ArxBridge
LPS 1175 Roller Shutters
LPS 1175 roller shutters for UK warehouses, loading bays, retail units and car parks: B3, C5 and D10 ratings, curtain construction, locking and ordering checks.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
An LPS 1175 roller shutter is a steel curtain shutter tested against forced entry to LPS 1175 Issue 8. It suits openings that a hinged door cannot cover, such as a wide loading bay, a shopfront or a car park entrance, where the shutter is the main line of defence after hours.
- B3, C5, D10Ratings by tool set and minutes
- 3, 5, 10 minutesAttack time for B3, C5, D10
- Steel curtainSlats, guides and fixings tested as one set
- LPS 1175 Issue 8.2Published by LPCB, September 2024
What an LPS 1175 rating means on a roller shutter
LPS 1175 rates a product by the tools an attacker may use and the time the product must hold against them. A B3 shutter must resist category B tools for three minutes, C5 must resist category C tools for five minutes, and D10 must resist category D tools for ten minutes.
The rating covers the whole shutter as supplied, not the curtain alone. A roller shutter has a hollow barrel, side guides and a bottom bar, and an attacker will test the weakest of them. The test team attacks the curtain, the guides, the locks and the fixings in turn.
Ask for the test evidence for the exact shutter on the order, with the size named. A rating proved on a narrow shutter does not carry itself to one twice as wide, because a wider curtain flexes more and loads the guides harder.
B3, C5 and D10: the three ratings buyers name most
Most shutter orders name one of three ratings. B3 suits openings where the risk is opportunist attack with basic hand tools. C5 suits openings where an attacker may arrive with heavier hand tools and more time. D10 suits high risk openings. The table sets out each rating under the LPS 1175 standard.
| Rating | Tool set | Minutes | Typical opening |
|---|---|---|---|
| B3 | Category B: screwdrivers, pliers, hand saws | 3 | Shopfront, small store room |
| C5 | Category C: crowbars, drills, chisels | 5 | Warehouse side door, loading bay |
| D10 | Category D: sledgehammers, disc cutters, jigsaws | 10 | High risk depot, cash handling bay |
Ratings above D10 exist, running from E10 to H20, but they are rare on roller shutters because the curtain, guides and barrel must all grow heavier to meet them. A buyer who needs more than D10 on a wide opening should check whether a rated door behind the shutter serves the opening better.
Where a rated shutter earns its place
Warehouses use rated shutters on loading bays, where the opening is wide, the stock inside is valuable and the shutter stays shut overnight. The bay is often at the back of the building, out of sight of the road, so an attacker can work unseen. A C5 shutter there gives the alarm time to work.
Retail units use rated shutters on shopfronts and rear stock doors. The shopfront faces the street and must resist a quick attack in view of passers by. The rear door faces a service yard where an attacker has cover and time. Many orders name B3 for the front and C5 for the rear.
Car parks use rated shutters on vehicle entrances and pedestrian doors within the structure. A shutter on a car park entrance takes knocks from vehicles as well as attack. The rating does not cover vehicle impact, so a shutter that must also stop a vehicle needs a separate rating. The car park security doors guide covers the pedestrian doors in the same building.
Depots and self storage sites cycle their shutters many times a day. Daily use wears the guides and the lock, and wear turns a rated shutter into an unrated one over time.
The curtain, the slats and the guides: how the shutter resists attack
The curtain is made of interlocked steel slats that roll up around a barrel above the opening. Thicker slats resist cutting better, but thickness alone does not make a rating. The slats must interlock so that a pry bar cannot lift one slat out of the next, and each slat end must sit deep in its side guide.
Side guides carry the curtain and take the force of an attack on the shutter face. They must be fixed to the structure behind them, with fixing centres that match the test evidence. Guides fixed to a weak reveal, to crumbling brick or to a thin cladding panel will pull away under attack.
The barrel, the hood and the end plates matter because an attacker who cannot get through the curtain may try above it. A hood that lifts off by hand gives a way past the curtain without touching it. On a rated shutter the hood and end plates are part of the tested set.
Locking: the point where most shutters fail first
The lock is the part of a roller shutter that an attacker reaches first, and the part that fails first in testing when it is wrong for the rating. A shutter lock must hold the bottom bar to the guides or to the ground, so that the curtain cannot be lifted from below. On a wide shutter the lock should engage at two points.
