff who hold the keys to the bollards. The override key should sit with the person on duty, not in a drawer no one can reach, because a release no one can find in the dark is no release at all. The powered type is named in full on the rising bollards page, and the road blockers guide lists the blockers that rise from the road.
| Fail position | What it does | Site that takes it |
|---|---|---|
| Stays up | Lane stays shut | Site that must stay shut at night |
| Drops down | Lane opens | Site with a fire appliance route |
| Manual override | Lowered by hand | Site where staff hold the key |
| Release on alarm | Drops on alarm | Site where escape comes first |
Winter works on the pit before it works on the bollard
A telescopic bollard drops into a pit in the ground, and the pit is where winter does its work. Frost swells the ground round the pit, grit washes in from the lane and settles in the seals, and standing water corrodes the bollard from below, so the drain, the sump and the pump belong on the schedule beside the concrete, and the inspection round should look for the pit that no longer drains. A lift that sticks in the cold is a lane that will not open when the site needs it open.
The winter round looks for a bollard that no longer rises true, a seal that has come away and let grit into the pit, and a key or a lock that no longer turns in the cold, and each fault goes on the record the day it is found. The pit should be checked on the round with the bollard, so the round covers the pit as well as the steel above it. How a powered barrier is driven is laid out in the gate automation guide, the bollard cost factors guide puts a cost beside each step up the scale, the ratings are listed in the ISO 22343 vehicle security barriers guide, and the fixed bollards beside the line are named on the security bollards page.
Spacing, height and the line beside the gate
The gap beside a telescopic bollard and the height of the bollard both belong on the schedule, because ProtectUK guidance puts a 1,200 mm cap on the clear gap and a 500 mm floor under the height. Leave a wider gap and a vehicle slips past the line, and fit a lower bollard and a vehicle climbs it.
The fixed bollards between the telescopic ones close the line where a vehicle could slip through. They sit beside the gate post, along the wall and at the kerb where a vehicle could mount the pavement, and each one takes the same spacing and height as the telescopic bollards beside it. The security bollards page covers the fixed bollards, and our bollard cost factors guide works through what each step up the scale adds to the build.
A telescopic line beside a gate must carry the same vehicle rating as the gate, because a rated gate beside an unrated gap leaves the line open. The rating on the bollards comes from a live test, with vehicles from a 1,500 kg car to a 30,000 kg truck driven at 48, 64 or 80 km/h, and the string records the vehicle class, the speed, the angle and the penetration. The ratings in full are in our ISO 22343 vehicle security barriers guide, and the vehicle impact ratings page sets out the ratings the order should name.
Keeping the lift smooth: the inspection round for a telescopic line
A telescopic bollard moves, so it asks for more care than a fixed one. The inspection round looks for a bollard that no longer rises true, a lift that sticks, a seal that has come away and let grit into the pit, and a key or a lock that no longer turns, and each fault goes on the record the day it is found.
The pit should be checked on the round, because a pit that holds water corrodes the bollard from below and a pit full of grit stops the lift. The drain, the sump and the pump are checked with the bollard, so the round covers the pit as well as the steel above it.
What each check looks for is set out in the fire door inspection checklist, and the same discipline runs through the telescopic line: the record names the bollard, the fault, the repair and the date it was fixed, so the next team can see what was checked and what was done.
The telescopic order: one schedule for the whole entrance
Build the enquiry as a specification, with one line for every bollard on the site. Each line names the position, the rating, the lift and the drive, the keys and the access control, the pit and the drainage, and the bollard, the pit and the controls as one line.
Send the test report, the classification and the maintenance schedule with the bollards, and file them on the day they arrive. The handover pack names the inspection routine the site will follow, so the record covers the whole life of the line. The how to specify security doors guide runs through the same discipline column by column, and our security gates cost factors guide works through what each step up the line adds to the build.
| Position | Bollard | Lift | What to check |
|---|---|---|---|
| Yard entrance | Telescopic bollards | Powered | Motor, loops, release |
| Driveway | Telescopic bollards | Manual | Key, lock, socket |
| Service lane | Telescopic bollard | Powered | Cycle count, drainage |
| Pedestrian area | Fixed bollards | None | Spacing 1,200 mm, height 500 mm |
| Gate posts | Fixed bollards | None | Same rating as the gate |
A telescopic bollard opens the lane for the vehicles the site expects and closes it to the rest, so the lift, the keys, the pit and the drainage must all sit on the same schedule.
What is a telescopic bollard?
A bollard that drops into the ground when a vehicle needs through and rises again when the lane must close. It gives a site the control of a gate with the footprint of a bollard.
Manual or powered: which telescopic bollard fits?
The duty decides. A manual bollard suits a lane that opens a few times a day, and a powered bollard suits a lane that opens many times a day, where a driver should not have to leave the vehicle to lift it.
What vehicle rating do telescopic bollards need?
The vehicle the lane must stop sets it. ISO 22343-1 proves a barrier by driving a vehicle at it, from a 1,500 kg car to a 30,000 kg truck at 48, 64 or 80 km/h, and the rating names the vehicle, the speed, the angle and the penetration.
What happens to a powered telescopic bollard in a power cut?
It must fail in the position the site needs, and the position is named on the schedule before the order is placed. A bollard that stays up traps vehicles inside, and a bollard that drops lets them through.
Who checks telescopic bollards?
The site team checks them, on the routine the maintenance plan sets out. The record for each bollard names what was found, what was repaired and the date the repair was done.
Ordering this alongside other openings? The security door enquiry checklist lists what to send for each one: location, size, rating and hardware.
Get a free quote
Related
More in guides for specifiers
Products
One supplier for the whole building envelope
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.