An optician keeps consulting rooms, patient records and designer frames behind doors that open all day, so each leaf takes the grade its room demands.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
An optician is a shopfront, a waiting room and a set of consulting rooms behind one entrance, and the doors between them carry different grades because the rooms behind them hold different things. The grade on each leaf follows what sits behind it and who walks past it through the day.
The grades come from LPS 1175 Issue 8.2 of September 2024, and the three grades in an optician are B3, C5 and D10. B3 holds for three minutes, C5 holds for five minutes and D10 holds for ten minutes, and the minutes name how long the leaf resists the tools named in the test. Drawings made before Issue 8 name the same three grades SR2, SR3 and SR4, so the order puts the old name next to the new grade for the fitter who reads the drawings.
An optician is a small clinic, so the hospital security doors guide shows how larger healthcare buildings grade their doors, and the security doors for dental practices guide shows how a practice with the same mix of consulting rooms, records and stock grades its leaves.
- B3 / C5 / D10Grades to LPS 1175 Issue 8.2
- Consulting roomsWhere C5 sits in the practice
- Frames storeWhere D10 sits in the practice
- One listEvery optician door named
Six rooms behind one shopfront: where each grade sits
Six rooms make up an optician, and the grade follows what each room holds. The entrance takes the patients in from the street, the consulting rooms hold the sight tests, the records room holds the patient files, the frames store holds the designer stock, the back office holds the keys and the takings, and the plant room keeps the building running through the working day.
The entrance leaf takes B3, because the leaf stands in view of the street and the waiting room all day and must resist a quick attempt while the practice is open. The consulting rooms, the records room, the back office and the plant room take C5, because the people, the files and the keys behind those leaves need a longer hold than the entrance. The frames store takes D10, because the stock behind it is the most valuable thing in the building and it sits behind a leaf that is shut and locked whenever no one is choosing frames.
The order is written from a list that names every opening, the leaf it takes and the grade beside it, because a leaf with no line on the list may turn up in the wrong consulting room, and a leaf in the wrong room holds for the wrong number of minutes. The table below names the six rooms, the grade each one takes and the minutes behind the grade, so the fitter can check each leaf against its line as it is hung.
| Room | Grade | Minutes | What to check |
|---|---|---|---|
| Entrance | B3 | 3 | Leaf, lock, closer |
| Consulting rooms | C5 | 5 | Leaf, lock, seals |
| Records room | C5 | 5 | Leaf, lock, seals |
| Frames store | D10 | 10 | Leaf, lock, hinges |
| Back office | C5 | 5 | Leaf, lock, seals |
| Plant room | C5 | 5 | Leaf, lock, seals |
The entrance leaf: patients in, frames in view, grade B3
The entrance is the only leaf the public uses, and it opens and shuts for every patient through the day, so its closer must bring it home after each person through without a slam that startles the waiting room. The leaf is glazed so the staff at the desk can see who is coming in, and the pane is proved with the leaf round it rather than alone, because a pane that falls from its beads leaves the entrance open to the street.
A B3 leaf at the entrance resists a quick attempt with the hand tools named in the test for three minutes, which is the hold the practice needs while the staff at the desk can see the door and call for help. The lock on the entrance leaf is a cylinder that takes a key from outside and a thumb turn from inside, so the staff can lock the practice at closing without searching for a key while the last patient is still in a consulting room.
Consulting rooms: sight tests behind a C5 leaf
A consulting room is a small dark room where a patient sits close to the optometrist and the equipment round them is delicate, so the leaf must shut quietly and stay shut while the test runs. C5 suits the consulting room leaf, because the room holds the patient, the records on the screen and the instruments, and five minutes is the hold the practice asks for on a room where a stranger should not walk in unannounced.
The lock on a consulting room leaf is a privacy lock that the optometrist can set from inside and the staff can open from outside with a coin turn in an emergency, so a patient who feels unwell is never locked in with no way for help to reach them. The office security doors guide takes the same care with the doors of rooms where people work alone behind a shut leaf, and the fire door regulations dental practices guide takes it with the consulting rooms of a dental practice.
