Certified physical security

ArxBridge
Installer raising a perforated steel security shutter on a UK high-street shop

ArxBridge

LPS 1175 Roller Shutters

LPS 1175 roller shutters for UK warehouses, loading bays, retail units and car parks: B3, C5 and D10 ratings, curtain construction, locking and ordering checks.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed across the UK
Prefer to talk?+44 7352 267239

Get a free project quote

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

An LPS 1175 roller shutter is a steel curtain shutter tested against forced entry to LPS 1175 Issue 8. It suits openings that a hinged door cannot cover, such as a wide loading bay, a shopfront or a car park entrance, where the shutter is the main line of defence after hours.

  • B3, C5, D10Ratings by tool set and minutes
  • 3, 5, 10 minutesAttack time for B3, C5, D10
  • Steel curtainSlats, guides and fixings tested as one set
  • LPS 1175 Issue 8.2Published by LPCB, September 2024

What an LPS 1175 rating means on a roller shutter

LPS 1175 rates a product by the tools an attacker may use and the time the product must hold against them. A B3 shutter must resist category B tools for three minutes, C5 must resist category C tools for five minutes, and D10 must resist category D tools for ten minutes.

The rating covers the whole shutter as supplied, not the curtain alone. A roller shutter has a hollow barrel, side guides and a bottom bar, and an attacker will test the weakest of them. The test team attacks the curtain, the guides, the locks and the fixings in turn.

Ask for the test evidence for the exact shutter on the order, with the size named. A rating proved on a narrow shutter does not carry itself to one twice as wide, because a wider curtain flexes more and loads the guides harder.

B3, C5 and D10: the three ratings buyers name most

Most shutter orders name one of three ratings. B3 suits openings where the risk is opportunist attack with basic hand tools. C5 suits openings where an attacker may arrive with heavier hand tools and more time. D10 suits high risk openings. The table sets out each rating under the LPS 1175 standard.

Rating Tool set Minutes Typical opening
B3 Category B: screwdrivers, pliers, hand saws 3 Shopfront, small store room
C5 Category C: crowbars, drills, chisels 5 Warehouse side door, loading bay
D10 Category D: sledgehammers, disc cutters, jigsaws 10 High risk depot, cash handling bay

Ratings above D10 exist, running from E10 to H20, but they are rare on roller shutters because the curtain, guides and barrel must all grow heavier to meet them. A buyer who needs more than D10 on a wide opening should check whether a rated door behind the shutter serves the opening better.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Where a rated shutter earns its place

Warehouses use rated shutters on loading bays, where the opening is wide, the stock inside is valuable and the shutter stays shut overnight. The bay is often at the back of the building, out of sight of the road, so an attacker can work unseen. A C5 shutter there gives the alarm time to work.

Retail units use rated shutters on shopfronts and rear stock doors. The shopfront faces the street and must resist a quick attack in view of passers by. The rear door faces a service yard where an attacker has cover and time. Many orders name B3 for the front and C5 for the rear.

Car parks use rated shutters on vehicle entrances and pedestrian doors within the structure. A shutter on a car park entrance takes knocks from vehicles as well as attack. The rating does not cover vehicle impact, so a shutter that must also stop a vehicle needs a separate rating. The car park security doors guide covers the pedestrian doors in the same building.

Depots and self storage sites cycle their shutters many times a day. Daily use wears the guides and the lock, and wear turns a rated shutter into an unrated one over time.

The curtain, the slats and the guides: how the shutter resists attack

The curtain is made of interlocked steel slats that roll up around a barrel above the opening. Thicker slats resist cutting better, but thickness alone does not make a rating. The slats must interlock so that a pry bar cannot lift one slat out of the next, and each slat end must sit deep in its side guide.

Side guides carry the curtain and take the force of an attack on the shutter face. They must be fixed to the structure behind them, with fixing centres that match the test evidence. Guides fixed to a weak reveal, to crumbling brick or to a thin cladding panel will pull away under attack.

The barrel, the hood and the end plates matter because an attacker who cannot get through the curtain may try above it. A hood that lifts off by hand gives a way past the curtain without touching it. On a rated shutter the hood and end plates are part of the tested set.

