Museums hold a collection and a crowd, so the fire doors must hold the line and let people out: the periods, the routes and the doors a museum order names.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed across the UK
Prefer to talk?+44 7352 267239

Get a free project quote

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

A museum holds a collection that cannot be replaced and a crowd that came to look at it, and the fire doors must guard both. The leaf must hold fire back for its period, and it must open for visitors who have never walked the route before.

Each door in a museum takes its period from the room behind it, because the gallery, the store and the public route ask different things of the leaf. The order names the period beside each opening, so the door that arrives is the door the room needs.

The rules for the shared parts of a public building are set out in the fire door regulations commercial buildings guide, and the doors that guard each part of a building are worked through in the types of security doors guide. The museum order names every door in the building, with the period and the hardware beside each one.

  • FD30 / FD60Fire periods to EN 1634-1
  • E / EW / EI 30-120What the letters beside the period mean
  • 4 mmThe gap round the leaf
  • One listEvery museum door named

Galleries, stores and the routes between them

A museum divides into three parts, and the rules follow the parts. The galleries hold the collection on show, the stores hold the collection out of sight, and the public route carries the visitors between them. A door between one part and the next must hold the line between them, so the fire stays on the side where it started and the people reach the way out.

The gallery takes the doors that let visitors in and out, and each leaf must open for people who have never seen the building before. The store takes the doors that guard what the public never sees, and each leaf must hold fire back where the collection sits. The route between them takes the doors that carry the crowd, and each leaf takes the period the way out needs.

The strategy that names every opening is written before the order goes out, and each door on the list takes the period the opening demands. A leaf ordered without the strategy behind it may land where it does not belong.

FD30 and FD60 in a museum: the periods each room takes

Each room in a museum asks a different period of its doors, because the load behind each leaf is different. The store holds the collection in boxes and crates, the gallery holds it on open display, and the plant room holds the machinery that serves the building, so the period on each door follows the room, not the leaf.

A doorset is proved to EN 1634-1, and the proof is written as a number of minutes with letters beside it. The number runs from 30 to 120, and the letters name what the doorset held back: the flames alone, the flames with some of the heat, or the flames with the heat as well. The number and the letters sit together on the order, because the period on its own names only half the proof.

A longer period means a heavier leaf, a deeper frame and seals that hold longer, and the price follows the period. The door that was proved for 30 minutes cannot stand on an opening that must hold 60. The periods for the shared parts of a public building are set out in the fire door regulations commercial buildings guide.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

The gallery doors: the leaves that guard what hangs on the wall

The gallery doors take the visitors in and out, and each leaf must open for people who have never touched it before. The release on each leaf throws the latch with one push, and the leaf swings open even when the power has gone.

A glazed leaf lets visitors see through before the leaf opens, and the pane beside the leaf takes the same proof as the leaf itself, because a door that holds while the glass beside it fails has held nothing. The glass in the leaf takes the bead and the fixings the test report names. The fire rated windows guide covers the windows that share the same wall, and the fire rated glass cost guide works through the cost of the glass itself.

The gallery leaf must shut quietly after every visitor. The closer on each leaf is set to pull the leaf home without a slam, and the closer is tested by opening the leaf and watching it shut on its own. The fire door closers guide sets out the sizes and the fitting of closers, and the acoustic doors guide covers the leaves that keep a gallery quiet.

Stores and archives: the doors behind the collection

The store holds the collection that is not on show, and the doors that guard it take the longest period on the order. The room behind the leaf holds boxes, crates and frames, and the fire load behind the door is the greatest in the building, so the leaf must hold longer than any other door in the museum.

The store needs a leaf that holds fire back and holds an intruder out, so one leaf can carry both proofs. Fire is proved to EN 1634-1 in E, EW and EI from 30 to 120 minutes, and forced entry is proved to LPS 1175, where B3 holds three minutes, C5 holds five and D10 holds ten. Both proofs cover the same leaf, frame and seals, proved together as one doorset.

The archive takes a door that guards paper and records, and the leaf must hold fire back where the loss would be greatest. The loading bay takes a door wide enough for crates, and the bay door takes a closer that pulls it shut after each load. The doors that guard a warehouse take the same care with their stores, and the fire door regulations warehouses guide sets out the periods for a building that holds stock.