Electric operation changes the locking question rather than removing it. A motor brake can hold the curtain down, but it is not a lock in the LPS 1175 sense unless the tested set includes it as the locking means. A buyer should ask whether the rating relies on the brake, on a separate mechanical lock or on both, and what happens when the power fails.
An attempted break-in leaves marks on a shutter, and the marks decide what happens next. A curtain that was levered, a guide that was prised, a lock that was cut through: each one is looked at before the shutter opens again, because a shutter that goes back into daily use with a bent slat is a shutter that has already lost part of its rating.
After the attack, the shutter is checked slat by slat before it opens again
The check starts at the bottom bar and works up, lock first, then guides, then the curtain slat by slat. The lock takes the first blow in any attack, so a lock that no longer holds the bottom bar to the guides is the first thing written down.
A slat that has been bent or lifted out of its guide is replaced, not straightened, because a straightened slat never sits deep in its guide again. The guides are checked for fixings that have pulled away from the reveal, and a guide fixed to a weak reveal will pull away under the next attack.
The keeping an LPS 1175 rating valid guide sets out what breaks a rating once a shutter is fitted, and a repair that changes the tested set belongs on that list.
Where the shutter can no longer be trusted, a rated door behind the opening may serve it better, and the shutters and grilles guide shows where a separate door fits instead.
What still holds its rating is decided by the evidence, not by how the shutter looks
A shutter can look sound and still have lost its rating, because the test covered the curtain, the guides, the fixings and the lock together. A lock swapped for one the test did not name, or a guide refixed with the wrong centres, leaves the shutter different from the one that was tested, even when the curtain still runs.
The evidence is asked for again after the repair. The test report for the exact shutter, with the size named, is checked against the parts that were fitted, and the shutter goes back into use only when the parts on site match the parts in the report.
The ratings in full sit on the LPS 1175 standard page, with B3 holding three minutes, C5 five and D10 ten, all under Issue 8.
The roller shutter regulations guide sets out the rules the shutter must meet in use, and the roller shutter cost factors guide sets out the choices that move the build from one rating to the next.
| Part checked | What is found | Repair or replace |
|---|---|---|
| Lock | Cut or forced | Replaced with the tested lock |
| Guides | Fixings pulled away | Refixed to sound structure |
| Curtain | Slat bent or lifted | Slat replaced, never straightened |
Once the repair is ordered, send the rating, the size and the parts that were changed to the LPS 1175 roller shutters quote page, so the enquiry names the shutter that was tested and the shutter that will be fitted.
Fire and security on one shutter
Some openings need a shutter that resists both fire and forced entry, and one shutter can carry both ratings only if it has been tested for both. An LPS 1175 rating says nothing about fire, and a fire rating says nothing about forced entry. A buyer who needs both must name both ratings on the order and ask for the evidence for each. The fire rated roller shutter page covers the fire side.
Where both ratings are needed, the closing behaviour needs care. A fire shutter must close on alarm, while a security shutter must stay locked shut. The order should state how the shutter closes in a fire, who can open it after it has closed, and whether the fire closure releases the security lock.
One shutter, two ratings, two sets of evidence. A shutter that claims both fire and security ratings must show test evidence for each rating on the same product, and the order must name both.
What the rating does not prove
An LPS 1175 rating does not prove that the shutter will stop a vehicle. Forced entry tools and a moving vehicle load a shutter in different ways, and a curtain that holds against a disc cutter for ten minutes may fold at once under a vehicle. An opening that needs vehicle protection needs a rating under PAS 68, IWA 14-1 or ISO 22343-1. The hostile vehicle mitigation range covers the products that carry those ratings.
The rating does not prove fire resistance either, unless the same shutter has also been tested to EN 1634-1 and classified E, EW or EI for the minutes named. A steel curtain may look fireproof, but the gaps at the guides, the barrel and the bottom bar let heat and smoke through. A buyer who needs a fire rating must name the E or EI class and the minutes.
Mistakes that weaken a rated shutter order
The most common mistake is ordering by width and height alone and leaving the rating off the order. A supplier who is not given a rating will supply a standard shutter, which looks much like a rated one from the front. The rating, the tool category and the minutes must appear on the order in words.
A second mistake is measuring the opening and forgetting the structure around it. A rated shutter needs sound reveals for its guides, headroom for the barrel and hood, and a level floor for the bottom bar. A floor that slopes leaves a gap under the bottom bar, and that gap is an opening an attacker can work on.
A third mistake is fitting a rated shutter and then cutting into it. A wicket door, a vision panel or a cable pass through a rated curtain breaks the tested set. A buyer who needs a personnel door through a shutter opening should order a separate rated door beside the shutter. The security shutters range and the shutters and grilles guide show where a separate door fits instead.