Locking: the point where most shutters fail first

The lock is the part of a roller shutter that an attacker reaches first, and the part that fails first in testing when it is wrong for the rating. A shutter lock must hold the bottom bar to the guides or to the ground, so that the curtain cannot be lifted from below. On a wide shutter the lock should engage at two points.

Electric operation changes the locking question rather than removing it. A motor brake can hold the curtain down, but it is not a lock in the LPS 1175 sense unless the tested set includes it as the locking means. A buyer should ask whether the rating relies on the brake, on a separate mechanical lock or on both, and what happens when the power fails.

An attempted break-in leaves marks on a shutter, and the marks decide what happens next. A curtain that was levered, a guide that was prised, a lock that was cut through: each one is looked at before the shutter opens again, because a shutter that goes back into daily use with a bent slat is a shutter that has already lost part of its rating.

After the attack, the shutter is checked slat by slat before it opens again

The check starts at the bottom bar and works up, lock first, then guides, then the curtain slat by slat. The lock takes the first blow in any attack, so a lock that no longer holds the bottom bar to the guides is the first thing written down.

A slat that has been bent or lifted out of its guide is replaced, not straightened, because a straightened slat never sits deep in its guide again. The guides are checked for fixings that have pulled away from the reveal, and a guide fixed to a weak reveal will pull away under the next attack.

The keeping an LPS 1175 rating valid guide sets out what breaks a rating once a shutter is fitted, and a repair that changes the tested set belongs on that list.

Where the shutter can no longer be trusted, a rated door behind the opening may serve it better, and the shutters and grilles guide shows where a separate door fits instead.

What still holds its rating is decided by the evidence, not by how the shutter looks

A shutter can look sound and still have lost its rating, because the test covered the curtain, the guides, the fixings and the lock together. A lock swapped for one the test did not name, or a guide refixed with the wrong centres, leaves the shutter different from the one that was tested, even when the curtain still runs.

The evidence is asked for again after the repair. The test report for the exact shutter, with the size named, is checked against the parts that were fitted, and the shutter goes back into use only when the parts on site match the parts in the report.

The ratings in full sit on the LPS 1175 standard page, with B3 holding three minutes, C5 five and D10 ten, all under Issue 8.

The roller shutter regulations guide sets out the rules the shutter must meet in use, and the roller shutter cost factors guide sets out the choices that move the build from one rating to the next.

Part checked What is found Repair or replace
Lock Cut or forced Replaced with the tested lock
Guides Fixings pulled away Refixed to sound structure
Curtain Slat bent or lifted Slat replaced, never straightened

Once the repair is ordered, send the rating, the size and the parts that were changed to the LPS 1175 roller shutters quote page, so the enquiry names the shutter that was tested and the shutter that will be fitted.

Fire and security on one shutter

Some openings need a shutter that resists both fire and forced entry, and one shutter can carry both ratings only if it has been tested for both. An LPS 1175 rating says nothing about fire, and a fire rating says nothing about forced entry. A buyer who needs both must name both ratings on the order and ask for the evidence for each. The fire rated roller shutter page covers the fire side.

Where both ratings are needed, the closing behaviour needs care. A fire shutter must close on alarm, while a security shutter must stay locked shut. The order should state how the shutter closes in a fire, who can open it after it has closed, and whether the fire closure releases the security lock.

One shutter, two ratings, two sets of evidence. A shutter that claims both fire and security ratings must show test evidence for each rating on the same product, and the order must name both.

What the rating does not prove

An LPS 1175 rating does not prove that the shutter will stop a vehicle. Forced entry tools and a moving vehicle load a shutter in different ways, and a curtain that holds against a disc cutter for ten minutes may fold at once under a vehicle. An opening that needs vehicle protection needs a rating under PAS 68, IWA 14-1 or ISO 22343-1. The hostile vehicle mitigation range covers the products that carry those ratings.

The rating does not prove fire resistance either, unless the same shutter has also been tested to EN 1634-1 and classified E, EW or EI for the minutes named. A steel curtain may look fireproof, but the gaps at the guides, the barrel and the bottom bar let heat and smoke through. A buyer who needs a fire rating must name the E or EI class and the minutes.

