FB4 vs FB6 vs FB7: how to choose a ballistic rating
FB4 vs FB6 vs FB7 for UK specifiers: match the ballistic rating to the assessed threat, see what each step up changes, and protect the whole line of openings.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
Choose the class that matches the assessed threat: FB4 for handguns up to .44 Magnum, FB6 for rifles up to 7.62×51, FB7 for armour piercing 7.62×51 hard core. The right rating is the lowest class that defeats the credible threat across the whole protected line.
- StandardEN 1522 rates the complete assembly; EN 1063 rates the glass alone
- ClassesFB1 to FB7, plus FSG for shotgun
- Big stepThe jump from handgun classes to rifle classes
- Golden ruleEvery opening on the attacked face shares the class
Start from the threat, not the number
Most selection mistakes begin with the class. A specifier chooses FB7 because it is the highest number, or FB4 because it sounds sufficient, and the building inherits the guess. The standard works the other way round: the threat decides the class, and the design follows.
A threat is a person with a weapon and a reason to reach your building. Some sites face handguns; others face rifles. Name the weapon first and the class table answers itself. Our guide to ballistic ratings sets out the full EN 1522 and EN 1063 tables.
Another common error is borrowing ratings from other industries. Vehicle armour uses its own B scale, and forced entry uses LPS 1175; neither maps onto EN 1522 classes. A B6 vehicle and an FB6 door were tested against different threats under different standards, so the numbers do not transfer.
What each FB class is tested against
EN 1522 tests complete assemblies: the door, window or shutter together with its frame, glazing and fixings. Each class names the ammunition the assembly must stop, and the table below lists every class in the standard.
| Class | Ammunition |
|---|---|
| FB1 | .22 LR |
| FB2 | 9mm |
| FB3 | .357 Magnum |
| FB4 | .357 Magnum and .44 Magnum |
| FB5 | 5.56×45 rifle |
| FB6 | 5.56×45 and 7.62×51 rifle |
| FB7 | 7.62×51 hard core (armour piercing) |
| FSG | Shotgun |
Two footnotes deserve attention. FSG covers shotgun and sits outside the numbered sequence. The suffix S or NS records whether fragments leave the protected face; NS means none do, which matters wherever people stand behind the glass.
Keep the class consistent across doors, windows, and shutters on the same face. Mixed classes on one elevation complicate the test evidence and the installation, and they give the attacker an obvious choice.
Which buildings typically choose which class
Handgun classes suit sites where the credible threat stops at handguns: high street banks, jewellers, cash offices, and pharmacies holding controlled drugs. FB4 is the usual ceiling here because it covers the heaviest common handgun rounds. Our banking sector guide shows how these ratings are applied across branch estates.
Rifle classes suit sites where rifles are credible: embassies, government buildings, police stations, and parts of the critical national infrastructure. FB6 is the workhorse of this group; FB7 is reserved for sites where armour piercing ammunition is a named threat. See how government and defence sites are typically specified.
Treat these as patterns, not rules. A jeweller facing a known firearms risk can need more than a quiet town bank. Only the threat assessment settles it, which is why the assessment should always come before the class.
Residential work follows the same logic at a smaller scale. Private clients under specific threat usually need handgun classes on bedrooms and safe rooms, with the assessment defining which rooms and which faces.
Why a threat assessment should come first
A threat assessment names the actors, their likely weapons, and how they would approach the building. It turns a vague aim like “we want to be safe” into a precise instruction: FB6 on the ground floor east elevation, FB4 elsewhere.
Without one, projects drift in two expensive directions. Some overspecify and pay for protection the threat never justified. Others leave gaps at the openings nobody considered, such as the louvred vent beside the rated door.
A security consultancy engagement produces exactly this document. Send it with your enquiry and the specification almost writes itself: a class for each opening, S or NS, and the line of protection marked on plan.
Threat first, class second: the order that keeps the rating honest
A ballistic rating is chosen from the threat, not from the catalogue. The threat names the weapon, the distance and the people behind the door, and the class follows from those three facts.
The FB classes run from FB1 to FB7 under EN 1522 and EN 1523, for windows, doors and shutters, with FSG for shotgun resistance. The BR classes run from BR1 to BR7 under EN 1063, for the glass alone, with SG1 and SG2 for shotgun. A door is ordered by its FB class, and the pane inside it is ordered by its BR class, because BR names the glass and FB names the finished assembly.
Handgun rounds sit at the lower end of the scale and rifle rounds at the upper end, with the build-up growing thicker and heavier at each step. A class above the threat adds layers, weight and cost without adding safety, and a class below the threat leaves the room unproved, so the order names the class the threat asks for and no higher.
Spall decides whether the people behind the glass stay safe. S means splinters reach the safe side, and NS means none do, so a door that guards people standing behind it needs NS beside the class, while a door that guards stock alone may not. The mark belongs on the schedule beside the class, because a door ordered without it may stop the round and still fail the room.
