Martyn’s Law Enhanced Tier: Physical Measures and the Specifier Brief

Enhanced tier premises must consider physical measures under Martyn's Law. The four measure areas, the assessment duty, and what to put in a specifier brief.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed across the UK
Prefer to talk?+44 7352 267239

Get a free project quote

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Enhanced tier premises must consider physical measures under Martyn’s Law, not just write procedures. The four measure areas, the assessment duty behind them, and what a specifier needs to see.

  • 800 or more peopleThe enhanced tier line
  • Four measure areasMonitoring, movement, physical security, information
  • Compliance documentProcedures and measures sent to the SIA
  • Senior individualNamed to own compliance

Who the enhanced tier covers

The enhanced tier covers premises where 800 people or more may reasonably be expected to be present at the same time, at the busiest times. Qualifying events of 800 or more people are treated the same way. The count includes staff, and it turns on the busiest time.

There is one exception worth knowing before the count is done. Premises used for childcare, primary, secondary or further education, or as a place of worship, stay in the standard tier when 200 or more people may be present, even if the number goes to 800 or more. The Security Industry Authority page on Martyn’s Law and the SIA’s role as regulator sets out the tiers and the exception.

The four measure areas in the Act

Section 6 of the Act names four areas for public protection measures. They apply to enhanced tier premises and qualifying events only, and the responsible person must have appropriate measures in place in each area, so far as is reasonably practicable. The measures must be assessed and kept under review. The Home Office statutory guidance sets out the four areas and the examples for each.

Reasonably practicable means weighing the objectives against the cost, time and difficulty of putting a measure in place. A measure that is right for a city centre arena may not be right for a market hall, and the guidance warns against a one-size-fits-all approach.

Measure area What it covers Examples
Monitoring Watching the premises and its surroundings CCTV, staff on the ground, radio contact
Movement Controlling who goes in, out and around Access control, screening, locks and shutters
Physical security Strengthening the building and its perimeter Barriers, stand-off zones, security glazing
Security of information Keeping premises details out of hostile hands Auditing public plans, limiting floor plans

Measures work through people, processes and physical kit. Training is not a statutory requirement, yet if nobody at the premises knows how to carry out a measure, that measure is not properly in place. Our Martyn’s Law guide for premises gives the tier thresholds and the measures to consider.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Hostile vehicle mitigation and the perimeter

Vehicle as a weapon is one of the attack methods the guidance asks responsible persons to consider, alongside marauding attack, improvised explosive devices, fire as a weapon and hazardous substances. The physical security examples start outside the building: stand-off zones that increase the distance between vehicles and the premises, pedestrianised arrival routes, and barriers that stop a vehicle-borne attack.

A vehicle security barrier can take many forms: hostile vehicle mitigation, bollards, street furniture, fences, walls, gates, blockers, bunds, berms and planters. The choice follows the approach a vehicle could take and the space the site allows. One worked example describes a shop that judged bollards appropriate but not reasonably practicable at once, and set a plan to fit them in phases over the next few years.

A barrier line fails at its weakest gap. A rated bollard at the front door means little if a service yard round the back lets a vehicle reach the same wall.

Our hostile vehicle mitigation page covers the ratings and the barrier types, and the ISO 22343 guide explains how to read a rating. Planters and benches can carry a rating too, and our HVM planters guide shows how they are used in a public realm scheme.

Access control and the movement of people

Movement measures control, prohibit, restrict or reduce the movement of people into, out of and within the premises. Access controls are likely to be a fundamental part of most security regimes, and at many sites a perimeter is already obvious from the walls, fences or boundaries, with public access limited to certain doors, gates or vehicle entrances.

At the simple end, managing access can mean counting visitors in and out, or checking tickets, passes or identification. Larger premises may need more: passes for certain areas, screening of people and bags, and search policies at the entrance. The guidance gives a hospital example where staff entrances use automated access control with a pass and a PIN, fire exits are alarmed and monitored from a central control room, and ward access is by staff pass or doorbell entry.

Access control also serves the lockdown procedure. Locks, shutters, screens and barriers can secure the premises out of hours, secure back of house areas, or secure parts of the premises during a lockdown. Our turnstiles guide covers entrance control for a busy building.

Lockdown doors and the building envelope

Lockdown is one of the four public protection procedures, and it means securing the premises to prevent individuals entering or leaving, for example to restrict the movement of an attacker by locking doors, closing shutters or using available barriers. The doors that make a lockdown work are the ones that can be locked quickly and that hold when they are locked.

The guidance also names protective and security glazing: blast-resistant facades, glass and doors, safety glass and anti-shatter film. Glass can shatter and cause very significant injuries in an explosive device or vehicle attack, and anti-shatter film can be an appropriate mitigation where stand-off distance already limits the effect of a larger device. One cinema example weighed film against cost and effect, and chose a stand-off zone built from street furniture instead.

