HMO Fire Doors

HMO fire door rules: FD30 and FD60 bedroom doors, flat entrance doors, closers, hinges, seals, smoke control and one schedule for the whole property.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed across the UK
Prefer to talk?+44 7352 267239

Get a free project quote

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

A house in multiple occupation holds several households under one roof, and the doors between them carry the fire rating for the whole building. Each bedroom door, each flat entrance door and each door on the stair core must hold fire and smoke long enough for everyone inside to reach the street, and a door that fails in one room puts every other room at risk.

The risk in an HMO sits in the rooms people sleep in and the corridors they share. A fire that starts in one bedroom meets the corridor through the bedroom door, and a corridor full of smoke stops everyone behind it from leaving, so the doors on that route matter more than any other part of the building.

Flat entrance doors carry a different job from bedroom doors, and our flat entrance doors guide works through the two proofs one leaf must carry, while the student accommodation fire door regulations guide covers a building where the same shared-corridor risk runs through every floor.

  • FD30 / FD60Fire resistance periods tested to EN 1634-1
  • BS EN 1634-3 Sa / S200Smoke leakage classes
  • 4 mmMaximum gap round a fire door leaf
  • LPS 2081 SRA / SRBOne and three minutes against a quiet attack

Bedrooms, corridors and stair cores: where an HMO puts its fire doors

A bedroom door in an HMO is the line between a sleeping person and the corridor outside. It must hold fire back for its period and keep smoke off the route, and it must shut every time it is opened, because a bedroom door left open is a corridor full of smoke.

The stair core is the way out for everyone above the ground floor, and the doors that open onto it carry the same duty as the stair itself. A door on the stair that fails lets fire into the one route nobody can do without, so the stair doors take the period the fire load behind them asks for.

Corridor doors divide the route into parts, so a fire in one part meets a door before it meets the next. Cross-corridor doors hold smoke back while people move past them, and a door on the escape route must open freely from the inside, with no key, no card and no code between the person and the street.

FD30 and FD60 in an HMO: the period each door carries

Thirty minutes is the period most bedroom doors carry, and sixty minutes is the period for the doors that guard a compartment wall or a room with a heavier fire load. The number names the minutes the door held, and the letter names what the furnace measured: E for integrity, EW for integrity with limited radiation and EI for integrity with insulation.

A door proved to EI 60 weighs more than a door proved to E 30, and the hinges, the closer and the fixings must be chosen for the leaf that arrives, not for the leaf the drawing shows. A longer period than the room needs only makes the leaf heavier, so the order should name the period the fire load asks for and nothing more. Steel and timber leaves behave differently in a fire, and the choice is worked through in our steel versus timber fire doors guide.

Proof belongs to the fitted doorset, not to the leaf on its own. Ask for the test report on the door, the frame and the hardware as one assembly, and check that the frame on site matches the frame in the report, because a leaf in the wrong frame carries no proof at all. Our fire rated steel doors guide covers the steel leaves that carry the higher periods.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

The flat entrance door: fire and security on one leaf

A flat entrance door in an HMO must do two jobs at once. It must hold fire back for its period, and it must resist a forced entry, because the door between a flat and the shared corridor is the one a thief tries first and the one a fire meets first.

The forced entry proof comes from LPS 1175, with B3 holding three minutes against category B tools, C5 holding five minutes against category C tools and D10 holding ten minutes against category D tools, all under Issue 8.2, dated September 2024. The ratings in full are on our LPS 1175 page.

A flat that empties at night faces a quiet attack, and LPS 2081 answers it: SRA for one minute and SRB for three minutes against an attack that tries not to be heard. The rating belongs on the schedule beside the fire period, because a door that holds fire and opens to a quiet hand has failed half its job.

For the lock, ask for a TS 007 3-star set, a 1-star cylinder with a 2-star handle or escutcheon, and fit a thumb turn on the inside so the person in the flat can leave without hunting for a key.

Closers, hinges and seals: the parts that wear first

A fire door that does not shut is no fire door. The closer must pull the leaf shut every time, against the draught in the corridor and the weight of the leaf, and no fire door takes less than EN 3 to BS EN 1154, with the power size chosen for the leaf that is fitted. Our fire door closers guide covers the sizes and the fitting.

