ArxBridge
Dental Practice Security Doors
A dental practice holds controlled drugs, costly equipment and patient records behind its doors, so each leaf takes the grade the room behind it demands.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A dental practice is a small healthcare building where patients sit behind closed doors and the drugs and records stay behind locked ones. The reception serves the public, the surgeries hold the patients, and the stores hold what the practice runs on. The grade on each door follows the room behind the leaf, because the rooms hold different things.
The practice order names the grade beside each opening, so the door that arrives is the door the room needs. Without that schedule a leaf may land in the wrong room, and a leaf in the wrong room guards the wrong thing.
The rules for the shared parts of a small healthcare building sit beside the retail rules, and the hospital security doors guide shows how a larger healthcare building guards its stores. The practice order names every door in the building, with the grade and the lock beside each one.
- LPS 1175 B3 / C5 / D10Forced entry grades to Issue 8.2
- Controlled drugsWhat the drugs store holds
- FD30 / FD60Fire periods to EN 1634-1
- One listEvery practice door named
Reception, surgeries and stores: one practice, three grades
A dental practice works in three parts, and the grade follows the part. Reception faces the public, the surgeries hold the patients, and the stores hold what the practice runs on, so a door between one part and the next must hold the line between them.
Reception takes the doors the public sees, and each leaf must open for the staff who work behind it and shut behind them. The surgeries take the doors the public never sees, and each leaf must hold against the attack the drugs and equipment behind it invite. The stores take the doors that guard what the practice runs on, and each leaf takes the grade the value behind it demands.
Before the order goes out, the practice writes one schedule that names every opening with the grade beside it. A leaf that arrives with no line on the schedule cannot be placed, because nobody knows which room it was ordered for, so the schedule is finished before the order is placed.
The surgery door: the leaf that guards the patient and the drugs
The surgery leaf carries one of the highest grades in the practice, because the room behind it holds the patient, the drugs and the equipment. Leaf, frame, fixings and lock are proved together as one doorset, and the test report names each part, so the door that arrives matches the door that was proved.
A pane in the surgery leaf lets the nurse see the patient before the leaf opens, and the pane carries the same proof as the leaf itself, because a leaf that holds while its pane gives way has held nothing. The bead and the fixings that hold the pane are the ones the test report names.
One surgery leaf can carry both proofs at once, because the room behind it needs fire held back and an intruder held out. EN 1634-1 proves the fire side in E, EW and EI from 30 to 120 minutes, and LPS 1175 proves the forced entry side in B3, C5 and D10. Both proofs are run on the same leaf, frame and seals together, so the one doorset carries the report for both jobs.
Controlled drugs and patient records: the rooms that take the highest grade
Controlled drugs sit behind the drugs store leaf, and the grade on that leaf follows what the room holds. A room that holds drugs takes a higher category than a room that holds shelves, because the intruder who tries the drugs store is after what the practice cannot replace cheaply, and the leaf must hold long enough for the alarm to be answered.
Two ratings sit side by side in the LPS 1175 versus PAS 24 guide, and what breaks a rating once a door is fitted is named in the keeping an LPS 1175 rating valid guide. A leaf proved to B3 on an opening that needs C5 is a different door from the one the practice ordered.
The three categories carried the names SR2, SR3 and SR4 before Issue 8, and the order carries whichever name the product was proved under. A door ordered as LPS 1175 is ordered as LPS 1175 alone, because no published table turns one standard’s rating into another’s.
The reception counter: the leaf the public meets first
The counter door takes the staff from reception to the surgeries, and the public never passes it. The leaf opens for a member of staff with their hands full and shuts behind them without a hand on it, because a leaf left standing open is a door that guards nothing.
The lock on the counter door takes a reader beside the leaf, so the leaf opens for the dentist and no one else, and the list behind the reader decides which fob opens which door. The door entry systems guide covers the entry system beside the leaf.
The counter leaf has to shut quietly after every member of staff who passes through it. Its closer is set to pull the leaf home without a slam, and the fitting is proved by opening the leaf and seeing it come home on its own. The fire door closers guide works through the sizes and the fitting of closers, and the fire door hardware guide covers the lock the key turns.
Locks, readers and the hatch: how staff move through the practice
The staff route through a dental practice runs from reception through the counter to the surgeries and back, and each leaf on the route opens for staff and stays shut for the public. A reader beside each leaf opens it for the fob that belongs to it, and the list behind the readers names which fob opens which door.
The hatch beside the counter takes the impressions out and the stock in, and it takes a leaf of its own, with a lock that holds it shut when the practice is closed. A hatch left open is an opening like any other, so the hatch belongs on the schedule beside the doors.
