Certified physical security

ArxBridge
Solid and glazed navy blast doors side by side in a test bay

ArxBridge

Blast doors: glazed vs solid and how they are rated

Blast door requirements for UK sites: how solid and glazed blast doors are rated to EN 13123 and EN 13124, and what to check in the frame, wall and glazing.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed across the UK
Prefer to talk?+44 7352 267239

Get a free project quote

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

A blast door is only as good as its tested class, its frame and the wall it sits in. Solid doors reach the highest blast classes because there is no glazing to fail. Glazed doors trade some performance for visibility and light, with the glass carrying its own tested class. Choose from the threat assessment, not from a catalogue.

  • EXR1 to EXR5Blast classes for doors, arena tested
  • EPR1 to EPR4Blast classes for doors, shock tube tested
  • EXV10 to EXV45ISO 16933 classes for blast glazing
  • A to FGlass hazard rating, no break to high hazard

How a blast door works

A blast door does one thing: it takes the pressure wave from an explosion and passes it safely into the building structure. The leaf is built stiff enough to catch the load without tearing. The frame is built strong enough to hold the leaf seated when the wave hits. The fixings carry the whole load from the frame into the wall. If any one of those links fails, the rating on the certificate means nothing.

That is why a blast door looks different from an ordinary steel door. Leaves are thicker and heavier, hinges are oversized, and locking is usually multipoint, with bolts engaging the frame at several points so the leaf cannot be blown out of its seat. The door only performs if it is closed and latched when the event happens, so closers and locking hardware are part of the safety case.

Weight has a daily cost. A solid high class leaf can weigh several times what a normal fire door weighs. Opening effort, closer power, hinge wear and the strength of the floor and wall around the frame all have to be designed for the real weight, not the weight of the door you are replacing. Our blast resistant doors are supplied as a complete tested system, not just a leaf.

The European blast classes: EPR, EXR and what they mean

In the UK and Europe, blast doors, windows and shutters are rated under EN 13123 and EN 13124. The classes run in two families. EPR1 to EPR4 come from the shock tube route, where a controlled pressure wave is fired at the test specimen. EXR1 to EXR5 come from the arena route, where real explosives are detonated at a set distance from the specimen. Both routes test the complete assembly, leaf, frame, glazing and fixings together.

The class numbers rise with severity. An EXR5 door has survived a far more severe event than an EXR1 door. The arena route is the closer match to a real explosion, which is why counter terrorism specifications in the UK usually name EXR classes. Industrial and petrochemical sites, where the threat is a vapour cloud or process explosion, more often name EPR classes. The blast ratings standards page sets out the classes side by side.

State the class, the route and the standard in every specification. “Blast resistant” on its own is not a specification. Ask for the test evidence against the exact construction you are buying, including the frame, the fixings and any glazing, and keep the evidence with the project records.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

ISO 16933 and the glazing inside a blast door

When a blast door has glass in it, the glass is tested under ISO 16933. This is the arena test for blast glazing. The EXV classes use 100 kg of TNT equivalent at a stand off distance, and the number in the class is that distance in metres: EXV45, EXV33, EXV25, EXV19, EXV15, EXV12 and EXV10. EXV10 is the most severe, because the charge is only 10 metres from the glass. The SB classes cover a different threat, the hand carried satchel charge placed close to the glass.

Every ISO 16933 result also carries a hazard rating from A to F. Hazard rating A means no break, the glass stays intact. The ratings run down to F, which is high hazard, where fragments enter the protected space. The hazard rating is what tells you whether people behind the door stay safe, so read it alongside the EXV or SB class, never on its own. Our guide to EXV vs SB classes explains the difference.

The glazing class is not the door class. A door with EXV25 glass is not automatically an EXR rated door. The glazed door as a whole, frame, fixings and glass together, must carry its own EN 13123 or EN 13124 classification. Our blast resistant glass page covers the glazing side, and blast resistant windows face the same assembly rule.

Glazed versus solid: the honest comparison

A solid blast door has no glass, so there is no glazing failure mode. That is why the highest classes are usually solid only. The leaf takes the wave as one piece, the hazard inside stays low, and there is nothing for an attacker to see through. The trade off is no visibility. Plant rooms, risers, stores and back of house openings rarely need it, so solid is the natural choice there.