Hinges to BS EN 1935 are proved by cycles and by load, with grade 13 carrying 120 kg and grade 14 carrying 160 kg, each through 200,000 cycles, so the hinge should be chosen for the weight of the leaf it carries.

The seal round the leaf swells when the heat reaches it, closing the gap at around 200 to 250 degrees, and the gap itself must stay at 4 mm, because a wider gap lets fire and smoke past whatever the rating on the leaf says. A seal that has come away or been painted over leaves the gap open, so check the seals first on every round.

Smoke on the escape route: FD30S and the seal that must hold

Smoke kills before fire reaches the corridor, so the doors on the escape route need a smoke seal beside the fire seal. A door on a smoke path takes FD30S, with the seal proved to BS EN 1634-3, to Sa for smoke at room temperature and S200 for smoke at 200 degrees Celsius.

Order the smoke seal with the door, not after it, because a door fitted without one holds fire back and lets smoke through, and the escape route fills with smoke while the fire is still behind the leaf. The duties of a door on a smoke path are covered in our smoke control doors guide, and the commercial buildings fire door regulations guide sets out the periods for the shared parts of a building.

Hold-open devices keep a door open during the day and let it shut when the alarm sounds. BS EN 1155 covers the hold-open device, and a door held open by a wedge or a hook has no hold-open device at all, so the wedge belongs in the bin and the device belongs on the order. The fire door inspection checklist names what each round should look for.

A flat entrance door in a shared house is opened and shut twenty times a day, by people coming home, going out, carrying bags, holding the door for a neighbour, and letting it swing shut behind them. No other fire door in the building works that hard, and the wear shows in the parts that move every time: the latch that catches, the closer that pulls, and the seal that is rubbed each time the door shuts. The door does not fail in a single day. It wears a little with every use until one morning it stops latching and stands ajar.

Daily use wears the latch, the closer and the seal first

The latch wears first because it works hardest. Each shutting drives it into the keep and back out again, and the edge rounds a fraction with every year of use. A latch that has rounded no longer catches cleanly, so the door looks shut and springs open at a touch, and the escape route behind it is open to smoke.

The closer wears next. It is pulled open and let go all day, and the spring inside loses a little of its pull each month. A closer that has weakened still moves the door, but it stops short of the latch, and the door stands ajar by the width of a finger. Fire and security sit on one door here, and the flat entrance doors guide treats them together, so the lock is checked on the same visit as the closer.

The seal is rubbed every time the door shuts. It thins where the door meets the frame, and the thin patch lets smoke through while the rest of the seal still holds. An FD30S door needs its seal whole round the frame, and the smoke control doors guide deals with doors on a smoke path.

The flat entrance door stops latching when the latch no longer catches

It stops latching because the parts that catch it have worn past the point where they meet. The latch has rounded, the closer has weakened, and the door has dropped a fraction on its hinges, so the latch and the keep no longer line up. Any one of those on its own would still let the door shut, and the three together leave it standing open.

A building with the same corridor risk on every floor is walked the same way throughout, and the student accommodation regulations guide covers buildings of that kind, while the security door locks guide lists the lock sets that stay proved when the latch is changed.

Both rounds work from one list, and the fire door inspection checklist names what the round looks for, so a door that stops latching is put on the round sheet in the same words as a door found standing open on the monthly walk.

Part Daily wear Sign it has worn
Latch Twenty shuttings a day Door no longer catches
Closer Pulled shut all day Door stands ajar
Seal Rubbed each time the door shuts Smoke path opens at the edge

Send the latch, the closer and the seal together, and the security door enquiry checklist asks that every flat entrance door on it carry its parts and its date.

Kitchens, bathrooms and the rooms that share a corridor

A kitchen in an HMO carries the highest fire load in the building, and the door between the kitchen and the corridor takes FD60 where the wall is a compartment wall. The door must shut against the cooking smells and the steam as well as against fire, so the closer and the seals earn their keep every day, not only in a fire. The hotel fire doors guide works through the same bedroom-corridor risk for sleeping guests, and the plant room fire doors guide covers the doors on the plant rooms that feed the building.

Bathrooms and laundry rooms share a corridor with the bedrooms, and the doors on them take the period the fire load behind them asks for. A laundry room full of dryers and linen holds more risk than a bathroom, so the period follows the room, not the floor.