The public route: the way out for a crowd that came to look

The visitors in a museum follow the route the building gives them, and the way out must be clear when the alarm sounds. Each door on the route opens with one push from anyone who reaches it, because the leaf must open whatever the power is doing.

Smoke seals to BS EN 1634-3 sit on the route doors, Sa for smoke at room temperature and S200 for smoke at 200 degrees. The seal closes the gap the leaf leaves, and it must meet the frame all round, because the smoke reaches the route before the flames do. The smoke control doors guide covers the doors that hold smoke back while people move past them.

Every door on one route takes the period the route needs, and no door on the route takes less. A leaf proved to a shorter period than the leaves beside it fails first. The fire door regulations leisure centres guide covers the doors on a public building that fills with visitors.

Position Door Period What to check
Gallery Glazed leaf FD30 Leaf, glass, closer
Store Steel leaf FD60 Leaf, lock, seals
Archive Fire leaf FD60 Leaf, seals, gap
Public route Fire leaf FD60 Leaf, bar, closer
Plant room Fire leaf FD60 Leaf, seals, gap

The leaf that must shut quietly: closers, seals and the gap

The closer on a museum door works through every visitor who passes, and the leaf must shut without a slam. The smallest power a fire door closer may take is EN 3 to BS EN 1154, and the closer is tested by opening the leaf and watching it shut on its own. A closer that no longer pulls the leaf home leaves the door standing open.

Four millimetres round the leaf is the gap the door must keep, so the leaf can swing and the seal can close. The intumescent seal wakes at around 200 to 250 degrees, and paint over the seal stops it swelling. The gap is checked with the gauge on the round, and a seal that has come away from its groove goes into the record beside the door.

Each hinge carries its share of the leaf, and the leaf hangs true only while the hinges hold. A hinge that has worked loose lets the leaf drop a little each month, until the leaf drags and the gap at the top opens wide enough for smoke to pass. The hinges are looked at on every visit, and the lock the key turns is covered in the fire door hardware guide.

Doors that guard the collection: the grade by the room

The forced entry proof on a museum door is LPS 1175, and the category follows the room behind the leaf. Under Issue 8.2, dated September 2024, B3 resists for three minutes, C5 for five and D10 for ten, and the category on the order is set by what sits behind the leaf.

A gallery door takes B3, because the room behind it holds the collection on open display and the intruder would try it first. A store door takes C5, because the room behind it holds what the museum runs on. The strong room that holds the takings and the keys takes D10, because it must hold longest. The LPS 1175 vs PAS 24 guide works through the two ratings side by side, and the keeping an LPS 1175 rating valid guide sets out what breaks a rating once a door is fitted.

The old names SR2, SR3 and SR4 mean the same categories, and the category on the order is the one the product was proved to. A door that guards the collection takes a higher category than a door that guards a corridor, because the rooms behind them hold different things. No published table maps LPS 1175 to any other standard, so the order names LPS 1175 on its own.

The museum door list: every leaf named before the order

Put the museum door order together as one list, with a line for every door in the building and the leaf, the period, the lock and the closer beside each one, so the door that arrives matches the door that was ordered. A list that names one leaf for the whole building leaves the fitter to guess which room takes which rating, and a leaf fitted to the wrong room guards the wrong thing.

The price is read beside the list, line by line, so every leaf, lock, closer and seal is priced before the order goes out. The how to specify security doors guide sets out the columns the list needs.

The doors are checked on a round that goes through the galleries, the stores, the route and the plant room, door by door, and each leaf is opened and shut as the round reaches it. A fault found on the round is noted on the day it is found, with the door, the part and the date beside it. The fire door inspection checklist sets out what a visit should cover.

A museum door holds only as long as the collection behind it and the way out beside it, so the period, the grade and the closer must all sit on the same list.

What period should a museum door carry?

The period follows the room behind the leaf: FD30 or FD60 to EN 1634-1, with E, EW or EI beside the number naming what the doorset held back.

Can one leaf hold fire and forced entry?