Mistakes that weaken a rated shutter order

The most common mistake is ordering by width and height alone and leaving the rating off the order. A supplier who is not given a rating will supply a standard shutter, which looks much like a rated one from the front. The rating, the tool category and the minutes must appear on the order in words.

A second mistake is measuring the opening and forgetting the structure around it. A rated shutter needs sound reveals for its guides, headroom for the barrel and hood, and a level floor for the bottom bar. A floor that slopes leaves a gap under the bottom bar, and that gap is an opening an attacker can work on.

A third mistake is fitting a rated shutter and then cutting into it. A wicket door, a vision panel or a cable pass through a rated curtain breaks the tested set. A buyer who needs a personnel door through a shutter opening should order a separate rated door beside the shutter. The security shutters range and the shutters and grilles guide show where a separate door fits instead.

A roller shutter works from dawn to close, up in the morning, down at night, and up and down again whenever a delivery arrives. The motor lifts the curtain, the guides carry it, and the lock takes the load when the shutter is shut, and every one of those parts is worked hard through the day. The shutter still goes up and down, so nobody books a service, and the service it never gets is the service that would have caught the motor straining and the chain waiting to take over.

A missed service leaves the chain to take the load when the power fails

The motor strains first. It lifts a curtain that has grown heavier with dust and grit in the guides, and it pulls harder each morning to do the same job. A motor that strains is a motor near the end of its life, and the day it stops is the day the manual chain is reached for. The chain is the fallback, and a chain that has never been tried may be stiff, tangled or out of reach when the power fails.

The manual chain should be tried on every service, with the power off, so the person who needs it knows it works before the night it matters. A shutter that cannot be worked by hand when the power fails has lost part of its job, and the roller shutter regulations guide deals with the rules the shutter must meet in use.

The guides collect what the day drops into them. Dust, grit and small stones sit in the channel, and the curtain drags a little more each week. A repair that changes the tested set can break the rating; keeping an LPS 1175 rating valid guide names the changes that cost a fitted shutter its rating.

Nobody checks a shutter that still moves

Movement is a poor test. A shutter can run up and down with a lock that has stopped holding the bottom bar, a guide fixing that has worked loose, and a slat that has bent a fraction out of true, and the only sign is a rattle nobody stops to hear. B3 holds three minutes, C5 five and D10 ten under Issue 8, and the LPS 1175 standard page names all three ratings in full.

Where trust in the shutter has gone, a rated door set behind the opening may do the job better, and the shutters and grilles guide names the places a separate door fits, while the roller shutter cost factors guide lists the choices that shift the build between ratings.

The lock takes the load all night, so the bottom bar is looked at before the shutter is left shut, and a bar that no longer sits true in the guides is written down before the site locks up.

Part of the day What the shutter does What wears
Dawn opening Motor lifts the curtain Motor strains under the load
Through the day Curtain stays up in the guides Guides collect dust and grit
Close Lock takes the load Lock and bottom bar checked last

Book the service before the motor stops, and put the rating, the size and the changed parts on the enquiry for the LPS 1175 roller shutters quote page while the shutter still runs.

How to specify an LPS 1175 roller shutter

  1. Name the rating. State B3, C5 or D10, with the opening it applies to and the risk behind it.
  2. Measure and survey. Record the opening size, the reveal condition, the headroom and the floor level.
  3. Name the whole set. List the curtain, guides, fixings, barrel, hood and lock as one tested set.
  4. State the operation. Say whether the shutter is manual or electric, how it locks, and what happens when the power fails.
  5. Name any second rating. Add the fire class and minutes, or the vehicle impact rating, where the opening needs them.
  6. Ask for the evidence. Request the test evidence for the exact shutter, size and rating, and check it before fitting.
What does B3 mean on a roller shutter?

B3 means the shutter resisted category B tools, such as screwdrivers, pliers and hand saws, for three minutes in an LPS 1175 test. The rating covers the curtain, guides, fixings and lock as one tested set.

Is a C5 shutter enough for a loading bay?

C5 suits many loading bays, because it resists crowbars, drills and chisels for five minutes. A bay out of sight of the road, or one holding high value stock, may need D10, and the risk assessment should decide.

