ArxBridge
Security Fencing
Security fencing for boundaries and compounds: palisade, mesh and anti-climb options, gates and bollards, foundations, planning and one schedule.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A fence is the first line a site owns. It stands between the road and the buildings, it keeps people out of the yard after hours, and it marks where the site begins. A fence that leans, gaps or gives way at the gate leaves the boundary open, whatever the doors behind it can hold.
The order starts with the boundary, not with the panel. A yard that holds plant asks for a different fence from a compound that holds fuel, and a boundary that faces a public footpath asks for a different height from one that faces a field. The ground, the risk and the people who pass the line decide the fence before the panel is chosen.
Every run of fence on the site sits on one schedule, and an order that names each one plainly gets the right fence on the right run. The security gates page covers the gates that sit in the line, and the crash rated fences and HVM fencing guide covers the fencing that holds a vehicle.
- ISO 22343-1Vehicle security barrier ratings
- 1,200 mmMaximum clear gap on a vehicle line
- 500 mmMinimum height on a vehicle line
- LPS 1175 B3 / C5 / D10Forced entry ratings, three, five and ten minutes
Palisade, mesh and weld: the fence types a boundary can take
A palisade fence is steel pales fixed to horizontal rails, with gaps between the pales that stop a foothold and let the line be seen through. It suits a boundary where the site must be watched from the road, because the gaps show what moves behind the line, and the pales take a knock without bending out of shape.
A welded mesh fence is panels of steel wire welded into a grid, and it suits a boundary where the line must hold against cutting. The wire gauge and the weld decide how long the cut takes, and a mesh with small apertures leaves no grip for a foot, so the panel resists climbing as well as cutting.
The choice follows the risk the boundary faces, not the panel the catalogue shows first. A yard that must be seen takes palisade or open mesh, and a compound that must be hidden takes a closer mesh. The choosing HVM bollards guide covers the bollards that stand beside the fence line.
Climbing, cutting and lifting: how a fence is attacked
Climbing is the first attack a fence must beat. A rail that runs across the fence at waist height is a step, and a panel with wide apertures is a ladder, so the rails should sit where they cannot be stood on.
Cutting is the second attack, and it comes with hand tools. The wire gauge sets how long the cut takes, the weld sets whether the panel falls apart once it is cut, and a panel cut at the bottom can be lifted aside, so the fixings that hold the panel to the post matter as much as the panel itself.
Lifting and digging are the attacks the ground decides. A panel lifted off its posts leaves a gap a person can walk through, and ground dug under the line leaves a gap a person can crawl through, so the fixings must hold the panel down and the footing must run below the ground. The LPS 1175 gates and grilles guide covers the rated grilles that guard an opening in the line.
The ground under the fence: foundations, posts and the line that stays put
A fence stands on its posts, and the posts stand on concrete. The depth and the spacing of the posts decide whether the line stays upright in a storm, and the concrete must be poured round a post set straight, because a post that leans on the day it is fitted will only lean further.
Slopes and soft ground change the order. Panels must be stepped down a slope, so no gap opens under the fence where the ground falls away, and soft ground needs deeper posts and wider footings, because a post in soft ground pulls out the first time the wind pushes the line.
Water is the quiet enemy of a fence line. Posts that stand in water rot at the base, and fixings that sit in the wet rust where no one can see them, so the drainage round the line belongs on the order beside the panels, and the ground should fall away from the posts, not towards them. The PAS 68 bollard foundations guide covers the foundations that hold a rated bollard in the ground.
Gates and bollards beside the fence: closing the gaps in the line
The gate is the hole in the fence, and it must hold the same proof as the fence beside it. A pedestrian gate that takes a reader and a lock, and a vehicle gate that takes a motor and a release on alarm, each belong on the same schedule line as the fence, because a gate that holds less than the fence is the way in.
Bollards stand where the fence ends and the road begins, and they close the gap a vehicle could drive through. The bollards must be fixed to foundations that hold them, and the spacing must leave no gap a vehicle can pass. The anti-ram gates and barriers guide covers the rated options for the gate line, and the security bollards page covers the bollards that stand in it.
The line must close where the fence meets the building. A gap between the last panel and the wall is a way in, so the panel should be fixed to the wall with the same fixings as the posts, and the joint should be checked on the round, because a joint that has worked loose leaves the line open at the very place it meets the building.
The vehicle line at the boundary: rated barriers where a fence is not enough
A fence holds a person, not a vehicle, and where a vehicle could reach the building the line needs a rated barrier. Vehicle ratings are proved to ISO 22343-1, which supersedes PAS 68:2013, with test vehicles from a 1,500 kg car to a 30,000 kg truck at 48, 64 or 80 km/h, and the rating on the order should match the vehicle the approach could bring.
