One enquiry for eight openings: station, theatre, tower, market, dock, plant room, substation and school, with the rating, size and hardware doors must hold.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A quote for security doors across eight openings needs one enquiry naming each opening, the rating it must hold, its size and the hardware beside it, for a station, a theatre, a tower, a market hall, a dock, a plant room, a substation and a school in the UK.
- Eight openingsStation, theatre, tower, market, dock, plant, substation, school
- B3 to D10Three, five and ten minutes, LPS 1175 Issue 8
- LPS 2081SRA one minute, SRB three minutes, where stealth entry applies
- EN 1634-1Fire class and minutes where the compartment needs it
Each opening below takes the same shape of enquiry: rating first, size beside it, then the fire rating and the hardware where each one is needed.
| Opening | Usual rating | What the enquiry names |
|---|---|---|
| Station concourse | B3, C5 where out of sight | Size, rating, fire class, access control, traffic count |
| Theatre stage door | B3 | Size, rating, lock, key levels, power failure behaviour |
| Tower lobby | B3 or C5 | Size, rating, access control, closer, fire class |
| Market hall service door | C5 | Size, rating, fire class, lock, delivery pattern |
| Dock personnel door | C5 | Size, rating, fire class, closer, key levels |
| Plant room | LPS 2081 SRB | Size, rating, lock, ventilation, access list |
| Substation | LPS 2081 SRB | Size, rating, lock, key holders, access list |
| School entrance | B3 | Size, rating, closer, panic hardware, access control |
The concourse door takes the crowd, and the back door takes the rating
A station concourse door works in full view of the public all day, so an attack on it is quick and public, while a door at the back of the station, in a service corridor or a plant passage, sits out of sight and needs more time on its rating. The two openings take different ratings on most orders: B3 where the public can see the door, C5 where it sits out of sight, each on its own line.
The concourse door also carries the crowd. It must open for the people who use it every day and shut behind them, and the force to open it stays below 30 N through the first 30 degrees and below 22.5 N past that point, to BS 8300 with Approved Document M. Where the concourse holds 800 or more people, the enhanced tier of Martyn’s Law applies, with the Security Industry Authority as regulator and a go-live in spring 2027 expected, so the enquiry should name the capacity beside the door. The transport hub security requirements guide covers the doors round the same concourse, and the LPS 1175 standard page sets out the ratings.
For a station the enquiry names the concourse size, the rating on each door, the fire class to EN 1634-1 where the compartment needs it, the access control and the traffic count through the busiest hour.
A small opening with a long working day asks more of its rating than the front doors do
A theatre stage door sits at the back of the building, away from the front of house, where cast, crew and deliveries pass through from morning until late at night. It is a small opening with a long working day, and it is out of sight of the street, so the rating on it does more work than the rating on the front doors. B3 fits many stage doors, holding three minutes against the tool set for its category to LPS 1175 Issue 8.2, September 2024.
The lock carries the rating as much as the leaf does. The lock must hold the leaf shut against the attack the rating names and still open for the person who holds the key, and a 1 star cylinder with a 2 star handle makes a 3 star set under TS 007. Order the closer with the lock: closers to BS EN 1154 run from EN 1, the smallest size, and a fire door takes EN 3 as the smallest. For a theatre the enquiry names the size, the rating, the lock type, the key levels and the power failure behaviour, and the master key guide shows how the keys sit on one suite.
Card, fob or intercom: the lobby door opens for the people on the list
A tower lobby door is the first door every visitor meets, and it must open for the people who belong in the building and stay shut for the rest. A card or a fob opens the door for the staff who use the lobby every day, and a fob can be stopped when staff leave, because a fob costs nothing to stop and a key costs a new one. Visitors take the intercom, and the lane should hold the visitor while the check runs.
The lobby door takes B3 on most orders, and C5 where the lobby sits out of sight of the street or the building holds high value stock behind it. Where the lobby door also guards a fire compartment, it takes a second proof: fire is proved to EN 1634-1, with E, EW or EI and the minutes beside the class, and the two proofs sit on separate lines because each is proved on its own test. The fire ratings page sets out the E, EW and EI classes, and the fire door closers guide covers the sizes and the fitting of the closer.
For a tower the enquiry names the lobby size, the rating, the access control, the closer and the fire class where the compartment needs it.
Deliveries come through the back, so the back door carries the higher rating
A market hall service door sits at the back of the hall, away from the stalls and the public, where deliveries arrive through the day and the door stays shut overnight. It sits out of sight of the road, where an attacker can work unseen, and a C5 door there gives the alarm time to work, holding five minutes against the tool set for its category to LPS 1175 Issue 8.
