Fire Door Rules for Tennis Clubs
Tennis clubs keep a clubhouse, a bar and locker rooms beside courts open into the evening, so each door takes the fire period its room asks for, FD30 or FD60.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A tennis club holds a clubhouse, a bar, locker rooms and a pro shop beside the courts, and the fire rules follow the rooms behind each leaf. Players eat in the bar, change in the locker rooms and buy kit in the pro shop, while the kitchen, the back office and the plant room sit behind leaves players never pass. Players leave in the dark after the last set, so the leaves on the way out matter as much as the leaves that hold flame back.
EN 1634-1 gives the minutes on a club leaf, testing it against fire and counting how long it holds. A leaf marked FD30 holds for thirty minutes and a leaf marked FD60 for sixty. What the leaf stopped is named by the letter after the minutes, E for flame on its own, EW for flame with part of the heat, and EI for flame with the heat as well.
A tennis club differs from a golf club in what sits round the clubhouse, because courts take the place of fairways, and it differs from a cricket club because the courts and the clubhouse take the place of a pavilion and a kit store. A leisure centre differs again, because sports halls and pools take the place of courts and a bar. Leaves in a building full of sports halls take their rules from the fire door rules for leisure centres, and the rooms a hall of lanes keeps behind its public floor take theirs from the fire door rules for bowling alleys.
- FD30 / FD60Periods to EN 1634-1
- Bar and locker roomsWhere players eat and change
- Sa / S200Smoke ratings from BS EN 1634-3
- One listEvery club door named
Seven openings in a tennis club: a period beside each room
Seven openings make up the club order, and the period on each one follows what its room holds. Players come in through the clubhouse entrance, buy kit in the pro shop, eat and drink in the bar and change in the locker rooms, while the kitchen holds the food stores and the back office holds the records.
The kitchen, the back office and the plant room take FD60, because the food stores, the records and the plant behind them ask for sixty minutes. The clubhouse entrance, the pro shop, the bar and the locker rooms take FD30, because the players on that route can reach the car park in less than thirty minutes.
Each opening takes a line of its own with the leaf and the period written beside the room, and the table below sets the seven rooms beside their periods and grades.
| Room | Period | Grade | What to check |
|---|---|---|---|
| Clubhouse entrance | FD30 | B3 | Leaf, glass, closer |
| Pro shop | FD30 | B3 | Leaf, glass, closer |
| Bar | FD30 | B3 | Leaf, lock, closer |
| Locker rooms | FD30 | B3 | Leaf, lock, seals |
| Kitchen | FD60 | C5 | Leaf, lock, seals |
| Back office | FD60 | C5 | Leaf, lock, seals |
| Plant room | FD60 | C5 | Leaf, lock, seals |
A doorset can carry fire minutes from EN 1634-1 beside a forced entry grade from LPS 1175 Issue 8.2 of September 2024, so one report names both proofs for the same leaf. The dual certification guide for fire and security doors shows how the two proofs are put on one leaf.
Sixty minutes behind shut leaves: FD60 in the kitchen, back office and plant room
A period is proved on the whole doorset, not on the leaf alone, so the leaf, the frame, the fixings and the lock are tested together. What the report behind a period must hold is named in the fire door certification guide.
FD60 sits on the kitchen leaf, which stays shut between services, because the food stores and the cold room behind it are what the bar sells through the evening. Sixty minutes is the hold that room asks for, because flame reaching it takes the stores the club cannot serve without.
The back office leaf takes FD60 as well, because the membership records and the keys behind it are what the club runs on, and the plant room leaf takes FD60 because the pumps and boards behind it feed the whole building. What the plant room leaves must do is set out in the plant room fire doors guide, and the doors that guard the plant are named in the plant room door requirements guide.
Thirty minutes on the way out: FD30 from courts to car park
FD30 sits on the clubhouse entrance leaf, the locker room leaves, the bar leaf and the pro shop leaf, because players change, eat, drink and buy kit before they reach the car park through the entrance. Thirty minutes is more than the players need, and the route to the car park is short.
Where players leave together after the last set, a push bar proved to BS EN 1125 sits on each leaf on the way out, because more than 60 people may crowd the route at once, and the bar spans no less than 60 percent of the leaf. The panic hardware guide sets out what the bar must do when players push against it, and the emergency exit doors guide covers the leaves on the way out.
A glazed panel in the bar leaf lets staff watch the players without opening the leaf, and the pane is proved with the leaf round it, glass, bead and fixings named in the report. Which panels a fire leaf may carry is named in the fire door vision panels guide.
