ArxBridge
Hotel Security Doors
Hotel security doors: rated doorsets for back of house, plant rooms and staff areas, with access control, fire proof and one schedule for the whole hotel.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A hotel door works two jobs at once. It opens for guests all day, and it guards the rooms behind the guest floors where the hotel keeps its stores, its plant and its staff, and a door that fails on either side leaves the guest floors open to the wrong person, or shuts the staff out of the rooms they need.
The order starts with the hotel, not with the leaf. A plant room that feeds the whole building asks for a different door from a store that holds the linen, and a service entrance where deliveries arrive all day asks for a different lock from a staff corridor that guests never see.
One list should hold every security door in the hotel, with each one named plainly, so the right door lands on the right opening. The hotel fire doors guide covers the doors on the bedroom corridors and stair cores, and the plant room door requirements guide covers the doors on the rooms that feed the building.
- LPS 1175 B3 / C5 / D10Forced entry ratings, three, five and ten minutes
- FD30 / FD60Fire resistance periods tested to EN 1634-1
- TS 007 3-starCylinder and handle sets
- BS EN 1125Panic hardware for escape routes
Where a hotel puts its security doors: back of house, plant rooms and staff areas
Back of house is the part of the hotel guests never see, where staff move linen, food and luggage between the floors. The doors here must take constant use, trolleys and carts, and still shut on their own, because a door left open on a staff corridor is a gap in the line.
Plant rooms hold the boilers, the switchgear and the pumps that keep the hotel running, so the doors on them take a higher rating than the corridor doors, because the equipment behind them is worth more than the corridor, and the rating on the order should match what the room holds.
Staff areas hold the lockers, the offices and the rooms where the hotel keeps its keys, so the doors on them must open for the staff who belong there and stay shut for the rest. The commercial buildings fire door regulations guide sets out the periods for the shared parts of a building. Where the front of house needs windows beside the doors, the glass takes the same proof as the leaf, and the fire rated windows guide sets out the periods for the windows that share the wall.
The service entrance: deliveries, laundry and the door that never rests
The service entrance is the busiest door in the hotel, where deliveries arrive, laundry leaves and staff come and go through the day. Its leaf must take the knocks of the working day, so the hinge and the closer belong on the schedule beside the leaf.
A service door that stands open for a delivery is a door that lets anyone in, so it needs a closer that pulls the leaf shut every time and a latch that catches as the door closes. The loading bay doors guide covers the bays where deliveries arrive and leave.
Access at the service entrance should follow the shift, so a card that works for the morning team stops working when the shift ends. A pass that belongs to a member of staff who has left must be stopped on the system the same day, because a pass that still works is a door left open.
Staff access: cards, fobs and the door that must lock itself
A hotel turns staff over through the year, so keys walk out with people who no longer work there. A fob answers that problem, because it dies on the system the day the person leaves, while a key keeps working until the lock is changed, and the list of live fobs should be checked every month.
Keep the staff doors on the same access system as the rest of the hotel, so a single card opens the plant rooms, the stores and the back door, and a card that is stopped dies everywhere at once. Escape doors must still release on alarm, whatever the access system says, so no one is held inside when the alarm sounds.
A contractor who works in the hotel for a day takes a pass that ends when the day ends. The pass should die on its own, with no one having to remember to stop it, and the record should name the person, the door and the day.
Fire and security on one leaf: the back of house door that must do both
The doors behind the guest floors often need both proofs at once, fire and forced entry, and each proof needs its own test on the same doorset. Fire is proved to EN 1634-1 and forced entry to LPS 1175, and one test report cannot prove both, so the order should name both.
The kitchen is the hottest room in the hotel, so the doors around it carry FD60, while the stores and staff rooms carry FD30. Where a door guards a smoke path it takes FD30S, with the seal proved to BS EN 1634-3, to Sa for smoke at room temperature and S200 for smoke at 200 degrees Celsius.
The fire and security doors dual certification guide works through how the two proofs share one leaf. Closers on those doors need a power size of EN 3 or above to BS EN 1154, and the fire door closers guide covers the sizes and the fitting, while the fire door hardware guide covers the grades and the parts behind a working fire door.
Plant rooms and stores: the rooms behind the guest floors
A plant room door must hold fire back while the boilers and switchgear behind it keep running, so it takes FD60 where the fire load is heaviest, with a closer that pulls the leaf shut every time. The plant room door requirements guide covers the doors on the rooms that feed the building.
Stores hold the linen, the food and the goods the hotel sells, so the doors on them take a forced entry rating proved to LPS 1175, with B3 holding three minutes, C5 holding five minutes and D10 holding ten minutes, all under Issue 8.2, dated September 2024. The rating on the order should match the value of the goods behind the door.
