In-Service Care of Vehicle Security Barriers

A barrier line keeps its rating only while someone looks after it. The checks, the record and the sign-off that hold a vehicle security line in service.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed across the UK
Prefer to talk?+44 7352 267239

Get a free project quote

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

A barrier line earns its rating in a test. It keeps it only while someone looks after it. This guide sets out the checks that hold a line in service.

  • Fixed lineUnits that never move
  • Operable gateUnits that open and shut
  • FoundationThe ground the rating stands on
  • RecordThe proof the checks happened

The line after handover

Once the handover is signed, the line passes from the installer to the people who run the site. From that day the rating rests on routine, not on the test report. The NPSA guidance on hostile vehicle mitigation puts it plainly: a scheme left alone will break down, and a breakdown can leave the site open or make a unit dangerous. Regular servicing picks up faults while they are still small.

Each part wears in its own way, and each one needs its own check. A fixed unit fails slowly, through rust or a shifted foundation; a gate fails fast, through a worn drive or a dead control.

Set the round before the first fault appears. Name the walker, the interval between walks, and the record each walk leaves. The vehicle barrier due diligence guide sets out the evidence questions to ask before a line is bought.

Walking the fixed units

Start at one end of the line and walk to the other, looking at every unit in turn. Check that each unit stands upright and true, its fixings tight, and its surface free of damage deeper than the finish. A leaning unit has moved in its foundation; a cracked base has lost its fixings.

Look at the spaces between the units as well as the units themselves. The line works as a whole, so a gap that has opened since the install is one a vehicle can use. Measure the gaps on the walk, and compare them with the spacing the test report and the installation drawings set out.

A new kerb, a resurfaced road or a trench beside a unit can all change what the foundation sits in. The bollard foundations guide covers the ground the rating stands on.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Gates, rising units and their controls

An operable unit works like a machine as well as a barrier, so its check covers the drive, the hinges or guides, the locks, and the controls that tell it to open. Run each unit through its full movement and watch it from both sides. It should travel smoothly, stop, and lock where it should. A juddering gate or a lock that no longer catches will fail when it is needed.

Test the controls the way the people on site use them. Try the normal control, the manual release, and the emergency route that lets a vehicle through when the power is out. The NPSA guidance names vehicle access control and emergency access as parts of the scheme, not extras.

Keep the moving parts clean. Leaves, grit and ice collect where a rising unit sits in its housing, and a unit that fails to rise fully fails at its job. The anti-ram gates guide covers the fixed and moving options at a vehicle entrance.

The ground the line stands on

The foundation decides whether the rating holds. The NPSA foundation guidance lists the types a site can use, and the rating was earned with one of them under the unit. Know which type sits under each unit, and check the ground around it. Note the foundation type on the record, so the next person knows what the rating rests on.

Check the ground after the first winter and after heavy rain. Look for cracking around a unit, for one that has sunk or tilted, and for water standing where it did not before. A moved foundation has changed the geometry the test assumed.

A rebuild must match the tested build or go further. Where the site forces a different foundation, an engineer should validate it before the line is relied on again. A repair that cuts the depth has no test behind it.

A repair usually means fresh concrete. Fresh concrete needs time to reach its strength, so do not load a fresh foundation before it is ready. The programme guide sets out the wait in full. The ISO 22343 guide shows what each field of a rating code means, and the HVM standards guide sets out how the ratings are written.

What the record should hold

Every walk should leave a record, and the record should live in one place. Note the date, the walker, each unit checked, each fault found, and what was done. A record that names the unit and the fault can be used by the next person; a record that says only “checked” cannot.

Keep the record with the evidence the line rests on: the installation drawings, the foundation design, the test report and the handover papers. The gov.uk golden thread guidance asks the same of fire door records. A barrier line deserves the same discipline.

Photograph each fault the day it is found, and file it with the record. A photograph of a cracked base shows the next person what the words describe, and dates the fault. The golden thread records guide covers the fire door records inside the thread, and the Operational Requirement guide sets out how the requirement for the line is written.

Part What to look for What a fail looks like
Fixed units Upright, tight fixings, sound surface Lean, crack, loose fixing
Gaps Spacing as drawn and tested One gap wider than the rest
Operable units Full travel, firm lock, working release Judder, short travel, dead control
Foundations Sound surface, no sink or tilt Crack, standing water, movement
Record Date, person, unit, fault, action A walk with nothing written down

When a repair changes the tested build

Not every repair touches the rating. A like-for-like part, fitted the way the test assumed, keeps the build the test saw. A different part, a different fixing, or a different foundation changes the build, and the rating no longer describes the line on site.