Yes, when the leaf, the frame and the seals faced the test together for fire and for forced entry, so the one doorset carries the proof for both.

Do museum doors need panic hardware?

The doors on the way out take a panic bar to BS EN 1125, at least 60 percent of the leaf wide, so the leaf opens for a crowd with one push.

What grade should a store door carry?

The grade follows the room: B3, C5 or D10 to LPS 1175, with the store taking a higher category than the gallery beside it.

Who checks the museum doors?

The person who runs the building walks the round that covers every door, and the record of each visit stays with the building file.

Specifying doors for a museum?Send the door list and the collection each door must guard for a tested door quotation.
Get a free quote

Related

More in guides for specifiers

10 mistakes when specifying certified security doors 10 steps to specify an LPS 1175 door Acceptance and Snagging of a Security Door or Barrier Job Access Control Doors Acoustic Doors: Ratings and Specification After a Forced Entry Attempt: Checking a Security Door Airport Security Doors Anti-Ligature Doors for Mental Health Wards Anti-Ram Bollards Anti-ram gates and barriers: protecting vehicle entrances Arcade Security Doors Explained Automatic Doors Automatic Gates Cost Factors Automatic Vehicle Barriers Ballistic Panels Bank Security Doors Bingo Hall Security Doors Explained Blast doors: glazed vs solid and how they are rated Blast protection window film: what it does and what it cannot do Blast resistant windows: what drives the cost and how to specify them Bollard Cost Factors Explained Bollard regulations in the UK: spacing, height and depth Bookmaker Security Doors Explained Builders Merchant Security Doors Bullet Resistant Glass Cost Factors Bullet resistant glass ratings explained: BR1 to BR7 and SG classes Bullet resistant vs bulletproof glass: what the difference means Buying Security Doors and HVM Through Public Frameworks Car Park Security Doors Explained Car Showroom Security Doors Casino Security Doors Explained CDM 2015 Duties When Security Doors, Shutters or HVM Are Installed Cinema Security Doors Cleanroom Doors Cold Store Doors College Security Doors Commissioning, Handover and the O&M Manual for Security Doors and HVM Communal entrance doors for flats: Secured by Design and what to specify Community Centre Security Doors Control Room Doors Court Security Doors Crash Rated Fences and HVM Fencing Explained Data centre physical security: doors, glazing, HVM and shielding by zone Dental Practice Security Doors Depot Security Doors Explained Door Entry Systems Due Diligence When Selecting Vehicle Security Barriers Emergency Exit Doors EMP Shielding Cost Factors Explained Exhibition Centre Fire Door Rules Exhibition Centre Security Doors Factory Security Doors Faraday cage vs RF shielded room: what a business needs FB4 vs FB6 vs FB7: how to choose a ballistic rating Fire and security doors: how dual certification works Fire Compartmentation Fire Curtains Fire Door Certification Fire Door Closers Explained Fire Door Cost Factors Fire Door Duties of the Accountable Person Fire Door Gaps Fire Door Hardware Explained Fire door inspection checklist for steel and timber doors Fire Door Maintenance Fire Door Regulations Care Homes Fire Door Regulations for A and E Departments Fire Door Regulations for Airports Explained Fire Door Regulations for Bowls Clubs Fire door regulations for commercial buildings in the UK Fire Door Regulations for Dialysis Centres Fire Door Regulations for Hockey Clubs Fire Door Regulations for Hospitals Explained Fire Door Regulations for Offices Explained Fire Door Regulations for Operating Theatres Fire Door Regulations for Retail Explained Fire Door Regulations for Schools Explained Fire Door Regulations for Snooker Clubs Fire Door Regulations for Stadiums Fire Door Regulations for Student Accommodation Fire Door Regulations for Warehouses Fire Door Regulations Leisure Centres Fire Door Regulations Restaurants Fire Door Remediation Programme for Housing Providers Fire Door Rules for Badminton Clubs Fire Door Rules for Bingo Halls Fire Door Rules for Bookmakers