Physical measures must not clash with the procedures they support. Movement measures should be considered when planning an evacuation, invacuation or lockdown, and other legislation, including fire safety, must be taken into account. A door that locks an attacker out must still let people out when the fire alarm sounds.

The compliance document and the senior individual

Enhanced tier premises and qualifying events must do more than put measures in place. They must document the procedures and measures, assess how they reduce the risk of physical harm and the vulnerability of the premises, and send that document to the SIA. A revised compliance document must be sent to the SIA within 30 days of its revision.

Where the responsible person is an organisation rather than an individual, it must assign a member of staff involved in the management or control of the organisation to be responsible for ensuring compliance. That person is called the senior individual, and the same rule applies to qualifying events run by an organisation.

Both tiers must notify the SIA who the responsible person is, once the law comes into effect, through an online portal the SIA is building. The SIA will invite volunteers to test it from early 2027. Our Martyn’s Law standards page summarises the tiers, the implementation period and the regulator.

What to put in a specifier brief

A specifier brief for enhanced tier work starts with the figures the tier turns on: the greatest number of people who may be present at the same time, and how it was worked out. Add the layout: entrances, exits, the perimeter, the vehicle approaches, the queueing areas and the rooms where people gather.

Next comes the assessment itself. Name the attack methods considered, the measures already in place, and the gaps found. For each gap, say what is proposed and why, and record the measures considered and set aside, with the reason. That written rationale shows the reasonably practicable test was applied, and it is what the senior individual relies on for the compliance document.

Close the brief with the evidence and the review. Every rated product should arrive with its test evidence, and the brief should say who checks it and where it is filed. Set a review date, because the duty is to keep measures under review, and a change in use, layout or capacity can move a premises between tiers. The transport hub guide shows the same thinking for a crowded building type.

Does the Act name the products an enhanced tier premises must install?

No. The Act requires appropriate measures to be considered and put in place so far as is reasonably practicable. The guidance gives examples, not a shopping list, and the choice follows the risk assessment.

What are the four public protection measure areas?

Monitoring, movement of people, physical safety and security, and security of information. They are for enhanced tier premises and qualifying events, and each must be appropriate and reasonably practicable.

Who is the senior individual?

Where the responsible person is an organisation, a member of staff involved in its management or control must be assigned to own compliance. That person is the senior individual.

Must the compliance document go to the SIA?

Yes, for enhanced tier premises and qualifying events. The document states the procedures and measures in place and assesses how they reduce risk, and a revised copy must be sent within 30 days.

Can a measure wait if it is not reasonably practicable now?

The duty is to put in place what is appropriate so far as is reasonably practicable, weighing objectives against cost, time and difficulty. A measure judged not practicable now should be recorded with the reason, and reviewed when circumstances change.

Ready to specify measures for an enhanced tier premises?Send the capacity figure, the site layout and the measures in place.
Contact us for a free quote