Smoke before flame: Sa and S200 on the route past the locker rooms
Players leaving the courts meet smoke before they meet flame, so the leaves on the way out carry a smoke rating beside the period. Smoke ratings come from BS EN 1634-3, with Sa covering smoke at room temperature and S200 covering smoke at 200 degrees, and the smoke control doors guide works through how the route leaves keep smoke back.
A leaf that stands open through the day hangs on a hold-open device proved to BS EN 1155, which lets the leaf go on its own the moment the alarm sounds. The fire compartmentation guide names how the leaves hold the line between one part of the club and the next, and a chair wedged under a leaf leaves it with no period while it stands open.
Smoke spreads along a corridor faster than players walk with kit bags, so the leaves between the locker rooms and the entrance matter most. A leaf that shuts on its own behind each person through keeps the smoke on one side of it.
Closers, seals and gaps on tennis club doors: what the period rests on
An FD60 leaf keeps its hour only when the closer shuts it, the seals meet the frame and the gaps stay narrow, because flame slips through a leaf left ajar in seconds and through a wide gap soon after. Closer power to BS EN 1154 runs from EN 1, the smallest size, up to the larger sizes, and a closer on a fire door is never below EN 3.
The seal in the groove swells shut once the heat passes 200 degrees and keeps swelling through to around 250 degrees, while paint on the seal keeps it from growing. A gauge checks the 4 mm gap round each hung leaf, and a wider gap lets flame through sooner than the period allows. How the seal is fitted is covered in the intumescent seals guide, what the closer must do is covered in the fire door closers guide, and how the gaps are measured is covered in the fire door gaps guide.
A hinge proved to BS EN 1935 is tested through 200,000 cycles, with grade 13 rated for 120 kg and grade 14 for 160 kg, so the heavier leaf hangs on the heavier hinge. BS 8300 with Approved Document M puts the push below 30 N for the first 30 degrees of the swing and below 22.5 N beyond that point. Which signs each leaf must carry is named in the fire door signage guide.
Getting players out after dark: the courtside route to the car park
The route to the car park is signed at every turn, because the alarm may sound while a visitor who has never used the building sits in the bar. The route stays clear day and night, and the entrance leaf opens to one push from whoever reaches it first, whether the power is on or off.
Martyn’s Law received Royal Assent in April 2025 and is expected to go live in spring 2027, with a lower tier for premises holding 200 to 799 people and a higher tier from 800 people upward. What each tier asks for is set out in the Martyns Law guide for premises.
ProtectUK sets the clear gap between bollards at no more than 1,200 mm and their height at no less than 500 mm, so the line beside the car park keeps vehicles clear of the way in. Which bollards to choose is covered in the choosing HVM bollards guide.
The bar leaf and the locker room leaves: FD30 where players eat, drink and change
The bar leaf takes FD30, because players eat and drink in the bar between sets and the route out runs through it. Thirty minutes is the hold that room asks for, because the bar clears fast once the alarm sounds.
The locker room leaves take FD30 as well, because players change there between sets and the rooms must stay shut between uses. A player hurt on court is carried out through the locker room leaves, so the leaves on that short route matter as much as the leaves on the way out.
A bar in a restaurant asks for the same period on its leaves, as the fire door rules for restaurants show.
Placing the tennis club fire door order: period, grade and proof on one line
The order gives every opening a line of its own, with the leaf, the period, the lock and the closer written beside the room. A leaf named once for the whole club leaves the fitter to guess.
Every leaf on the order is checked before the order is signed, because a closer ordered after the doorset arrives holds the job up, and a leaf with no line beside it cannot be checked on arrival. What the order must hold is named in the how to specify security doors guide.
Once the club opens, the manager goes round with the door list and tries each leaf in turn. A dragging leaf, a closer that holds a leaf ajar, and a seal that has lifted from its groove are marked beside their own rooms before the first session starts. The faults to watch for on the round are set out in the fire door inspection checklist, and the routine that keeps each leaf shutting flat against its frame is covered in the fire door maintenance guide.
Put the period, the grade and the closer on one line for each leaf, and match the line to the room before any leaf goes in.
What period should a tennis club plant room door carry?
FD60 to EN 1634-1, because the plant room holds the pumps and boards and an hour is the hold that room demands.
What period should a tennis club entrance door carry?
FD30 to EN 1634-1, because players leave through the entrance and the walk to the car park takes less than half an hour.
Can a tennis club leaf hold a fire period and a security grade?
Yes, a single doorset can be proved for fire and for forced entry together, so one report states both figures for that leaf.
Do tennis club fire doors need a smoke rating?
Yes, the leaves on the route carry Sa or S200 to BS EN 1634-3 beside their period.
What happens when a fire door will not shut?
A leaf that will not shut is written up against its own door the day the fault is found.