Communal rooms, a lounge or a study that several households share, need doors that hold the room off from the corridor while letting people move freely through the day. A door that is wedged open to keep the room friendly is a door that has stopped working, so the closer, not the wedge, is what keeps the room open and safe.

Access, keys and the lock that keeps the wrong hands out

An HMO holds people who do not know each other, so the locks must keep strangers out of the bedrooms while letting every resident out in a fire. A keyed cylinder outside and a thumb turn inside does both, and the thumb turn needs no key, so the person inside can leave in the dark without hunting for one.

Keys multiply in an HMO, and every key that leaves with a tenant is a key in the wrong hands. The cylinder should be changed when a tenant leaves, and the record should name the door, the cylinder and the date it was changed, so the next manager can see who holds a key and who does not.

For the shared front door, a card or a fob suits the residents, and a code that changes when staff leave suits the trades, because a code costs nothing to change and a lost fob costs a new one. The front door should release on alarm so no one is held inside when the alarm sounds.

A tenant leaves, and the property stands empty for a few days before the next tenant arrives. Those days are the changeover, and the changeover is the round that walks every door in the property again, because the doors have lived with one household and must be ready for the next. Nothing in the property is taken on trust during those days, because the next tenant will trust every door from the first night.

Between one tenant and the next, every door is walked again

The changeover round starts at the flat entrance door and ends at the stair core, stopping at every bedroom door in between. Each leaf is opened and let go, the closer is watched to the latch, and the seals are felt for the hardening that age brings.

A door that was wedged open by the last tenant has stopped working, so the wedge goes in the bin and the hold-open device is tested in its place. The device releases the leaf when the alarm sounds, and only a device proved to BS EN 1155 may hold a fire door open.

Bedroom doors take the closest look, because the person behind one is asleep when the alarm sounds. A leaf that will not shut on its own is written down before the round moves on, and the door is left shut until the closer is fixed.

The flat entrance door carries fire and security on one leaf, and the flat entrance doors guide puts both proofs side by side, so the changeover round checks the lock as well as the closer.

A building where the same shared corridor risk runs through every floor takes the same round, and the student accommodation regulations guide covers that building, while the smoke control doors guide sets out what a door on a smoke path must do.

The cylinder changes hands with the keys, and the record notes the date

A new tenant should never inherit the keys of the last one. The cylinder is changed on the changeover, the new keys are counted out to the new tenant, and the record names the door, the date and the person who holds each key.

A thumb turn on the inside lets the person in the flat leave without hunting for a key, and the security door locks guide sets out the sets that keep the lock proved while the cylinder changes.

Both rounds read from the same list, and the fire door inspection checklist sets out what the changeover round looks for, so a fault found between tenants is written down the same way as a fault found on the monthly walk.

Changeover job What is checked What is changed
Flat entrance door Lock, closer, seals Cylinder and keys
Bedroom door Closer, latch, gap Seal where it has hardened
Stair core door Seals, gap, closer Hold-open device where it fails

The changeover list goes to the security door enquiry checklist before the next tenant arrives, so every door on it carries its cylinder, its date and its keys.

The HMO order: one schedule for the whole property

Write the enquiry as one schedule with a line for every door in the property, and put the position, the fire period, the smoke seal, the forced entry rating and the hardware on each line, so the door that arrives is the door that was proved.

Put the quotes side by side and check each line, because the quote that leaves a seal or a closer off the list is not cheaper, only shorter, and the missing line is paid for later. The grades and the parts behind a working fire door are covered in our fire door hardware guide, and the security door cost factors guide works through what each step up the scale adds to the build. The fire ratings page sets out the periods and the letters, and our fire rated glazed doors guide and fire rated sliding doors guide cover the glazed and sliding leaves that share a corridor.

Position Door Rating What to check
Bedroom door Fire door FD30 Closer, seals, latch
Flat entrance door Fire and security door FD30 + B3 Lock, hinges, closer
Stair core door Fire door FD60 Seals, gaps, closer
Kitchen door Fire door FD60 Seals, closer, latch
Corridor door Fire door with smoke seal FD30S Seals, gaps, hold-open

An HMO holds several households behind shared corridors, so the bedroom doors, the flat entrance doors and the stair doors must all sit on the same schedule.