A glazed blast door exists for openings where people must see who is on the other side or where daylight matters: receptions, control rooms, security screening points, lobbies in protected buildings. The glass lets the job be done, but it is always the weak point. The tested glazed area is limited, the hazard rating of the glass decides the safety of the room, and the glazing units are heavy, which adds to the leaf weight the hinges and closer must handle.

The table below lays the comparison out.

Factor Solid blast door Glazed blast door What to check
Highest classes Full range, EXR1 to EXR5 available Glazed area caps the class on most designs The class on the assembly certificate
Visibility None Staff can see visitors and threats Whether the role actually needs it
Glass hazard No glass, no hazard rating needed Hazard rating A to F, from the ISO 16933 test Rating letter against the room use
Weight and daily use Heavy leaf, simple hardware Heavy leaf plus glazing units Closer, hinges and opening effort
Privacy Full None, unless blinds or film are added Whether the opening faces the public
Typical fit Plant rooms, risers, stores, service entries Receptions, control rooms, screening points The threat assessment for that opening

The assembly rule. The rating belongs to the tested doorset, frame, fixings and glazing together. A rated leaf in an untested frame, or rated glass in an untested door, is not a rated blast door.

When the rating has to share the door

Many openings need more than blast resistance. A door on a protected building may also need forced entry resistance to LPS 1175, with B3 at 3 minutes against hand tools, C5 at 5 minutes against crowbars and drills, or D10 at 10 minutes against sledgehammers and disc cutters. An SR2 security door construction shows how the forced entry side is built. Each rating needs its own test evidence on the same construction. A blast class says nothing about forced entry, and a forced entry rating says nothing about blast.

Ballistic combinations follow the same rule. A door can carry an EN 1522 ballistic class such as FB4 or FB6 and a blast class at the same time, but only if both tests were run against the same doorset design. Our bullet resistant doors and the choosing a ballistic rating guide cover that side. Never assume a thick ballistic leaf will pass a blast test. The two tests load the door in completely different ways.

Fire is the third common combination. A blast door is only a fire door if it was also tested to EN 1634-1 and classified E, EW or EI with minutes. The fire rated steel doors page covers that side. If your opening needs all three, say so at the start of the enquiry, because combined evidence is designed in, not added afterwards.

The frame and the wall are part of the rating

The frame carries the blast load from the leaf into the wall. That makes the frame a structural component, not trim. The tested fixings, their spacing, their depth and the substrate they were tested in are all named in the evidence. Changing the fixing type on site, or fitting the frame into a weaker wall than the tested one, takes the installation outside the certificate.

The wall itself has to survive. A rated door in an ordinary partition wall is a strong door in a weak opening. The wall around a blast door must take the load the frame passes into it, which usually means a structural engineer checks the wall build up and confirms it is adequate. Retrofits are where this bites hardest: an existing wall that suits a fire door will often not suit a blast door without strengthening.

Plan the wall, the frame and the fixings as one package. Installers should work from the tested fixing detail, as the installation page outlines, and the specifying security doors guide shows how to write fixings into an enquiry.

Survey, engineer input and what to put in the specification

Start with the threat, not the product. The threat assessment sets the stand off distance and the charge size, and those two numbers point at the class: EXV and SB for the glazing, EPR or EXR for the door assembly. A security consultant or the project engineer should confirm the class before any supplier is approached. Guessing a class wastes the budget on the wrong door and its replacement.

Bring the structural engineer in early. The engineer confirms the wall can take the transferred load, the fixings suit the substrate, and the surrounding structure will not fail before the door does. Our government and defence sector page covers the wider protective security context, and design support can shape the door around the engineer’s requirements.

Write the specification as one line that names everything: the standard, the class and the route, solid or glazed, the glazing class and hazard rating if glazed, the hardware schedule, and the requirement that labels and test evidence match the supplied doorset. The blast windows cost and specification guide applies the same discipline to windows. Send that line to every bidder and compare evidence, not brochures. More background sits in the guides hub.

Can a blast door have a vision panel?

Only if the vision panel was in the tested doorset. A glazed blast door is tested as a complete assembly with its exact glazing, so cutting a vision panel into a solid rated door afterwards takes the door outside its certificate.

Which rating do I need, EPR or EXR?

