Fire Door Rules for Rehabilitation Centres
A rehabilitation centre holds residents through long stays with medicines stored on site, so each door takes the fire period its room demands, FD30 or FD60.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A rehabilitation centre holds residents through long stays, and the fire rules for the building follow the rooms behind each leaf. The bedroom wing holds the rooms where residents sleep, the treatment rooms hold the therapy and the equipment, and the medicines store, the staff office and the plant room sit behind leaves the residents never pass. Residents move slowly, and some need help to leave, so the leaves on the way out matter as much as the leaves that hold flame back.
EN 1634-1 gives the minutes on a centre leaf, testing the leaf against fire and counting how long it holds. FD30 means thirty minutes and FD60 means sixty, and the letter with the minutes says what stayed out: E for flames alone, EW for flames and part of the heat, and EI for flames and heat together.
A rehabilitation centre is not a hospice, because the residents here are working toward going home, and it is not a care home, because treatment rooms sit beside the bedrooms. The ward is not a locked ward, so residents move freely through the day and the fire rules follow the rooms. The fire door regulations care homes guide names the fire rules for a home where residents live for years, and the fire door regulations hospitals guide names the rooms a hospital keeps behind its public floor.
- FD30 / FD60Fire periods to EN 1634-1
- Bedroom wingWhere residents leave from
- Sa / S200Smoke ratings to BS EN 1634-3
- One listEvery centre door named
Seven rooms in a rehabilitation centre: the period each leaf takes
Seven rooms make up the centre order, and the period follows what each room holds. The residents come in through the entrance, and the bedroom wing holds the rooms where they sleep through their stay. The medicines store keeps the medicines given through the day, the treatment rooms keep the therapy and the equipment, the staff office keeps the keys and the records, and the plant room keeps the building running.
The medicines store, the treatment rooms, the staff office and the plant room take FD60, because the medicines, the equipment, the records and the boards behind those leaves ask for sixty minutes before flame reaches them. The entrance, reception and the bedroom wing route take FD30, because the residents on that route can reach the street in less than thirty minutes.
The order gives every opening its own line, naming the leaf and the period beside it, and the table below puts the seven rooms beside their periods and grades, so the fitter checks each leaf against its own line as it is hung.
| Room | Period | Grade | What to check |
|---|---|---|---|
| Entrance | FD30 | B3 | Leaf, glass, closer |
| Reception | FD30 | B3 | Leaf, glass, closer |
| Bedroom wing | FD30 | B3 | Leaf, glass, closer |
| Medicines store | FD60 | D10 | Leaf, lock, seals |
| Treatment rooms | FD60 | C5 | Leaf, lock, seals |
| Staff office | FD60 | C5 | Leaf, lock, seals |
| Plant room | FD60 | C5 | Leaf, lock, seals |
What FD30 and FD60 hold back among the treatment rooms
A leaf earns its minutes as part of a doorset, leaf, frame, fixings and lock proved as one, and the report states the period that doorset holds. The order writes that period beside the leaf, so the leaf that arrives is the one the room asked for, and the fire door certification guide names what the report behind a period must hold.
One doorset can carry both proofs, fire minutes from EN 1634-1 and a forced entry grade from LPS 1175 Issue 8.2 of September 2024, in B3, C5 and D10, so a single report names both for the same leaf. The fire and security doors dual certification guide shows how the pair is proved on one leaf.
The letter beside the minutes matters as much as the minutes. E means the leaf stopped flame, EW means it stopped flame and part of the heat, and EI means it stopped flame and heat together, so the order names the letter with the minutes.
FD60 on the medicines store, treatment rooms, staff office and plant room
The medicines store leaf takes FD60 and stays shut whenever no one is working behind it, because the medicines behind it are what the residents are given through the day. Sixty minutes is the hold that room asks for, because flame reaching it takes medicines residents cannot do without.
Treatment room leaves take FD60 as well, because the therapy equipment and the notes behind them are what the centre runs on. A leaf left standing open through the day holds nothing back, so each leaf is shut when the last person leaves the room.
Keys, records and paperwork sit in the staff office, and boards and equipment that keep the lights and the heating running sit in the plant room, so both leaves take FD60 because what sits behind them feeds the whole centre. The plant room fire doors guide covers the plant room leaves in full, and the plant room door requirements guide names the doors that guard the plant.
The bedroom wing and the way out: FD30 on the escape route
FD30 sits on the bedroom wing leaf and on the entrance leaf, because the residents sleep in the wing and reach the street through the entrance. Thirty minutes is more than the residents need to leave, and the route to the street is short.
Where the route serves residents who move slowly, a push bar proved to BS EN 1125 sits on each leaf on the way out, and the bar spans at least 60 percent of the leaf width, so a resident who reaches the leaf in a crowd opens it with one push. The panic hardware guide sets out what the bar must do when residents push against the leaf, and the emergency exit doors guide covers the leaves on the way out.
