Certified physical security

ArxBridge
Steel door sample in a security test frame with an assessor in a UK test laboratory

ArxBridge

Hotel Security Doors

Hotel security doors: rated doorsets for back of house, plant rooms and staff areas, with access control, fire proof and one schedule for the whole hotel.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed across the UK
Prefer to talk?+44 7352 267239

Get a free project quote

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

A hotel door works two jobs at once. It opens for guests all day, and it guards the rooms behind the guest floors where the hotel keeps its stores, its plant and its staff, and a door that fails on either side leaves the guest floors open to the wrong person, or shuts the staff out of the rooms they need.

The order starts with the hotel, not with the leaf. A plant room that feeds the whole building asks for a different door from a store that holds the linen, and a service entrance where deliveries arrive all day asks for a different lock from a staff corridor that guests never see.

One list should hold every security door in the hotel, with each one named plainly, so the right door lands on the right opening. The hotel fire doors guide covers the doors on the bedroom corridors and stair cores, and the plant room door requirements guide covers the doors on the rooms that feed the building.

  • LPS 1175 B3 / C5 / D10Forced entry ratings, three, five and ten minutes
  • FD30 / FD60Fire resistance periods tested to EN 1634-1
  • TS 007 3-starCylinder and handle sets
  • BS EN 1125Panic hardware for escape routes

Where a hotel puts its security doors: back of house, plant rooms and staff areas

Back of house is the part of the hotel guests never see, where staff move linen, food and luggage between the floors. The doors here must take constant use, trolleys and carts, and still shut on their own, because a door left open on a staff corridor is a gap in the line.

Plant rooms hold the boilers, the switchgear and the pumps that keep the hotel running, so the doors on them take a higher rating than the corridor doors, because the equipment behind them is worth more than the corridor, and the rating on the order should match what the room holds.

Staff areas hold the lockers, the offices and the rooms where the hotel keeps its keys, so the doors on them must open for the staff who belong there and stay shut for the rest. The commercial buildings fire door regulations guide sets out the periods for the shared parts of a building. Where the front of house needs windows beside the doors, the glass takes the same proof as the leaf, and the fire rated windows guide sets out the periods for the windows that share the wall.

The service entrance: deliveries, laundry and the door that never rests

The service entrance is the busiest door in the hotel, where deliveries arrive, laundry leaves and staff come and go through the day. Its leaf must take the knocks of the working day, so the hinge and the closer belong on the schedule beside the leaf.

A service door that stands open for a delivery is a door that lets anyone in, so it needs a closer that pulls the leaf shut every time and a latch that catches as the door closes. The loading bay doors guide covers the bays where deliveries arrive and leave.

Access at the service entrance should follow the shift, so a card that works for the morning team stops working when the shift ends. A pass that belongs to a member of staff who has left must be stopped on the system the same day, because a pass that still works is a door left open.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Staff access: cards, fobs and the door that must lock itself

A hotel turns staff over through the year, so keys walk out with people who no longer work there. A fob answers that problem, because it dies on the system the day the person leaves, while a key keeps working until the lock is changed, and the list of live fobs should be checked every month.

Keep the staff doors on the same access system as the rest of the hotel, so a single card opens the plant rooms, the stores and the back door, and a card that is stopped dies everywhere at once. Escape doors must still release on alarm, whatever the access system says, so no one is held inside when the alarm sounds.

A contractor who works in the hotel for a day takes a pass that ends when the day ends. The pass should die on its own, with no one having to remember to stop it, and the record should name the person, the door and the day.

Fire and security on one leaf: the back of house door that must do both

The doors behind the guest floors often need both proofs at once, fire and forced entry, and each proof needs its own test on the same doorset. Fire is proved to EN 1634-1 and forced entry to LPS 1175, and one test report cannot prove both, so the order should name both.

The kitchen is the hottest room in the hotel, so the doors around it carry FD60, while the stores and staff rooms carry FD30. Where a door guards a smoke path it takes FD30S, with the seal proved to BS EN 1634-3, to Sa for smoke at room temperature and S200 for smoke at 200 degrees Celsius.

