Certified physical security

ArxBridge
Steel door sample in a security test frame with an assessor in a UK test laboratory

ArxBridge

Prison Security Doors

Prison security doors: rated doors for cells, corridors and control rooms, with locks and hinges that resist attack from the inside, on one schedule.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed across the UK
Prefer to talk?+44 7352 267239

Get a free project quote

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

A prison door holds against attack from the side most doors never face. A cell door is attacked from the inside, by a person with time and tools made from what the cell holds, and leaf, frame, hinges and lock all have to hold together for as long as the rating says.

The order comes from the site, not from one door. A cell door takes the highest rating in the building, a corridor door takes the rating that keeps the wings apart, a control room door guards the room that runs the prison, and a perimeter gate takes the vehicle rating, and each one needs a rating, a control and hardware to fit it.

The rating, the access control, the hardware and the records all sit inside one schedule, and a plain order gets the right doors on the right openings. Our anti-ligature doors guide covers the doors that remove ligature points, and the government and defence sector page covers the buildings the doors protect.

  • LPS 1175 D10Ten minutes against category D tools
  • LPS 1175 B3 / C5Three and five minutes, lower rated doors
  • TS 0071-star cylinder with 2-star handle gives 3 stars
  • BS EN 1935Hinge grades 13 and 14

Cells, corridors and control rooms: where a prison puts its security doors

A prison divides into parts that face attack in different ways, and each part puts its doors in a different place. The cell holds one person behind one door, the corridor moves staff and prisoners between wings, the control room runs the gates and the alarms, and the perimeter meets vehicles at the gate.

Every one of those parts has doors that must hold against attack and doors that must open for staff in an emergency, and the two duties sit on the same schedule. A cell door that holds against a prisoner but cannot be opened by staff when a fire starts has failed its other duty, and a corridor door that opens freely but lets a prisoner into another wing has failed its first.

Walk the site, note every door a prisoner or a vehicle can reach, then set each one by the attack it faces. A staffed control room door faces less risk than a cell door that one person attacks for hours, so the rating follows the door, not the prison.

The cell door: the leaf that must hold from the inside

A cell door is attacked from the inside, and that changes everything about it. The leaf is steel, the frame is set into the wall so no edge can be prised, the hinges sit where no hand can reach them, and the lock works from the corridor side.

The vision panel in a cell door lets staff see in without opening it, and the panel must carry the same rating as the leaf around it. A pane that holds against a thrown object but not against a tool leaves a hole in the rating, so glass, frame, beads and fixings go through the test together.

A cell door opened by staff a hundred times a day still has to shut by itself every time. A closer or a motor that pulls the leaf shut belongs on the schedule beside the door, and the inspection round should look for the door that no longer shuts on its own.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Reading the rating on a prison order: B3, C5 and D10

LPS 1175 rates a doorset by the tools it stood against and the minutes it stood. Light hand tools for three minutes earn B3, heavier hand tools for five minutes earn C5, and heavy tools for ten minutes earn D10. Those are the labels in Issue 8.2, dated September 2024, and drawings from before the change still carry the earlier labels, SR2 for B3, SR3 for C5 and SR4 for D10.

The rating follows the door, not the building. A cell door takes D10, because the person behind it has time and tools, a corridor door takes C5, because it separates wings and must hold while staff respond, and a staff room door takes B3. The forced entry ratings are set out in full on our LPS 1175 page, and the two routes are compared in our LPS 1175 versus PAS 24 guide. The LPS 1175 Issue 8.2 (September 2024) explained guide sets out the current issue.

Category D tools are the heavy tools, sledgehammers, disc cutters and jigsaws, and ten minutes against them is the highest rating a prison door carries. A doorset that earns D10 has proved leaf, frame, hinges and lock together, and a door with only the leaf proved has proved only part of the job.