Can one shutter be both fire rated and LPS 1175 rated?

Yes, but only if the same shutter has been tested for both ratings. An LPS 1175 rating proves nothing about fire, and a fire rating proves nothing about forced entry, so the order must name both and the evidence must cover both.

Does an LPS 1175 shutter stop a vehicle?

No. LPS 1175 tests forced entry by hand tools, not vehicle impact. An opening that must stop a vehicle needs a PAS 68, IWA 14-1 or ISO 22343-1 rating, which states the vehicle mass, speed and penetration distance.

What should the order name besides the rating?

The order should name the opening size, the curtain, guides, fixings, barrel, hood and lock as one set, the method of operation, how the shutter locks when the power fails, and any fire or vehicle rating needed.

Which rating does your opening need?Send the opening size, the risk and any fire or vehicle rating the shutter must carry.
Get a free quote

Related

More in guides for specifiers

10 mistakes when specifying certified security doors 10 steps to specify an LPS 1175 door Acceptance and Snagging of a Security Door or Barrier Job Access Control Doors Acoustic Doors: Ratings and Specification After a Forced Entry Attempt: Checking a Security Door Airport Security Doors Anti-Ligature Doors for Mental Health Wards Anti-Ram Bollards Anti-ram gates and barriers: protecting vehicle entrances Arcade Security Doors Explained Automatic Doors Automatic Gates Cost Factors Automatic Vehicle Barriers Ballistic Panels Bank Security Doors Bingo Hall Security Doors Explained Blast doors: glazed vs solid and how they are rated Blast protection window film: what it does and what it cannot do Blast resistant windows: what drives the cost and how to specify them Bollard Cost Factors Explained Bollard regulations in the UK: spacing, height and depth Bookmaker Security Doors Explained Builders Merchant Security Doors Bullet Resistant Glass Cost Factors Bullet resistant glass ratings explained: BR1 to BR7 and SG classes Bullet resistant vs bulletproof glass: what the difference means Buying Security Doors and HVM Through Public Frameworks Car Park Security Doors Explained Car Showroom Security Doors Casino Security Doors Explained CDM 2015 Duties When Security Doors, Shutters or HVM Are Installed Cinema Security Doors Cleanroom Doors Cold Store Doors College Security Doors Commissioning, Handover and the O&M Manual for Security Doors and HVM Communal entrance doors for flats: Secured by Design and what to specify Community Centre Security Doors Control Room Doors Court Security Doors Crash Rated Fences and HVM Fencing Explained Data centre physical security: doors, glazing, HVM and shielding by zone Dental Practice Security Doors Depot Security Doors Explained Door Entry Systems Due Diligence When Selecting Vehicle Security Barriers Emergency Exit Doors EMP Shielding Cost Factors Explained Exhibition Centre Fire Door Rules Exhibition Centre Security Doors Factory Security Doors Faraday cage vs RF shielded room: what a business needs FB4 vs FB6 vs FB7: how to choose a ballistic rating Fire and security doors: how dual certification works Fire Compartmentation Fire Curtains Fire Door Certification Fire Door Closers Explained Fire Door Cost Factors Fire Door Duties of the Accountable Person Fire Door Gaps Fire Door Hardware Explained Fire door inspection checklist for steel and timber doors Fire Door Maintenance Fire Door Regulations Care Homes Fire Door Regulations for A and E Departments Fire Door Regulations for Airports Explained Fire Door Regulations for Bowls Clubs Fire door regulations for commercial buildings in the UK Fire Door Regulations for Dialysis Centres Fire Door Regulations for Hockey Clubs Fire Door Regulations for Hospitals Explained Fire Door Regulations for Offices Explained Fire Door Regulations for Operating Theatres Fire Door Regulations for Retail Explained Fire Door Regulations for Schools Explained Fire Door Regulations for Snooker Clubs Fire Door Regulations for Stadiums Fire Door Regulations for Student Accommodation Fire Door Regulations for Warehouses Fire Door Regulations Leisure Centres Fire Door Regulations Restaurants Fire Door Remediation Programme for Housing