The records room and the back office: paper, screens and keys
The records room holds the patient files, and the back office holds the keys, the takings and the screens that carry the appointment book, so both leaves take C5 and both are locked whenever the room stands empty. A records room leaf that stands open through the day is no better than a leaf with no grade at all, because the files behind it can be read by anyone who walks past the open doorway.
The records room and the back office share one key system, so the practice manager holds a key that opens both leaves and the staff hold keys that open only the rooms their work needs. The master key systems guide shows how a key plan is drawn so no key opens a room its holder has no reason to enter, and the security door locks guide shows what the lock on each leaf must do.
The frames store: designer stock behind the D10 leaf
The frames store holds the designer frames that are the most valuable stock in the building, and it is the one room in the practice that is shut and locked for most of the day, so its leaf takes D10. Ten minutes is the longest hold in the practice, and it is the hold the store needs because the stock behind the leaf is small, light and easy to carry out in a bag if the leaf gives way.
The frames store leaf is a solid steel leaf with no glazed panel, because a panel in the store leaf would show the stock to anyone in the corridor and would give a hand a way through the leaf. The hinges on the store leaf are BS EN 1935 grade 13 for 200,000 cycles at 120 kg, or grade 14 for 200,000 cycles at 160 kg where the leaf is heavy, because a hinge that wears loose lets the leaf drop and the lock bolt miss its keep.
Locks, keys and the day the practice stays open
The lock on each leaf must match the grade of the leaf, because a C5 leaf with a weak cylinder is a C5 leaf in name only and the test report for the doorset names the lock that was proved with it. TS 007 puts a 1 star cylinder with a 2 star handle together to make a 3 star set, and the cylinder and the handle are ordered as a pair so the leaf is not fitted with a cylinder that the test never saw.
Access control sits on the staff doors rather than the public doors, so the consulting rooms and the back office open to a fob or a code while the entrance stays open to patients. The access control doors guide shows how a fob system is set so a lost fob can be cancelled without changing every lock in the building, and the door entry systems guide shows how the entrance calls the desk when the practice is locked between appointments.
Fire proof beside forced entry proof: one doorset, two tests
A consulting room leaf may need to hold fire as well as forced entry, and the two proofs are taken on the same doorset and sit in one report. EN 1634-1 proves the fire minutes and LPS 1175 Issue 8.2 of September 2024 proves the grade in B3, C5 and D10, so the order names both proofs beside the same leaf and the fitter checks both before the leaf is hung.
The fire and security doors dual certification guide shows how the pair is proved on one doorset, the LPS 1175 Issue 8 explained guide sets out what Issue 8.2 changed, and the SR2 vs SR3 vs SR4 guide sets the old names beside the new grades. What breaks a rating once a door is fitted is named in the keeping an LPS 1175 rating valid guide, and the gaps round the leaf are 4 mm once the leaf is hung.
Putting the whole practice on one schedule
One list carries the whole practice order, with a line for every opening that names the leaf, the grade, the lock and the closer beside it. A list that names one leaf for the whole practice leaves the fitter to guess which room takes which grade, and a leaf in the wrong room holds for the wrong number of minutes while the practice believes it is covered.
The record of each walk stays with the practice file, with the date, the leaves tried and the fault found beside each leaf, so a hinge that is wearing loose is seen on the walk before the leaf drops and the lock bolt misses its keep. The security door maintenance checklist names what the walk should cover, the fire door regulations offices guide takes the same care with the back office of a practice, and the emergency exit doors guide takes it with the way out at the back of the building.
An optician door holds only as long as the room behind it needs, so the grade, the lock and the closer must all sit on the same list beside the same leaf.
What grade should an optician entrance door carry?
B3 to LPS 1175 Issue 8.2, which holds for three minutes, because the entrance stands in view of the street and the waiting room all day.
What grade should an optician consulting room door carry?
C5 to LPS 1175 Issue 8.2, which holds for five minutes, because the room holds the patient, the records and the instruments behind a shut leaf.
Why does the frames store take D10?
The frames store holds the most valuable stock in the building, so D10 gives it ten minutes, the longest hold in the practice.
Can one leaf hold fire and forced entry?
Yes, where a single doorset passed the fire test and the forced entry test together, so both proofs sit in one report.
Who checks the optician doors?
The practice manager walks the building once a month with the door list, trying a few leaves on each walk.