The fire and security doors dual certification guide works through how the two proofs share one leaf. Closers on those doors need a power size of EN 3 or above to BS EN 1154, and the fire door closers guide covers the sizes and the fitting, while the fire door hardware guide covers the grades and the parts behind a working fire door.

Plant rooms and stores: the rooms behind the guest floors

A plant room door must hold fire back while the boilers and switchgear behind it keep running, so it takes FD60 where the fire load is heaviest, with a closer that pulls the leaf shut every time. The plant room door requirements guide covers the doors on the rooms that feed the building.

Stores hold the linen, the food and the goods the hotel sells, so the doors on them take a forced entry rating proved to LPS 1175, with B3 holding three minutes, C5 holding five minutes and D10 holding ten minutes, all under Issue 8.2, dated September 2024. The rating on the order should match the value of the goods behind the door.

Locks and hinges on the store door must match the leaf they carry. A TS 007 3-star set, made of a 1-star cylinder with a 2-star handle or escutcheon, keeps the lock proved. Hinges to BS EN 1935 carry the leaf through 200,000 cycles, with grade 13 rated for 120 kg and grade 14 for 160 kg, so the hinge should be chosen for the weight of the leaf it carries.

The front of house line: reception, bars and the doors guests see

The doors guests see must welcome them in and still hold when a person tries to force them, so the leaf, the lock and the closer must all be proved for the duty they carry. The opening force must stay below 30 N for the first 30 degrees of travel and below 22.5 N beyond, under BS 8300 and Approved Document M, so a guest of any strength can push the door open.

Glazed doors at reception let guests see the hotel while they keep the wrong hands out, so the glass must be proved for the job it does. The glass in them is proved to EN 356, with the top classes set by axe blows: 30 to 50 for P6B, 51 to 70 for P7B, and 70 or more for P8B. A reception door in steel takes the knocks of luggage and trolleys, while a timber door suits a hotel that wants a warmer look at the front, and the steel versus timber fire doors guide works through the choice.

Rooms that fill for the evening need panic hardware to BS EN 1125, a bar across at least 60 percent of the leaf width, because a crowd that cannot open the door in a fire is a crowd held inside. The smoke control doors guide covers the doors that must hold smoke back while people move past them.

Escape routes and the release: the door that must open for everyone

Escape in a hotel is slow in one way and fast in another, because guests do not know the building and staff must guide them, so the routes must stay clear and the doors on them must open with a light push. When the alarm sounds, every door on the escape route must open at once, and no key, no card and no code may stand between the guest and the street.

Doors that stand open through the day need a hold-open device to BS EN 1155, which lets the door shut the moment the alarm sounds. A wedge is not a hold-open device, and a door held open by one stays open when the alarm sounds, so the device belongs on the order with the door.

Every member of staff should know which doors to shut on the way out, because a fire door only works when it is shut. The evacuation plan names the doors on each route, and the drill tests whether they shut as they should, so the plan and the drill belong on the same record.

One schedule for the whole hotel: every door on one line

The enquiry works well as a single list, one line for every security door in the hotel, with the position, the fire period, the forced entry rating, the glazing and the hardware written on each line, so what arrives is what was proved.

Go through each quote line by line against the list before ordering. A part left off a quote still has to be bought, and fitting it round a door that is already in use costs more than ordering it with the door. The security door cost factors guide sets out what each step up the scale adds to the build, and the how to specify security doors guide sets out the columns the schedule needs.

Keep the test reports with the doors from the day they arrive, so the proof is never far from the leaf it belongs to. The fire door inspection checklist names what each round should look for, and the security door maintenance checklist covers the doors that must hold both fire and forced entry.

Position Door Rating What to check
Service entrance Solid security door LPS 1175 C5 Lock, hinges, closer
Plant room Fire door FD60 Seals, closer, latch
Store Solid security door LPS 1175 B3 Lock, hinges, reader
Kitchen Fire door FD60 Seals, closer, latch
Escape route Fire door FD30S Seals, closer, release

A hotel security door must guard the rooms guests never see, so the rating, the credential and the release must all sit on the same schedule.

What rating do hotel security doors need?

The room decides. A store that holds valuable goods takes a higher forced entry grade than a staff corridor, and a door on a compartment wall takes FD60 where the fire load is heaviest.

Do hotel security doors need a fire rating?