Providers Fire Door Rules for Badminton Clubs Fire Door Rules for Bingo Halls Fire Door Rules for Bookmakers Fire Door Rules for Bowling Alleys Fire Door Rules for Car Parks Fire Door Rules for Car Showrooms Fire Door Rules for Cinemas Fire Door Rules for Climbing Centres Fire Door Rules for Colleges Fire Door Rules for Community Centres Fire Door Rules for Cricket Clubs Fire Door Rules for Dental Practices Fire Door Rules for Depots Explained Fire Door Rules for Golf Clubs Fire Door Rules for GP Surgeries Fire Door Rules for Gyms Explained Fire Door Rules for Ice Rinks Fire Door Rules for Maternity Units Fire Door Rules for Mental Health Units Fire Door Rules for Museums Fire Door Rules for Oncology Units Fire Door Rules for Opticians Fire Door Rules for Pawnbrokers Fire Door Rules for Petrol Stations Fire Door Rules for Pharmacies Fire Door Rules for Ports Fire Door Rules for Post Offices Fire Door Rules for Prisons Fire Door Rules for Rehabilitation Centres Fire Door Rules for Self Storage Fire Door Rules for Shopping Centres Fire Door Rules for Squash Clubs Fire Door Rules for Supermarkets Fire Door Rules for Swimming Pools Fire Door Rules for Tennis Clubs Fire Door Rules for Theatres Fire Door Rules for UK Arcades Fire Door Rules for UK Casinos Fire Door Rules for UK Hospices Fire Door Rules for Walk-in Centres Fire Door Signage Fire Door Vision Panels Fire Doors and Gateway 2 in Higher-Risk Buildings Fire Rated Glass Cost Explained Fire Rated Sliding Doors Explained Fire Rated Windows Cost Factors Fire Rated Windows Explained Fire Safety Enforcement Notices and Fire Doors: What the Responsible Person Must Do Flat Entrance Doors: PAS 24 and Fire Rated Forced Entry vs Ballistic vs Blast: Which Rating a Site Needs Garage Security Doors Explained Gate Automation Explained Golden Thread Records for Fire Doors GP Surgery Security Doors Explained Gym Security Doors Explained High Speed Doors HMO Fire Doors Hospice Security Doors Explained Hospital Security Doors: Wards, A&E, Plant Hospital Security Gates Hotel Fire Doors Hotel Security Doors How to choose HVM bollards: fixed, shallow mount, removable and automatic How to keep an LPS 1175 door rating valid after installation How to Specify Fire Doors in a Housing Tender How to specify security doors: a checklist for architects How to Verify a Secured by Design Listing How to Verify an LPS 1175 Certificate on Red Book Live How to Write an Operational Requirement for Physical Security HVM planters and street furniture: protection that blends in In-Service Care of Vehicle Security Barriers Installation Handover: LPS 1175 Doors and PAS 68 Barriers Intumescent Seals ISO 16933 explained: EXV and SB classes and hazard ratings ISO 22343 vehicle security barriers explained Keeping a Dual-Certified Fire and Security Door Valid in Service Laboratory Security Doors Layered Security for a Site: Deter, Detect, Delay, Mitigate, Respond Lead Times and Programme Risks for LPS 1175 Doors Leisure Centre Security Doors Library Security Doors Listed Building Fire Doors Loading Bay Doors Explained Lockdown and Access Control Hardware on an LPS 1175 Door LPS 1175 Gates and Grilles Explained LPS 1175 Issue 8 explained: from SR1 to SR8 to A1 to H20 LPS 1175 vs ASTM F2781 and Other US Ratings Explained LPS 1175 vs EN 1627: how UK and European burglar resistance ratings compare LPS 1175 vs PAS 24: which security standard does your door need? LPS 1175 Windows and Walling Explained Martyn’s Law and Places of Worship: What a Buyer Checks for Doors and Entry Control Martyn’s Law Enhanced Tier: Physical Measures and the Specifier Brief Martyn’s Law Standard Tier: Procedures, Doors and Shutters Martyn’s Law Timeline and the SIA Regulator Martyn’s Law: what premises must do and which physical measures to consider Master Key Systems MRI and RF shielded rooms: how they work and what to specify Museum Security Doors NPSA Catalogue of Security Equipment (CSE) Explained NPSA Forced Entry and Blast Guidance for Government Sites NPSA Guidance on Lockdown and Marauding Attack: What It Asks of Doors and Entrances Office Security Doors Optician Security Doors Explained Panic Hardware PAS 24 requirements for doors and windows explained PAS 68 Bollard Foundations