A glazed panel in the reception leaf lets staff watch the residents without opening the leaf, and the pane is proved with the leaf round it, with the glass, the bead and the fixings named together in the report. The fire door vision panels guide names the panels a fire leaf may carry, and the steel vs timber fire doors guide sets the two leaf materials beside each other.
Smoke in the corridors: Sa and S200 beside the period
Residents leaving the bedroom wing meet smoke before they meet flame, so the leaves on the way out carry a smoke rating beside their fire period. BS EN 1634-3 gives the two ratings, Sa for smoke at room temperature and S200 for smoke at 200 degrees, and the smoke control doors guide works through how the route leaves keep the smoke back while residents move past them.
A leaf that must stay open through the day is held by a hold-open device proved to BS EN 1155, and the device lets the leaf go on its own the moment the alarm sounds. The fire compartmentation guide names how the leaves hold the line between one part of the centre and the next, and a chair wedged under a leaf gives it no period at all while it stands open.
Smoke spreads along a corridor faster than residents walk, so the leaves between the bedroom wing and the entrance matter most. A leaf that shuts on its own after each person through keeps the smoke on one side.
Closers, seals and gaps on rehabilitation centre doors: what the period rests on
The hour on an FD60 leaf rests on the closer shutting it, the seals meeting the frame and the gaps staying narrow, because flame passes through a leaf left ajar in seconds and through a wide gap soon after. BS EN 1154 sizes closer power from EN 1, for a leaf 750 mm wide and 20 kg, up to EN 7, for a leaf 1,600 mm wide and 160 kg, and a fire door closer takes at least EN 3.
When heat of 200 to 250 degrees reaches the frame, the seal swells in its groove until it closes the gap, so flame and hot gas cannot pass, and paint over the seal stops it swelling. The 4 mm gap round a hung leaf is checked with a gauge, and the monthly round shows whether any gap has grown past that figure. The intumescent seals guide covers fitting the seal, the fire door closers guide covers what the closer must do, and the fire door gaps guide covers measuring the gaps.
Grade 13 hinges proved to BS EN 1935 carry 120 kg through 200,000 cycles, and grade 14 hinges carry 160 kg through the same count, so the heavier leaf takes the heavier hinge. BS 8300 and Approved Document M put the opening force below 30 N through the first 30 degrees and below 22.5 N after them, so a resident can push the leaf open without help. The fire door signage guide names what each sign must say.
The hold-open device holds the wing door open while the ward works around it
A wing door in a rehabilitation centre stands open through the day, held by a device proved to BS EN 1155, so beds, trolleys and therapy equipment pass without a hand on the door. The device holds the door against its closer all day and lets go the moment the alarm sounds, and the closer then draws the door back to its frame without a hand on it. That release is proved by testing it, not by trusting it.
The test is weekly, one door at a time, so the ward keeps working round it. Staff trip the release, watch the door swing shut, and notes whether it met the frame or stopped short, because a device that sticks holds the door open after the alarm and opens the corridor to smoke. The wing door that fails the test is taken off hold-open until it is mended, and it is shut by hand in the meantime. The closer guide sets out the sizes a wing door takes and the pull each size gives when the release lets go.
Smoke reaches the corridor while residents are still finding the way out, so the wing doors carry a smoke rating with their fire period. BS EN 1634-3 gives two ratings: Sa, which holds smoke at room temperature, and S200, which holds it at 200 degrees, and either one works only where the seal touches the frame without a break. A seal that has dried and shrunk opens a break at the top corner, and the weekly test is the moment to see it. The smoke control guide shows how a wing door keeps smoke on one side while residents pass.
| Test step | What to watch | If it fails |
|---|---|---|
| Release | Device lets go at once | Door off hold-open until mended |
| Swing | Door meets the frame alone | Closer size checked and reset |
| Seal | Strip touches the frame throughout | Strip reseated before the next test |
| Record | Date beside the room name | Fault chased the same week |
Test the release every week and write the result beside the door
BS EN 1154 gives closer sizes from EN 1 to EN 7, and a fire door takes nothing below EN 3, so the size is fixed door by door and written on the order beside each room. A closer below its size cannot pull a heavy wing door shut once the device lets go. The test shows which fault is present, because a door that swings shut slowly points at the closer and a door that stops short points at the frame. The maintenance guide sets out the work that keeps a wing door shutting through the year.
Missed tests are the risk, because a device that has never been tripped can stick without anyone knowing. The rota names the day and the person, and the result is written beside the door. The inspection checklist sets out what the weekly walk should look for on each door, and the exit guide follows the wing doors from the bedrooms to the street.
The wing list goes to the enquiry checklist with each hold-open device, its test date and its closer size beside the room, so the door that stands open all day still shuts when the alarm sounds.
