Certified physical security

ArxBridge
High street shopfronts with a roller shutter and a retractable grille

ArxBridge

Security shutters vs retractable grilles: which suits retail and commercial openings?

Security shutters or retractable grilles for retail and commercial openings? Compare ratings, appearance, noise, planning and upkeep across the UK.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed across the UK
Prefer to talk?+44 7352 267239

Get a free project quote

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Choose shutters where the priority is a solid barrier and a tidy appearance; choose retractable grilles where visibility into the display matters and there is no room for a shutter box. Both can be specified to LPS 1175 ratings. The right choice follows the opening, the planning constraints and what the insurer expects to see.

  • Security shuttersSolid or perforated curtain that coils above the opening
  • Retractable grillesSee-through lattice that folds or slides aside
  • RatingsBoth can be specified to LPS 1175 SR ratings
  • PlanningExternal shutters often need permission; internal grilles rarely do

What each product is

A security shutter is a curtain of interlocking steel or aluminium slats that rolls up into a coil housed in a box above the opening. Closed, it covers the opening completely; open, it disappears into the box and the shopfront looks untouched. Slats come solid, perforated or punched, which changes how much can be seen through the closed shutter. Our security shutters page describes the build in detail.

A retractable grille is built from steel links or rods in a lattice or brick pattern that you can see through. It runs in guides and folds or slides to one side when the premises open, stacking into a fraction of the opening width. Because it does not need a coil box, it suits openings with limited headroom. Our retractable security grilles page covers the construction.

The two are sometimes combined on one site: shutters on the rear service doors where appearance matters less, grilles on the glazed frontage where the display should stay visible. Treat each opening on its own merits rather than picking one product for the whole building.

If a roller door is also on the shortlist, the comparison widens. Our guide comparing security shutters vs high performance roller doors covers speed, security and use.

LPS 1175 ratings for shutters and grilles

Both product types can be tested to LPS 1175, the LPCB forced entry standard. The rating combines a tool category letter with the minutes of resistance: A1 for basic hand tools, B3 for tools such as screwdrivers and hand saws over three minutes, C5 for crowbars and drills over five minutes, and D10 for heavy tools such as sledgehammers and disc cutters over ten minutes. Our LPS 1175 guide explains the full table.

Ask for the test evidence for the exact product and rating, not a general claim about the range. A shutter tested to C5 and a grille tested to B3 are different propositions, and the rating applies to the tested construction including its guides, locks and fixings. The rating of the curtain alone means little if the guides can be prised from the wall.

Match the rating to the threat and the location. A high street jeweller and a suburban convenience store face different risks, and the rear of a building usually needs a higher rating than the front, because attacks there go unseen for longer. Where the risk assessment is unclear, our security consultancy service can define the threat before you specify.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

The shutter that must also hold fire: two proofs on one opening

A shutter and a grille guard the same frontage in different ways. The shutter covers the whole opening after hours, while the grille lets light and air through and still bars the way, so the choice follows what the frontage must do when the shop is shut. The shutters themselves are covered on our security shutters page.

Forced entry is proved to LPS 1175 for both, with B3 holding three minutes, C5 holding five minutes and D10 holding ten minutes, all under Issue 8.2, dated September 2024. The rating on the order should match the goods behind the frontage, not the shutter the catalogue shows first.

A fire shutter is not a security shutter. Where the opening needs both, the fire proof and the forced entry proof sit on separate lines, each proved on its own test, fire to EN 1634-1 and forced entry to LPS 1175, because one test report cannot prove both.

A powered shutter is a machine, and BS EN 12453 sets out how it must be made safe to use. Photocells, safety edges and loops each stop the shutter when a person or a vehicle is in its way, and a shutter without them has no proven safety at all. The rules the shutter must meet are set out in our roller shutter regulations guide.

