Details never shared
EN 1063 rates bullet resistant glass from BR1 (.22 LR) to BR7 (7.62×51 armour piercing), plus SG1 and SG2 for shotgun. BR covers the glass alone; the complete window or door takes an FB class under EN 1522. Always specify the NS suffix where people stand behind the glass.
- StandardEN 1063 tests the glazing; EN 1522 tests the finished assembly
- ClassesBR1 to BR7 for bullets, SG1 and SG2 for shotgun
- Key splitBR is the pane, FB is the window or door as built
- Safe sideNS means no fragments reach the protected face
What EN 1063 actually tests
EN 1063 tests the glazing product itself: the laminated pane, on the assumption of proper fixing. It says nothing about the frame, the beads, or the anchorage around it.
This is the most misunderstood line in bullet resistant specifications. A BR7 pane sitting in an ordinary aluminium frame is not a BR7 window. It is an expensive pane in an untested frame, and the assembly has no rating at all.
The standard also assumes the pane is installed as the manufacturer instructs: correct bite in the frame, correct gaskets, and correct edge clearance. Shortcuts at the glazing stage can undo a certified pane, which is why installation belongs in the same conversation as specification.
The full class table: BR1 to BR7, SG1 and SG2
Each class names the ammunition the glazing must stop. The classes run in order of increasing severity, so a higher class also covers the weapons of the lower ones. The shotgun classes sit apart: they cover a different threat and do not automatically follow the numbered sequence.
| Class | Ammunition |
|---|---|
| BR1 | .22 LR |
| BR2 | 9mm |
| BR3 | .357 Magnum |
| BR4 | .357 Magnum and .44 Magnum |
| BR5 | 5.56×45 rifle |
| BR6 | 5.56×45 and 7.62×51 rifle |
| BR7 | 7.62×51 hard core (armour piercing) |
| SG1 | Shotgun |
| SG2 | Shotgun |
Note the step from BR4 to BR5. This is where handguns give way to rifles, and the construction of the pane changes with it. The S or NS suffix is recorded separately and is covered below.
Read the class as a minimum, not a target. A BR4 pane has defeated everything up to .44 Magnum in the laboratory, which is why higher classes automatically cover lower threats. The only classes that stand apart are SG1 and SG2, which address shotgun specifically.
When a tender names a class, mirror it exactly in the order: standard, class, suffix. “BR6” on the tender and “BR6 NS” on the order is a mismatch that can fail an audit, so write “EN 1063 BR6 NS” in full everywhere.
BR against FB: the pane against the finished assembly
BR classes describe the glass. FB classes describe the finished product: the bullet resistant window or door with its leaf, frame, glazing, hardware, and fixings, all tested together under EN 1522.
This changes how you write the order. “BR6 glass” is an incomplete specification for a window; the finished unit needs an FB6 classification, with the BR6 pane as one component of the tested assembly. Ask for the EN 1522 evidence for the unit, not just the EN 1063 evidence for the glass. Our ballistic ratings guide explains how the two standards work together.
Curtain walling makes the distinction visible. A glazed screen can carry BR6 panes in every light and still have no FB classification until the mullions, transoms, and fixings are tested with them. Treat the screen as an assembly from the first sketch, not as glass plus framing.
S and NS: what happens on the safe side
After the shots are fired, the laboratory inspects the protected face. If fragments are ejected toward the people behind the glass, the classification carries the suffix S, for splinters. If the pane holds every fragment, it carries NS, for no splinters.
Specify NS wherever people sit or stand close behind the glazing: bank counters, ticket windows, reception screens, and guard posts. The difference is built into the pane, so it must be chosen before manufacture, not after. Our FB4 vs FB6 vs FB7 guide shows how the suffix fits into the wider class selection.
Retrofit counters deserve special care. An NS pane set into a timber screen that was never tested as an assembly gives the staff a false sense of security. The screen around the glass needs the same evidence as the glass itself.
How the laminated build-up grows with each class
Bullet resistant glass is a sandwich: multiple layers of glass bonded with interlayers that catch the bullet and hold the fragments. Each step up the classes adds layers, and the pane gets thicker and heavier.
Weight is what you feel on site. A high-class pane needs a deeper frame, stronger beads, and careful handling; large sizes may need mechanical lifting and a frame designed for the load from the start. Blast rated glazing answers a different threat under a different standard; our guide to blast resistant windows explains what drives its cost.
Never select by thickness alone. Two panes of the same thickness can carry different classes, because the rating comes from the test, not the millimetres. Buy the test evidence, not the dimension.
Spall behaviour is designed into the build-up: the layers on the protected face are there to catch fragments, which is why the NS suffix and the class are specified together and never as alternatives.
