A hospice holds people who cannot move quickly beside rooms that hold drugs and plant, so each door takes the fire period that its room demands.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A hospice is a building of bedrooms, a reception and a drugs store behind one entrance, and the fire rules for the building follow the rooms behind each leaf. The bedrooms hold people who cannot move quickly, the drugs store holds the controlled drugs, and the staff office and the plant room hold the keys and the boards.
EN 1634-1 is the test that counts the fire minutes on a hospice leaf. FD30 means thirty minutes and FD60 means sixty, and the letter beside the minutes says what the leaf held back: E for flames alone, EW for flames with some heat held back and EI for flames with the heat held back.
A hospice follows the same rules as any other building where the people inside cannot move quickly. The fire door regulations care homes guide covers the fire rules for a home where residents live for years, and the care-home detail is not repeated here, while the fire door regulations hospitals guide covers the rooms behind a hospital ward.
- FD30 / FD60Fire periods to EN 1634-1
- BedroomsWhere the slow move out starts
- Sa / S200Smoke ratings to BS EN 1634-3
- One listEvery hospice door named
Five hospice rooms and the period that protects each one
Five parts make up a hospice, and the period follows what each part holds. The entrance and the reception hold the families coming in, the drugs store holds the controlled drugs, the staff office holds the keys and the rotas, and the plant room keeps the building running.
FD60 sits on the drugs store, the staff office and the plant room, because those rooms need sixty minutes before the fire reaches them. FD30 sits on the entrance and the reception, because the families on that route can move to the street in far less than thirty minutes.
Every opening in the hospice gets a line of its own on the order, with the leaf and the period written beside it, so no leaf is hung on guesswork. The fire door regulations hospitals guide covers the fire rules for a building where patients also move slowly, and the fire door regulations GP surgeries guide covers the rooms behind a surgery waiting room.
| Position | Leaf | Period | What to check |
|---|---|---|---|
| Drugs store | Steel leaf | FD60 | Leaf, lock, seals |
| Staff office | Steel leaf | FD60 | Leaf, lock, seals |
| Plant room | Steel leaf | FD60 | Leaf, lock, seals |
| Reception | Glazed leaf | FD30 | Leaf, glass, closer |
| Entrance | Glazed leaf | FD30 | Leaf, glass, closer |
What FD30 and FD60 hold back in a hospice
The minutes on a leaf come from the test, and the doorset that earns them is the leaf, the frame, the fixings and the lock proved as one. What the report states is what the order writes beside the leaf, so the leaf that arrives is the leaf the room asked for.
Some leaves in the hospice must hold fire as well as forced entry, and one doorset carries both proofs in one report. The fire minutes come from EN 1634-1 and the forced entry grade from LPS 1175 Issue 8.2 of September 2024, in B3, C5 and D10, and the fire and security doors dual certification guide shows how the two proofs sit on the same leaf. How the letters and the minutes go together is set out on the fire ratings standard page.
Smoke reaches the people on the way out before flame does, so the leaves on the route carry a smoke rating beside their fire period. BS EN 1634-3 names the two ratings, Sa for smoke at room temperature and S200 for smoke at 200 degrees, and the smoke control doors guide works through how the route leaves keep the smoke back while families move past them.
The drugs store, the staff office and the plant room: FD60 behind shut leaves
Behind the drugs store leaf sit the controlled drugs the hospice runs on, so the leaf takes FD60 and stays shut when no one is drawing up a dose. Sixty minutes is the hold the room asks for, because the drugs behind it cannot be replaced.
The staff office holds the keys, the rotas and the papers, and its leaf takes FD60 for the same reason, because the keys behind it are what the hospice opens with each day. A leaf that stands open through the night holds nothing back, so the staff office leaf is shut each time the last person leaves the room.
The plant room holds the boards and the equipment that keep the lights and the heating running, and its leaf takes FD60 because the boards behind it feed the whole hospice. The plant room fire doors guide takes the leaves of a plant room in full, and the plant room door requirements guide takes the doors that guard the plant.
Bedroom doors in a hospice: the leaf beside the bed
A hospice bedroom is where a person spends their last days, so the leaf on it must shut on its own and hold fire for thirty minutes while help reaches the bed. The bedroom leaf takes FD30, because the person inside cannot move quickly and the leaf must hold the corridor clear long enough for help to arrive.
The lock on a bedroom leaf takes a thumb turn on the bedroom side, so the person inside can leave without a key, and a key on the corridor side, so staff can open the leaf from the corridor. A glazed panel in the leaf lets a nurse look in without opening it, and the panel is proved with the leaf round it. The fire door vision panels guide covers the panels a fire leaf may carry.