Hinges, locks and vision panels: the parts a cell door depends on

The small parts of a cell door wear first under heat, dust and constant use, and the hinge grade sets how long the door keeps working. BS EN 1935 proves a hinge for cycles and load, grade 13 for 200,000 cycles at 120 kg and grade 14 for the same cycles at 160 kg. Hang a heavy leaf on a hinge that cannot carry it and the leaf sinks, drags on the floor and stops latching. Our fire door hardware guide covers the grades.

The lock on a cell door must resist attack from the corridor side and still let staff open it fast. A cylinder that meets TS 007, a 1-star cylinder with a 2-star handle or escutcheon giving a 3-star set, resists attack from the outside, and a key that turns in one action opens the door without a second hand.

The vision panel is the part a cell door is judged by, because staff look through it all day. The panel must resist the same attack as the leaf, so glass, frame and fixings are proved together, and a panel that fogs, cracks or loosens goes on the record the day it is found.

The cell door that must hold from the inside: locks, keys and control

A cell door must hold from the inside, and it is the leaf a prison depends on most. The hinges, the locks and the vision panels are the parts that decide whether the door works, and each of them must be proved for the job.

Hinges carry the cell door through the same daily cycle as any door, and they must match the weight they carry. Hinges proved to BS EN 1935 carry the leaf through 200,000 cycles, with grade 13 rated for 120 kg and grade 14 for 160 kg, so the hinge follows the weight of the leaf it must carry.

Locks on a cell door must resist the tools a prisoner can reach, so the cylinder and the handle belong on the same line as the leaf. A TS 007 3-star set, made of a 1-star cylinder with a 2-star handle or escutcheon, keeps the lock proved, and the keyway should be restricted, so blanks are held by the supplier and cut only on the order of the person who runs the prison. A key that can be copied anywhere is a key that cannot be controlled.

Vision panels let staff see into the cell without opening the door, and the glass must be proved for the job. A pane that was never tested is a hole in the door, whatever the leaf around it can hold, so the glass, the beads and the fixings belong on the same line as the leaf. The panel must be small enough to keep the leaf proved, because a large pane in a small leaf leaves too little metal to hold.

Corridors, control rooms and the doors that keep a prison moving

The rating on a prison order follows the room the door guards. Forced entry is proved to LPS 1175, with B3 holding three minutes, C5 holding five minutes and D10 holding ten minutes, each against the tool set for its category, all under Issue 8.2, dated September 2024. The cell door takes the highest grade on the order, because the risk at the cell is greater than the risk in a corridor.

Corridors and control rooms take the doors that keep a prison moving, and each of them must open for staff and shut behind them without anyone touching it. Access control in a prison must open for the staff who need the door and stay shut for the rest, so the reader, the intercom and the fail safe state belong on the order beside the leaf. A door that needs power to open is no door at all in a blackout, so the fail position must be written on the order.

One doorset can carry two duties at once, fire and forced entry, and each proof needs its own test on the same doorset. Fire is proved to EN 1634-1 and forced entry to LPS 1175, and one report proves only one of them, so both proofs must be named on the order.

Part What fails What to check When
Hinge Leaf drags Fixings, sag, wear Every round
Lock Door forced Cylinder, keyway, keep Every round
Vision panel Glass broken Glass, beads, fixings Every round
Closer Leaf left open Power, arm, fixings Every round

Name the hinge, the lock and the vision panel beside each cell door on the order, so the door that arrives is the door that was tested. The grades and the parts behind a working fire door are covered in our fire door hardware guide, and the columns a schedule needs are set out in our how to specify security doors guide. The two proofs on one leaf are worked through in our dual certification guide, and the periods for the shared parts of a public building are set out in our commercial buildings fire door regulations guide.

Corridors and control rooms: the doors that keep a prison moving

Corridor doors divide a prison into wings, and each wing door must hold long enough for staff to reach it. A corridor door takes C5 and a closer that pulls a heavy leaf shut against the ventilation draught. A closer that cannot do it leaves the door standing open, and an open door is a gap in the wing, on the route staff use.

The control room runs the gates, the alarms and the cameras, so its door takes the highest rating on the site beside the cell doors. It takes D10 and a lock that resists attack from the corridor, and the room behind it must stay staffed even when the rest of the prison is locked down. The perimeter gate takes the vehicle rating, and our security gates page covers the gate lines, while our gate automation guide covers how a gate is driven.

