ArxBridge
Security Doors for Bowling Alleys
A bowling alley takes cash at the desk and fills at night, so each leaf takes the LPS 1175 grade its room demands, B3 at the entrance and D10 behind the cash.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A bowling alley stays open late, takes cash at the desk and fills its lanes with groups who arrive together and leave together. The entrance takes the crowd in, the cash desk takes the money, the lane hall holds the lanes and the shoe hire, the back office holds the bookings and the float, the plant room keeps the pinsetters running, and the cash counting room holds the takings.
LPS 1175 Issue 8.2, dated September 2024, grades a leaf by the minutes it stands against the tools the test names. A B3 leaf holds for three minutes, a C5 leaf holds for five minutes and a D10 leaf holds for ten minutes, and an old drawing may still name the same three leaves SR2, SR3 and SR4, so the order carries both names beside each leaf.
A bowling alley is not an arcade, because the play sits on lanes with hired shoes rather than on machines, and it is not a cinema, because the crowd watches its own game rather than a screen, and it is not a leisure centre, because the floor holds lanes rather than a pool. The security doors for cinemas guide grades the doors of a building that seats a crowd in the dark, and the leisure centre security doors guide grades the doors round pools and sports halls.
- B3 / C5 / D10Grades to LPS 1175 Issue 8.2
- Cash counting roomWhere D10 sits in the alley
- Late-night crowdWhere the grade meets the door
- One listEvery alley leaf named
Six rooms in a bowling alley: the grade each leaf takes
Six rooms make up a bowling alley, and the grade follows what each room holds. The entrance takes the crowd in, the cash desk takes the money, the lane hall holds the lanes and the shoe hire, the back office holds the bookings and the float, the plant room keeps the pinsetters running, and the counting room holds the takings.
B3 sits on the entrance, the cash desk and the lane hall, because all three stand where staff and bowlers can see them through the night. C5 goes on the back office and the plant room, because the bookings, the float and the plant behind those leaves ask for a longer hold than the public rooms. The counting room takes D10, because the takings behind it are the most portable value in the building.
Each opening takes a line of its own on the order, naming the leaf, the grade and the minutes, so the fitter can match every leaf to its line before it is hung.
| Room | Grade | Minutes | What to check |
|---|---|---|---|
| Entrance | B3 | 3 | Leaf, lock, closer |
| Cash desk | B3 | 3 | Leaf, lock, reader |
| Lane hall | B3 | 3 | Leaf, lock, closer |
| Back office | C5 | 5 | Leaf, lock, reader |
| Plant room | C5 | 5 | Leaf, lock, seals |
| Cash counting room | D10 | 10 | Leaf, lock, hinges |
A leaf in the alley may need to hold fire as well as forced entry, and the two proofs sit in one report. EN 1634-1 counts the fire minutes from 30 to 120, with E for flames alone, EW for flames with part of the heat held back and EI for flames with the heat held back as well. The fire and security doors dual certification guide shows the two proofs on one leaf, and the SR2 vs SR3 vs SR4 guide puts the old names beside the new grades.
The entrance and the cash desk: B3 where the public stands
Bowlers pass through the entrance in groups through the night, and the leaf between the street and the desk stays shut and locked between each pass. The leaf must open fast to a card or a key in staff hands, and it must shut fully behind them. The leaf behind the counter takes B3 and stays shut while the till is open.
The entrance asks for three minutes because it stands in sight of the staff at the desk. A reader on the street side opens the leaf to staff cards, and a key override stands behind the reader for the night the reader fails. The access control doors guide covers readers and locks on an alley leaf, and the door entry systems guide covers the panel that lets staff through from the street.
BS 8300 and Approved Document M put a limit on how hard a leaf may push back, below 30 N through the first 30 degrees of swing and below 22.5 N beyond that, so a bowler carrying shoes and a bag can still push the entrance leaf open. The closer is proved to BS EN 1154, with EN 1 the smallest power size.
The lane hall: a B3 leaf at the end of the lanes
The lane hall holds the lanes, the seating and the shoe hire, and the leaf at the end of the hall stands between the bowlers and the rooms behind it. Bowlers move between the lanes and the counter all night, so the leaf must open to a push and shut behind the last person through. Three minutes is the hold the leaf takes, because the hall stays lit and watched from the desk through the night.
Shoe hire sits at the counter end of the hall, so the leaf between the hall and the desk is worked more than any other leaf in the building. Hinges proved to BS EN 1935 hang the leaf, grade 13 carrying 120 kg and grade 14 carrying 160 kg, each proved through 200,000 cycles, so the leaf hangs true after a night of constant use and the bolt still finds its keep.