The service door also meets trolleys and cages every day, so the leaf, the frame and the hardware must take the knocks of the working day as well as the attack the rating names. A door that must also hold fire takes a second proof to EN 1634-1, and the fire class and the minutes sit beside the LPS 1175 rating on the same line, with both sets of minutes on the same evidence. The warehouses and logistics sector page covers the doors round the same yards, and the how to specify security doors guide sets out the columns the schedule needs.
For a market hall the enquiry names the service door size, the rating, the fire class, the lock and the delivery pattern through the day.
Beside the freight, the personnel door holds the same line as the fence
A dock personnel door stands beside the freight, where lorries and containers move through the day and the people who work the dock pass in and out on foot. It is the way in for the people who belong on the dock, and it must hold the same line as the gates and the fence beside it, because an attack moves to the weakest part of the boundary.
The dock door takes C5 on most orders, holding five minutes where the door sits out of sight of the road, and the closer pulls the leaf shut after each person, because a door that needs a hand to close it will be left open. Where the door sits on a fire compartment wall it takes a fire class to EN 1634-1 as well, with the class and the minutes on the same line as the LPS 1175 rating. The keeping an LPS 1175 rating valid guide sets out what breaks a rating, and the warehouse security doors guide covers the doors on the stores behind the docks.
For a dock the enquiry names the personnel door size, the rating, the fire class, the closer and the key levels.
The quiet attack decides the rating in a plant room
A plant room holds the equipment that keeps the building running, and the door on it is the opening the tools reach first. The attack on a plant room is quiet rather than loud: an intruder who wants the equipment works without drawing attention, so the rating that fits is the one proved against stealth entry, not against a noisy attack in public view.
LPS 2081 proves doors against stealth entry, with SRA holding one minute and SRB holding three minutes, and SRB fits most plant rooms. The lock on a plant room door must hold the leaf shut and still open for the people on the access list, and the list belongs on the order beside the lock, naming who may open the door and who may not. Ventilation belongs on the enquiry too, because a plant room door that shuts tight must still let the room breathe, and a vent cut into a rated leaf after fitting breaks the tested set. The ten steps to specify an LPS 1175 door guide runs through the same discipline for the forced entry side.
For a plant room the enquiry names the size, the LPS 2081 rating, the lock, the ventilation and the access list.
A substation door guards live equipment, not stock
A substation holds live equipment behind a locked door, and the risk inside is not only theft. An intruder who reaches the equipment can be hurt by it, so the door must keep people out as surely as it keeps the equipment in, and the rating that fits is again the one proved against stealth entry.
LPS 2081 SRB fits most substations, holding three minutes against a quiet attack, and the key holders belong on the order beside the lock, naming who holds the key that opens the door and which keys open one. The door must open from the inside without a key, because a person inside the room must be able to leave when the danger passes, and the release belongs on the order beside the lock. A substation door that also guards a fire compartment takes a fire class to EN 1634-1 as well, with both proofs on the same evidence. For a substation the enquiry names the size, the LPS 2081 rating, the lock, the key holders and the access list.
One enquiry can cover all eight openings when each door sits on its own line with opening, rating, size and hardware, and each line is read back before it is sent. An order that names size alone comes back as a standard door.
One entrance door carries the whole school day, from the first bell to the last
A school entrance door is the door the day runs through, opening for pupils, staff and visitors from the first bell to the last, and it must open for the people who belong in the school and stay shut for the rest. A card or a fob opens the door for the staff who use it every day, and visitors take the intercom at the gate, so the door opens for that visit alone.
The school entrance takes B3 on most orders, holding three minutes to LPS 1175 Issue 8, and the closer pulls the leaf shut after each person, with the power size chosen for the leaf. Where over 60 people use the door, a panic bar to BS EN 1125 throws the latch when pushed, and the bar must cover at least 60 per cent of the leaf width. The push to open it stays below 30 N through the first 30 degrees and below 22.5 N past that point, to BS 8300 with Approved Document M. The school security doors guide covers the doors on a site where keys change hands often, and the security turnstiles guide covers the lobby line beside the doors.
For a school the enquiry names the entrance size, the rating, the closer, the panic hardware and the access control.
Fire door evidence by building type. walk in centres, rehabilitation centres, self storage, petrol stations. Read the one that matches your site before you fill in the checklist.