Retractable or fixed: the grille that fits the frontage

A retractable grille folds away by day and closes tight at night, so the shop keeps its open front while it trades and its barred front after hours. The tracks, the lock and the fixings belong on the order beside the grille, because a grille that folds is only as strong as the track it runs on.

A fixed grille stays in place, so it suits a window or a vent that never opens. The frame it fixes to must hold the rating, because a grille fixed to a weak frame has no proof, and the test report must name the whole assembly as fitted.

The grille lets the shop breathe after hours, while the shutter seals it shut, so a shop that needs air through the frontage takes a grille and a shop that needs the frontage closed takes a shutter. The choice belongs on the order beside the rating, because a shutter ordered for a frontage that needs air leaves the shop to cook behind it.

Planning and conservation areas can limit what the frontage may carry. A shutter box on a listed frontage needs approval before the order is placed, so the approval belongs on the file beside the rating, and the order should wait for it.

Ask for the test report before the order is placed, with the rating, the assembly and the fixings named on the same line. A report that names the shutter alone leaves the frame and the fixings unproved, and the frontage that arrives is not the frontage that was tested. The bays that feed the frontage are covered in our loading bay doors guide.

Product What it guards Rating What to check
Roller shutter Whole frontage LPS 1175 B3 Fixings, motor, safety devices
Retractable grille Shopfront LPS 1175 B3 Tracks, lock, fixings
Fixed grille Window or vent LPS 1175 B3 Frame, fixings
Fire shutter Compartment opening FD30 or FD60 Seals, closer, release

Put the product, the rating and the fixings on one schedule line, so whoever reads the file next can see what was tested and what holds it. What each step up the scale adds to the build is worked through in our roller shutter cost factors guide.

Visibility and appearance after hours

This is where the two products differ most. A closed solid shutter blanks the shopfront completely: nothing can be seen in, and the street loses an active frontage overnight. Perforated or punched slats soften this by letting light and partial views through, so the display stays faintly visible and the frontage keeps some life.

A retractable grille keeps the window display visible after closing, which suits retailers who trade on presentation. The lattice reads as a security layer rather than a closed shop, and window lighting can stay on behind it. The trade off is that stock remains on show, so the grille must be backed by a sensible display policy: high value goods come out of the window at night.

By day the difference is smaller. A shutter hides in its box above the opening; a grille stacks to one side in a slim bundle. Both leave the trading frontage clear, though the grille’s stacked bundle and its floor track remain visible. Where the shutter box cannot be concealed, for example under a low fascia, the grille’s smaller footprint can decide the matter.

Noise, ventilation and daily use

Roller shutters make noise. The curtain rattles in its guides as it moves, and a large shutter closing at the end of the day is heard through the building. Perforated slats tend to run louder than solid ones, and a shutter that is slightly out of adjustment gets louder still. In flats above shops this matters, and it is worth raising at the survey.

Grilles run quieter because there is less metal moving in guides, and they need less headroom to operate. Ventilation is another practical difference: a closed solid shutter seals the opening, while a grille lets air move through, which helps where the opening also serves as ventilation for the space behind. The comparison table below summarises the practical points.

Aspect Security shutters Retractable grilles
Visibility after hours Solid slats block the view; perforated slats allow partial views Display stays visible through the lattice
Appearance by day Curtain hidden in the coil box above Grille stacks to one side in a slim bundle
Headroom needed Room for the coil box above the opening Little headroom; needs stacking space at the side
Ventilation when closed Solid curtain seals the opening Air moves through the lattice
Noise in operation Audible rattle in the guides Quieter in daily use
Test evidence Ask for the LPS 1175 rating on the test certificate Ask for the LPS 1175 rating on the test certificate

Planning permission and conservation areas

External shutters often need planning permission, and in conservation areas or on listed buildings the planners take a close interest. Councils generally dislike solid shutters that blank off shop windows outside opening hours, because a row of closed shutters deadens the street. Perforated shutters or internal grilles are usually received better, but every authority applies its own policy, so check before ordering.

