Martyn’s Law is the Terrorism (Protection of Premises) Act 2025. It will place duties on premises where 200 or more people may be present, with a standard tier of 200 to 799 and an enhanced tier of 800 or more. This guide explains the tiers and the physical measures worth considering. It is not legal advice.
- The ActTerrorism (Protection of Premises) Act 2025
- Royal AssentApril 2025
- The tiersStandard 200 to 799, enhanced 800 or more
- RegulatorSecurity Industry Authority
Not legal advice. This is a plain-English summary of the Act’s structure. It is not legal advice. Check the legislation and official guidance, or speak to a solicitor, before acting on it.
What Martyn’s Law is
Martyn’s Law is the common name for the Terrorism (Protection of Premises) Act 2025, which received Royal Assent in April 2025. It creates duties for those responsible for certain premises and events to prepare for the possibility of a terrorist attack, with the aim of reducing harm to the public. Our Martyn’s Law standards page summarises the key facts.
The idea is proportionate preparation: plan in advance how people would be protected, rather than improvising during an incident. The duties scale with capacity, which is why the Act uses two tiers.
Standard tier vs enhanced tier
The tier depends on how many people may reasonably be expected at the premises at the same time. Standard tier covers 200 to 799 people. Enhanced tier covers 800 or more, and also covers qualifying events of 800 or more.
| Tier | Capacity | What it means |
|---|---|---|
| Standard | 200 to 799 people | Lighter duties focused on procedures and preparedness. |
| Enhanced | 800 or more people | Stronger duties; those responsible must consider physical measures. |
| Qualifying events | 800 or more attendees | Treated under the enhanced tier. |
Capacity is about the number of people who could be present, not the number expected on a quiet day. If your peak attendance crosses a threshold, the higher tier applies.
What the Act does and does not require
The Act requires those responsible to assess the risk and put proportionate protective procedures and measures in place. For the enhanced tier, the Act expects physical measures to be considered as part of that assessment.
What it does not do is mandate specific products. The Act does not say you must install a named barrier, a rated door or a particular class of glazing. The choice of measures follows from your own risk assessment, which is why understanding the options matters more than buying hardware on day one.
That risk assessment belongs to the person responsible for the premises. It should be written down, dated, and revisited when the building use or capacity changes. A clear assessment is also what justifies the budget: it connects each measure to a named threat instead of to a catalogue.
The implementation period and the regulator
The Act provides an implementation period of at least 24 months from Royal Assent, giving premises time to assess, plan and act before duties bite. Use that window for the survey and specification work, not just the paperwork.
The regulator is the Security Industry Authority. It will oversee compliance once the duties are in force, so keeping your risk assessment, your reasoning and your evidence in one file is simple good practice.
How physical measures support the risk assessment
Physical measures turn a plan into protection. Hostile vehicle mitigation holds vehicles at a distance, which is what creates the stand-off that blast ratings assume. Barriers are rated under ISO 22343-1, which superseded PAS 68 and IWA 14-1, and a rating states the vehicle mass, speed, impact angle and penetration.
At the building envelope, blast resistant windows protect against the pressure wave, security doors rated to LPS 1175 resist forced entry, and LPS 1270 glazing controls hand-hole, arm-hole and body-passage attacks. Lockdown rooms give occupants somewhere safe to shelter while procedures run. Each measure answers a different part of the assessment, which is why public spaces usually need a mix rather than a single product.
None of this replaces the procedures the Act expects: evacuation, invacuation and lockdown plans, staff training and communication. Physical measures and procedures work as a pair.
Planters and benches with impact ratings can form part of a proportionate response. Our guide to HVM planters and street furniture explains how they fit a public realm scheme.
Why start during the implementation period
The implementation period is planning time, not waiting time. Surveys, risk assessments and specifications take months on a large estate, and rated products are made to order with lead times that follow the specification rather than the postcode. Starting early means specifying once, correctly, instead of rushing a second order later.
Early work also costs less to change. Moving a barrier line on a drawing is cheap; moving it after the concrete is poured is not. The same applies inside: choosing the glazing class before the frames are ordered avoids the expensive discovery that the specified glass needs a deeper frame.
Use the period to build the evidence file as well: the risk assessment, the reasons for each measure, and the test evidence for every rated product. If the regulator asks questions later, a dated file answers them.
Practical steps for premises in scope
- Confirm your tier. Work out the greatest number of people who could reasonably be present at one time.
- Assess the risk. Walk the site, list the threats that fit your location and use, and record your reasoning.
- Write the plan. Set out procedures for evacuation, invacuation, lockdown and communication.
- Consider physical measures. Where the assessment points to them, specify rated products with test evidence.
- Train and rehearse. Staff should know the plan before it is needed.
- Review regularly. Update the assessment when the use, layout or capacity changes.
Start during the implementation period, while there is time to survey properly and specify once. If you want help matching measures to your building, read our ISO 16933 guide and window film guide, or browse all ArxBridge guides.
Talking to your insurer and your supply chain
Insurers were asking about protective security before the Act, and the new duties give those conversations a sharper focus. An insurer cannot tell you whether you are compliant, because that is a legal question, but most will want to see that protective measures have been considered where the risk assessment points to them. Having the paperwork in order helps on both fronts.
Start with the risk assessment itself. Keep the written version current, note the date it was reviewed, and record which physical measures were considered and why each was accepted or set aside. A short written rationale beats a verbal one if questions come later. Where measures are installed, keep the test evidence with it: the rating of each doorset, the class of each glazed screen, the crash rating of each barrier line. Evidence is what turns a claim of protection into something checkable.
Then look at the supply chain. Physical measures only perform as specified if the products are what the schedule says and the installation matches the tested assembly. Ask suppliers for the test evidence behind each rating and keep it on file. For installation, use teams who fit the product as the tested assembly, because ad-hoc changes on site can undo the rating. Maintenance matters too: a lockdown door with a failed closer is not the measure the assessment assumed.
Keep a file. Risk assessment, product test evidence, installation records and maintenance logs in one place. It supports the insurance conversation and shows the assessment was acted on.
Review the file when the building changes. New entrances, changed opening hours, events with larger crowds and refurbishments can all move a premises between tiers or change which measures the assessment supports. A yearly review date in the diary keeps it from drifting. None of this is legal advice; where the duties are unclear for your premises, speak to a solicitor as well as your security adviser.
Does the Act name specific products we must install?
No. The Act does not mandate specific products. Enhanced tier premises must consider physical measures, but the choice follows from their own risk assessment.
We hold 750 people at peak. Which tier are we?
Standard tier covers 200 to 799 people, so 750 falls in the standard tier. If peak attendance could reach 800, the enhanced tier applies.
Is the Act in force yet?
The Act received Royal Assent in April 2025 with an implementation period of at least 24 months. Check official guidance for the current position before planning around a date.
Who enforces the duties?
The Security Industry Authority is the regulator named for the Act.
Do we still need procedures if we install physical measures?
Yes. Measures and procedures work together. Barriers and rated glazing protect the building; evacuation, invacuation and lockdown plans protect the people.
What counts as a qualifying event?
A public event where 800 or more people may be present at the same time. Qualifying events are treated under the enhanced tier, so the stronger duties apply to them as well.
Get a free quote
Related
More in guides for specifiers
Products
One supplier for the whole building envelope
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.