Only where the door guards an escape route or a compartment wall. There the proof is to EN 1634-1, and the period follows the fire load behind the door, FD30 for most rooms and FD60 where the load is heaviest.

Who opens the staff doors?

Each member of staff takes a fob for the rooms they use, and the list of live fobs is checked every month. When staff leave, the fob dies on the system the same day, while the escape doors still release on alarm.

Can a service door be held open during deliveries?

A service door may stand open only on a hold-open device to BS EN 1155, which shuts the door when the alarm sounds. A wedge under the leaf is not a hold-open device, and it leaves the door open in a fire.

Who checks hotel security doors?

The hotel manager, on the routine the fire risk assessment sets. The round covers the closers, the seals, the locks and the readers, and anything found wrong is written down the same day.

Pricing several openings at once? The security door enquiry checklist lists what to send for each one: location, size, rating and hardware.

Specifying security doors for a hotel?Send the door schedule and the hotel plan for a tested door quotation.
Get a free quote

Related

More in guides for specifiers

10 mistakes when specifying certified security doors 10 steps to specify an LPS 1175 door Acceptance and Snagging of a Security Door or Barrier Job Access Control Doors Acoustic Doors: Ratings and Specification After a Forced Entry Attempt: Checking a Security Door Airport Security Doors Anti-Ligature Doors for Mental Health Wards Anti-Ram Bollards Anti-ram gates and barriers: protecting vehicle entrances Arcade Security Doors Explained Automatic Doors Automatic Gates Cost Factors Automatic Vehicle Barriers Ballistic Panels Bank Security Doors Bingo Hall Security Doors Explained Blast doors: glazed vs solid and how they are rated Blast protection window film: what it does and what it cannot do Blast resistant windows: what drives the cost and how to specify them Bollard Cost Factors Explained Bollard regulations in the UK: spacing, height and depth Bookmaker Security Doors Explained Builders Merchant Security Doors Bullet Resistant Glass Cost Factors Bullet resistant glass ratings explained: BR1 to BR7 and SG classes Bullet resistant vs bulletproof glass: what the difference means Buying Security Doors and HVM Through Public Frameworks Car Park Security Doors Explained Car Showroom Security Doors Casino Security Doors Explained CDM 2015 Duties When Security Doors, Shutters or HVM Are Installed Cinema Security Doors Cleanroom Doors Cold Store Doors College Security Doors Commissioning, Handover and the O&M Manual for Security Doors and HVM Communal entrance doors for flats: Secured by Design and what to specify Community Centre Security Doors Control Room Doors Court Security Doors Crash Rated Fences and HVM Fencing Explained Data centre physical security: doors, glazing, HVM and shielding by zone Dental Practice Security Doors Depot Security Doors Explained Door Entry Systems Due Diligence When Selecting Vehicle Security Barriers Emergency Exit Doors EMP Shielding Cost Factors Explained Exhibition Centre Fire Door Rules Exhibition Centre Security Doors Factory Security Doors Faraday cage vs RF shielded room: what a business needs FB4 vs FB6 vs FB7: how to choose a ballistic rating Fire and security doors: how dual certification works Fire Compartmentation Fire Curtains Fire Door Certification Fire Door Closers Explained Fire Door Cost Factors Fire Door Duties of the Accountable Person Fire Door Gaps Fire Door Hardware Explained Fire door inspection checklist for steel and timber doors Fire Door Maintenance Fire Door Regulations Care Homes Fire Door Regulations for A and E Departments Fire Door Regulations for Airports Explained Fire Door Regulations for Bowls Clubs Fire door regulations for commercial buildings in the UK Fire Door Regulations for Dialysis Centres Fire Door Regulations for Hockey Clubs Fire Door Regulations for Hospitals Explained Fire Door Regulations for Offices Explained Fire Door Regulations for Operating Theatres Fire Door Regulations for Retail Explained Fire Door Regulations for Schools Explained Fire Door Regulations for Snooker Clubs Fire Door Regulations for Stadiums Fire Door Regulations for Student