Internal grilles and internal shutters rarely need planning permission, since they do not alter the external appearance of the building. Listed building consent is a separate question and can still apply to internal work. If the building is listed, assume consent is needed and confirm it early.

Fit the product inside wherever the opening allows it. An internal shutter or grille is out of the weather, out of reach of graffiti, keeps the shopfront looking like a shopfront, and sidesteps most planning objections in one move. External mounting is for openings with no internal room for the coil or the stack, or where the glass itself must be protected from impact.

Insurance and test evidence

Insurers take an interest in physical security, and some policies name the standard the products must meet. Read the policy wording before specifying: it may ask for products tested to a named standard such as LPS 1175, and it may set a minimum rating. Specifying above the minimum is straightforward; discovering the requirement after installation is not.

Keep the test evidence with the policy documents. The certificate should name the product, the standard and the rating achieved, and it should come from third party testing, not from the manufacturer’s own claims. Photographs of the installed product, showing the guides, locks and fixings, complete the file.

An insurer may also ask about the alarm and how it interacts with the shutter or grille. An internal grille works well with an alarm: the intruder must break glass first, which triggers the alarm, and still faces the grille. Tell the insurer how the layers work together rather than listing products in isolation.

Fit inside where you can. An internal shutter or grille avoids most planning objections, stays out of the weather and works with the alarm instead of against it. External mounting should be the exception, not the default.

Operation, maintenance and the glass behind

Both products are used daily, sometimes several times a day, so the operation must suit the staff. Manual shutters need a steady pull and a working lock; anything stiff gets left half open. Electric operation with a key switch or remote suits large or heavy curtains and removes the excuse for leaving the shutter up. Grilles are lighter to move by hand, but the lattice must run freely in its tracks.

Maintenance is simple but regular: keep guides and tracks clear of debris, check the locks, and have the curtain or lattice inspected at planned intervals. Maintenance covers shutters and grilles alongside doors and gates, and is done by our own team or by our installation partners. A shutter that is serviced lasts; one that is ignored gets noisy, then stiff, then stuck.

Remember what each product does not do. A grille stops entry but does not protect the glass: a thrown object can still reach the window through the lattice. Where the glass itself must survive impact, the glazing needs its own specification, and our security windows page explains the options. In retail projects the glass, the grille and the alarm should be specified as one layered design, not three separate purchases. In hospitals the clinical rooms need a different kind of enclosure altogether, covered in our guide to MRI and RF shielded rooms; and where the opening protects people rather than stock, for example a staff refuge, see our guide to safe room and panic room doors. You can browse all our guides for related reading.

Safety and maintenance rules apply however the opening is secured. Our guide to roller shutter regulations in the UK covers powered doors, safety devices and servicing.

Frequently asked questions

Do I need planning permission for a security shutter?

Often, for an external shutter, and especially in conservation areas or on listed buildings. Internal shutters and grilles rarely need planning permission, though listed building consent can still apply. Check with the local authority before ordering.

Can a grille be as strong as a shutter?

It can carry the same kind of rating. Both product types are tested to LPS 1175, so compare the ratings on the test certificates rather than assuming the solid product is stronger. The fixings and guides matter as much as the curtain or lattice.

Do shutters or grilles stop the glass being broken?

A solid shutter protects the glass behind it; a grille does not, because objects can pass through the lattice. If the glazing itself must resist impact, specify the glass separately.

How noisy are roller shutters in daily use?

Audibly. The curtain rattles in its guides, and perforated slats run louder than solid ones. In buildings with flats above, raise noise at the survey and keep the shutter adjusted and serviced.

What maintenance do shutters and grilles need?

Keep guides and tracks clear, check locks regularly, and have the product inspected at planned intervals. Daily-use products that are ignored become stiff and unreliable.