What fire rating do HMO bedroom doors need?

Most bedroom doors take FD30, and a door on a compartment wall or a high-risk room takes FD60, with the period set by the fire load behind the door.

Do HMO flat entrance doors need a security rating?

Yes, where the door guards a flat from the shared corridor. Fire is proved to EN 1634-1 and forced entry to LPS 1175 or PAS 24, and each proof must name the door that will be fitted.

What is FD30S on an HMO door?

Thirty minutes of fire resistance with a smoke seal proved to BS EN 1634-3, to Sa for smoke at room temperature and S200 for smoke at 200 degrees Celsius.

Who checks HMO fire doors?

The person responsible for the property, on the routine the fire risk assessment sets. Each record names the door, the fault, the repair and the date it was fixed.

Can an HMO fire door be held open?

Only by a hold-open device proved to BS EN 1155, which releases the door when the alarm sounds. A wedge or a hook is not a hold-open device.

Specifying fire doors for an HMO?Send the door schedule and the property plan for a tested door quotation.
Get a free quote

Related

More in guides for specifiers

10 mistakes when specifying certified security doors 10 steps to specify an LPS 1175 door Acceptance and Snagging of a Security Door or Barrier Job Access Control Doors Acoustic Doors: Ratings and Specification After a Forced Entry Attempt: Checking a Security Door Airport Security Doors Anti-Ligature Doors for Mental Health Wards Anti-Ram Bollards Anti-ram gates and barriers: protecting vehicle entrances Arcade Security Doors Explained Automatic Doors Automatic Gates Cost Factors Automatic Vehicle Barriers Ballistic Panels Bank Security Doors Bingo Hall Security Doors Explained Blast doors: glazed vs solid and how they are rated Blast protection window film: what it does and what it cannot do Blast resistant windows: what drives the cost and how to specify them Bollard Cost Factors Explained Bollard regulations in the UK: spacing, height and depth Bookmaker Security Doors Explained Builders Merchant Security Doors Bullet Resistant Glass Cost Factors Bullet resistant glass ratings explained: BR1 to BR7 and SG classes Bullet resistant vs bulletproof glass: what the difference means Buying Security Doors and HVM Through Public Frameworks Car Park Security Doors Explained Car Showroom Security Doors Casino Security Doors Explained CDM 2015 Duties When Security Doors, Shutters or HVM Are Installed Cinema Security Doors Cleanroom Doors Cold Store Doors College Security Doors Commissioning, Handover and the O&M Manual for Security Doors and HVM Communal entrance doors for flats: Secured by Design and what to specify Community Centre Security Doors Control Room Doors Court Security Doors Crash Rated Fences and HVM Fencing Explained Data centre physical security: doors, glazing, HVM and shielding by zone Dental Practice Security Doors Depot Security Doors Explained Door Entry Systems Due Diligence When Selecting Vehicle Security Barriers Emergency Exit Doors EMP Shielding Cost Factors Explained Exhibition Centre Fire Door Rules Exhibition Centre Security Doors Factory Security Doors Faraday cage vs RF shielded room: what a business needs FB4 vs FB6 vs FB7: how to choose a ballistic rating Fire and security doors: how dual certification works Fire Compartmentation Fire Curtains Fire Door Certification Fire Door Closers Explained Fire Door Cost Factors Fire Door Duties of the Accountable Person Fire Door Gaps Fire Door Hardware Explained Fire door inspection checklist for steel and timber doors Fire Door Maintenance Fire Door Regulations Care Homes Fire Door Regulations for A and E Departments Fire Door Regulations for Airports Explained Fire Door Regulations for Bowls Clubs Fire door regulations for commercial buildings in the UK Fire Door Regulations for Dialysis Centres Fire Door Regulations for Hockey Clubs Fire Door Regulations for Hospitals Explained Fire Door Regulations for Offices Explained Fire Door Regulations for Operating Theatres Fire Door Regulations for Retail Explained Fire Door Regulations for Schools Explained Fire Door Regulations for Snooker Clubs Fire Door Regulations for Stadiums Fire Door Regulations for Student Accommodation Fire Door