Fire Door Rules for Bowling Alleys Fire Door Rules for Car Parks Fire Door Rules for Car Showrooms Fire Door Rules for Cinemas Fire Door Rules for Climbing Centres Fire Door Rules for Colleges Fire Door Rules for Community Centres Fire Door Rules for Cricket Clubs Fire Door Rules for Dental Practices Fire Door Rules for Depots Explained Fire Door Rules for Golf Clubs Fire Door Rules for GP Surgeries Fire Door Rules for Gyms Explained Fire Door Rules for Ice Rinks Fire Door Rules for Maternity Units Fire Door Rules for Mental Health Units Fire Door Rules for Oncology Units Fire Door Rules for Opticians Fire Door Rules for Pawnbrokers Fire Door Rules for Petrol Stations Fire Door Rules for Pharmacies Fire Door Rules for Ports Fire Door Rules for Post Offices Fire Door Rules for Prisons Fire Door Rules for Rehabilitation Centres Fire Door Rules for Self Storage Fire Door Rules for Shopping Centres Fire Door Rules for Squash Clubs Fire Door Rules for Supermarkets Fire Door Rules for Swimming Pools Fire Door Rules for Tennis Clubs Fire Door Rules for Theatres Fire Door Rules for UK Arcades Fire Door Rules for UK Casinos Fire Door Rules for UK Hospices Fire Door Rules for Walk-in Centres Fire Door Signage Fire Door Vision Panels Fire Doors and Gateway 2 in Higher-Risk Buildings Fire Rated Glass Cost Explained Fire Rated Sliding Doors Explained Fire Rated Windows Cost Factors Fire Rated Windows Explained Fire Safety Enforcement Notices and Fire Doors: What the Responsible Person Must Do Flat Entrance Doors: PAS 24 and Fire Rated Forced Entry vs Ballistic vs Blast: Which Rating a Site Needs Garage Security Doors Explained Gate Automation Explained Golden Thread Records for Fire Doors GP Surgery Security Doors Explained Gym Security Doors Explained High Speed Doors HMO Fire Doors Hospice Security Doors Explained Hospital Security Doors: Wards, A&E, Plant Hospital Security Gates Hotel Fire Doors Hotel Security Doors How to choose HVM bollards: fixed, shallow mount, removable and automatic How to keep an LPS 1175 door rating valid after installation How to Specify Fire Doors in a Housing Tender How to specify security doors: a checklist for architects How to Verify a Secured by Design Listing How to Verify an LPS 1175 Certificate on Red Book Live How to Write an Operational Requirement for Physical Security HVM planters and street furniture: protection that blends in In-Service Care of Vehicle Security Barriers Installation Handover: LPS 1175 Doors and PAS 68 Barriers Intumescent Seals ISO 16933 explained: EXV and SB classes and hazard ratings ISO 22343 vehicle security barriers explained Keeping a Dual-Certified Fire and Security Door Valid in Service Laboratory Security Doors Layered Security for a Site: Deter, Detect, Delay, Mitigate, Respond Lead Times and Programme Risks for LPS 1175 Doors Leisure Centre Security Doors Library Security Doors Listed Building Fire Doors Loading Bay Doors Explained Lockdown and Access Control Hardware on an LPS 1175 Door LPS 1175 Gates and Grilles Explained LPS 1175 Issue 8 explained: from SR1 to SR8 to A1 to H20 LPS 1175 Roller Shutters LPS 1175 vs ASTM F2781 and Other US Ratings Explained LPS 1175 vs EN 1627: how UK and European burglar resistance ratings compare LPS 1175 vs PAS 24: which security standard does your door need? LPS 1175 Windows and Walling Explained Martyn’s Law and Places of Worship: What a Buyer Checks for Doors and Entry Control Martyn’s Law Enhanced Tier: Physical Measures and the Specifier Brief Martyn’s Law Standard Tier: Procedures, Doors and Shutters Martyn’s Law Timeline and the SIA Regulator Martyn’s Law: what premises must do and which physical measures to consider Master Key Systems MRI and RF shielded rooms: how they work and what to specify Museum Security Doors NPSA Catalogue of Security Equipment (CSE) Explained NPSA Forced Entry and Blast Guidance for Government Sites NPSA Guidance on Lockdown and Marauding Attack: What It Asks of Doors and Entrances Office Security Doors Optician Security Doors Explained Panic Hardware PAS 24 requirements for doors and windows explained PAS 68 Bollard Foundations Explained PAS 68 bollards: ratings, spacing and cost