Which suits your openings?Send us the opening sizes and a photo of each frontage and we will recommend the right product and rating.
Get a free quote

Related

More in guides for specifiers

10 mistakes when specifying certified security doors 10 steps to specify an LPS 1175 door Acceptance and Snagging of a Security Door or Barrier Job Access Control Doors Acoustic Doors: Ratings and Specification After a Forced Entry Attempt: Checking a Security Door Airport Security Doors Anti-Ligature Doors for Mental Health Wards Anti-Ram Bollards Anti-ram gates and barriers: protecting vehicle entrances Arcade Security Doors Explained Automatic Doors Automatic Gates Cost Factors Automatic Vehicle Barriers Ballistic Panels Bank Security Doors Bingo Hall Security Doors Explained Blast doors: glazed vs solid and how they are rated Blast protection window film: what it does and what it cannot do Blast resistant windows: what drives the cost and how to specify them Bollard Cost Factors Explained Bollard regulations in the UK: spacing, height and depth Bookmaker Security Doors Explained Builders Merchant Security Doors Bullet Resistant Glass Cost Factors Bullet resistant glass ratings explained: BR1 to BR7 and SG classes Bullet resistant vs bulletproof glass: what the difference means Buying Security Doors and HVM Through Public Frameworks Car Park Security Doors Explained Car Showroom Security Doors Casino Security Doors Explained CDM 2015 Duties When Security Doors, Shutters or HVM Are Installed Cinema Security Doors Cleanroom Doors Cold Store Doors College Security Doors Commissioning, Handover and the O&M Manual for Security Doors and HVM Communal entrance doors for flats: Secured by Design and what to specify Community Centre Security Doors Control Room Doors Court Security Doors Crash Rated Fences and HVM Fencing Explained Data centre physical security: doors, glazing, HVM and shielding by zone Dental Practice Security Doors Depot Security Doors Explained Door Entry Systems Due Diligence When Selecting Vehicle Security Barriers Emergency Exit Doors EMP Shielding Cost Factors Explained Exhibition Centre Fire Door Rules Exhibition Centre Security Doors Factory Security Doors Faraday cage vs RF shielded room: what a business needs FB4 vs FB6 vs FB7: how to choose a ballistic rating Fire and security doors: how dual certification works Fire Compartmentation Fire Curtains Fire Door Certification Fire Door Closers Explained Fire Door Cost Factors Fire Door Duties of the Accountable Person Fire Door Gaps Fire Door Hardware Explained Fire door inspection checklist for steel and timber doors Fire Door Maintenance Fire Door Regulations Care Homes Fire Door Regulations for A and E Departments Fire Door Regulations for Airports Explained Fire Door Regulations for Bowls Clubs Fire door regulations for commercial buildings in the UK Fire Door Regulations for Dialysis Centres Fire Door Regulations for Hockey Clubs Fire Door Regulations for Hospitals Explained Fire Door Regulations for Offices Explained Fire Door Regulations for Operating Theatres Fire Door Regulations for Retail Explained Fire Door Regulations for Schools Explained Fire Door Regulations for Snooker Clubs Fire Door Regulations for Stadiums Fire Door Regulations for Student Accommodation Fire Door Regulations for Warehouses Fire Door Regulations Leisure Centres Fire Door Regulations Restaurants Fire Door Remediation Programme for Housing Providers Fire Door Rules for Badminton Clubs Fire Door Rules for Bingo Halls Fire Door Rules for Bookmakers Fire Door Rules for Bowling Alleys Fire Door Rules for Car Parks Fire Door Rules for Car Showrooms Fire Door Rules for Cinemas Fire Door Rules for Climbing Centres Fire Door Rules for Colleges Fire Door Rules for Community Centres Fire Door Rules for Cricket Clubs Fire Door Rules for Dental Practices Fire Door Rules for Depots Explained Fire Door Rules for Golf Clubs Fire Door Rules for GP Surgeries