The whole line takes the rating, not just the door. A rated leaf set in a frame never tested with it has no FB rating, so the test report must name the assembly that will be fitted, pane, frame and fixings together. A report that names the glass alone leaves the frame and the fixings unproved.
One line, one proof: the schedule that names the whole assembly
UL 752 runs a separate scale, Levels 1 to 10, and it covers ballistic resistance only. A level on that scale is not a stack of the levels below it, so a specification that asks for a UL level should ask for the UL test report behind it, and should not read a UL level as an EN class. Our ballistic ratings page sets out the scales side by side.
The same door may also have to stand up to a hand tool. EN 356 grades that attack from P1A to P8B, and the top three classes are set by axe blows: P6B takes 30 to 50, P7B takes 51 to 70, and P8B takes 70 or more. A door that needs both proofs needs both test reports, one for the bullet and one for the axe, and the order should name both classes on the same line. Our ballistic glass ratings guide sets out the BR classes, and our bullet-resistant versus bulletproof glass guide clears up the names.
Forced entry is a separate proof from ballistic resistance, and the two should never share a line on the schedule. LPS 1175 grades a doorset on the tools it resists and the minutes it holds, B3 for three minutes against category B tools, C5 for five minutes against category C tools and D10 for ten minutes against category D tools, under Issue 8.2, dated September 2024. A door that needs both proofs needs a test report for each, and the bullet-resistant glass cost guide works through what each added proof does to the build.
| Class | Threat it is proved against | What the order names |
|---|---|---|
| FB1 to FB2 | Handgun rounds | Class, S or NS, leaf size |
| FB3 to FB4 | Heavy handgun rounds | Class, S or NS, leaf size |
| FB5 to FB7 | Rifle rounds | Class, S or NS, frame and fixings |
| FSG | Shotgun pellets | Class, S or NS, leaf size |
File the threat assessment with the order, so the next reader can see why the class was chosen and what it was proved against.
What each step up changes: weight, size and design
The largest jump in the table is FB4 to FB5, handgun to rifle. Rifle rounds carry far more energy, so the construction changes completely: thicker leaves, heavier glazing, deeper frames, and stronger fixings throughout.
Weight becomes the practical limit. Each step up adds mass to every leaf and pane, which changes the hinges, the operators, and the structure that carries them. Large openable windows get harder to achieve, and fixed lights become the sensible answer at the upper classes.
The design follows the weight. Deep frames need deeper reveals; heavy doors need floors that can carry them and clear space to swing. None of this argues against a class. It argues for involving the manufacturer before the opening sizes are fixed on the drawings. Rated security doors show how leaf, frame and hardware are engineered as one system.
Lead time follows the same curve. Higher classes mean more material, more testing documentation, and fewer standard components, so manufacture takes longer and the programme should reflect it from the start. Ordering the class late is the most common cause of delay on ballistic projects.
Each step up in rating changes weight, size and cost. Our guide to what affects the cost of a bullet resistant door breaks down the cost drivers without giving prices.
Protect the whole line, not just the door
A line of protection is only as strong as its weakest opening. An FB7 door beside an unrated window is an unrated line, because the test evidence for the door says nothing about the glass next to it.
Walk the line on plan and list everything on the attacked face: bullet resistant windows, bullet resistant glass in curtain walling, louvres, hatches, and the frames and fixings around each one. Every element needs the same class, or the rating on the strongest element is decoration. Where the threat is blast rather than bullets, the same line logic applies; our guide to blast resistant windows explains what drives their specification and cost.
The expensive mistake. Specifying FB7 everywhere “to be safe” adds weight and lead time while one unrated side window still decides the outcome. Match the class to the assessed threat, then apply it to every opening on the line.
S and NS: decide about spall
Stopping the bullet is half the test. The other half is what leaves the inside face. With an S classification, fragments are ejected toward the protected side; with NS, the assembly holds them.
Choose NS wherever people work or queue close behind the glazing: counters, receptions, and guard posts. For the full picture, browse the guides hub alongside our guide to bullet resistant glass ratings, which explains the BR classes and the S and NS suffix in detail.
Frequently asked questions
Is FB6 enough protection against rifles?
FB6 is tested against 5.56×45 and 7.62×51 rifle rounds, so it is the standard answer where rifles are credible. Step up to FB7 only where armour piercing 7.62×51 hard core is a named threat.
Can I fit an FB4 door with FB6 windows?
You can, but the line rates at FB4. Money spent on the stronger windows buys nothing until the door matches, so keep one class across the attacked face.
What does the NS suffix change?
NS means no splinters leave the protected face. Specify it for counters, receptions, and any position where people stand close behind the glass.
Does a bank branch need FB7?
Rarely. Most branches face handgun threats, so FB4 is the usual ceiling. A threat assessment should confirm this rather than habit or guesswork.
Does the frame need the same rating as the door?
Yes. EN 1522 tests the complete assembly, frame and fixings included. A rated leaf in an unrated frame is not a rated doorset.
Get a free quote