Accommodation Fire Door Regulations for Warehouses Fire Door Regulations Leisure Centres Fire Door Regulations Restaurants Fire Door Remediation Programme for Housing Providers Fire Door Rules for Badminton Clubs Fire Door Rules for Bingo Halls Fire Door Rules for Bookmakers Fire Door Rules for Bowling Alleys Fire Door Rules for Car Parks Fire Door Rules for Car Showrooms Fire Door Rules for Cinemas Fire Door Rules for Climbing Centres Fire Door Rules for Colleges Fire Door Rules for Community Centres Fire Door Rules for Cricket Clubs Fire Door Rules for Dental Practices Fire Door Rules for Depots Explained Fire Door Rules for Golf Clubs Fire Door Rules for GP Surgeries Fire Door Rules for Gyms Explained Fire Door Rules for Ice Rinks Fire Door Rules for Maternity Units Fire Door Rules for Mental Health Units Fire Door Rules for Museums Fire Door Rules for Oncology Units Fire Door Rules for Opticians Fire Door Rules for Pawnbrokers Fire Door Rules for Petrol Stations Fire Door Rules for Pharmacies Fire Door Rules for Ports Fire Door Rules for Post Offices Fire Door Rules for Prisons Fire Door Rules for Rehabilitation Centres Fire Door Rules for Self Storage Fire Door Rules for Shopping Centres Fire Door Rules for Squash Clubs Fire Door Rules for Supermarkets Fire Door Rules for Swimming Pools Fire Door Rules for Tennis Clubs Fire Door Rules for Theatres Fire Door Rules for UK Arcades Fire Door Rules for UK Casinos Fire Door Rules for UK Hospices Fire Door Rules for Walk-in Centres Fire Door Signage Fire Door Vision Panels Fire Doors and Gateway 2 in Higher-Risk Buildings Fire Rated Glass Cost Explained Fire Rated Sliding Doors Explained Fire Rated Windows Cost Factors Fire Rated Windows Explained Fire Safety Enforcement Notices and Fire Doors: What the Responsible Person Must Do Flat Entrance Doors: PAS 24 and Fire Rated Forced Entry vs Ballistic vs Blast: Which Rating a Site Needs Garage Security Doors Explained Gate Automation Explained Golden Thread Records for Fire Doors GP Surgery Security Doors Explained Gym Security Doors Explained High Speed Doors HMO Fire Doors Hospice Security Doors Explained Hospital Security Doors: Wards, A&E, Plant Hospital Security Gates Hotel Fire Doors How to choose HVM bollards: fixed, shallow mount, removable and automatic How to keep an LPS 1175 door rating valid after installation How to Specify Fire Doors in a Housing Tender How to specify security doors: a checklist for architects How to Verify a Secured by Design Listing How to Verify an LPS 1175 Certificate on Red Book Live How to Write an Operational Requirement for Physical Security HVM planters and street furniture: protection that blends in In-Service Care of Vehicle Security Barriers Installation Handover: LPS 1175 Doors and PAS 68 Barriers Intumescent Seals ISO 16933 explained: EXV and SB classes and hazard ratings ISO 22343 vehicle security barriers explained Keeping a Dual-Certified Fire and Security Door Valid in Service Laboratory Security Doors Layered Security for a Site: Deter, Detect, Delay, Mitigate, Respond Lead Times and Programme Risks for LPS 1175 Doors Leisure Centre Security Doors Library Security Doors Listed Building Fire Doors Loading Bay Doors Explained Lockdown and Access Control Hardware on an LPS 1175 Door LPS 1175 Gates and Grilles Explained LPS 1175 Issue 8 explained: from SR1 to SR8 to A1 to H20 LPS 1175 Roller Shutters LPS 1175 vs ASTM F2781 and Other US Ratings Explained LPS 1175 vs EN 1627: how UK and European burglar resistance ratings compare LPS 1175 vs PAS 24: which security standard does your door need? LPS 1175 Windows and Walling Explained Martyn’s Law and Places of Worship: What a Buyer Checks for Doors and Entry Control Martyn’s Law Enhanced Tier: Physical Measures and the Specifier Brief Martyn’s Law Standard Tier: Procedures, Doors and Shutters Martyn’s Law Timeline and the SIA Regulator Martyn’s Law: what premises must do and which physical measures to consider Master Key Systems MRI and RF shielded rooms: how they work and what to specify Museum Security Doors NPSA Catalogue of Security Equipment (CSE) Explained NPSA Forced Entry and Blast Guidance for Government Sites NPSA Guidance on Lockdown and Marauding Attack: What It Asks of Doors and Entrances Office Security Doors Optician Security Doors Explained Panic