It depends on the threat. EXR classes come from arena tests with real explosives and suit counter terrorism and hostile vehicle scenarios. EPR classes come from shock tube tests and suit industrial and petrochemical explosions. The threat assessment and the project engineer should set this, not the door supplier.

Can a blast door also be a fire door?

Only if it was also tested to EN 1634-1 and given a fire classification such as E, EW or EI with minutes. Blast testing does not prove fire performance. Ask for the fire test evidence against the same doorset if the opening sits on a compartment line.

Does high rated blast glass make the whole door blast rated?

No. The glass rating covers the glazing, not the door. The leaf, frame and fixings must carry their own EN 13123 or EN 13124 classification for the door to be described as blast resistant.

Can I fit a blast door into an existing wall?

Sometimes, but a structural engineer must confirm the wall can take the load the frame will pass into it. The tested fixing detail names the substrate the evidence covers, so compare it with what is actually there.

Specifying a blast door for a protected opening?Send us the class, the wall build up and whether the door must be glazed, and we will confirm a tested doorset that fits.
Get a free quote

Related

More in guides for specifiers

10 mistakes when specifying certified security doors 10 steps to specify an LPS 1175 door Acceptance and Snagging of a Security Door or Barrier Job Access Control Doors Acoustic Doors: Ratings and Specification After a Forced Entry Attempt: Checking a Security Door Airport Security Doors Anti-Ligature Doors for Mental Health Wards Anti-Ram Bollards Anti-ram gates and barriers: protecting vehicle entrances Arcade Security Doors Explained Automatic Doors Automatic Gates Cost Factors Automatic Vehicle Barriers Ballistic Panels Bank Security Doors Bingo Hall Security Doors Explained Blast protection window film: what it does and what it cannot do Blast resistant windows: what drives the cost and how to specify them Bollard Cost Factors Explained Bollard regulations in the UK: spacing, height and depth Bookmaker Security Doors Explained Builders Merchant Security Doors Bullet Resistant Glass Cost Factors Bullet resistant glass ratings explained: BR1 to BR7 and SG classes Bullet resistant vs bulletproof glass: what the difference means Buying Security Doors and HVM Through Public Frameworks Car Park Security Doors Explained Car Showroom Security Doors Casino Security Doors Explained CDM 2015 Duties When Security Doors, Shutters or HVM Are Installed Cinema Security Doors Cleanroom Doors Cold Store Doors College Security Doors Commissioning, Handover and the O&M Manual for Security Doors and HVM Communal entrance doors for flats: Secured by Design and what to specify Community Centre Security Doors Control Room Doors Court Security Doors Crash Rated Fences and HVM Fencing Explained Data centre physical security: doors, glazing, HVM and shielding by zone Dental Practice Security Doors Depot Security Doors Explained Door Entry Systems Due Diligence When Selecting Vehicle Security Barriers Emergency Exit Doors EMP Shielding Cost Factors Explained Exhibition Centre Fire Door Rules Exhibition Centre Security Doors Factory Security Doors Faraday cage vs RF shielded room: what a business needs FB4 vs FB6 vs FB7: how to choose a ballistic rating Fire and security doors: how dual certification works Fire Compartmentation Fire Curtains Fire Door Certification Fire Door Closers Explained Fire Door Cost Factors Fire Door Duties of the Accountable Person Fire Door Gaps Fire Door Hardware Explained Fire door inspection checklist for steel and timber doors Fire Door Maintenance Fire Door Regulations Care Homes Fire Door Regulations for A and E Departments Fire Door Regulations for Airports Explained Fire Door Regulations for Bowls Clubs Fire door regulations for commercial buildings in the UK Fire Door Regulations for Dialysis Centres Fire Door Regulations for Hockey Clubs Fire Door Regulations for Hospitals Explained Fire Door Regulations for Offices Explained Fire Door Regulations for Operating Theatres Fire Door Regulations for Retail Explained Fire Door Regulations for Schools Explained Fire Door Regulations for Snooker Clubs Fire Door Regulations for Stadiums Fire