Closer power sizes come from BS EN 1154, from EN 1 for a 750 mm leaf at 20 kg up to EN 7 for a 1,600 mm leaf at 160 kg, and no fire door takes less than EN 3. A closer set too weak leaves the door standing open, and a closer set too strong breaks the access rules: BS 8300 and Approved Document M cap the opening force at below 30 N through the first 30 degrees and below 22.5 N beyond that.

Access control in a prison: who opens which door, and when

Access control in a prison decides who can open which door, and when. Cards and fobs suit staff who come and go every day, a code suits a door that many hands use, and a key suits a cell door that only staff open.

When the power goes, the door line must fail safe, so staff and prisoners can still leave. The release on power failure belongs in the specification beside the reader, and a door that locks shut in a power cut traps people inside. A lost card should stop working everywhere at once, so it never opens every door.

The system must work as one system across the whole site. A card that opens the main entrance should open the staff areas and the control room, and the card office should be able to stop one card without stopping the rest. Our how to specify security doors guide runs through the same discipline column by column.

One doorset, two duties: fire and forced entry

A cell door can carry a fire period and a forced entry rating together, but the proof for each job has to name the same assembly that will be fitted. Fire is proved by classification to EN 1634-1 and forced entry by a rating to LPS 1175 or PAS 24, and the two proofs sit side by side in our dual certification guide.

What sits behind a cell door decides how long it must hold. A door on an escape route usually takes FD30 and a door in a compartment wall usually takes FD60, and the letters beside the number say what the furnace measured: E for integrity, EW for integrity with limited radiation and EI for integrity with insulation, with periods from 30 minutes up to 120, all of which our fire ratings guide sets out.

A cell door that must keep smoke off the route takes FD30S, with a smoke seal proved to BS EN 1634-3, to Sa for smoke at room temperature and S200 for smoke at 200 degrees Celsius, and the gap round the leaf stays at 4 mm, because a wider gap lets smoke past the seal. Intumescent seals swell at roughly 200 to 250 degrees and close the gap as the heat builds.

The prison order: one schedule for the whole site

Write the order as a specification that lists every prison door on its own line, with the wing, the position, the forced entry rating, the fire period and the smoke seal where one is needed, then the leaf, frame, glass, beads, seals and hardware as one doorset. Ask for the LPS 1175 or PAS 24 rating on the whole doorset wherever a door must resist attack, never on the leaf alone. Our how to specify security doors guide runs through the same discipline column by column.

File the evidence with the doors on arrival. The test report, the classification and the hardware schedule should travel with each doorset, and the handover pack should name the inspection routine the site will follow. The fire door inspection checklist sets out the round in full, and the security door maintenance checklist sets out what the round looks for. The keeping an LPS 1175 rating valid guide sets out what breaks a rating.

Position Door Rating What to check
Cell Steel cell door LPS 1175 D10 Lock, hinges, vision panel
Wing corridor Security door LPS 1175 C5 Closer, seals, latch
Control room Security door LPS 1175 D10 Lock, reader, fixings
Staff room Security door LPS 1175 B3 Lock, closer, seals
Perimeter gate Vehicle gate ISO 22343-1 Motor, fixings, release

A prison door is attacked from the inside by a person with time, so the rating, the hinges and the lock must all sit on the same schedule.

What security rating do prison cell doors need?

Most often D10, the highest LPS 1175 rating, because the person behind the door has time and tools. A corridor door often takes C5 and a staff room door takes B3.

Can one prison doorset hold a fire rating and a security rating?

Yes, where one doorset is tested for both jobs. The fire proof is a classification to EN 1634-1 and the forced entry proof a rating to LPS 1175 or PAS 24, and both must name the doorset fitted.

Do prison doors need to fail safe?

Yes. When the power goes, the doors must release so staff and prisoners can leave, and the release belongs in the specification beside the reader.

What breaks a prison door rating?