Locks and hinges on the store door must match the leaf they carry. A TS 007 3-star set, made of a 1-star cylinder with a 2-star handle or escutcheon, keeps the lock proved. Hinges to BS EN 1935 carry the leaf through 200,000 cycles, with grade 13 rated for 120 kg and grade 14 for 160 kg, so the hinge should be chosen for the weight of the leaf it carries.
The front of house line: reception, bars and the doors guests see
The doors guests see must welcome them in and still hold when a person tries to force them, so the leaf, the lock and the closer must all be proved for the duty they carry. The opening force must stay below 30 N for the first 30 degrees of travel and below 22.5 N beyond, under BS 8300 and Approved Document M, so a guest of any strength can push the door open.
Glazed doors at reception let guests see the hotel while they keep the wrong hands out, so the glass must be proved for the job it does. The glass in them is proved to EN 356, with the top classes set by axe blows: 30 to 50 for P6B, 51 to 70 for P7B, and 70 or more for P8B. A reception door in steel takes the knocks of luggage and trolleys, while a timber door suits a hotel that wants a warmer look at the front, and the steel versus timber fire doors guide works through the choice.
Rooms that fill for the evening need panic hardware to BS EN 1125, a bar across at least 60 percent of the leaf width, because a crowd that cannot open the door in a fire is a crowd held inside. The smoke control doors guide covers the doors that must hold smoke back while people move past them.
Escape routes and the release: the door that must open for everyone
Escape in a hotel is slow in one way and fast in another, because guests do not know the building and staff must guide them, so the routes must stay clear and the doors on them must open with a light push. When the alarm sounds, every door on the escape route must open at once, and no key, no card and no code may stand between the guest and the street.
Doors that stand open through the day need a hold-open device to BS EN 1155, which lets the door shut the moment the alarm sounds. A wedge is not a hold-open device, and a door held open by one stays open when the alarm sounds, so the device belongs on the order with the door.
Every member of staff should know which doors to shut on the way out, because a fire door only works when it is shut. The evacuation plan names the doors on each route, and the drill tests whether they shut as they should, so the plan and the drill belong on the same record.
One schedule for the whole hotel: every door on one line
The enquiry works well as a single list, one line for every security door in the hotel, with the position, the fire period, the forced entry rating, the glazing and the hardware written on each line, so what arrives is what was proved.
Go through each quote line by line against the list before ordering. A part left off a quote still has to be bought, and fitting it round a door that is already in use costs more than ordering it with the door. The security door cost factors guide sets out what each step up the scale adds to the build, and the how to specify security doors guide sets out the columns the schedule needs.
Keep the test reports with the doors from the day they arrive, so the proof is never far from the leaf it belongs to. The fire door inspection checklist names what each round should look for, and the security door maintenance checklist covers the doors that must hold both fire and forced entry.
| Position | Door | Rating | What to check |
|---|---|---|---|
| Service entrance | Solid security door | LPS 1175 C5 | Lock, hinges, closer |
| Plant room | Fire door | FD60 | Seals, closer, latch |
| Store | Solid security door | LPS 1175 B3 | Lock, hinges, reader |
| Kitchen | Fire door | FD60 | Seals, closer, latch |
| Escape route | Fire door | FD30S | Seals, closer, release |
A hotel security door must guard the rooms guests never see, so the rating, the credential and the release must all sit on the same schedule.
What rating do hotel security doors need?
The room decides. A store that holds valuable goods takes a higher forced entry grade than a staff corridor, and a door on a compartment wall takes FD60 where the fire load is heaviest.
Do hotel security doors need a fire rating?
Only where the door guards an escape route or a compartment wall. There the proof is to EN 1634-1, and the period follows the fire load behind the door, FD30 for most rooms and FD60 where the load is heaviest.
Who opens the staff doors?
Each member of staff takes a fob for the rooms they use, and the list of live fobs is checked every month. When staff leave, the fob dies on the system the same day, while the escape doors still release on alarm.
Can a service door be held open during deliveries?
A service door may stand open only on a hold-open device to BS EN 1155, which shuts the door when the alarm sounds. A wedge under the leaf is not a hold-open device, and it leaves the door open in a fire.
Who checks hotel security doors?
The hotel manager, on the routine the fire risk assessment sets. The round covers the closers, the seals, the locks and the readers, and anything found wrong is written down the same day.
Pricing several openings at once? The security door enquiry checklist lists what to send for each one: location, size, rating and hardware.
Get a free quote
Related
More in guides for specifiers
Products
One supplier for the whole building envelope
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.