factors PAS 68 vs IWA 14 vs ISO 22343: hostile vehicle mitigation standards explained Pawnbroker Security Doors Explained Pedestrian Gates Petrol Station Security Doors Pharmacy Security Doors Planning Permission for Security Shutters, Gates and Bollards on Commercial Premises Plant room doors: fire, security and ventilation requirements Plant Room Fire Doors Port Security Doors Post Office Security Doors Explained Powder coating vs galvanising vs paint for steel Preliminary Market Engagement for Security Doors and HVM Prison Security Doors Programming a Security Door and Barrier Package on a Live Site Public-Sector Tender Response Checklist for Security Door and HVM Supply Reading a PAS 24 and SBD Door Test Report Regulation 38 Fire Safety Information at Handover for Fire-Rated Security Doorsets Replacing Security Doors in an Occupied Building Restaurant Security Doors Retail Security Doors Revolving Doors RF shielding standards and how shielded rooms are tested Rising Bollard Cost Factors Road Blocker Cost Factors Explained Road Blockers Explained Roller Shutter Cost Factors: What Drives the Price Roller shutter regulations in the UK: safety and maintenance Safe room and panic room doors: specification basics Safety Duties for Powered Doors, Gates and Barriers on Commercial Sites School Security Doors Sectional Doors Secured by Design explained: is it mandatory for doors? Secured by Design vs NPSA vs LPCB: Which One You Need Security Door Locks Security Door Maintenance Checklist Security Doors and Access for Everyone: What Approved Document M Asks Security Doors for A and E Departments Security Doors for Badminton Clubs Security Doors for Bowling Alleys Security Doors for Bowls Clubs Security Doors for Climbing Centres Security Doors for Cricket Clubs Security Doors for Dialysis Centres Security Doors for Golf Clubs Security Doors for Hockey Clubs Security Doors for Ice Rinks Security Doors for Maternity Units Security Doors for Mental Health Units Security Doors for Oncology Units Security Doors for Operating Theatres Security Doors for Rehabilitation Centres Security Doors for Snooker Clubs Security Doors for Squash Clubs Security Doors for Swimming Pools Security Doors for Tennis Clubs Security Doors for Walk-in Centres Security Doors West Midlands Explained Security Fencing Security Gates Cost Factors Explained Security shutters vs high performance roller doors Security shutters vs retractable grilles: which suits retail and commercial openings? Security Turnstiles Explained Security Window Film Security Windows for Schools Explained Self Storage Security Doors Server Room Doors Explained Shopping Centre Security Doors Smoke Control Doors Explained Smoke Curtains Specification Mistakes When Mixing LPS 1175, PAS 24 and SBD in One Tender SR2 vs SR3 vs SR4 security doors: choosing the right LPS 1175 level Stadium Security Doors Steel Door Frames Steel vs aluminium security doors: strength, ratings and looks Steel vs timber fire doors: which suits your building? Student Accommodation Security Doors Substation doors: security, ventilation and specification Supermarket Security Doors Telescopic Bollards Tender Evaluation Criteria and Scoring for Security Doors and HVM The Scope of a Maintenance Contract for Security Doors and Barriers Theatre Security Doors Thermal and Weather Performance of External Security Doorsets Thermally broken steel security doors: U-values and certification Traffic Calming as Hostile Vehicle Mitigation Transport hub security requirements Turnstile Cost Factors Explained Turnstile vs speed gate vs security portal: choosing entrance control Types of security doors for commercial buildings University Security Doors Explained Vehicle Dynamics Assessment: What It Tells the Buyer Before a Barrier Is Specified Warehouse Security Doors Explained Warehouse Security Gates Warranty, Defects Liability and Guarantees for Security Doors and Barriers What affects the cost of a bullet resistant door What affects the cost of a high-security door in the UK Window Security Bars View all →

Products

One supplier for the whole building envelope

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.