ArxBridge
Warehouse Security Gates
Warehouse gate rules: rated gates for yards, loading bays and perimeters, with the vehicle line, automation and one schedule for the whole site.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A warehouse yard never sits still. Lorries reverse into bays, forklifts cross the yard, staff walk between the gatehouse and the doors, and the gates on the boundary decide which of them get in and how fast they leave. The doors on the building hold one line, and the gates on the boundary hold the other.
A gate that stops a lorry and a gate that lets a pedestrian through are two different jobs, and a warehouse that orders one gate for both has ordered the wrong gate twice. The rating, the drive, the control and the gaps beside the gate each belong on the same schedule.
The columns such a schedule needs are set out in our how to specify security doors guide, and the warehouses and logistics sector page covers the buildings the gates protect.
- LPS 1175 B3 / C5 / D10Forced entry ratings, three, five and ten minutes
- ISO 22343-1Vehicle security barrier ratings
- BS EN 12453Safety in use of power operated doors
- ProtectUK 1,200 mm / 500 mmGap cap and height floor on the vehicle line
Yards, loading bays and the perimeter: where a warehouse puts its gates
A warehouse divides into parts that meet traffic in different ways, and each part puts its gates in a different place. The main gate takes the lorries, the service gate takes deliveries and waste, the loading bays take the vehicles that dock against the building, and the pedestrian gate takes the staff who arrive on foot.
The main gate works hardest at shift change, when lorries, vans and staff arrive together. A gate that holds traffic while the reader checks each vehicle needs a lane beside it for the queue, because a lorry held on the public road blocks the road and the gate at once.
Start at the boundary and list every opening a person or a vehicle can use, from the main gate to the gap where the fence meets the wall. A rear gate onto a lane nobody watches after dark faces more risk than the staffed main entrance, so the rating follows the gate, not the warehouse. Our warehouse security doors guide covers the doors on the building itself.
Sliding, swing and cantilever: the gate that fits the opening
A sliding gate runs on a track beside the opening, a swing gate turns on hinges into the yard, and a cantilever gate hangs from a beam above the opening with no track on the ground. Each type suits a different yard, and the ground, the space and the wind decide which one fits.
A sliding gate needs room beside the opening for the leaf to run back, and a track that stays clear of grit, ice and pallets. A swing gate needs room inside the yard for the leaf to open, and a leaf that swings across a slope will drag. A cantilever gate needs no track, so it suits a yard where the ground cannot hold one, but it needs a frame strong enough to carry the leaf from above.
Wind loads the leaf like a sail, so a tall gate on an exposed site needs a drive and fixings that hold it against the gusts the site sees. A pedestrian door beside the vehicle gate keeps staff off the lorry route, and the door goes on the same order as the gate. The sliding vehicle gates page covers the sliding type in full, and the security gates page covers the gate lines.
The vehicle line: ISO 22343-1, mass, speed and penetration
A vehicle barrier earns its rating in a live test, with a vehicle driven at it and the result written into one string. Cars from a 1,500 kg car up to trucks of 30,000 kg are driven at 48, 64 or 80 km/h, and the string records the vehicle class, the speed, the angle and the penetration, so a rating such as V/7500[N3]/80/90:0/0 can be written straight onto the schedule for the approach.
A schedule that still names PAS 68 names a standard no test house issues against now, so ISO 22343-1:2023 is the name the order should carry. The change from PAS 68 and IWA 14-1 to the current standard is worked through in our HVM standards guide, and the ratings in full are in our ISO 22343 vehicle security barriers guide.
The gap beside a barrier and the height of the barrier both belong on the schedule, because ProtectUK guidance puts a 1,200 mm cap on the clear gap and a 500 mm floor under the height. Leave a wider gap and a vehicle slips past the barrier, and fit a lower barrier and a vehicle climbs it. The hostile vehicle mitigation page covers the line in full, and our anti-ram gates and barriers guide works through the options.
The gate that fits the yard: sliding, swing and cantilever
A warehouse yard takes the gate that fits its opening, and each type suits a different yard. A sliding gate runs along the fence line where there is room to slide, a swing gate opens inward where the yard is deep enough to take the swing, and a cantilever gate hangs clear of the ground. The gate on the order should name the type beside the opening, so the gate that arrives fits the yard it guards.