The test report is the only proof the rating has, so a change that the test never saw needs fresh evidence before the line is relied on again. That evidence can be a new test, a listing that covers the changed build, or an engineer who validates the change. What it cannot be is a brochure claim or a verbal assurance from the fitter.

Record the change the day it is made, with the old part named, the new part named, and the evidence covering it. If the evidence is not yet in hand, mark the unit as unproven. The rating maintenance guide sets out the same rule for security doors.

A barrier line is proved twice: once in the test, and again on every walk that finds it still as tested.

Who signs the line off

Sign-off sits with the person who owns the risk, not the person who fitted the part. That person should see the record and any change made, and sign only when the line matches the evidence. A signature given before the evidence arrives signs an unproven line.

Set the sign-off interval in advance, and tie it to the walks. A line walked every month but signed off once a year has eleven months with no owner behind it. The NPSA guidance asks for liaison with the authority’s security advisers and with engineers on the RSES register, before a change is made, not after it fails.

When a walk finds a fault the site cannot fix at once, say so in writing, name the risk it leaves open, and set the date the fix is due. A fault written down with a date is a job; one only spoken about is a surprise waiting for the next walk. The Vehicle Dynamics Assessment guide shows the threat the line was bought to stop, and the programme guide shows how the line was built.

How often should a barrier line be walked?

Set the interval before the first fault appears, and write it into the maintenance plan. Walk the operable units more often than the fixed ones: a gate wears with every movement, a fixed unit fails slowly.

A bollard has started to lean. What then?

Write it down with a photograph and a measurement, then treat the base as suspect until it is checked. The rating rests on the foundation as tested, and a unit that has shifted no longer matches it.

Does a like-for-like part need fresh evidence?

No, when the part matches the tested build and is fitted the way the test assumed. A different part, fixing or foundation is a change to the build, and it needs fresh evidence first.

Who can validate a changed foundation?

A suitably qualified and experienced engineer, such as a Principal engineer grade of the Register of Security Engineers and Specialists in hostile vehicle mitigation design. The NPSA foundation guidance names that route.

What should the record hold?

Date, walker, unit, fault, fix, and a photograph of each fault. Keep the file with the handover papers, the test report and the foundation design.

Keeping a barrier line in service?Send the line, the rating it holds, and the record that goes with it.
Contact us for a free quote

