Certified physical security

ArxBridge
Steel door sample in a security test frame with an assessor in a UK test laboratory

ArxBridge

Security Doors for Swimming Pools

A pool takes cash at the desk and crowds through the day, so each leaf takes the LPS 1175 grade its room demands, B3 at the entrance and D10 at the cash desk.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed across the UK
Prefer to talk?+44 7352 267239

Get a free project quote

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

A swimming pool takes cash at the desk through the day, crowds through the pool hall at lesson times, and bags and phones left in the changing rooms while their owners swim. The entrance takes arrivals in, the cash desk takes their money, the pool hall holds the water and the swimmers, the changing rooms hold the bags, the plant room keeps the water moving, the chemical store holds the dosing chemicals, and the staff office holds the records.

Under LPS 1175 Issue 8.2, dated September 2024, a leaf earns its grade from the minutes it stands against the tools the test names. A B3 leaf stands for three minutes, a C5 leaf for five minutes and a D10 leaf for ten minutes, and older drawings may still name the same three leaves SR2, SR3 and SR4, so the order carries both names beside each leaf.

A swimming pool is not a leisure centre, because the building holds water and swimmers rather than sports halls and courts, and it is not a gym, because the hall holds a pool rather than studios and machines, and it is not a spa, because the pool is public rather than a set of treatment rooms. The leisure centre security doors guide grades the doors of a building that holds sports halls beside its pool, and the security doors for gyms guide grades the doors round studios and machines.

  • B3 / C5 / D10Grades to LPS 1175 Issue 8.2
  • Cash deskWhere D10 sits in the pool
  • Wet floorsSwimmers move slowly when wet
  • One listEvery pool leaf named

Seven rooms in a swimming pool: the grade each leaf takes

Seven rooms make up a swimming pool, and the grade follows what each room holds. The seven rooms are the entrance, the cash desk, the pool hall, the changing rooms, the plant room, the chemical store and the staff office.

B3 sits on the entrance, the pool hall and the changing rooms, because all three stand where swimmers and staff can see them. C5 goes on the plant room, the chemical store and the staff office, because the plant, the chemicals and the records behind those leaves ask for a longer hold than the public rooms. The cash desk takes D10, because the till and the safe behind it hold the most portable value in the building.

Each opening gets its own line on the order, with the leaf, the grade and the minutes beside it, so the fitter can match each leaf to its line before it goes up.

Room Grade Minutes What to check
Entrance B3 3 Leaf, lock, closer
Cash desk D10 10 Leaf, lock, safe
Pool hall B3 3 Leaf, lock, closer
Changing rooms B3 3 Leaf, lock, closer
Plant room C5 5 Leaf, lock, seals
Chemical store C5 5 Leaf, lock, seals
Staff office C5 5 Leaf, lock, reader

One leaf in the pool can carry the fire proof and the forced entry proof together, so a single report holds both. EN 1634-1 counts the fire minutes from 30 to 120, and the letter after the number says what stayed back: E for flame alone, EW for flame with part of the heat, EI for flame with the heat too. The fire and security doors dual certification guide covers a leaf proved for both, and the SR2 vs SR3 vs SR4 guide sets the old names beside the new grades.

The entrance and pool hall: B3 where swimmers arrive

Swimmers arrive at the entrance in waves, at lesson times and at the start of public sessions, so the leaf between the street and the cash desk stays shut and locked between each arrival. Staff open it with a card or a key.

The entrance takes three minutes because it stands in view of the cash desk staff. A reader on the street side opens the leaf to staff cards, with a key override behind it for the day the reader fails. The access control doors guide covers readers and locks on a pool leaf, and the door entry systems guide covers the panel that lets staff through from the street.

A swimmer pushing the entrance leaf meets a limit set by BS 8300 and Approved Document M, under 30 N across the first 30 degrees of swing and under 22.5 N after that, so the leaf opens for a person with wet feet and a bag over one shoulder. The closer that pulls the leaf shut carries a proof to BS EN 1154, and EN 1 is the smallest power size the standard names.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

The cash desk: D10 behind the till and the safe

The cash desk holds the till, the float and the safe, so its leaf takes D10, the longest hold LPS 1175 Issue 8.2 names. The test took the leaf, frame, fixings and lock as one doorset, and the report gives ten minutes against the tools the test names, because the cash inside is the easiest value in the building to carry out. No published table sets LPS 1175 grades beside ASTM ratings, so the order carries the LPS grade alone, with no other rating beside it.