The vehicle line is the line a vehicle could drive through, and it is proved to ISO 22343-1, which supersedes PAS 68:2013. The test runs a vehicle of a set mass at a set speed into the barrier and measures how far it gets through, with masses from a 1,500 kg car to a 30,000 kg truck and speeds of 48, 64 or 80 km/h. The rating on the order names the mass, the speed and the penetration together.
The gaps between the gates need bollards and barriers of their own, because a line that stops a vehicle at the gate and leaves it open at the kerb is no line at all. The spacing on the line follows ProtectUK, with no more than 1,200 mm clear between bollards and a minimum height of 500 mm.
Access control for vehicles and staff must open for the lorries, the vans and the people who need the yard, and stay shut for the rest. The reader, the intercom and the fail safe state belong on the order beside the gate, and the fail position must be written on the order.
Powered gates and the alarm: what must open when the building empties
Powered gates must still open in an emergency, because the yard empties through the gate when the alarm sounds. The safety of a powered gate is proved to EN 12453, which sets out how a gate must behave when a person or a vehicle is in its path, and the release that lets the gate open by hand belongs on the schedule beside the motor.
The gate on the escape route must open when the alarm sounds, and it must open without a key, a code or a card. The release is tested on the round by sounding the alarm and watching the gate open.
The rooms the public never sees take a different gate from the yard, because the stores and the plant behind them hold a heavier fire load. A gate on a fire route takes the period the fire load behind it demands, so most gates take FD30 and the heaviest loads take FD60.
The round that looks after warehouse gates walks the yard, the loading bays and the perimeter in turn and looks at the motors, the rails, the locks and the release. Each fault is written against the gate it belongs to on the same day, with the part and the date beside it, so the repair follows the fault and the yard never stands open.
| Position | Gate | Rating | What to check |
|---|---|---|---|
| Main entrance | Sliding gate | ISO 22343-1 | Motor, rail, release |
| Loading bay | Cantilever gate | ISO 22343-1 | Motor, rail, lock |
| Staff entrance | Swing gate | LPS 1175 B3 | Hinges, lock, closer |
| Escape route | Swing gate | Release on alarm | Release, hinges, gap |
Put the rating, the motor and the release on the same line as every warehouse gate on the order, so the gate that arrives is the gate that was tested. The ratings in full are set out in our ISO 22343 vehicle security barriers guide, and the rated options for the gate line are covered in our anti-ram gates and barriers guide. The automation, the safety and the release are covered in our gate automation guide, and the fences that close the line beside the gates are covered in our crash rated fences and HVM fencing guide.
The gaps between the gates: bollards, barriers and the kerb line
A gate line is only as strong as the gaps beside it. Bollards fill the space between the gate post and the wall, between the gate and the fence, and along the pavement where a vehicle could mount the kerb, so the line runs unbroken from one end of the boundary to the other.
Fixed bollards suit a gap that never needs to open, rising bollards suit a gap that must open for a vehicle and close behind it, and road blockers suit a lane where a vehicle must be stopped, not just slowed. The rating for that line comes from the vehicle test, not from the bollard alone, and our road blockers guide covers the blockers that rise from the road.
Foundations carry the rating as much as the bollard does. A bollard set in a shallow foundation pulls out under the load it was meant to stop, so the foundation depth and the fixings belong on the schedule beside the bollard. Our choosing HVM bollards guide works through the options, the security bollards page covers the bollards themselves, and the rising bollards page covers the type that rises from the road.
Powered gates that must still open in an emergency: automation, safety and the release
A powered gate moves a heavy leaf on a motor, so the safety of the people beside it belongs in the specification beside the drive. BS EN 12453 sets out the safety in use of power operated doors, and the devices on the gate, photocells, safety edges and force limits, are what keep a person clear of the leaf while it moves.
When the alarm sounds, the gate line must let people out. The release on alarm belongs on the inspection round beside the reader, because a gate that stays shut in an evacuation has failed the one job it was fitted for, and the release must work when the power is gone as well as when the alarm sounds. Our gate automation guide covers how a gate is driven, and the turnstile versus speed gate versus portal guide works through which lane suits which entrance.
