HMO Fire Doors
HMO fire door rules: FD30 and FD60 bedroom doors, flat entrance doors, closers, hinges, seals, smoke control and one schedule for the whole property.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A house in multiple occupation holds several households under one roof, and the doors between them carry the fire rating for the whole building. Each bedroom door, each flat entrance door and each door on the stair core must hold fire and smoke long enough for everyone inside to reach the street, and a door that fails in one room puts every other room at risk.
The risk in an HMO sits in the rooms people sleep in and the corridors they share. A fire that starts in one bedroom meets the corridor through the bedroom door, and a corridor full of smoke stops everyone behind it from leaving, so the doors on that route matter more than any other part of the building.
Flat entrance doors carry a different job from bedroom doors, and our flat entrance doors guide works through the two proofs one leaf must carry, while the student accommodation fire door regulations guide covers a building where the same shared-corridor risk runs through every floor.
- FD30 / FD60Fire resistance periods tested to EN 1634-1
- BS EN 1634-3 Sa / S200Smoke leakage classes
- 4 mmMaximum gap round a fire door leaf
- LPS 2081 SRA / SRBOne and three minutes against a quiet attack
Bedrooms, corridors and stair cores: where an HMO puts its fire doors
A bedroom door in an HMO is the line between a sleeping person and the corridor outside. It must hold fire back for its period and keep smoke off the route, and it must shut every time it is opened, because a bedroom door left open is a corridor full of smoke.
The stair core is the way out for everyone above the ground floor, and the doors that open onto it carry the same duty as the stair itself. A door on the stair that fails lets fire into the one route nobody can do without, so the stair doors take the period the fire load behind them asks for.
Corridor doors divide the route into parts, so a fire in one part meets a door before it meets the next. Cross-corridor doors hold smoke back while people move past them, and a door on the escape route must open freely from the inside, with no key, no card and no code between the person and the street.
FD30 and FD60 in an HMO: the period each door carries
Thirty minutes is the period most bedroom doors carry, and sixty minutes is the period for the doors that guard a compartment wall or a room with a heavier fire load. The number names the minutes the door held, and the letter names what the furnace measured: E for integrity, EW for integrity with limited radiation and EI for integrity with insulation.
A door proved to EI 60 weighs more than a door proved to E 30, and the hinges, the closer and the fixings must be chosen for the leaf that arrives, not for the leaf the drawing shows. A longer period than the room needs only makes the leaf heavier, so the order should name the period the fire load asks for and nothing more. Steel and timber leaves behave differently in a fire, and the choice is worked through in our steel versus timber fire doors guide.
Proof belongs to the fitted doorset, not to the leaf on its own. Ask for the test report on the door, the frame and the hardware as one assembly, and check that the frame on site matches the frame in the report, because a leaf in the wrong frame carries no proof at all. Our fire rated steel doors guide covers the steel leaves that carry the higher periods.
The flat entrance door: fire and security on one leaf
A flat entrance door in an HMO must do two jobs at once. It must hold fire back for its period, and it must resist a forced entry, because the door between a flat and the shared corridor is the one a thief tries first and the one a fire meets first.
The forced entry proof comes from LPS 1175, with B3 holding three minutes against category B tools, C5 holding five minutes against category C tools and D10 holding ten minutes against category D tools, all under Issue 8.2, dated September 2024. The ratings in full are on our LPS 1175 page.
A flat that empties at night faces a quiet attack, and LPS 2081 answers it: SRA for one minute and SRB for three minutes against an attack that tries not to be heard. The rating belongs on the schedule beside the fire period, because a door that holds fire and opens to a quiet hand has failed half its job.
For the lock, ask for a TS 007 3-star set, a 1-star cylinder with a 2-star handle or escutcheon, and fit a thumb turn on the inside so the person in the flat can leave without hunting for a key.
Closers, hinges and seals: the parts that wear first
A fire door that does not shut is no fire door. The closer must pull the leaf shut every time, against the draught in the corridor and the weight of the leaf, and no fire door takes less than EN 3 to BS EN 1154, with the power size chosen for the leaf that is fitted. Our fire door closers guide covers the sizes and the fitting.
Hinges to BS EN 1935 are proved by cycles and by load, with grade 13 carrying 120 kg and grade 14 carrying 160 kg, each through 200,000 cycles, so the hinge should be chosen for the weight of the leaf it carries.
The seal round the leaf swells when the heat reaches it, closing the gap at around 200 to 250 degrees, and the gap itself must stay at 4 mm, because a wider gap lets fire and smoke past whatever the rating on the leaf says. A seal that has come away or been painted over leaves the gap open, so check the seals first on every round.