Fire Door Rules for Gyms Explained Fire Door Rules for Ice Rinks Fire Door Rules for Maternity Units Fire Door Rules for Mental Health Units Fire Door Rules for Museums Fire Door Rules for Oncology Units Fire Door Rules for Opticians Fire Door Rules for Pawnbrokers Fire Door Rules for Petrol Stations Fire Door Rules for Pharmacies Fire Door Rules for Ports Fire Door Rules for Post Offices Fire Door Rules for Prisons Fire Door Rules for Rehabilitation Centres Fire Door Rules for Self Storage Fire Door Rules for Shopping Centres Fire Door Rules for Squash Clubs Fire Door Rules for Supermarkets Fire Door Rules for Swimming Pools Fire Door Rules for Tennis Clubs Fire Door Rules for Theatres Fire Door Rules for UK Arcades Fire Door Rules for UK Casinos Fire Door Rules for UK Hospices Fire Door Rules for Walk-in Centres Fire Door Signage Fire Door Vision Panels Fire Doors and Gateway 2 in Higher-Risk Buildings Fire Rated Glass Cost Explained Fire Rated Sliding Doors Explained Fire Rated Windows Cost Factors Fire Rated Windows Explained Fire Safety Enforcement Notices and Fire Doors: What the Responsible Person Must Do Flat Entrance Doors: PAS 24 and Fire Rated Forced Entry vs Ballistic vs Blast: Which Rating a Site Needs Garage Security Doors Explained Gate Automation Explained Golden Thread Records for Fire Doors GP Surgery Security Doors Explained Gym Security Doors Explained High Speed Doors HMO Fire Doors Hospice Security Doors Explained Hospital Security Doors: Wards, A&E, Plant Hospital Security Gates Hotel Fire Doors Hotel Security Doors How to choose HVM bollards: fixed, shallow mount, removable and automatic How to keep an LPS 1175 door rating valid after installation How to Specify Fire Doors in a Housing Tender How to specify security doors: a checklist for architects How to Verify a Secured by Design Listing How to Verify an LPS 1175 Certificate on Red Book Live How to Write an Operational Requirement for Physical Security HVM planters and street furniture: protection that blends in In-Service Care of Vehicle Security Barriers Installation Handover: LPS 1175 Doors and PAS 68 Barriers Intumescent Seals ISO 16933 explained: EXV and SB classes and hazard ratings ISO 22343 vehicle security barriers explained Keeping a Dual-Certified Fire and Security Door Valid in Service Laboratory Security Doors Layered Security for a Site: Deter, Detect, Delay, Mitigate, Respond Lead Times and Programme Risks for LPS 1175 Doors Leisure Centre Security Doors Library Security Doors Listed Building Fire Doors Loading Bay Doors Explained Lockdown and Access Control Hardware on an LPS 1175 Door LPS 1175 Gates and Grilles Explained LPS 1175 Issue 8 explained: from SR1 to SR8 to A1 to H20 LPS 1175 Roller Shutters LPS 1175 vs ASTM F2781 and Other US Ratings Explained LPS 1175 vs EN 1627: how UK and European burglar resistance ratings compare LPS 1175 vs PAS 24: which security standard does your door need? LPS 1175 Windows and Walling Explained Martyn’s Law and Places of Worship: What a Buyer Checks for Doors and Entry Control Martyn’s Law Enhanced Tier: Physical Measures and the Specifier Brief Martyn’s Law Standard Tier: Procedures, Doors and Shutters Martyn’s Law Timeline and the SIA Regulator Martyn’s Law: what premises must do and which physical measures to consider Master Key Systems MRI and RF shielded rooms: how they work and what to specify Museum Security Doors NPSA Catalogue of Security Equipment (CSE) Explained NPSA Forced Entry and Blast Guidance for Government Sites NPSA Guidance on Lockdown and Marauding Attack: What It Asks of Doors and Entrances Office Security Doors Optician Security Doors Explained Panic Hardware PAS 24 requirements for doors and windows explained PAS 68 Bollard Foundations Explained PAS 68 bollards: ratings, spacing and cost factors PAS 68 vs IWA 14 vs ISO 22343: hostile vehicle mitigation standards explained Pawnbroker Security Doors Explained Pedestrian Gates Petrol