Cash counting room: D10 behind the takings
The cash counting room holds the takings, so its leaf takes D10, the longest hold LPS 1175 Issue 8.2 names. Leaf, frame, fixings and lock went through the test as one doorset, and the report puts ten minutes against the tools the test names, because the notes counted inside are the easiest value in the building to carry out. No published table sets LPS 1175 grades beside ASTM ratings, so the order names the LPS grade and nothing else.
No glass sits in the counting room leaf, because a pane would show the hall what the room holds and put a hand within reach of the lock. A D10 leaf hangs on hinges proved to BS EN 1935, with grade 13 proved for 200,000 cycles at 120 kg and grade 14 proved for 200,000 cycles at 160 kg, so the weight of the leaf never pulls the bolt out of line with its keep.
Under TS 007, a 1 star cylinder beside a 2 star handle makes a 3 star set, so the cylinder and the handle are ordered as a pair. The security door locks guide names what the lock on the counting room must do, and the keys to the room are held by named staff only.
Back office and plant room: C5 on the rooms behind the desk
Bookings, the float and the papers that record the night sit in the back office, so its leaf takes C5 and stays locked when no one is inside, because an open office hands a passer by the float and the keys to every room behind it.
Boards and equipment in the plant room keep the pinsetters, the lights and the air moving, so the leaf on that room takes C5. What a plant room leaf must do is covered in full in the plant room door requirements guide.
Staff pass between the back office and the desk through the night, so the leaf between them must shut on its own each time. A closer proved to BS EN 1154 shuts the leaf without a hand on it, and EN 3 is the minimum power size a fire door takes.
Locks, readers and keys: who opens which leaf after dark
Each leaf behind the cash desk opens to the cards and keys of the staff who work there, and a card held on the public side opens none of them. How a key plan gives each holder the rooms their work needs and no other room is shown in the master key systems guide.
The duty manager holds a key that opens every leaf behind the desk, and the lane staff hold keys that open only the rooms their shifts take them to. How the order runs from the first leaf to the last is set out in the 10 steps to specify an LPS 1175 door guide. A lost card is taken off the reader list the night it is reported, so a card found on the lane floor opens nothing.
Bollards, crowds and the door at closing time
Groups leave together at closing time, and the entrance leaf must let a crowd out fast while keeping a vehicle off the frontage. Where the route serves a crowd, the leaves on the way out carry a push bar proved to BS EN 1125, and the bar spans at least 60 percent of the leaf width, so a person reaching the leaf in a crowd opens it with one push. What the bar must do when people push against the leaf is set out in the panic hardware guide.
Martyn’s Law received Royal Assent in April 2025, with go-live expected in spring 2027, and it sets two tiers by the number of people a premises may hold, 200 to 799 on the lower tier and 800 or more on the higher tier. A bowling alley that may hold a crowd of that size sits inside those tiers. The Martyn’s Law guide for premises names what each tier asks of the building.
Bollards on the frontage keep a vehicle from the entrance while the crowd leaves, and ProtectUK puts the clear gap between bollards at no more than 1,200 mm, with a minimum height of 500 mm. How the frontage is laid out is covered in the choosing HVM bollards guide.
The bowling alley order: every leaf, its grade and its lock
One list carries the whole bowling alley order, with a line for every opening that names the leaf, the grade, the lock and the closer beside it. A leaf with no line of its own may be hung where it does not belong, and a C5 leaf on the counting room holds for five minutes where the takings ask for ten.
The duty manager takes the door list round the alley each month and tries the leaves in turn. A dragging leaf, a bolt that misses its keep or a reader that stays silent goes on the list beside its own door the day it is found, and the security door maintenance checklist names what the walk should cover.
Each leaf on the order is read before the order is signed, because a closer that arrives after the doorset holds the job up. The how to specify security doors guide sets out what the order must hold for every door, and the steel door frames guide names how the frame holds the leaf and the lock together.
The grade on a bowling alley leaf follows the room behind it, so the leaf, the lock and the reader are ordered together and checked together against the cash and the crowd behind the leaf.
What grade does a bowling alley entrance take?
B3 to LPS 1175 Issue 8.2, which holds for three minutes, because the entrance stands in view of the staff at the cash desk through the night.
What grade does a cash counting room take?
D10 to LPS 1175 Issue 8.2, which holds for ten minutes, because the takings sit behind a leaf that is shut and locked whenever no one is counting inside.
What grade does a lane hall leaf take?
B3 to LPS 1175 Issue 8.2, which holds for three minutes, because the lane hall stays lit and watched from the desk while bowlers play.
Can one leaf hold fire and forced entry?
Yes, where the same leaf was proved against fire and against forced entry, so one report carries the period and the grade together.
Who checks the bowling alley doors?
The duty manager walks the alley with the door list each month and tries the leaves in turn, so a fault is found and put right.
Get a free quote
Related
More in guides for specifiers
Products
One supplier for the whole building envelope
Ready to specify your project?