A leaf that sags, a hinge that drops, a lock that no longer turns, or a vision panel that has loosened. Repair or replace it, and record the work.

Who checks prison security doors?

The estates team, on the routine the security plan and the fire strategy set. Each record names the door, the fault, the repair and the date.

Specifying security doors for a prison?Send the door schedule and the site plan for a tested doorset quotation.
Get a free quote

Related

More in guides for specifiers

10 mistakes when specifying certified security doors 10 steps to specify an LPS 1175 door Acceptance and Snagging of a Security Door or Barrier Job Access Control Doors Acoustic Doors: Ratings and Specification After a Forced Entry Attempt: Checking a Security Door Airport Security Doors Anti-Ligature Doors for Mental Health Wards Anti-Ram Bollards Anti-ram gates and barriers: protecting vehicle entrances Arcade Security Doors Explained Automatic Doors Automatic Gates Cost Factors Automatic Vehicle Barriers Ballistic Panels Bank Security Doors Bingo Hall Security Doors Explained Blast doors: glazed vs solid and how they are rated Blast protection window film: what it does and what it cannot do Blast resistant windows: what drives the cost and how to specify them Bollard Cost Factors Explained Bollard regulations in the UK: spacing, height and depth Bookmaker Security Doors Explained Builders Merchant Security Doors Bullet Resistant Glass Cost Factors Bullet resistant glass ratings explained: BR1 to BR7 and SG classes Bullet resistant vs bulletproof glass: what the difference means Buying Security Doors and HVM Through Public Frameworks Car Park Security Doors Explained Car Showroom Security Doors Casino Security Doors Explained CDM 2015 Duties When Security Doors, Shutters or HVM Are Installed Cinema Security Doors Cleanroom Doors Cold Store Doors College Security Doors Commissioning, Handover and the O&M Manual for Security Doors and HVM Communal entrance doors for flats: Secured by Design and what to specify Community Centre Security Doors Control Room Doors Court Security Doors Crash Rated Fences and HVM Fencing Explained Data centre physical security: doors, glazing, HVM and shielding by zone Dental Practice Security Doors Depot Security Doors Explained Door Entry Systems Due Diligence When Selecting Vehicle Security Barriers Emergency Exit Doors EMP Shielding Cost Factors Explained Exhibition Centre Fire Door Rules Exhibition Centre Security Doors Factory Security Doors Faraday cage vs RF shielded room: what a business needs FB4 vs FB6 vs FB7: how to choose a ballistic rating Fire and security doors: how dual certification works Fire Compartmentation Fire Curtains Fire Door Certification Fire Door Closers Explained Fire Door Cost Factors Fire Door Duties of the Accountable Person Fire Door Gaps Fire Door Hardware Explained Fire door inspection checklist for steel and timber doors Fire Door Maintenance Fire Door Regulations Care Homes Fire Door Regulations for A and E Departments Fire Door Regulations for Airports Explained Fire Door Regulations for Bowls Clubs Fire door regulations for commercial buildings in the UK Fire Door Regulations for Dialysis Centres Fire Door Regulations for Hockey Clubs Fire Door Regulations for Hospitals Explained Fire Door Regulations for Offices Explained Fire Door Regulations for Operating Theatres Fire Door Regulations for Retail Explained Fire Door Regulations for Schools Explained Fire Door Regulations for Snooker Clubs Fire Door Regulations for Stadiums Fire Door Regulations for Student Accommodation Fire Door Regulations for Warehouses Fire Door Regulations Leisure Centres Fire Door Regulations Restaurants Fire Door Remediation Programme for Housing Providers Fire Door Rules for Badminton Clubs Fire Door Rules for Bingo Halls Fire Door Rules for Bookmakers Fire Door Rules for Bowling Alleys Fire Door Rules for Car Parks Fire Door Rules for Car Showrooms Fire Door Rules for Cinemas Fire Door Rules for Climbing Centres Fire Door Rules for Colleges Fire Door Rules for Community