Bedroom leaves are opened and shut through the night as nurses check on the people inside, so a leaf that is wedged open holds nothing back when the alarm sounds. Only a hold-open device proved to BS EN 1155 may hold a bedroom leaf open, because it lets the leaf shut on its own when the alarm sounds, and a wedge is not a hold-open device.
The entrance and reception: FD30 on the route visitors use
Families stand at the reception desk and move to the street through the entrance, so both leaves take FD30. Thirty minutes is more than the families need to leave, and the route behind the leaves is short.
Where the route serves a crowd, a bar proved to BS EN 1125 sits across at least 60 percent of the leaf width, so a visitor who reaches the leaf in a crowd opens it with one push. What the bar must do for a crowd pushing against the leaf is covered in the panic hardware guide, and the leaves on the way out are covered in the emergency exit doors guide.
A glazed panel in the reception leaf lets the staff see the families waiting without opening the leaf, and the pane is proved with the leaf round it. The steel vs timber fire doors guide sets the two leaf materials beside each other.
Getting residents out: the slow route from the bedroom to the street
When the alarm sounds, the people in the bedrooms cannot walk fast, so the route out is planned round beds and chairs rather than people on their feet. The corridor from each bedroom runs straight to the stair or the exit, with no turn a bed cannot take, and nothing stands in it.
Staff move the residents along the route, and the leaves on the way must open with one push from hands full with a bed or a chair. The force to open a leaf on the route stays below 30 N for the first 30 degrees and below 22.5 N beyond them, to BS 8300 and Approved Document M, so a nurse pushing a bed can open the leaf without stopping.
Under Martyns Law, premises fall into tiers by the number of people they hold, one tier for 200 to 799 people and a higher tier at 800 and above, and the Martyns Law guide for premises sets out what each tier asks for. Whether a hospice sits in a tier turns on the number of people in the building, so the count is checked before the tier is named. Royal Assent came in April 2025 and the go-live is expected in spring 2027, so the route is planned now.
Closers, seals and gaps on hospice doors: the parts that wear first
The gap round a hung leaf is measured with a gauge, and a hinge or a frame that has shifted shows up as a gap that has grown past 4 mm. When heat of 200 to 250 degrees reaches the seal in the groove, the seal swells until it closes the gap, and paint over the seal stops it swelling, so the seal is looked at with the gap.
A fire door closer takes at least EN 3, the smallest power size the rules allow, and the leaf it serves must shut on its own from whatever angle it is opened to. BS EN 1154 runs the power sizes from EN 1, for a leaf 750 mm wide and 20 kg in weight, up to EN 7, for a leaf 1,600 mm wide and 160 kg in weight.
The hinges that carry the leaf come from BS EN 1935, where grade 13 is proved for 200,000 cycles at 120 kg and grade 14 for 200,000 cycles at 160 kg. What the hardware on a fire leaf must do is covered in the fire door hardware guide, and the closers are covered in full in the fire door closers guide.
The hospice fire door order: every leaf, its period and its proof
Every opening in the hospice gets a line on the order, with the leaf, the period, the lock and the closer written beside it. A single leaf named for the whole hospice leaves the fitter to guess, and a leaf in the wrong room holds fire for the wrong time.
Before the order is signed, each leaf on it is checked, because a closer ordered after the doorset arrives holds the job up, and a leaf with no line beside it cannot be checked when it arrives. What the order must hold for every door is covered in the how to specify security doors guide.
The faults that show first are a leaf that will not shut, a closer that leaves the leaf standing open and a seal that has been painted over, and each one is written against its own door on the day it is found. What to look for on each leaf is covered in the fire door inspection checklist, and the work that keeps the leaves holding is covered in the fire door maintenance guide.
The period on a hospice leaf means nothing on its own, so the leaf, the closer and the seal are ordered together and checked together against the room behind the leaf.
What period should a hospice fire door carry?
FD60 for the drugs store, the staff office and the plant room, and FD30 for the entrance and the reception, each proved to EN 1634-1.
Can one leaf hold fire and forced entry?
Yes, where the same doorset passed the fire test and the forced entry test together, so the period and the grade are named in one report.
Do hospice fire doors need a smoke rating?
Yes, Sa or S200 to BS EN 1634-3 sits beside the period on the route leaves, because smoke reaches the people on the way out before flame does.
Who checks the hospice fire doors?
The hospice manager keeps the door list and looks over the leaves in turn, so a leaf that will not shut is found before the leaf is asked to hold.
What happens when a hospice fire door will not shut?
A leaf that will not shut is written up against its own door the day the fault is found, and the hospice does not wait for the next look round before the leaf is put right.