Smoke on the escape route: FD30S and the seal that must hold
Smoke kills before fire reaches the corridor, so the doors on the escape route need a smoke seal beside the fire seal. A door on a smoke path takes FD30S, with the seal proved to BS EN 1634-3, to Sa for smoke at room temperature and S200 for smoke at 200 degrees Celsius.
Order the smoke seal with the door, not after it, because a door fitted without one holds fire back and lets smoke through, and the escape route fills with smoke while the fire is still behind the leaf. The duties of a door on a smoke path are covered in our smoke control doors guide, and the commercial buildings fire door regulations guide sets out the periods for the shared parts of a building.
Hold-open devices keep a door open during the day and let it shut when the alarm sounds. BS EN 1155 covers the hold-open device, and a door held open by a wedge or a hook has no hold-open device at all, so the wedge belongs in the bin and the device belongs on the order. The fire door inspection checklist names what each round should look for.
A flat entrance door in a shared house is opened and shut twenty times a day, by people coming home, going out, carrying bags, holding the door for a neighbour, and letting it swing shut behind them. No other fire door in the building works that hard, and the wear shows in the parts that move every time: the latch that catches, the closer that pulls, and the seal that is rubbed each time the door shuts. The door does not fail in a single day. It wears a little with every use until one morning it stops latching and stands ajar.
Daily use wears the latch, the closer and the seal first
The latch wears first because it works hardest. Each shutting drives it into the keep and back out again, and the edge rounds a fraction with every year of use. A latch that has rounded no longer catches cleanly, so the door looks shut and springs open at a touch, and the escape route behind it is open to smoke.
The closer wears next. It is pulled open and let go all day, and the spring inside loses a little of its pull each month. A closer that has weakened still moves the door, but it stops short of the latch, and the door stands ajar by the width of a finger. Fire and security sit on one door here, and the flat entrance doors guide treats them together, so the lock is checked on the same visit as the closer.
The seal is rubbed every time the door shuts. It thins where the door meets the frame, and the thin patch lets smoke through while the rest of the seal still holds. An FD30S door needs its seal whole round the frame, and the smoke control doors guide deals with doors on a smoke path.
The flat entrance door stops latching when the latch no longer catches
It stops latching because the parts that catch it have worn past the point where they meet. The latch has rounded, the closer has weakened, and the door has dropped a fraction on its hinges, so the latch and the keep no longer line up. Any one of those on its own would still let the door shut, and the three together leave it standing open.
A building with the same corridor risk on every floor is walked the same way throughout, and the student accommodation regulations guide covers buildings of that kind, while the security door locks guide lists the lock sets that stay proved when the latch is changed.
Both rounds work from one list, and the fire door inspection checklist names what the round looks for, so a door that stops latching is put on the round sheet in the same words as a door found standing open on the monthly walk.
| Part | Daily wear | Sign it has worn |
|---|---|---|
| Latch | Twenty shuttings a day | Door no longer catches |
| Closer | Pulled shut all day | Door stands ajar |
| Seal | Rubbed each time the door shuts | Smoke path opens at the edge |
Send the latch, the closer and the seal together, and the security door enquiry checklist asks that every flat entrance door on it carry its parts and its date.
Kitchens, bathrooms and the rooms that share a corridor
A kitchen in an HMO carries the highest fire load in the building, and the door between the kitchen and the corridor takes FD60 where the wall is a compartment wall. The door must shut against the cooking smells and the steam as well as against fire, so the closer and the seals earn their keep every day, not only in a fire. The hotel fire doors guide works through the same bedroom-corridor risk for sleeping guests, and the plant room fire doors guide covers the doors on the plant rooms that feed the building.
Bathrooms and laundry rooms share a corridor with the bedrooms, and the doors on them take the period the fire load behind them asks for. A laundry room full of dryers and linen holds more risk than a bathroom, so the period follows the room, not the floor.
Communal rooms, a lounge or a study that several households share, need doors that hold the room off from the corridor while letting people move freely through the day. A door that is wedged open to keep the room friendly is a door that has stopped working, so the closer, not the wedge, is what keeps the room open and safe.
Access, keys and the lock that keeps the wrong hands out
An HMO holds people who do not know each other, so the locks must keep strangers out of the bedrooms while letting every resident out in a fire. A keyed cylinder outside and a thumb turn inside does both, and the thumb turn needs no key, so the person inside can leave in the dark without hunting for one.
Keys multiply in an HMO, and every key that leaves with a tenant is a key in the wrong hands. The cylinder should be changed when a tenant leaves, and the record should name the door, the cylinder and the date it was changed, so the next manager can see who holds a key and who does not.