A roller shutter works from dawn to close, up in the morning, down at night, and up and down again whenever a delivery arrives. The motor lifts the curtain, the guides carry it, and the lock takes the load when the shutter is shut, and every one of those parts is worked hard through the day. The shutter still goes up and down, so nobody books a service, and the service it never gets is the service that would have caught the motor straining and the chain waiting to take over.
A missed service leaves the chain to take the load when the power fails
The motor strains first. It lifts a curtain that has grown heavier with dust and grit in the guides, and it pulls harder each morning to do the same job. A motor that strains is a motor near the end of its life, and the day it stops is the day the manual chain is reached for. The chain is the fallback, and a chain that has never been tried may be stiff, tangled or out of reach when the power fails.
The manual chain should be tried on every service, with the power off, so the person who needs it knows it works before the night it matters. A shutter that cannot be worked by hand when the power fails has lost part of its job, and the roller shutter regulations guide deals with the rules the shutter must meet in use.
The guides collect what the day drops into them. Dust, grit and small stones sit in the channel, and the curtain drags a little more each week. A repair that changes the tested set can break the rating; keeping an LPS 1175 rating valid guide names the changes that cost a fitted shutter its rating.
Nobody checks a shutter that still moves
Movement is a poor test. A shutter can run up and down with a lock that has stopped holding the bottom bar, a guide fixing that has worked loose, and a slat that has bent a fraction out of true, and the only sign is a rattle nobody stops to hear. B3 holds three minutes, C5 five and D10 ten under Issue 8, and the LPS 1175 standard page names all three ratings in full.
Where trust in the shutter has gone, a rated door set behind the opening may do the job better, and the shutters and grilles guide names the places a separate door fits, while the roller shutter cost factors guide lists the choices that shift the build between ratings.
The lock takes the load all night, so the bottom bar is looked at before the shutter is left shut, and a bar that no longer sits true in the guides is written down before the site locks up.
| Part of the day | What the shutter does | What wears |
|---|---|---|
| Dawn opening | Motor lifts the curtain | Motor strains under the load |
| Through the day | Curtain stays up in the guides | Guides collect dust and grit |
| Close | Lock takes the load | Lock and bottom bar checked last |
Book the service before the motor stops, and put the rating, the size and the changed parts on the enquiry for the LPS 1175 roller shutters quote page while the shutter still runs.
How to specify an LPS 1175 roller shutter
- Name the rating. State B3, C5 or D10, with the opening it applies to and the risk behind it.
- Measure and survey. Record the opening size, the reveal condition, the headroom and the floor level.
- Name the whole set. List the curtain, guides, fixings, barrel, hood and lock as one tested set.
- State the operation. Say whether the shutter is manual or electric, how it locks, and what happens when the power fails.
- Name any second rating. Add the fire class and minutes, or the vehicle impact rating, where the opening needs them.
- Ask for the evidence. Request the test evidence for the exact shutter, size and rating, and check it before fitting.
What does B3 mean on a roller shutter?
B3 means the shutter resisted category B tools, such as screwdrivers, pliers and hand saws, for three minutes in an LPS 1175 test. The rating covers the curtain, guides, fixings and lock as one tested set.
Is a C5 shutter enough for a loading bay?
C5 suits many loading bays, because it resists crowbars, drills and chisels for five minutes. A bay out of sight of the road, or one holding high value stock, may need D10, and the risk assessment should decide.
Can one shutter be both fire rated and LPS 1175 rated?
Yes, but only if the same shutter has been tested for both ratings. An LPS 1175 rating proves nothing about fire, and a fire rating proves nothing about forced entry, so the order must name both and the evidence must cover both.
Does an LPS 1175 shutter stop a vehicle?
No. LPS 1175 tests forced entry by hand tools, not vehicle impact. An opening that must stop a vehicle needs a PAS 68, IWA 14-1 or ISO 22343-1 rating, which states the vehicle mass, speed and penetration distance.
What should the order name besides the rating?
The order should name the opening size, the curtain, guides, fixings, barrel, hood and lock as one set, the method of operation, how the shutter locks when the power fails, and any fire or vehicle rating needed.
Ready to price a shutter? The LPS 1175 roller shutters quote page sets out the rating, size and second rating one enquiry should name.
Get a free quote
Related
More in guides for specifiers
Products
One supplier for the whole building envelope
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.