Regulations for Warehouses Fire Door Regulations Leisure Centres Fire Door Regulations Restaurants Fire Door Remediation Programme for Housing Providers Fire Door Rules for Badminton Clubs Fire Door Rules for Bingo Halls Fire Door Rules for Bookmakers Fire Door Rules for Bowling Alleys Fire Door Rules for Car Parks Fire Door Rules for Car Showrooms Fire Door Rules for Cinemas Fire Door Rules for Climbing Centres Fire Door Rules for Colleges Fire Door Rules for Community Centres Fire Door Rules for Cricket Clubs Fire Door Rules for Dental Practices Fire Door Rules for Depots Explained Fire Door Rules for Golf Clubs Fire Door Rules for GP Surgeries Fire Door Rules for Gyms Explained Fire Door Rules for Ice Rinks Fire Door Rules for Maternity Units Fire Door Rules for Mental Health Units Fire Door Rules for Museums Fire Door Rules for Oncology Units Fire Door Rules for Opticians Fire Door Rules for Pawnbrokers Fire Door Rules for Petrol Stations Fire Door Rules for Pharmacies Fire Door Rules for Ports Fire Door Rules for Post Offices Fire Door Rules for Prisons Fire Door Rules for Rehabilitation Centres Fire Door Rules for Self Storage Fire Door Rules for Shopping Centres Fire Door Rules for Squash Clubs Fire Door Rules for Supermarkets Fire Door Rules for Swimming Pools Fire Door Rules for Tennis Clubs Fire Door Rules for Theatres Fire Door Rules for UK Arcades Fire Door Rules for UK Casinos Fire Door Rules for UK Hospices Fire Door Rules for Walk-in Centres Fire Door Signage Fire Door Vision Panels Fire Doors and Gateway 2 in Higher-Risk Buildings Fire Rated Glass Cost Explained Fire Rated Sliding Doors Explained Fire Rated Windows Cost Factors Fire Rated Windows Explained Fire Safety Enforcement Notices and Fire Doors: What the Responsible Person Must Do Flat Entrance Doors: PAS 24 and Fire Rated Forced Entry vs Ballistic vs Blast: Which Rating a Site Needs Garage Security Doors Explained Gate Automation Explained Golden Thread Records for Fire Doors GP Surgery Security Doors Explained Gym Security Doors Explained High Speed Doors Hospice Security Doors Explained Hospital Security Doors: Wards, A&E, Plant Hospital Security Gates Hotel Fire Doors Hotel Security Doors How to choose HVM bollards: fixed, shallow mount, removable and automatic How to keep an LPS 1175 door rating valid after installation How to Specify Fire Doors in a Housing Tender How to specify security doors: a checklist for architects How to Verify a Secured by Design Listing How to Verify an LPS 1175 Certificate on Red Book Live How to Write an Operational Requirement for Physical Security HVM planters and street furniture: protection that blends in In-Service Care of Vehicle Security Barriers Installation Handover: LPS 1175 Doors and PAS 68 Barriers Intumescent Seals ISO 16933 explained: EXV and SB classes and hazard ratings ISO 22343 vehicle security barriers explained Keeping a Dual-Certified Fire and Security Door Valid in Service Laboratory Security Doors Layered Security for a Site: Deter, Detect, Delay, Mitigate, Respond Lead Times and Programme Risks for LPS 1175 Doors Leisure Centre Security Doors Library Security Doors Listed Building Fire Doors Loading Bay Doors Explained Lockdown and Access Control Hardware on an LPS 1175 Door LPS 1175 Gates and Grilles Explained LPS 1175 Issue 8 explained: from SR1 to SR8 to A1 to H20 LPS 1175 Roller Shutters LPS 1175 vs ASTM F2781 and Other US Ratings Explained LPS 1175 vs EN 1627: how UK and European burglar resistance ratings compare LPS 1175 vs PAS 24: which security standard does your door need? LPS 1175 Windows and Walling Explained Martyn’s Law and Places of Worship: What a Buyer Checks for Doors and Entry Control Martyn’s Law Enhanced Tier: Physical Measures and the Specifier Brief Martyn’s Law Standard Tier: Procedures, Doors and Shutters Martyn’s Law Timeline and the SIA Regulator Martyn’s Law: what premises must do and which physical measures to consider Master Key Systems MRI and RF shielded rooms: how they work and what to specify Museum Security Doors NPSA Catalogue of Security Equipment (CSE) Explained NPSA Forced Entry and Blast Guidance for Government Sites NPSA Guidance on Lockdown and Marauding Attack: What It Asks of Doors and Entrances Office Security