ProtectUK sets the spacing on the line, with no more than 1,200 mm clear between bollards and a minimum height of 500 mm. The ISO 22343 vehicle security barriers guide sets out the ratings in full, and the hostile vehicle mitigation page covers the line in full.
Fence and barrier work together at the gate. The barrier stands in front of the fence where vehicles pass, and the fence stands behind it where people pass, so the two meet at the gate post and the joint between them holds. The rising bollards page covers the bollards that rise from the ground at the gate.
Height, planning and the neighbours: the rules before the order
Height is set by the planning rules before the order is placed. A fence beside a public road or in a conservation area may carry a lower height than a fence round a yard, and a fence that needs approval must wait for it, because a fence put up without approval may have to come down again.
The neighbours share the line, and the fence that faces them should be kept tidy and the sightlines open. A fence that blocks the view of a junction leaves drivers blind, so the height at the corner belongs on the plan beside the height along the run.
The approval belongs on the file beside the rating, and the order should wait for it. A fence ordered before the approval arrives may arrive at the wrong height, and a height changed after the panels are made costs the panels twice over. The gate automation guide covers the drives and the safety devices on the gate in the line.
Keeping the line standing: the round that finds the weak post
Walk the whole boundary once a month and look at every post, panel and gate in turn. A post that leans, a panel that has come loose from its fixings or a gate that drags on its hinges each gets written down the same day, with the run and the fault beside it, so the repair follows the fault and the line never stands open.
Rust and rot are the parts that fail first, and they fail where no one looks. The base of each post, the fixings under each panel and the hinges on each gate should be checked first on every round, because a post that rots at the base falls in the first storm, and a fixing that rusts through leaves the panel hanging on one bolt.
Storm damage needs a repair the same day. A panel down after a storm leaves the line open, so the spare panels and the fixings should be kept on site, and the round after a storm should walk the whole boundary before anything else. The security door maintenance checklist covers the doors that sit in the line.
One schedule for the whole boundary: every run on one line
Put every run on one list before the order goes out, with the panel type, the height, the posts and the gates written beside each run, so the fence that turns up is the fence that was tested. A schedule that names one fence for the whole site leaves the fitter to guess which panel goes where, and a guess is not a proof.
Read two quotes side by side and check that each one names the same panels, the same posts and the same gates. A quote that leaves the foundations off the list has not saved money, it has only moved the cost to the day the fence is fitted, and digging foundations round a fence that is already up costs more than pouring them with the posts. The security door cost factors guide sets out what each step up the scale adds to the build, and the how to specify security doors guide sets out the columns the schedule needs.
Keep the test report for every gate in the line in the file with the fence, and write the inspection routine into the handover pack. The file should hold the rating for the gate, the fixings for the panels and the foundations for the posts. The keeping an LPS 1175 rating valid guide sets out what breaks a rating.
| Run | Fence | Rating | What to check |
|---|---|---|---|
| Front boundary | Welded mesh | LPS 1175 B3 | Panels, fixings, posts |
| Yard | Palisade | LPS 1175 C5 | Pales, rails, gates |
| Gate line | Vehicle gate | ISO 22343-1 | Rating, release, motor |
| Compound | Anti-climb mesh | LPS 1175 B3 | Apertures, fixings, footing |
| Vehicle approach | Rated barrier | ISO 22343-1 | Foundations, spacing |
A fence is only as strong as its weakest run, so the panel, the post and the gate must all sit on the same schedule.
What fence suits a boundary that must be seen through?
Welded mesh or palisade. The panel follows the risk the boundary faces and the ground it stands on, and the posts must be fixed in ground that can hold them.
How is a fence rated against forced entry?
To LPS 1175, with B3, C5 and D10 naming three, five and ten minutes. The rating names the panel, the posts and the fixings together, because a panel proved without its fixings has no proof at all.
Can a fence stop a vehicle?
No, a fence holds a person. Where a vehicle could reach the building, the line needs a rated barrier proved to ISO 22343-1, with the spacing ProtectUK sets.
What height can a security fence be?
The height follows the planning approval and the site. The approval belongs on the file before the order is placed, and the order should wait for it.
Who checks security fencing?
The person who runs the site, on the routine the site keeps. Each round walks every post, panel and gate, and every fault found is written down the same day.
Get a free quote
Related
More in guides for specifiers
Products
One supplier for the whole building envelope
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.