Access control for vehicles and staff: who passes the gate
Access control at a warehouse gate decides which vehicles and which people pass, and when. Lorries take a tag or a number plate read, staff take a card or a fob, and a visitor with no card takes the intercom at the gatehouse, because a visitor with no other way in needs a voice at the gate.
One system should run the whole site, not one system per gate. A card that opens the main gate should open the staff areas and the service yard as well, and the office that issues the cards should be able to stop one card without stopping the rest. Readers, fobs and biometrics in the lane are covered in our security turnstiles guide.
Deliveries need a route that keeps them off the pedestrian paths. A delivery vehicle that shares a lane with staff on foot puts people beside reversing lorries, so the gate plan should separate the two, with the pedestrian gate on its own path and the vehicle gate on its own lane. The loading bay doors guide covers the bays where the vehicles dock.
The gate on the escape route: what must open when the alarm sounds
A gate that sits on an escape route must open when the alarm sounds, and the release belongs in the specification beside the reader. A pedestrian gate beside the vehicle gate gives staff a way out that does not cross the lorry lane, and the gate on the route should open in one push, without a key and without a card.
The personnel door beside the gate can carry FD30 where the route needs it, with a 4 mm gap round the leaf and a smoke seal proved to BS EN 1634-3. The closer on that door must pull the leaf shut every time, with no fire door taking less than EN 3 to BS EN 1154, and the grades and the parts behind a working fire door are covered in our fire door hardware guide.
Test the release on every inspection round, because a gate that worked last month may not work this one. The record should name the gate, the release, the test and the date, so the next team can see what was checked and what was fixed. What each check looks for is set out in the fire door inspection checklist.
Ordering for the whole site: one schedule, every gate on it
Set the enquiry out as a specification, one line for every gate on the site. Each line names the position, the gate type, the forced entry rating, the vehicle rating where one is needed, the drive and the access control, and the leaf, the frame, the fixings and the hardware as one assembly. Where a gate must resist a vehicle as well as a person, ask for the rating on the whole line, not on the leaf alone.
File the test report, the rating and the drive specification with the gate when it arrives, and write the inspection routine into the handover pack, so the record covers the whole life of the line. The keeping an LPS 1175 rating valid guide sets out what breaks a rating, and our security gates cost factors guide works through what each step up the line adds to the build.
| Position | Gate | Rating | What to check |
|---|---|---|---|
| Main vehicle gate | Sliding gate | ISO 22343-1 | Drive, safety devices, release |
| Loading bay gate | Swing gate | LPS 1175 C5 | Lock, hinges, closer |
| Pedestrian gate | Swing security gate | LPS 1175 B3 | Reader, closer, latch |
| Service yard gate | Cantilever gate | LPS 1175 B3 | Motor, fixings, release |
| Perimeter gaps | Bollards and barriers | ISO 22343-1 | Spacing, height, foundations |
A warehouse gate guards the yard, the bays and the building behind them, so the vehicle rating, the automation and the gaps beside the gate must all sit on the same schedule.
What security rating do warehouse gates need?
The site decides, by the attack each gate could face. A pedestrian gate often takes B3, a loading bay gate takes C5, and the vehicle line takes its own rating to ISO 22343-1, with the risk assessment naming the rating for each gate.
Can a warehouse gate stop a vehicle?
Only where the line carries a vehicle rating. ISO 22343-1 proves a barrier against vehicles from a 1,500 kg car to a 30,000 kg truck, at 48, 64 or 80 km/h, and the rating must name the whole line, not the gate leaf alone.
Do powered warehouse gates need to release on alarm?
Yes. A powered gate must release when the alarm sounds and fail safe when the power goes, so people can still leave, and the release belongs on the inspection round beside the reader.
What fills the gaps beside a warehouse gate?
Bollards and barriers, carrying the same vehicle rating as the gate. ProtectUK guidance caps the clear gap at 1,200 mm and sets the minimum height at 500 mm, so a wider gap lets a vehicle through beside the gate.
Who checks warehouse security gates?
The site team, on the routine the security plan sets. Each record names the gate, the fault, the repair and the date it was fixed.
Get a free quote
Related
More in guides for specifiers
Products
One supplier for the whole building envelope
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.