Station Security Doors Pharmacy Security Doors Planning Permission for Security Shutters, Gates and Bollards on Commercial Premises Plant room doors: fire, security and ventilation requirements Plant Room Fire Doors Port Security Doors Post Office Security Doors Explained Powder coating vs galvanising vs paint for steel Preliminary Market Engagement for Security Doors and HVM Prison Security Doors Programming a Security Door and Barrier Package on a Live Site Public-Sector Tender Response Checklist for Security Door and HVM Supply Reading a PAS 24 and SBD Door Test Report Regulation 38 Fire Safety Information at Handover for Fire-Rated Security Doorsets Replacing Security Doors in an Occupied Building Restaurant Security Doors Retail Security Doors Revolving Doors RF shielding standards and how shielded rooms are tested Rising Bollard Cost Factors Road Blocker Cost Factors Explained Road Blockers Explained Roller Shutter Cost Factors: What Drives the Price Roller shutter regulations in the UK: safety and maintenance Safe room and panic room doors: specification basics Safety Duties for Powered Doors, Gates and Barriers on Commercial Sites School Security Doors Sectional Doors Secured by Design explained: is it mandatory for doors? Secured by Design vs NPSA vs LPCB: Which One You Need Security Door Locks Security Door Maintenance Checklist Security Doors and Access for Everyone: What Approved Document M Asks Security Doors for A and E Departments Security Doors for Badminton Clubs Security Doors for Bowling Alleys Security Doors for Bowls Clubs Security Doors for Climbing Centres Security Doors for Cricket Clubs Security Doors for Dialysis Centres Security Doors for Golf Clubs Security Doors for Hockey Clubs Security Doors for Ice Rinks Security Doors for Maternity Units Security Doors for Mental Health Units Security Doors for Oncology Units Security Doors for Operating Theatres Security Doors for Rehabilitation Centres Security Doors for Snooker Clubs Security Doors for Squash Clubs Security Doors for Swimming Pools Security Doors for Tennis Clubs Security Doors for Walk-in Centres Security Doors West Midlands Explained Security Fencing Security Gates Cost Factors Explained Security shutters vs high performance roller doors Security Turnstiles Explained Security Window Film Security Windows for Schools Explained Self Storage Security Doors Server Room Doors Explained Shopping Centre Security Doors Smoke Control Doors Explained Smoke Curtains Specification Mistakes When Mixing LPS 1175, PAS 24 and SBD in One Tender SR2 vs SR3 vs SR4 security doors: choosing the right LPS 1175 level Stadium Security Doors Steel Door Frames Steel vs aluminium security doors: strength, ratings and looks Steel vs timber fire doors: which suits your building? Student Accommodation Security Doors Substation doors: security, ventilation and specification Supermarket Security Doors Telescopic Bollards Tender Evaluation Criteria and Scoring for Security Doors and HVM The Scope of a Maintenance Contract for Security Doors and Barriers Theatre Security Doors Thermal and Weather Performance of External Security Doorsets Thermally broken steel security doors: U-values and certification Traffic Calming as Hostile Vehicle Mitigation Transport hub security requirements Turnstile Cost Factors Explained Turnstile vs speed gate vs security portal: choosing entrance control Types of security doors for commercial buildings University Security Doors Explained Vehicle Dynamics Assessment: What It Tells the Buyer Before a Barrier Is Specified Warehouse Security Doors Explained Warehouse Security Gates Warranty, Defects Liability and Guarantees for Security Doors and Barriers What affects the cost of a bullet resistant door What affects the cost of a high-security door in the UK Window Security Bars View all →

Products

One supplier for the whole building envelope

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.