Related

More in guides for specifiers

10 mistakes when specifying certified security doors 10 steps to specify an LPS 1175 door Acceptance and Snagging of a Security Door or Barrier Job Access Control Doors Acoustic Doors: Ratings and Specification After a Forced Entry Attempt: Checking a Security Door Airport Security Doors Anti-Ligature Doors for Mental Health Wards Anti-Ram Bollards Anti-ram gates and barriers: protecting vehicle entrances Arcade Security Doors Explained Automatic Doors Automatic Gates Cost Factors Automatic Vehicle Barriers Ballistic Panels Bank Security Doors Bingo Hall Security Doors Explained Blast doors: glazed vs solid and how they are rated Blast protection window film: what it does and what it cannot do Blast resistant windows: what drives the cost and how to specify them Bollard Cost Factors Explained Bollard regulations in the UK: spacing, height and depth Bookmaker Security Doors Explained Builders Merchant Security Doors Bullet Resistant Glass Cost Factors Bullet resistant glass ratings explained: BR1 to BR7 and SG classes Bullet resistant vs bulletproof glass: what the difference means Buying Security Doors and HVM Through Public Frameworks Car Park Security Doors Explained Car Showroom Security Doors Casino Security Doors Explained CDM 2015 Duties When Security Doors, Shutters or HVM Are Installed Cinema Security Doors Cleanroom Doors Cold Store Doors College Security Doors Commissioning, Handover and the O&M Manual for Security Doors and HVM Communal entrance doors for flats: Secured by Design and what to specify Community Centre Security Doors Control Room Doors Court Security Doors Crash Rated Fences and HVM Fencing Explained Data centre physical security: doors, glazing, HVM and shielding by zone Dental Practice Security Doors Depot Security Doors Explained Door Entry Systems Due Diligence When Selecting Vehicle Security Barriers Emergency Exit Doors EMP Shielding Cost Factors Explained Exhibition Centre Fire Door Rules Exhibition Centre Security Doors Factory Security Doors Faraday cage vs RF shielded room: what a business needs FB4 vs FB6 vs FB7: how to choose a ballistic rating Fire and security doors: how dual certification works Fire Compartmentation Fire Curtains Fire Door Certification Fire Door Closers Explained Fire Door Cost Factors Fire Door Duties of the Accountable Person Fire Door Gaps Fire Door Hardware Explained Fire door inspection checklist for steel and timber doors Fire Door Maintenance Fire Door Regulations Care Homes Fire Door Regulations for A and E Departments Fire Door Regulations for Airports Explained Fire Door Regulations for Bowls Clubs Fire door regulations for commercial buildings in the UK Fire Door Regulations for Dialysis Centres Fire Door Regulations for Hockey Clubs Fire Door Regulations for Hospitals Explained Fire Door Regulations for Offices Explained Fire Door Regulations for Operating Theatres Fire Door Regulations for Retail Explained Fire Door Regulations for Schools Explained Fire Door Regulations for Snooker Clubs Fire Door Regulations for Stadiums Fire Door Regulations for Student Accommodation Fire Door Regulations for Warehouses Fire Door Regulations Leisure Centres Fire Door Regulations Restaurants Fire Door Remediation Programme for Housing Providers Fire Door Rules for Badminton Clubs Fire Door Rules for Bingo Halls Fire Door Rules for Bookmakers Fire Door Rules for Bowling Alleys Fire Door Rules for Car Parks Fire Door Rules for Car Showrooms Fire Door Rules for Cinemas Fire Door Rules for Climbing Centres Fire Door Rules for Colleges Fire Door Rules for Community Centres Fire Door Rules for Cricket Clubs Fire Door Rules for Dental Practices Fire Door Rules for Depots Explained Fire Door Rules for Golf Clubs Fire Door Rules for GP Surgeries Fire Door Rules for Gyms Explained Fire Door Rules for Ice Rinks Fire Door Rules for Maternity Units Fire Door Rules for Mental Health Units Fire Door Rules for Museums Fire Door Rules for Oncology Units Fire Door Rules for Opticians Fire Door Rules for Pawnbrokers Fire Door Rules for Petrol Stations Fire Door Rules for Pharmacies Fire Door Rules for Ports Fire Door Rules for Post Offices Fire Door Rules for Prisons Fire Door Rules for Rehabilitation Centres Fire Door Rules for Self Storage Fire Door Rules for Shopping Centres Fire Door Rules for Squash Clubs Fire Door Rules for Supermarkets Fire Door Rules for Swimming Pools Fire Door Rules for Tennis Clubs Fire Door Rules for Theatres Fire Door Rules for UK Arcades Fire Door Rules for UK Casinos Fire Door Rules for UK Hospices Fire Door Rules for Walk-in Centres Fire Door Signage Fire Door Vision Panels Fire Doors and Gateway 2 in Higher-Risk Buildings Fire Rated Glass Cost Explained Fire Rated Sliding Doors Explained Fire Rated Windows Cost Factors Fire Rated Windows Explained Fire Safety Enforcement Notices and Fire Doors: What the Responsible Person Must Do Flat Entrance Doors: PAS 24 and Fire Rated Forced Entry vs Ballistic vs Blast: Which Rating a Site Needs Garage Security Doors Explained Gate Automation Explained Golden Thread Records for Fire Doors GP Surgery Security Doors Explained Gym Security Doors Explained High Speed Doors HMO Fire Doors Hospice Security Doors Explained Hospital Security Doors: Wards, A&E, Plant Hospital Security Gates Hotel Fire Doors Hotel Security Doors How to choose HVM bollards: fixed, shallow mount, removable and automatic How to keep an LPS 1175 door rating valid after installation How to Specify Fire Doors in a Housing Tender How to specify security doors: a checklist for architects How to Verify a Secured by Design Listing How to Verify an LPS 1175 Certificate on Red Book Live How to Write an Operational Requirement for Physical Security HVM planters and street furniture: protection that blends in Installation Handover: LPS 1175 Doors and PAS 68 