The force to open a leaf on the staff route stays below 30 N for the first 30 degrees of travel and below 22.5 N beyond, under BS 8300 and Approved Document M, because staff move through the practice with their hands full. A leaf that is hard to open slows the staff who serve the surgeries, and a leaf that will not shut leaves the surgery open.
Glass, light and privacy: glazed leaves in a surgery
A surgery needs light and privacy at once, and the glazed leaves carry both. The pane lets the nurse see the corridor without opening the leaf, and it lets the dentist see who waits outside, so the leaf must hold its proof while letting the light through. The bead and the fixings the test report names go on the order beside the glass, and the frame beside the leaf takes the same proof.
A vision panel on a surgery door lets the dentist see the patient without opening the leaf, and it lets a patient see whether the surgery is in use before the leaf opens. The pane in the leaf carries the same proof as the leaf itself, because a leaf that holds while its pane gives way has held nothing. The fire rated glass cost guide works through what the glass itself costs.
The glass beside the surgery takes the same care as the glass in the leaf. A sidelight or a fanlight beside the leaf takes the proof the leaf carries, because the wall beside a proved leaf holds no more than the glass in it.
| Position | Door | Grade | What to check |
|---|---|---|---|
| Reception | Staff leaf | LPS 1175 B3 | Leaf, reader, closer |
| Surgery | Steel leaf | LPS 1175 C5 | Leaf, lock, seals |
| Drugs store | Steel leaf | LPS 1175 D10 | Leaf, lock, seals |
| Records room | Steel leaf | LPS 1175 C5 | Leaf, lock, reader |
| Plant room | Fire leaf | FD60 | Leaf, seals, gap |
Holding fire and forced entry on the same leaf
A dental practice door must hold fire back for its period and hold an intruder out for its rating, with both proofs on the same leaf. The period follows the room behind the leaf, because the surgery, the stores and reception ask different things of the leaf, and the grade follows the value behind it.
The fire proof on a doorset comes from EN 1634-1, written as minutes with letters beside them. The minutes run from 30 to 120, and each letter names what the doorset held back: the flames alone, the flames with some of the heat, or the flames with the heat as well. Number and letters sit together on the order, because the minutes on their own name only half the proof.
The gap round the leaf is kept to 4 mm, so the leaf swings free and the seal meets the frame all round when the leaf shuts. The intumescent seal wakes in heat at around 200 to 250 degrees, and a coat of paint laid over it holds it down, so it cannot swell when the fire comes. The gauge comes out on the round, and a gap that has opened or a seal that has come away from its groove is written down beside the door before the round ends.
The dental practice order: one list, every leaf named
Put the dental practice door order together as one list, with a line for every door in the practice and the leaf, the grade, the lock and the closer beside each one, so the door that arrives matches the door that was ordered. A list that names one leaf for the whole practice leaves the fitter to guess, and a leaf fitted to the wrong room guards the wrong thing.
Every line on the list carries its price before the order goes out. The leaf, the lock, the closer and the seal each sit beside their own figure, so the practice knows what the order costs before a leaf is made. The columns the list needs are set out in the how to specify security doors guide, and what each step up the scale adds to the price is worked through in the security door cost factors guide.
The practice manager tries every door on a set day each month, starting at reception and working through the surgeries to the stores and the plant room. Each leaf is opened and shut, each lock is turned, and each closer is watched as the leaf comes home. The record of the visit stays with the practice file, and a leaf that will not shut or a lock that will not throw is put right before the next patient walks in. The fire door inspection checklist sets out what each visit should cover, and the security door maintenance checklist covers the doors that must hold both fire and forced entry.
A dental practice door holds only as long as the drugs behind it and the patient beside it, so the grade, the period and the lock must all sit on the same list.
What grade should a dental practice door carry?
The grade follows the room behind the leaf: B3, C5 or D10 to LPS 1175, with the drugs store taking a higher category than reception.
Can one leaf hold fire and forced entry?
Yes, where the same leaf, frame and seals were proved for fire and for forced entry together, so one doorset carries the proof for both jobs.
Do dental practice doors need access control?
The doors behind reception take a reader beside the leaf, so the leaf opens for staff and stays shut for the public.
What period should a surgery door carry?
FD30 or FD60 to EN 1634-1, and the letters beside the minutes say whether the doorset held the flames alone or the heat as well. Each door takes the period its room demands.
Who checks the dental practice doors?
The practice manager walks the round that covers every door, and the record of each visit stays with the practice file.
Get a free quote
Related
More in guides for specifiers
Products
One supplier for the whole building envelope
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.