The cash desk leaf carries no glass, because a pane would let the queue see the till and would put a hand close to the lock.

Under TS 007, a 1 star cylinder beside a 2 star handle counts as a 3 star set, so the two are ordered as one set and never bought apart. The security door locks guide names what the lock on the cash desk must do, and the keys to the room are held by named staff only. The safe room door specification guide covers the leaf round a room that holds a safe.

Changing rooms: B3 where bags and phones sit

Changing rooms hold bags, phones and wallets while their owners swim, so the leaf takes B3 and stays shut while the rooms are in use. The lock on the room side lets staff open it at once when the rooms need clearing.

Hinges proved to BS EN 1935 carry the leaf: grade 13 through 200,000 cycles under a leaf of 120 kg, grade 14 through the same cycles under a leaf of 160 kg, so the leaf stays square in its frame and the bolt keeps meeting its keep.

Wet feet and damp air work on the hinges and the lock, so the leaf on the changing rooms is checked for drag and rust on the monthly walk. A panel set high in the leaf lets staff see whether the rooms are in use without opening it, and the panel goes through the test with the leaf, so the report names the glass and its fixings beside the leaf. The security doors for bowling alleys guide grades the doors of another building where visitors leave bags behind while they play.

Plant room, chemical store and staff office: C5 behind the back rooms

The staff office holds the membership records and the papers that run the pool, so C5 sits on its leaf and the leaf stays locked when the room is empty, because an open office would hand a passer by the records and the keys behind it.

The plant room holds the boards and the equipment that keep the water moving and the air fresh, so its leaf takes C5 as well. The plant room door requirements guide names in full what a leaf on that room must do. The chemical store holds the dosing chemicals beside the plant, and its leaf takes C5 because the chemicals behind it must stay out of reach of swimmers and children.

Staff pass between the office and the cash desk all day, so the leaf between the two rooms must shut by itself after every pass. Its closer carries a proof to BS EN 1154, and no fire leaf takes a power size below EN 3.

Cards, keys and readers: who opens which pool leaf

Each leaf behind the cash desk opens to the cards and keys of the staff who work there, and a public card opens none of them. The master key systems guide sets out a key plan that gives each holder the rooms their work needs, and no room beyond those.

The duty manager holds a key that opens every leaf behind the cash desk, and lifeguards hold keys for the rooms their shifts take them to. How the order runs from the first leaf to the last is set out in the 10 steps to specify an LPS 1175 door guide. A lost card is taken off the reader list the day it is reported, so a card found on the changing room floor opens nothing.

Panic bars and the pool hall at closing time

The pool hall can still hold a full hall of swimmers at once, so the leaves on the way out must let them move fast. Where the route serves more than 60 people, a push bar proved to BS EN 1125 runs across the leaves on the way out, and the bar covers no less than 60 percent of the leaf width, so one push from a person in a crowd throws the leaf open. The panic hardware guide names what the bar must do when a crowd pushes against the leaf.

Martyn’s Law gained Royal Assent in April 2025 and the start is expected in spring 2027, with the lower tier covering premises that may hold 200 to 799 people and the higher tier covering 800 or more. A pool whose hall may hold that many people falls inside those tiers. What each tier asks of the building is named in the Martyn’s Law guide for premises.

Bollards keep a vehicle off the frontage, and ProtectUK sets the clear gap between them at 1,200 mm at most, with each bollard standing at least 500 mm high. The choosing HVM bollards guide covers how the frontage is laid out.

The swimming pool order: every leaf, its grade and its lock

One list holds the whole order, with a line for every opening that names the leaf, the grade, the lock and the closer beside it. A leaf with no line of its own may end up hung where it does not belong, and a C5 leaf on the cash desk would hold for five minutes where the cash asks for ten.

The duty manager takes the door list round the pool each month and tries each leaf in turn. A leaf that drags, a bolt that misses its keep or a reader that stays silent goes beside its own door on the list the day it is found, and the security door maintenance checklist names what the walk should cover.

Each leaf on the order is read before the order is signed, because a closer that turns up after the doorset holds the whole job up. What the order must hold for every door is set out in the how to specify security doors guide, and the steel door frames guide names how the frame holds the leaf and the lock together.