Hardware PAS 24 requirements for doors and windows explained PAS 68 Bollard Foundations Explained PAS 68 bollards: ratings, spacing and cost factors PAS 68 vs IWA 14 vs ISO 22343: hostile vehicle mitigation standards explained Pawnbroker Security Doors Explained Pedestrian Gates Petrol Station Security Doors Pharmacy Security Doors Planning Permission for Security Shutters, Gates and Bollards on Commercial Premises Plant room doors: fire, security and ventilation requirements Plant Room Fire Doors Port Security Doors Post Office Security Doors Explained Powder coating vs galvanising vs paint for steel Preliminary Market Engagement for Security Doors and HVM Prison Security Doors Programming a Security Door and Barrier Package on a Live Site Public-Sector Tender Response Checklist for Security Door and HVM Supply Reading a PAS 24 and SBD Door Test Report Regulation 38 Fire Safety Information at Handover for Fire-Rated Security Doorsets Replacing Security Doors in an Occupied Building Restaurant Security Doors Retail Security Doors Revolving Doors RF shielding standards and how shielded rooms are tested Rising Bollard Cost Factors Road Blocker Cost Factors Explained Road Blockers Explained Roller Shutter Cost Factors: What Drives the Price Roller shutter regulations in the UK: safety and maintenance Safe room and panic room doors: specification basics Safety Duties for Powered Doors, Gates and Barriers on Commercial Sites School Security Doors Sectional Doors Secured by Design explained: is it mandatory for doors? Secured by Design vs NPSA vs LPCB: Which One You Need Security Door Locks Security Door Maintenance Checklist Security Doors and Access for Everyone: What Approved Document M Asks Security Doors for A and E Departments Security Doors for Badminton Clubs Security Doors for Bowling Alleys Security Doors for Bowls Clubs Security Doors for Climbing Centres Security Doors for Cricket Clubs Security Doors for Dialysis Centres Security Doors for Golf Clubs Security Doors for Hockey Clubs Security Doors for Ice Rinks Security Doors for Maternity Units Security Doors for Mental Health Units Security Doors for Oncology Units Security Doors for Operating Theatres Security Doors for Rehabilitation Centres Security Doors for Snooker Clubs Security Doors for Squash Clubs Security Doors for Swimming Pools Security Doors for Tennis Clubs Security Doors for Walk-in Centres Security Doors West Midlands Explained Security Fencing Security Gates Cost Factors Explained Security shutters vs high performance roller doors Security shutters vs retractable grilles: which suits retail and commercial openings? Security Turnstiles Explained Security Window Film Security Windows for Schools Explained Self Storage Security Doors Server Room Doors Explained Shopping Centre Security Doors Smoke Control Doors Explained Smoke Curtains Specification Mistakes When Mixing LPS 1175, PAS 24 and SBD in One Tender SR2 vs SR3 vs SR4 security doors: choosing the right LPS 1175 level Stadium Security Doors Steel Door Frames Steel vs aluminium security doors: strength, ratings and looks Steel vs timber fire doors: which suits your building? Student Accommodation Security Doors Substation doors: security, ventilation and specification Supermarket Security Doors Telescopic Bollards Tender Evaluation Criteria and Scoring for Security Doors and HVM The Scope of a Maintenance Contract for Security Doors and Barriers Theatre Security Doors Thermal and Weather Performance of External Security Doorsets Thermally broken steel security doors: U-values and certification Traffic Calming as Hostile Vehicle Mitigation Transport hub security requirements Turnstile Cost Factors Explained Turnstile vs speed gate vs security portal: choosing entrance control Types of security doors for commercial buildings University Security Doors Explained Vehicle Dynamics Assessment: What It Tells the Buyer Before a Barrier Is Specified Warehouse Security Doors Explained Warehouse Security Gates Warranty, Defects Liability and Guarantees for Security Doors and Barriers What affects the cost of a bullet resistant door What affects the cost of a high-security door in the UK Window Security Bars View all →

Products

One supplier for the whole building envelope

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.