Specify the suffix every time. A class without S or NS is incomplete, because two panes at the same class can behave very differently on the protected face. Write “EN 1063 BR6 NS” in full on every order.
How to check the test evidence before you order
Ask the supplier for the test report that states the standard, the class, and the suffix: for example, EN 1063 BR6 NS. Check that the report describes the exact glass build you are buying, not a thinner or older version of it.
Then ask for the second document: the EN 1522 evidence for the finished window or door. The glass certificate never covers the assembly, and the assembly certificate is meaningless without the glass details inside it.
Treat vague wording as a warning. “Tested to EN 1063” without a class, or a class without a report you can read, is marketing, not evidence. A proper supplier produces both documents before you place the order. The banking sector pages show where these checks matter most, and the guides hub collects the wider specification library.
Keep the documents with the building. Future alterations, insurance reviews, and security audits will all ask what class is installed and where the evidence sits. A short schedule matching each opening to its test report saves that work later.
BR1 to BR7 on one schedule: matching the class to the threat
EN 1063 tests a pane of glass against shots fired at it, and the class it earns names the threat it stopped. The scale runs from BR1 to BR7, and each step up the scale is proved against a heavier round at a set distance, so the class on the order should match the threat the room faces, not the highest class on the list.
The lower end of the scale covers handgun rounds, and the upper end covers rifle rounds, with the build-up growing thicker and heavier at each step. A pane proved to BR7 carries far more layers than a pane proved to BR1, and the frame, the fixings and the wall behind it must carry that weight, or the rating on the glass means nothing on its own.
SG1 and SG2 cover shotgun pellets, and the letters after the number say what the test measured. S means splinters reach the safe side, and NS means none do, so a pane that guards people standing behind it needs NS beside the class, while a pane that guards stock alone may not.
BR names the glass, and FB names the finished assembly. EN 1522 and EN 1523 set the FB classes, FB1 to FB7, for windows, doors and shutters, with FSG for shotgun resistance, and the FB proof covers the pane, the frame and the fixings together. A BR pane set in a frame never tested with it has no FB rating, so the order should name the FB class beside the BR class, and ask for the test report on the assembly that will be fitted. Our choosing a ballistic rating guide sets out how the two scales sit together, and our bullet-resistant versus bulletproof glass guide clears up the names.
Spall control and the safe side: what S and NS add to the order
A pane that stops a round can still throw splinters off its safe side, and those splinters decide whether the people behind the glass stay safe. EN 1063 marks that with S or NS after the class, and the mark belongs on the schedule beside the class, because a pane ordered without it may stop the round and still fail the room.
The same pane may also have to stand up to a hand tool. EN 356 grades that attack from P1A to P8B, and the top three classes are set by axe blows: P6B takes 30 to 50, P7B takes 51 to 70, and P8B takes 70 or more. A pane that needs both proofs needs both test reports, one for the bullet and one for the axe, and the order should name both classes on the same line.
UL 752 runs a separate scale, Levels 1 to 10, and it covers ballistic resistance only. A level on that scale is not a stack of the levels below it, so a specification that asks for the highest level on the list has asked for more than the threat needs, and the order should name the level the threat asks for. Our ballistic ratings page sets out the scales side by side, and the bullet-resistant glass cost guide works through what each step up the scale adds to the build.
| Class | Threat it is proved against | What the order names |
|---|---|---|
| BR1 to BR2 | Handgun rounds | Class, S or NS, pane size |
| BR3 to BR4 | Heavy handgun rounds | Class, S or NS, pane size |
| BR5 to BR7 | Rifle rounds | Class, S or NS, frame and fixings |
| SG1 to SG2 | Shotgun pellets | Class, S or NS, pane size |
Keep the test report and the schedule in one file, with the class, the S or NS mark and the frame named on the same line, so the next person to read the order can see what was proved and what holds it.
Frequently asked questions
Is BR6 glass enough for an FB6 window?
It is one component of it. The finished window still needs its own FB6 test evidence as a complete assembly, frame and fixings included.
What is the difference between SG1 and SG2?
Both are EN 1063 shotgun classes. The test report states which one the pane achieved, so specify the class shown on the report rather than guessing between the two.
Do I need NS for a bank counter?
Yes, wherever staff sit close behind the glass. NS means no fragments reach the protected face, which is exactly what a counter position needs.
Can BR glass go into a standard frame?
Not as a rated assembly. The frame, beads, and fixings must be part of the tested system, or the installation has no classification.
Does thicker glass always mean a higher class?
Not necessarily. The class comes from the test result, not the dimension, and two panes of similar thickness can hold different classes.
Can one pane carry both a BR class and a blast rating?
Only if it has been tested for both. Ballistic and blast standards measure different things, and a BR certificate says nothing about blast performance.