Doors Optician Security Doors Explained Panic Hardware PAS 24 requirements for doors and windows explained PAS 68 Bollard Foundations Explained PAS 68 bollards: ratings, spacing and cost factors PAS 68 vs IWA 14 vs ISO 22343: hostile vehicle mitigation standards explained Pawnbroker Security Doors Explained Pedestrian Gates Petrol Station Security Doors Pharmacy Security Doors Planning Permission for Security Shutters, Gates and Bollards on Commercial Premises Plant room doors: fire, security and ventilation requirements Plant Room Fire Doors Port Security Doors Post Office Security Doors Explained Powder coating vs galvanising vs paint for steel Preliminary Market Engagement for Security Doors and HVM Prison Security Doors Programming a Security Door and Barrier Package on a Live Site Public-Sector Tender Response Checklist for Security Door and HVM Supply Reading a PAS 24 and SBD Door Test Report Regulation 38 Fire Safety Information at Handover for Fire-Rated Security Doorsets Replacing Security Doors in an Occupied Building Restaurant Security Doors Retail Security Doors Revolving Doors RF shielding standards and how shielded rooms are tested Rising Bollard Cost Factors Road Blocker Cost Factors Explained Road Blockers Explained Roller Shutter Cost Factors: What Drives the Price Roller shutter regulations in the UK: safety and maintenance Safe room and panic room doors: specification basics Safety Duties for Powered Doors, Gates and Barriers on Commercial Sites School Security Doors Sectional Doors Secured by Design explained: is it mandatory for doors? Secured by Design vs NPSA vs LPCB: Which One You Need Security Door Locks Security Door Maintenance Checklist Security Doors and Access for Everyone: What Approved Document M Asks Security Doors for A and E Departments Security Doors for Badminton Clubs Security Doors for Bowling Alleys Security Doors for Bowls Clubs Security Doors for Climbing Centres Security Doors for Cricket Clubs Security Doors for Dialysis Centres Security Doors for Golf Clubs Security Doors for Hockey Clubs Security Doors for Ice Rinks Security Doors for Maternity Units Security Doors for Mental Health Units Security Doors for Oncology Units Security Doors for Operating Theatres Security Doors for Rehabilitation Centres Security Doors for Snooker Clubs Security Doors for Squash Clubs Security Doors for Swimming Pools Security Doors for Tennis Clubs Security Doors for Walk-in Centres Security Doors West Midlands Explained Security Fencing Security Gates Cost Factors Explained Security shutters vs high performance roller doors Security shutters vs retractable grilles: which suits retail and commercial openings? Security Turnstiles Explained Security Window Film Security Windows for Schools Explained Self Storage Security Doors Server Room Doors Explained Shopping Centre Security Doors Smoke Control Doors Explained Smoke Curtains Specification Mistakes When Mixing LPS 1175, PAS 24 and SBD in One Tender SR2 vs SR3 vs SR4 security doors: choosing the right LPS 1175 level Stadium Security Doors Steel Door Frames Steel vs aluminium security doors: strength, ratings and looks Steel vs timber fire doors: which suits your building? Student Accommodation Security Doors Substation doors: security, ventilation and specification Supermarket Security Doors Telescopic Bollards Tender Evaluation Criteria and Scoring for Security Doors and HVM The Scope of a Maintenance Contract for Security Doors and Barriers Theatre Security Doors Thermal and Weather Performance of External Security Doorsets Thermally broken steel security doors: U-values and certification Traffic Calming as Hostile Vehicle Mitigation Transport hub security requirements Turnstile Cost Factors Explained Turnstile vs speed gate vs security portal: choosing entrance control Types of security doors for commercial buildings University Security Doors Explained Vehicle Dynamics Assessment: What It Tells the Buyer Before a Barrier Is Specified Warehouse Security Doors Explained Warehouse Security Gates Warranty, Defects Liability and Guarantees for Security Doors and Barriers What affects the cost of a bullet resistant door What affects the cost of a high-security door in the UK Window Security Bars View all →