Door Regulations for Student Accommodation Fire Door Regulations for Warehouses Fire Door Regulations Leisure Centres Fire Door Regulations Restaurants Fire Door Remediation Programme for Housing Providers Fire Door Rules for Badminton Clubs Fire Door Rules for Bingo Halls Fire Door Rules for Bookmakers Fire Door Rules for Bowling Alleys Fire Door Rules for Car Parks Fire Door Rules for Car Showrooms Fire Door Rules for Cinemas Fire Door Rules for Climbing Centres Fire Door Rules for Colleges Fire Door Rules for Community Centres Fire Door Rules for Cricket Clubs Fire Door Rules for Dental Practices Fire Door Rules for Depots Explained Fire Door Rules for Golf Clubs Fire Door Rules for GP Surgeries Fire Door Rules for Gyms Explained Fire Door Rules for Ice Rinks Fire Door Rules for Maternity Units Fire Door Rules for Mental Health Units Fire Door Rules for Museums Fire Door Rules for Oncology Units Fire Door Rules for Opticians Fire Door Rules for Pawnbrokers Fire Door Rules for Petrol Stations Fire Door Rules for Pharmacies Fire Door Rules for Ports Fire Door Rules for Post Offices Fire Door Rules for Prisons Fire Door Rules for Rehabilitation Centres Fire Door Rules for Self Storage Fire Door Rules for Shopping Centres Fire Door Rules for Squash Clubs Fire Door Rules for Supermarkets Fire Door Rules for Swimming Pools Fire Door Rules for Tennis Clubs Fire Door Rules for Theatres Fire Door Rules for UK Arcades Fire Door Rules for UK Casinos Fire Door Rules for UK Hospices Fire Door Rules for Walk-in Centres Fire Door Signage Fire Door Vision Panels Fire Doors and Gateway 2 in Higher-Risk Buildings Fire Rated Glass Cost Explained Fire Rated Sliding Doors Explained Fire Rated Windows Cost Factors Fire Rated Windows Explained Fire Safety Enforcement Notices and Fire Doors: What the Responsible Person Must Do Flat Entrance Doors: PAS 24 and Fire Rated Forced Entry vs Ballistic vs Blast: Which Rating a Site Needs Garage Security Doors Explained Gate Automation Explained Golden Thread Records for Fire Doors GP Surgery Security Doors Explained Gym Security Doors Explained High Speed Doors HMO Fire Doors Hospice Security Doors Explained Hospital Security Doors: Wards, A&E, Plant Hospital Security Gates Hotel Fire Doors Hotel Security Doors How to choose HVM bollards: fixed, shallow mount, removable and automatic How to keep an LPS 1175 door rating valid after installation How to Specify Fire Doors in a Housing Tender How to specify security doors: a checklist for architects How to Verify a Secured by Design Listing How to Verify an LPS 1175 Certificate on Red Book Live How to Write an Operational Requirement for Physical Security HVM planters and street furniture: protection that blends in In-Service Care of Vehicle Security Barriers Installation Handover: LPS 1175 Doors and PAS 68 Barriers Intumescent Seals ISO 16933 explained: EXV and SB classes and hazard ratings ISO 22343 vehicle security barriers explained Keeping a Dual-Certified Fire and Security Door Valid in Service Laboratory Security Doors Layered Security for a Site: Deter, Detect, Delay, Mitigate, Respond Lead Times and Programme Risks for LPS 1175 Doors Leisure Centre Security Doors Library Security Doors Listed Building Fire Doors Loading Bay Doors Explained Lockdown and Access Control Hardware on an LPS 1175 Door LPS 1175 Gates and Grilles Explained LPS 1175 Issue 8 explained: from SR1 to SR8 to A1 to H20 LPS 1175 Roller Shutters LPS 1175 vs ASTM F2781 and Other US Ratings Explained LPS 1175 vs EN 1627: how UK and European burglar resistance ratings compare LPS 1175 vs PAS 24: which security standard does your door need? LPS 1175 Windows and Walling Explained Martyn’s Law and Places of Worship: What a Buyer Checks for Doors and Entry Control Martyn’s Law Enhanced Tier: Physical Measures and the Specifier Brief Martyn’s Law Standard Tier: Procedures, Doors and Shutters Martyn’s Law Timeline and the SIA Regulator Martyn’s Law: what premises must do and which physical measures to consider Master Key Systems MRI and RF shielded rooms: how they work and what to specify Museum Security Doors NPSA Catalogue of Security Equipment (CSE) Explained NPSA Forced Entry and Blast Guidance for Government Sites NPSA Guidance on Lockdown and Marauding Attack: What It Asks of Doors and Entrances Office Security Doors Optician