Centres Fire Door Rules for Cricket Clubs Fire Door Rules for Dental Practices Fire Door Rules for Depots Explained Fire Door Rules for Golf Clubs Fire Door Rules for GP Surgeries Fire Door Rules for Gyms Explained Fire Door Rules for Ice Rinks Fire Door Rules for Maternity Units Fire Door Rules for Mental Health Units Fire Door Rules for Museums Fire Door Rules for Oncology Units Fire Door Rules for Opticians Fire Door Rules for Pawnbrokers Fire Door Rules for Petrol Stations Fire Door Rules for Pharmacies Fire Door Rules for Ports Fire Door Rules for Post Offices Fire Door Rules for Prisons Fire Door Rules for Rehabilitation Centres Fire Door Rules for Self Storage Fire Door Rules for Shopping Centres Fire Door Rules for Squash Clubs Fire Door Rules for Supermarkets Fire Door Rules for Swimming Pools Fire Door Rules for Tennis Clubs Fire Door Rules for Theatres Fire Door Rules for UK Arcades Fire Door Rules for UK Casinos Fire Door Rules for UK Hospices Fire Door Rules for Walk-in Centres Fire Door Signage Fire Door Vision Panels Fire Doors and Gateway 2 in Higher-Risk Buildings Fire Rated Glass Cost Explained Fire Rated Sliding Doors Explained Fire Rated Windows Cost Factors Fire Rated Windows Explained Fire Safety Enforcement Notices and Fire Doors: What the Responsible Person Must Do Flat Entrance Doors: PAS 24 and Fire Rated Forced Entry vs Ballistic vs Blast: Which Rating a Site Needs Garage Security Doors Explained Gate Automation Explained Golden Thread Records for Fire Doors GP Surgery Security Doors Explained Gym Security Doors Explained High Speed Doors HMO Fire Doors Hospice Security Doors Explained Hospital Security Doors: Wards, A&E, Plant Hospital Security Gates Hotel Fire Doors Hotel Security Doors How to choose HVM bollards: fixed, shallow mount, removable and automatic How to keep an LPS 1175 door rating valid after installation How to Specify Fire Doors in a Housing Tender How to specify security doors: a checklist for architects How to Verify a Secured by Design Listing How to Verify an LPS 1175 Certificate on Red Book Live How to Write an Operational Requirement for Physical Security HVM planters and street furniture: protection that blends in In-Service Care of Vehicle Security Barriers Installation Handover: LPS 1175 Doors and PAS 68 Barriers Intumescent Seals ISO 16933 explained: EXV and SB classes and hazard ratings ISO 22343 vehicle security barriers explained Keeping a Dual-Certified Fire and Security Door Valid in Service Laboratory Security Doors Layered Security for a Site: Deter, Detect, Delay, Mitigate, Respond Lead Times and Programme Risks for LPS 1175 Doors Leisure Centre Security Doors Library Security Doors Listed Building Fire Doors Loading Bay Doors Explained Lockdown and Access Control Hardware on an LPS 1175 Door LPS 1175 Gates and Grilles Explained LPS 1175 Issue 8 explained: from SR1 to SR8 to A1 to H20 LPS 1175 Roller Shutters LPS 1175 vs ASTM F2781 and Other US Ratings Explained LPS 1175 vs EN 1627: how UK and European burglar resistance ratings compare LPS 1175 vs PAS 24: which security standard does your door need? LPS 1175 Windows and Walling Explained Martyn’s Law and Places of Worship: What a Buyer Checks for Doors and Entry Control Martyn’s Law Enhanced Tier: Physical Measures and the Specifier Brief Martyn’s Law Standard Tier: Procedures, Doors and Shutters Martyn’s Law Timeline and the SIA Regulator Martyn’s Law: what premises must do and which physical measures to consider Master Key Systems MRI and RF shielded rooms: how they work and what to specify Museum Security Doors NPSA Catalogue of Security Equipment (CSE) Explained NPSA Forced Entry and Blast Guidance for Government Sites NPSA Guidance on Lockdown and Marauding Attack: What It Asks of Doors and Entrances Office Security Doors Optician Security Doors Explained Panic Hardware PAS 24 requirements for doors and windows explained PAS 68 Bollard Foundations Explained PAS 68 bollards: ratings, spacing and cost factors PAS 68 vs IWA 14 vs ISO 22343: hostile vehicle mitigation standards explained