Getting slow-moving residents out: the way from the bedroom wing to the street
The alarm may sound while a resident who has never used the building sits in a treatment room, so the route to the street is signed at every turn. The route stays clear day and night, and the entrance leaf opens to one push from whoever reaches it first, with the supply on or off.
Martyns Law sorts a venue into a tier by how many people it holds, one tier for 200 to 799 people and a higher tier at 800 and above, with Royal Assent in April 2025 and the go-live expected in spring 2027. The Martyns Law guide for premises sets out what each tier asks for, and a centre that holds 200 or more people falls in a tier it covers.
Staff walk the route with new residents on arrival, so the way out is known before the alarm ever sounds. A resident who knows the route leaves faster, and one who has walked it once does not stop to look for the way when the alarm sounds.
Let the leaf wait until the last wheelchair has cleared the frame
A resident who walks with a frame, or rides in a wheelchair, crosses a doorway slowly, and the leaf has to wait for that crossing. If the leaf swings back too soon it meets the frame in the opening and shuts the route on the resident behind, so the closer is set slow, giving the last wheel time to clear the frame before the leaf moves. A wing leaf that has to stay open all day is held by a BS EN 1155 device, which releases the leaf without a hand on it when the alarm sounds.
One hand is all a resident with a frame can spare for the leaf, so the push it asks for stays low. BS 8300 and Approved Document M cap that push at 30 N for the opening 30 degrees, and at 22.5 N once the leaf has swung past them, so a resident moves the leaf without letting go of the frame. The panic hardware guide names the bar that opens the leaf for a resident at the front of a group.
On a route that serves more than 60 people, BS EN 1125 asks the bar to run across at least six tenths of the leaf, so a single push from the resident at the front opens it for everyone behind. New residents are shown the way out on arrival, walking it once with staff, so the route is familiar before the alarm ever sounds. The emergency exit guide follows the leaves from the bedroom wing to the street.
| Person | What the leaf must do | Check |
|---|---|---|
| Resident with a frame | Stay open for a slow pass | Closer set for a slow swing |
| Resident in a wheelchair | Open with one hand | Push below 30 N at first |
| Staff helping a resident | Shut behind the pair | Leaf meets the frame alone |
| Resident on the night round | Open to one push | Bar spans six tenths of leaf |
The leaf shuts on its own, but the resident still opens it with one hand
The closer has two jobs that pull against each other: it must draw the leaf shut after a slow pass, and it must leave the leaf light enough for one hand to open. BS EN 1154 sizes closers from EN 1 to EN 7, and EN 3 is the smallest size a fire leaf is given, so the size is fixed leaf by leaf and written on the order beside each door. The closer guide works through the sizes a wing leaf takes and the pull each size gives.
The way out is marked at every turn, because the alarm can sound while a resident sits in a treatment room having never walked the route. The signage guide names the signs that mark the way from the wing to the street, and the route is kept free of chairs and trolleys, so nothing stands where slow feet must go.
Wing leaves are shut behind the last resident out, and the closer is worked each time the wing empties, because a leaf that will not shut by itself holds no minutes. The maintenance guide lists the work that keeps a wing leaf shutting through the year, and the security door enquiry checklist asks for the wing leaf by leaf, with a closer size written beside every door.
The rehabilitation centre fire door order: every leaf, its period and its proof
The order gives every opening in the centre a line of its own, with the leaf, the period, the lock and the closer written beside it. A leaf named once for the whole centre leaves the fitter to guess, and a leaf in the wrong room holds flame for the wrong time.
The order is checked leaf by leaf before it is signed, because a closer ordered after the doorset arrives holds the job up, and a leaf with no line beside it cannot be checked when it arrives. What the order must hold is named in the how to specify security doors guide.
Once a month the centre manager walks the building with the door list and works each leaf in turn. A leaf that drags, a closer that leaves a leaf standing open and a seal painted over in a refit are written against their own doors the day they are found. The fire door inspection checklist names what to look for on each leaf, and the fire door maintenance guide names the work that keeps the leaves holding.
Put the period, the grade and the lock on one line for each leaf, and check the line against the room before the leaf is hung.
What period should a rehabilitation centre medicines store door carry?
FD60 to EN 1634-1, because the medicines store holds medicines, and an hour is the hold that room demands.
What period should a rehabilitation centre entrance door carry?
FD30 to EN 1634-1, because the entrance is the way out and the public route needs half an hour.
Can one leaf hold fire and forced entry?
Yes, where one doorset passed the fire test and the forced entry test, so one report names the period and the grade for that leaf.
Do rehabilitation centre fire doors need a smoke rating?
Yes, the leaves on the route carry Sa or S200 to BS EN 1634-3 beside their period, because residents on the way out meet smoke before flame.
What happens when a fire door will not shut?
A leaf that will not shut is written up against its own door the day the fault is found, and the centre does not wait for the next look round.