Explained PAS 68 bollards: ratings, spacing and cost factors PAS 68 vs IWA 14 vs ISO 22343: hostile vehicle mitigation standards explained Pawnbroker Security Doors Explained Pedestrian Gates Petrol Station Security Doors Pharmacy Security Doors Planning Permission for Security Shutters, Gates and Bollards on Commercial Premises Plant room doors: fire, security and ventilation requirements Plant Room Fire Doors Port Security Doors Post Office Security Doors Explained Powder coating vs galvanising vs paint for steel Preliminary Market Engagement for Security Doors and HVM Prison Security Doors Programming a Security Door and Barrier Package on a Live Site Public-Sector Tender Response Checklist for Security Door and HVM Supply Reading a PAS 24 and SBD Door Test Report Regulation 38 Fire Safety Information at Handover for Fire-Rated Security Doorsets Replacing Security Doors in an Occupied Building Restaurant Security Doors Retail Security Doors Revolving Doors RF shielding standards and how shielded rooms are tested Rising Bollard Cost Factors Road Blocker Cost Factors Explained Road Blockers Explained Roller Shutter Cost Factors: What Drives the Price Roller shutter regulations in the UK: safety and maintenance Safe room and panic room doors: specification basics Safety Duties for Powered Doors, Gates and Barriers on Commercial Sites School Security Doors Sectional Doors Secured by Design explained: is it mandatory for doors? Secured by Design vs NPSA vs LPCB: Which One You Need Security Door Locks Security Door Maintenance Checklist Security Doors and Access for Everyone: What Approved Document M Asks Security Doors for A and E Departments Security Doors for Badminton Clubs Security Doors for Bowling Alleys Security Doors for Bowls Clubs Security Doors for Climbing Centres Security Doors for Cricket Clubs Security Doors for Dialysis Centres Security Doors for Golf Clubs Security Doors for Hockey Clubs Security Doors for Ice Rinks Security Doors for Maternity Units Security Doors for Mental Health Units Security Doors for Oncology Units Security Doors for Operating Theatres Security Doors for Rehabilitation Centres Security Doors for Snooker Clubs Security Doors for Squash Clubs Security Doors for Swimming Pools Security Doors for Tennis Clubs Security Doors for Walk-in Centres Security Doors West Midlands Explained Security Fencing Security Gates Cost Factors Explained Security shutters vs high performance roller doors Security shutters vs retractable grilles: which suits retail and commercial openings? Security Turnstiles Explained Security Window Film Security Windows for Schools Explained Self Storage Security Doors Server Room Doors Explained Shopping Centre Security Doors Smoke Control Doors Explained Smoke Curtains Specification Mistakes When Mixing LPS 1175, PAS 24 and SBD in One Tender SR2 vs SR3 vs SR4 security doors: choosing the right LPS 1175 level Stadium Security Doors Steel Door Frames Steel vs aluminium security doors: strength, ratings and looks Steel vs timber fire doors: which suits your building? Student Accommodation Security Doors Substation doors: security, ventilation and specification Supermarket Security Doors Telescopic Bollards Tender Evaluation Criteria and Scoring for Security Doors and HVM The Scope of a Maintenance Contract for Security Doors and Barriers Theatre Security Doors Thermal and Weather Performance of External Security Doorsets Thermally broken steel security doors: U-values and certification Traffic Calming as Hostile Vehicle Mitigation Transport hub security requirements Turnstile Cost Factors Explained Turnstile vs speed gate vs security portal: choosing entrance control Types of security doors for commercial buildings University Security Doors Explained Vehicle Dynamics Assessment: What It Tells the Buyer Before a Barrier Is Specified Warehouse Security Doors Explained Warehouse Security Gates Warranty, Defects Liability and Guarantees for Security Doors and Barriers What affects the cost of a bullet resistant door What affects the cost of a high-security door in the UK Window Security Bars View all →

Products

One supplier for the whole building envelope

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.