Pawnbroker Security Doors Explained Pedestrian Gates Petrol Station Security Doors Pharmacy Security Doors Planning Permission for Security Shutters, Gates and Bollards on Commercial Premises Plant room doors: fire, security and ventilation requirements Plant Room Fire Doors Port Security Doors Post Office Security Doors Explained Powder coating vs galvanising vs paint for steel Preliminary Market Engagement for Security Doors and HVM Programming a Security Door and Barrier Package on a Live Site Public-Sector Tender Response Checklist for Security Door and HVM Supply Reading a PAS 24 and SBD Door Test Report Regulation 38 Fire Safety Information at Handover for Fire-Rated Security Doorsets Replacing Security Doors in an Occupied Building Restaurant Security Doors Retail Security Doors Revolving Doors RF shielding standards and how shielded rooms are tested Rising Bollard Cost Factors Road Blocker Cost Factors Explained Road Blockers Explained Roller Shutter Cost Factors: What Drives the Price Roller shutter regulations in the UK: safety and maintenance Safe room and panic room doors: specification basics Safety Duties for Powered Doors, Gates and Barriers on Commercial Sites School Security Doors Sectional Doors Secured by Design explained: is it mandatory for doors? Secured by Design vs NPSA vs LPCB: Which One You Need Security Door Locks Security Door Maintenance Checklist Security Doors and Access for Everyone: What Approved Document M Asks Security Doors for A and E Departments Security Doors for Badminton Clubs Security Doors for Bowling Alleys Security Doors for Bowls Clubs Security Doors for Climbing Centres Security Doors for Cricket Clubs Security Doors for Dialysis Centres Security Doors for Golf Clubs Security Doors for Hockey Clubs Security Doors for Ice Rinks Security Doors for Maternity Units Security Doors for Mental Health Units Security Doors for Oncology Units Security Doors for Operating Theatres Security Doors for Rehabilitation Centres Security Doors for Snooker Clubs Security Doors for Squash Clubs Security Doors for Swimming Pools Security Doors for Tennis Clubs Security Doors for Walk-in Centres Security Doors West Midlands Explained Security Fencing Security Gates Cost Factors Explained Security shutters vs high performance roller doors Security shutters vs retractable grilles: which suits retail and commercial openings? Security Turnstiles Explained Security Window Film Security Windows for Schools Explained Self Storage Security Doors Server Room Doors Explained Shopping Centre Security Doors Smoke Control Doors Explained Smoke Curtains Specification Mistakes When Mixing LPS 1175, PAS 24 and SBD in One Tender SR2 vs SR3 vs SR4 security doors: choosing the right LPS 1175 level Stadium Security Doors Steel Door Frames Steel vs aluminium security doors: strength, ratings and looks Steel vs timber fire doors: which suits your building? Student Accommodation Security Doors Substation doors: security, ventilation and specification Supermarket Security Doors Telescopic Bollards Tender Evaluation Criteria and Scoring for Security Doors and HVM The Scope of a Maintenance Contract for Security Doors and Barriers Theatre Security Doors Thermal and Weather Performance of External Security Doorsets Thermally broken steel security doors: U-values and certification Traffic Calming as Hostile Vehicle Mitigation Transport hub security requirements Turnstile Cost Factors Explained Turnstile vs speed gate vs security portal: choosing entrance control Types of security doors for commercial buildings University Security Doors Explained Vehicle Dynamics Assessment: What It Tells the Buyer Before a Barrier Is Specified Warehouse Security Doors Explained Warehouse Security Gates Warranty, Defects Liability and Guarantees for Security Doors and Barriers What affects the cost of a bullet resistant door What affects the cost of a high-security door in the UK Window Security Bars View all →

Products

One supplier for the whole building envelope

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.