Security Doors Explained Panic Hardware PAS 24 requirements for doors and windows explained PAS 68 Bollard Foundations Explained PAS 68 bollards: ratings, spacing and cost factors PAS 68 vs IWA 14 vs ISO 22343: hostile vehicle mitigation standards explained Pawnbroker Security Doors Explained Pedestrian Gates Petrol Station Security Doors Pharmacy Security Doors Planning Permission for Security Shutters, Gates and Bollards on Commercial Premises Plant room doors: fire, security and ventilation requirements Plant Room Fire Doors Port Security Doors Post Office Security Doors Explained Powder coating vs galvanising vs paint for steel Preliminary Market Engagement for Security Doors and HVM Prison Security Doors Programming a Security Door and Barrier Package on a Live Site Public-Sector Tender Response Checklist for Security Door and HVM Supply Reading a PAS 24 and SBD Door Test Report Regulation 38 Fire Safety Information at Handover for Fire-Rated Security Doorsets Replacing Security Doors in an Occupied Building Restaurant Security Doors Retail Security Doors Revolving Doors RF shielding standards and how shielded rooms are tested Rising Bollard Cost Factors Road Blocker Cost Factors Explained Road Blockers Explained Roller Shutter Cost Factors: What Drives the Price Roller shutter regulations in the UK: safety and maintenance Safe room and panic room doors: specification basics Safety Duties for Powered Doors, Gates and Barriers on Commercial Sites School Security Doors Sectional Doors Secured by Design explained: is it mandatory for doors? Secured by Design vs NPSA vs LPCB: Which One You Need Security Door Locks Security Door Maintenance Checklist Security Doors and Access for Everyone: What Approved Document M Asks Security Doors for A and E Departments Security Doors for Badminton Clubs Security Doors for Bowling Alleys Security Doors for Bowls Clubs Security Doors for Climbing Centres Security Doors for Cricket Clubs Security Doors for Dialysis Centres Security Doors for Golf Clubs Security Doors for Hockey Clubs Security Doors for Ice Rinks Security Doors for Maternity Units Security Doors for Mental Health Units Security Doors for Oncology Units Security Doors for Operating Theatres Security Doors for Rehabilitation Centres Security Doors for Snooker Clubs Security Doors for Squash Clubs Security Doors for Swimming Pools Security Doors for Tennis Clubs Security Doors for Walk-in Centres Security Doors West Midlands Explained Security Fencing Security Gates Cost Factors Explained Security shutters vs high performance roller doors Security shutters vs retractable grilles: which suits retail and commercial openings? Security Turnstiles Explained Security Window Film Security Windows for Schools Explained Self Storage Security Doors Server Room Doors Explained Shopping Centre Security Doors Smoke Control Doors Explained Smoke Curtains Specification Mistakes When Mixing LPS 1175, PAS 24 and SBD in One Tender SR2 vs SR3 vs SR4 security doors: choosing the right LPS 1175 level Stadium Security Doors Steel Door Frames Steel vs aluminium security doors: strength, ratings and looks Steel vs timber fire doors: which suits your building? Student Accommodation Security Doors Substation doors: security, ventilation and specification Supermarket Security Doors Telescopic Bollards Tender Evaluation Criteria and Scoring for Security Doors and HVM The Scope of a Maintenance Contract for Security Doors and Barriers Theatre Security Doors Thermal and Weather Performance of External Security Doorsets Thermally broken steel security doors: U-values and certification Traffic Calming as Hostile Vehicle Mitigation Transport hub security requirements Turnstile Cost Factors Explained Turnstile vs speed gate vs security portal: choosing entrance control Types of security doors for commercial buildings University Security Doors Explained Vehicle Dynamics Assessment: What It Tells the Buyer Before a Barrier Is Specified Warehouse Security Doors Explained Warehouse Security Gates Warranty, Defects Liability and Guarantees for Security Doors and Barriers What affects the cost of a bullet resistant door What affects the cost of a high-security door in the UK Window Security Bars View all →

Products

One supplier for the whole building envelope

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.