The grade on a swimming pool leaf follows the room behind it, so the leaf, the lock and the reader are ordered together and checked together against the cash behind the leaf.

What grade does a swimming pool entrance take?

B3 to LPS 1175 Issue 8.2, which holds for three minutes, because the entrance stands in view of the staff at the cash desk through the day.

What grade does a cash desk take?

D10 to LPS 1175 Issue 8.2, which holds for ten minutes, because the till and the safe sit behind a leaf shut and locked whenever no one works behind the desk.

What grade does a changing room leaf take?

B3 to LPS 1175 Issue 8.2, which holds for three minutes, because the rooms hold bags and phones behind a shut leaf while their owners swim.

Can one leaf hold fire and forced entry?

Yes, where the same leaf was put through the fire test and the forced entry test, so one report carries the period and the grade together.

Who checks the swimming pool doors?

The duty manager walks the pool with the door list each month and tries the leaves in turn, so a fault is found and put right.

Specifying security doors for a swimming pool?Send the door list with the grade and the lock each room must hold for a tested door quotation.
Get a free quote

Related

More in guides for specifiers

10 mistakes when specifying certified security doors 10 steps to specify an LPS 1175 door Acceptance and Snagging of a Security Door or Barrier Job Access Control Doors Acoustic Doors: Ratings and Specification After a Forced Entry Attempt: Checking a Security Door Airport Security Doors Anti-Ligature Doors for Mental Health Wards Anti-Ram Bollards Anti-ram gates and barriers: protecting vehicle entrances Arcade Security Doors Explained Automatic Doors Automatic Gates Cost Factors Automatic Vehicle Barriers Ballistic Panels Bank Security Doors Bingo Hall Security Doors Explained Blast doors: glazed vs solid and how they are rated Blast protection window film: what it does and what it cannot do Blast resistant windows: what drives the cost and how to specify them Bollard Cost Factors Explained Bollard regulations in the UK: spacing, height and depth Bookmaker Security Doors Explained Builders Merchant Security Doors Bullet Resistant Glass Cost Factors Bullet resistant glass ratings explained: BR1 to BR7 and SG classes Bullet resistant vs bulletproof glass: what the difference means Buying Security Doors and HVM Through Public Frameworks Car Park Security Doors Explained Car Showroom Security Doors Casino Security Doors Explained CDM 2015 Duties When Security Doors, Shutters or HVM Are Installed Cinema Security Doors Cleanroom Doors Cold Store Doors College Security Doors Commissioning, Handover and the O&M Manual for Security Doors and HVM Communal entrance doors for flats: Secured by Design and what to specify Community Centre Security Doors Control Room Doors Court Security Doors Crash Rated Fences and HVM Fencing Explained Data centre physical security: doors, glazing, HVM and shielding by zone Dental Practice Security Doors Depot Security Doors Explained Door Entry Systems Due Diligence When Selecting Vehicle Security Barriers Emergency Exit Doors EMP Shielding Cost Factors Explained Exhibition Centre Fire Door Rules Exhibition Centre Security Doors Factory Security Doors Faraday cage vs RF shielded room: what a business needs FB4 vs FB6 vs FB7: how to choose a ballistic rating Fire and security doors: how dual certification works Fire Compartmentation Fire Curtains Fire Door Certification Fire Door Closers Explained Fire Door Cost Factors Fire Door Duties of the Accountable Person Fire Door Gaps Fire Door Hardware Explained Fire door inspection checklist for steel and timber doors Fire Door Maintenance Fire Door Regulations Care Homes Fire Door Regulations for A and E Departments Fire Door Regulations for Airports Explained Fire Door Regulations for Bowls Clubs Fire door regulations for commercial buildings in the UK Fire Door Regulations for Dialysis Centres Fire Door Regulations for Hockey Clubs Fire Door Regulations for Hospitals Explained Fire Door Regulations for Offices Explained Fire Door Regulations for Operating Theatres Fire Door Regulations for Retail Explained Fire Door Regulations for Schools Explained Fire Door Regulations for Snooker Clubs Fire Door Regulations for Stadiums