What to send us: the opening list, the sizes and the photos
One enquiry covers all eight openings when each door sits on its own line with opening, rating, size, lock and operation, and each line is read back before it is sent. A door order needs the rating, size and fire or second rating on the same line, because an order that names size alone comes back as a standard door.
If the opening already has a door in service, the product guides explain what wears and what we check on a visit: ballistic panels, high-speed doors, sectional doors, automatic doors, revolving doors, cold-store doors, cleanroom doors and steel door frames. Reading the one for your opening first helps you take photos of the parts we will ask about.
For fire doors and special buildings, the same applies: fire door certification, intumescent seals, fire compartmentation, listed-building fire doors, museum security doors, airport security doors, court security doors. If the budget is the first question, the guides on fire door cost factors and EMP shielding cost factors list what moves the price before you send the list.
For doors already in daily use, these guides also cover how they wear and what a regular check looks for: access control doors, fire door maintenance, fire door vision panels, HMO fire doors and window security bars. For healthcare and retail buildings, the fire door guides for A and E departments, dialysis centres, mental health units, oncology units, operating theatres and pawnbrokers describe the wear each room puts on its doors. Reading the one for your building helps you note which doors see the most use before you send photos.
For a site in one of these cities, the city page sets out what a local enquiry usually involves: Birmingham (busy commercial entrances and fire separation on commercial and industrial sites), Leicester (loading bays and yards), Oxford (listed building consent before any door is made) and Cambridge (rated vents and openings in laboratory fire lines).
- Opening list, with the use and the traffic through each opening.
- Opening sizes, with the width and height of each.
- Photos of each opening, the frame and the wall beside it.
- Existing ratings on the doors already fitted, where the new door must match them.
- Survey access, naming the day and the hours the site can be walked.
- Evidence to send: the test report for each door showing rating and size on the same product.
Send the list to [email protected], or call or WhatsApp us, and we reply within one working day. The fire door inspection checklist names what each round should look for once the doors are fitted.
Can one enquiry cover all eight openings?
Yes, one enquiry can name the openings for a station, a theatre, a tower, a market hall, a dock, a plant room, a substation and a school together, with a line per door naming opening, rating, size and hardware.
What rating fits a theatre stage door?
B3 fits many stage doors, holding three minutes against the tool set for its category to LPS 1175 Issue 8. A stage door out of sight of the street, or one holding high value stock, may need C5.
Why does a plant room take LPS 2081 and not LPS 1175?
Because the attack on a plant room is quiet. LPS 2081 proves doors against stealth entry, with SRA holding one minute and SRB holding three minutes, while LPS 1175 proves doors against a forced entry attack with hand tools.
Does an LPS 1175 rating prove fire resistance?
No. A door that claims both must show test evidence for each rating on the same product, with the fire class and minutes to EN 1634-1 beside the LPS 1175 rating.
Why must the size sit beside the rating?
Because the rating was proved at one size, and a wider leaf flexes more and loads the frame harder, so the test evidence must name the size on the order.
What belongs in a security door enquiry for a mixed site?
List every opening on its own line, naming the building, the room, the leaf size, the swing, the lock and the closer. Add the LPS 1175 Issue 8.2 grade for each door, and the fire period to EN 1634-1 for each opening that needs one. A clear line per door stops a station leaf being quoted against a school opening.
Which drawings should go with a security door enquiry?
Send a floor plan for each building, marking every opening with its leaf size and swing. Add a wall section at each opening, naming the wall build and the way the frame is fixed. For a dock or a substation, mark the clear width and the head height, so the leaf on the order matches the opening it must fill.
How is a rating written on a security door order?
Put the rating on the same line as the door it belongs to, beside the size and the hardware. State the LPS 1175 Issue 8.2 grade first, such as B3 or C5, then add the fire class and its minutes to EN 1634-1 where the door claims both. A rating written apart from its door leaves the buyer unable to check the proof.
What decides how long a security door order takes?
The order moves in stages. First the drawings are agreed, so the leaf size and the hardware suit the plan and the frame fixing. Next the rating proof is checked, since a door with two ratings needs test proof for each one. Then making time turns on the grade, the fire period and how many doors the order holds, with fitting sequenced once each opening is ready.
What proof arrives with a security door?
Each door should come with the test report that proves its ratings. The report gives the LPS 1175 Issue 8.2 grade, and the EN 1634-1 fire class with its minutes where the door also claims fire resistance. Check the report against the order, matching the leaf size and the hardware, and keep it with the order so the rating on the door traces back to its test.