For the shared front door, a card or a fob suits the residents, and a code that changes when staff leave suits the trades, because a code costs nothing to change and a lost fob costs a new one. The front door should release on alarm so no one is held inside when the alarm sounds.
A tenant leaves, and the property stands empty for a few days before the next tenant arrives. Those days are the changeover, and the changeover is the round that walks every door in the property again, because the doors have lived with one household and must be ready for the next. Nothing in the property is taken on trust during those days, because the next tenant will trust every door from the first night.
Between one tenant and the next, every door is walked again
The changeover round starts at the flat entrance door and ends at the stair core, stopping at every bedroom door in between. Each leaf is opened and let go, the closer is watched to the latch, and the seals are felt for the hardening that age brings.
A door that was wedged open by the last tenant has stopped working, so the wedge goes in the bin and the hold-open device is tested in its place. The device releases the leaf when the alarm sounds, and only a device proved to BS EN 1155 may hold a fire door open.
Bedroom doors take the closest look, because the person behind one is asleep when the alarm sounds. A leaf that will not shut on its own is written down before the round moves on, and the door is left shut until the closer is fixed.
The flat entrance door carries fire and security on one leaf, and the flat entrance doors guide puts both proofs side by side, so the changeover round checks the lock as well as the closer.
A building where the same shared corridor risk runs through every floor takes the same round, and the student accommodation regulations guide covers that building, while the smoke control doors guide sets out what a door on a smoke path must do.
The cylinder changes hands with the keys, and the record notes the date
A new tenant should never inherit the keys of the last one. The cylinder is changed on the changeover, the new keys are counted out to the new tenant, and the record names the door, the date and the person who holds each key.
A thumb turn on the inside lets the person in the flat leave without hunting for a key, and the security door locks guide sets out the sets that keep the lock proved while the cylinder changes.
Both rounds read from the same list, and the fire door inspection checklist sets out what the changeover round looks for, so a fault found between tenants is written down the same way as a fault found on the monthly walk.
| Changeover job | What is checked | What is changed |
|---|---|---|
| Flat entrance door | Lock, closer, seals | Cylinder and keys |
| Bedroom door | Closer, latch, gap | Seal where it has hardened |
| Stair core door | Seals, gap, closer | Hold-open device where it fails |
The changeover list goes to the security door enquiry checklist before the next tenant arrives, so every door on it carries its cylinder, its date and its keys.
The HMO order: one schedule for the whole property
Write the enquiry as one schedule with a line for every door in the property, and put the position, the fire period, the smoke seal, the forced entry rating and the hardware on each line, so the door that arrives is the door that was proved.
Put the quotes side by side and check each line, because the quote that leaves a seal or a closer off the list is not cheaper, only shorter, and the missing line is paid for later. The grades and the parts behind a working fire door are covered in our fire door hardware guide, and the security door cost factors guide works through what each step up the scale adds to the build. The fire ratings page sets out the periods and the letters, and our fire rated glazed doors guide and fire rated sliding doors guide cover the glazed and sliding leaves that share a corridor.
| Position | Door | Rating | What to check |
|---|---|---|---|
| Bedroom door | Fire door | FD30 | Closer, seals, latch |
| Flat entrance door | Fire and security door | FD30 + B3 | Lock, hinges, closer |
| Stair core door | Fire door | FD60 | Seals, gaps, closer |
| Kitchen door | Fire door | FD60 | Seals, closer, latch |
| Corridor door | Fire door with smoke seal | FD30S | Seals, gaps, hold-open |
An HMO holds several households behind shared corridors, so the bedroom doors, the flat entrance doors and the stair doors must all sit on the same schedule.
What fire rating do HMO bedroom doors need?
Most bedroom doors take FD30, and a door on a compartment wall or a high-risk room takes FD60, with the period set by the fire load behind the door.
Do HMO flat entrance doors need a security rating?
Yes, where the door guards a flat from the shared corridor. Fire is proved to EN 1634-1 and forced entry to LPS 1175 or PAS 24, and each proof must name the door that will be fitted.
What is FD30S on an HMO door?
Thirty minutes of fire resistance with a smoke seal proved to BS EN 1634-3, to Sa for smoke at room temperature and S200 for smoke at 200 degrees Celsius.
Who checks HMO fire doors?
The person responsible for the property, on the routine the fire risk assessment sets. Each record names the door, the fault, the repair and the date it was fixed.
Can an HMO fire door be held open?
Only by a hold-open device proved to BS EN 1155, which releases the door when the alarm sounds. A wedge or a hook is not a hold-open device.