Fire Door Regulations for Student Accommodation Fire Door Regulations for Warehouses Fire Door Regulations Leisure Centres Fire Door Regulations Restaurants Fire Door Remediation Programme for Housing Providers Fire Door Rules for Badminton Clubs Fire Door Rules for Bingo Halls Fire Door Rules for Bookmakers Fire Door Rules for Bowling Alleys Fire Door Rules for Car Parks Fire Door Rules for Car Showrooms Fire Door Rules for Cinemas Fire Door Rules for Climbing Centres Fire Door Rules for Colleges Fire Door Rules for Community Centres Fire Door Rules for Cricket Clubs Fire Door Rules for Dental Practices Fire Door Rules for Depots Explained Fire Door Rules for Golf Clubs Fire Door Rules for GP Surgeries Fire Door Rules for Gyms Explained Fire Door Rules for Ice Rinks Fire Door Rules for Maternity Units Fire Door Rules for Mental Health Units Fire Door Rules for Museums Fire Door Rules for Oncology Units Fire Door Rules for Opticians Fire Door Rules for Pawnbrokers Fire Door Rules for Petrol Stations Fire Door Rules for Pharmacies Fire Door Rules for Ports Fire Door Rules for Post Offices Fire Door Rules for Prisons Fire Door Rules for Rehabilitation Centres Fire Door Rules for Self Storage Fire Door Rules for Shopping Centres Fire Door Rules for Squash Clubs Fire Door Rules for Supermarkets Fire Door Rules for Swimming Pools Fire Door Rules for Tennis Clubs Fire Door Rules for Theatres Fire Door Rules for UK Arcades Fire Door Rules for UK Casinos Fire Door Rules for UK Hospices Fire Door Rules for Walk-in Centres Fire Door Signage Fire Door Vision Panels Fire Doors and Gateway 2 in Higher-Risk Buildings Fire Rated Glass Cost Explained Fire Rated Sliding Doors Explained Fire Rated Windows Cost Factors Fire Rated Windows Explained Fire Safety Enforcement Notices and Fire Doors: What the Responsible Person Must Do Flat Entrance Doors: PAS 24 and Fire Rated Forced Entry vs Ballistic vs Blast: Which Rating a Site Needs Garage Security Doors Explained Gate Automation Explained Golden Thread Records for Fire Doors GP Surgery Security Doors Explained Gym Security Doors Explained High Speed Doors HMO Fire Doors Hospice Security Doors Explained Hospital Security Doors: Wards, A&E, Plant Hospital Security Gates Hotel Fire Doors Hotel Security Doors How to choose HVM bollards: fixed, shallow mount, removable and automatic How to keep an LPS 1175 door rating valid after installation How to Specify Fire Doors in a Housing Tender How to specify security doors: a checklist for architects How to Verify a Secured by Design Listing How to Verify an LPS 1175 Certificate on Red Book Live How to Write an Operational Requirement for Physical Security HVM planters and street furniture: protection that blends in In-Service Care of Vehicle Security Barriers Installation Handover: LPS 1175 Doors and PAS 68 Barriers Intumescent Seals ISO 16933 explained: EXV and SB classes and hazard ratings ISO 22343 vehicle security barriers explained Keeping a Dual-Certified Fire and Security Door Valid in Service Laboratory Security Doors Layered Security for a Site: Deter, Detect, Delay, Mitigate, Respond Lead Times and Programme Risks for LPS 1175 Doors Leisure Centre Security Doors Library Security Doors Listed Building Fire Doors Loading Bay Doors Explained Lockdown and Access Control Hardware on an LPS 1175 Door LPS 1175 Gates and Grilles Explained LPS 1175 Issue 8 explained: from SR1 to SR8 to A1 to H20 LPS 1175 Roller Shutters LPS 1175 vs ASTM F2781 and Other US Ratings Explained LPS 1175 vs EN 1627: how UK and European burglar resistance ratings compare LPS 1175 vs PAS 24: which security standard does your door need? LPS 1175 Windows and Walling Explained Martyn’s Law and Places of Worship: What a Buyer Checks for Doors and Entry Control Martyn’s Law Enhanced Tier: Physical Measures and the Specifier Brief Martyn’s Law Standard Tier: Procedures, Doors and Shutters Martyn’s Law Timeline and the SIA Regulator Martyn’s Law: what premises must do and which physical measures to consider Master Key Systems MRI and RF shielded rooms: how they work and what to specify Museum Security Doors NPSA Catalogue of Security Equipment (CSE) Explained NPSA Forced Entry and Blast Guidance for Government Sites NPSA Guidance on Lockdown and Marauding Attack: What It Asks of Doors and Entrances Office Security