Barriers Intumescent Seals ISO 16933 explained: EXV and SB classes and hazard ratings ISO 22343 vehicle security barriers explained Keeping a Dual-Certified Fire and Security Door Valid in Service Laboratory Security Doors Layered Security for a Site: Deter, Detect, Delay, Mitigate, Respond Lead Times and Programme Risks for LPS 1175 Doors Leisure Centre Security Doors Library Security Doors Listed Building Fire Doors Loading Bay Doors Explained Lockdown and Access Control Hardware on an LPS 1175 Door LPS 1175 Gates and Grilles Explained LPS 1175 Issue 8 explained: from SR1 to SR8 to A1 to H20 LPS 1175 Roller Shutters LPS 1175 vs ASTM F2781 and Other US Ratings Explained LPS 1175 vs EN 1627: how UK and European burglar resistance ratings compare LPS 1175 vs PAS 24: which security standard does your door need? LPS 1175 Windows and Walling Explained Martyn’s Law and Places of Worship: What a Buyer Checks for Doors and Entry Control Martyn’s Law Enhanced Tier: Physical Measures and the Specifier Brief Martyn’s Law Standard Tier: Procedures, Doors and Shutters Martyn’s Law Timeline and the SIA Regulator Martyn’s Law: what premises must do and which physical measures to consider Master Key Systems MRI and RF shielded rooms: how they work and what to specify Museum Security Doors NPSA Catalogue of Security Equipment (CSE) Explained NPSA Forced Entry and Blast Guidance for Government Sites NPSA Guidance on Lockdown and Marauding Attack: What It Asks of Doors and Entrances Office Security Doors Optician Security Doors Explained Panic Hardware PAS 24 requirements for doors and windows explained PAS 68 Bollard Foundations Explained PAS 68 bollards: ratings, spacing and cost factors PAS 68 vs IWA 14 vs ISO 22343: hostile vehicle mitigation standards explained Pawnbroker Security Doors Explained Pedestrian Gates Petrol Station Security Doors Pharmacy Security Doors Planning Permission for Security Shutters, Gates and Bollards on Commercial Premises Plant room doors: fire, security and ventilation requirements Plant Room Fire Doors Port Security Doors Post Office Security Doors Explained Powder coating vs galvanising vs paint for steel Preliminary Market Engagement for Security Doors and HVM Prison Security Doors Programming a Security Door and Barrier Package on a Live Site Public-Sector Tender Response Checklist for Security Door and HVM Supply Reading a PAS 24 and SBD Door Test Report Regulation 38 Fire Safety Information at Handover for Fire-Rated Security Doorsets Replacing Security Doors in an Occupied Building Restaurant Security Doors Retail Security Doors Revolving Doors RF shielding standards and how shielded rooms are tested Rising Bollard Cost Factors Road Blocker Cost Factors Explained Road Blockers Explained Roller Shutter Cost Factors: What Drives the Price Roller shutter regulations in the UK: safety and maintenance Safe room and panic room doors: specification basics Safety Duties for Powered Doors, Gates and Barriers on Commercial Sites School Security Doors Sectional Doors Secured by Design explained: is it mandatory for doors? Secured by Design vs NPSA vs LPCB: Which One You Need Security Door Locks Security Door Maintenance Checklist Security Doors and Access for Everyone: What Approved Document M Asks Security Doors for A and E Departments Security Doors for Badminton Clubs Security Doors for Bowling Alleys Security Doors for Bowls Clubs Security Doors for Climbing Centres Security Doors for Cricket Clubs Security Doors for Dialysis Centres Security Doors for Golf Clubs Security Doors for Hockey Clubs Security Doors for Ice Rinks Security Doors for Maternity Units Security Doors for Mental Health Units Security Doors for Oncology Units Security Doors for Operating Theatres Security Doors for Rehabilitation Centres Security Doors for Snooker Clubs Security Doors for Squash Clubs Security Doors for Swimming Pools Security Doors for Tennis Clubs Security Doors for Walk-in Centres Security Doors West Midlands Explained Security Fencing Security Gates Cost Factors Explained Security shutters vs high performance roller doors Security shutters vs retractable grilles: which suits retail and commercial openings? Security Turnstiles Explained Security Window Film Security Windows for Schools Explained Self Storage Security Doors Server Room Doors Explained Shopping Centre Security Doors Smoke Control Doors Explained Smoke Curtains Specification Mistakes When Mixing LPS 1175, PAS 24 and SBD in One Tender SR2 vs SR3 vs SR4 security doors: choosing the right LPS 1175 level Stadium Security Doors Steel Door Frames Steel vs aluminium security doors: strength, ratings and looks Steel vs timber fire doors: which suits your building? Student Accommodation Security Doors Substation doors: security, ventilation and specification Supermarket Security Doors Telescopic Bollards Tender Evaluation Criteria and Scoring for Security Doors and HVM The Scope of a Maintenance Contract for Security Doors and Barriers Theatre Security Doors Thermal and Weather Performance of External Security Doorsets Thermally broken steel security doors: U-values and certification Traffic Calming as Hostile Vehicle Mitigation Transport hub security requirements Turnstile Cost Factors Explained Turnstile vs speed gate vs security portal: choosing entrance control Types of security doors for commercial buildings University Security Doors Explained Vehicle Dynamics Assessment: What It Tells the Buyer Before a Barrier Is Specified Warehouse Security Doors Explained Warehouse Security Gates Warranty, Defects Liability and Guarantees for Security Doors and Barriers What affects the cost of a bullet resistant door What affects the cost of a high-security door in the UK Window Security Bars View all →

Products

One supplier for the whole building envelope

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.