Doors Optician Security Doors Explained Panic Hardware PAS 24 requirements for doors and windows explained PAS 68 Bollard Foundations Explained PAS 68 bollards: ratings, spacing and cost factors PAS 68 vs IWA 14 vs ISO 22343: hostile vehicle mitigation standards explained Pawnbroker Security Doors Explained Pedestrian Gates Petrol Station Security Doors Pharmacy Security Doors Planning Permission for Security Shutters, Gates and Bollards on Commercial Premises Plant room doors: fire, security and ventilation requirements Plant Room Fire Doors Port Security Doors Post Office Security Doors Explained Powder coating vs galvanising vs paint for steel Preliminary Market Engagement for Security Doors and HVM Prison Security Doors Programming a Security Door and Barrier Package on a Live Site Public-Sector Tender Response Checklist for Security Door and HVM Supply Reading a PAS 24 and SBD Door Test Report Regulation 38 Fire Safety Information at Handover for Fire-Rated Security Doorsets Replacing Security Doors in an Occupied Building Restaurant Security Doors Retail Security Doors Revolving Doors RF shielding standards and how shielded rooms are tested Rising Bollard Cost Factors Road Blocker Cost Factors Explained Road Blockers Explained Roller Shutter Cost Factors: What Drives the Price Roller shutter regulations in the UK: safety and maintenance Safe room and panic room doors: specification basics Safety Duties for Powered Doors, Gates and Barriers on Commercial Sites School Security Doors Sectional Doors Secured by Design explained: is it mandatory for doors? Secured by Design vs NPSA vs LPCB: Which One You Need Security Door Locks Security Door Maintenance Checklist Security Doors and Access for Everyone: What Approved Document M Asks Security Doors for A and E Departments Security Doors for Badminton Clubs Security Doors for Bowling Alleys Security Doors for Bowls Clubs Security Doors for Climbing Centres Security Doors for Cricket Clubs Security Doors for Dialysis Centres Security Doors for Golf Clubs Security Doors for Hockey Clubs Security Doors for Ice Rinks Security Doors for Maternity Units Security Doors for Mental Health Units Security Doors for Oncology Units Security Doors for Operating Theatres Security Doors for Rehabilitation Centres Security Doors for Snooker Clubs Security Doors for Squash Clubs Security Doors for Tennis Clubs Security Doors for Walk-in Centres Security Doors West Midlands Explained Security Fencing Security Gates Cost Factors Explained Security shutters vs high performance roller doors Security shutters vs retractable grilles: which suits retail and commercial openings? Security Turnstiles Explained Security Window Film Security Windows for Schools Explained Self Storage Security Doors Server Room Doors Explained Shopping Centre Security Doors Smoke Control Doors Explained Smoke Curtains Specification Mistakes When Mixing LPS 1175, PAS 24 and SBD in One Tender SR2 vs SR3 vs SR4 security doors: choosing the right LPS 1175 level Stadium Security Doors Steel Door Frames Steel vs aluminium security doors: strength, ratings and looks Steel vs timber fire doors: which suits your building? Student Accommodation Security Doors Substation doors: security, ventilation and specification Supermarket Security Doors Telescopic Bollards Tender Evaluation Criteria and Scoring for Security Doors and HVM The Scope of a Maintenance Contract for Security Doors and Barriers Theatre Security Doors Thermal and Weather Performance of External Security Doorsets Thermally broken steel security doors: U-values and certification Traffic Calming as Hostile Vehicle Mitigation Transport hub security requirements Turnstile Cost Factors Explained Turnstile vs speed gate vs security portal: choosing entrance control Types of security doors for commercial buildings University Security Doors Explained Vehicle Dynamics Assessment: What It Tells the Buyer Before a Barrier Is Specified Warehouse Security Doors Explained Warehouse Security Gates Warranty, Defects Liability and Guarantees for Security Doors and Barriers What affects the cost of a bullet resistant door What affects the cost of a high-security door in the UK Window Security Bars View all →

Products

One supplier for the whole building envelope

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.