Related

More in guides for specifiers

10 mistakes when specifying certified security doors 10 steps to specify an LPS 1175 door Acceptance and Snagging of a Security Door or Barrier Job Access Control Doors Acoustic Doors: Ratings and Specification After a Forced Entry Attempt: Checking a Security Door Airport Security Doors Anti-Ligature Doors for Mental Health Wards Anti-Ram Bollards Anti-ram gates and barriers: protecting vehicle entrances Arcade Security Doors Explained Automatic Doors Automatic Gates Cost Factors Automatic Vehicle Barriers Ballistic Panels Bank Security Doors Bingo Hall Security Doors Explained Blast doors: glazed vs solid and how they are rated Blast protection window film: what it does and what it cannot do Blast resistant windows: what drives the cost and how to specify them Bollard Cost Factors Explained Bollard regulations in the UK: spacing, height and depth Bookmaker Security Doors Explained Builders Merchant Security Doors Bullet Resistant Glass Cost Factors Bullet resistant glass ratings explained: BR1 to BR7 and SG classes Bullet resistant vs bulletproof glass: what the difference means Buying Security Doors and HVM Through Public Frameworks Car Park Security Doors Explained Car Showroom Security Doors Casino Security Doors Explained CDM 2015 Duties When Security Doors, Shutters or HVM Are Installed Cinema Security Doors Cleanroom Doors Cold Store Doors College Security Doors Commissioning, Handover and the O&M Manual for Security Doors and HVM Communal entrance doors for flats: Secured by Design and what to specify Community Centre Security Doors Control Room Doors Court Security Doors Crash Rated Fences and HVM Fencing Explained Data centre physical security: doors, glazing, HVM and shielding by zone Dental Practice Security Doors Depot Security Doors Explained Door Entry Systems Due Diligence When Selecting Vehicle Security Barriers Emergency Exit Doors EMP Shielding Cost Factors Explained Exhibition Centre Fire Door Rules Exhibition Centre Security Doors Factory Security Doors Faraday cage vs RF shielded room: what a business needs FB4 vs FB6 vs FB7: how to choose a ballistic rating Fire and security doors: how dual certification works Fire Compartmentation Fire Curtains Fire Door Certification Fire Door Closers Explained Fire Door Cost Factors Fire Door Duties of the Accountable Person Fire Door Gaps Fire Door Hardware Explained Fire door inspection checklist for steel and timber doors Fire Door Maintenance Fire Door Regulations Care Homes Fire Door Regulations for A and E Departments Fire Door Regulations for Airports Explained Fire Door Regulations for Bowls Clubs Fire door regulations for commercial buildings in the UK Fire Door Regulations for Dialysis Centres Fire Door Regulations for Hockey Clubs Fire Door Regulations for Hospitals Explained Fire Door Regulations for Offices Explained Fire Door Regulations for Operating Theatres Fire Door Regulations for Retail Explained Fire Door Regulations for Schools Explained Fire Door Regulations for Snooker Clubs Fire Door Regulations for Stadiums Fire Door Regulations for Student Accommodation Fire Door Regulations for Warehouses Fire Door Regulations Leisure Centres Fire Door Regulations Restaurants Fire Door Remediation Programme for Housing Providers Fire Door Rules for Badminton Clubs Fire Door Rules for Bingo Halls Fire Door Rules for Bookmakers Fire Door Rules for Bowling Alleys Fire Door Rules for Car Parks Fire Door Rules for Car Showrooms Fire Door Rules for Cinemas Fire Door Rules for Climbing Centres Fire Door Rules for Colleges Fire Door Rules for Community Centres Fire Door Rules for Cricket Clubs Fire Door Rules for Dental Practices Fire Door Rules for Depots Explained Fire Door Rules for Golf Clubs Fire Door Rules for GP Surgeries Fire Door Rules for Gyms Explained Fire Door Rules for Ice Rinks Fire Door Rules for Maternity Units Fire Door Rules for Mental Health Units Fire Door Rules for Museums Fire Door Rules for Oncology Units Fire Door Rules for Opticians Fire Door Rules for Pawnbrokers Fire Door Rules for Petrol Stations Fire Door Rules for Pharmacies Fire Door Rules for Ports Fire Door Rules for Post Offices Fire Door Rules for Prisons Fire Door Rules for Rehabilitation Centres Fire Door Rules for Self Storage Fire Door Rules for Shopping Centres Fire Door Rules for Squash Clubs Fire Door Rules for Supermarkets Fire Door Rules for Swimming Pools Fire Door Rules for Tennis Clubs Fire Door Rules for Theatres Fire Door Rules for UK Arcades Fire Door Rules for UK Casinos Fire Door Rules for UK Hospices Fire Door Rules for Walk-in Centres Fire Door Signage Fire Door Vision Panels Fire Doors and Gateway 2 in Higher-Risk Buildings Fire Rated Glass Cost Explained Fire Rated Sliding Doors Explained Fire Rated Windows Cost Factors Fire Rated Windows Explained Fire Safety Enforcement Notices and Fire Doors: What the Responsible Person Must Do Flat Entrance Doors: PAS 24 and Fire Rated Forced Entry vs Ballistic vs Blast: Which Rating a Site Needs Garage Security Doors Explained Gate Automation Explained Golden Thread Records for Fire Doors GP Surgery Security Doors Explained Gym Security Doors Explained High Speed Doors HMO Fire Doors Hospice Security Doors Explained Hospital Security Doors: Wards, A&E, Plant Hospital Security Gates Hotel Fire Doors Hotel Security Doors How to choose HVM bollards: fixed, shallow mount, removable and automatic How to keep an LPS 1175 door rating valid after installation How to Specify Fire Doors in a Housing Tender How to specify security doors: a checklist for architects How to Verify a Secured by Design Listing How to Verify an LPS 1175 Certificate on Red Book Live How to Write an Operational Requirement for Physical Security HVM planters and street furniture: protection that blends in In-Service Care of Vehicle Security Barriers Installation Handover: LPS 1175 Doors and PAS 68 Barriers Intumescent Seals ISO 16933 explained: EXV and SB classes and hazard ratings ISO 22343 vehicle security barriers explained Keeping a Dual-Certified Fire and Security Door Valid in Service Laboratory Security Doors Layered Security for a Site: Deter, Detect, Delay, Mitigate, Respond Lead Times and Programme Risks for LPS 1175 Doors Leisure Centre Security Doors Library Security Doors Listed Building Fire Doors Loading Bay Doors Explained Lockdown and Access Control Hardware on an LPS 1175 Door LPS 1175 Gates and Grilles Explained LPS 1175 Issue 8 explained: from SR1 to SR8 to A1 to H20 LPS 1175 Roller Shutters LPS 1175 vs ASTM F2781 and Other US Ratings Explained LPS 1175 vs EN 1627: how UK and European burglar resistance ratings compare LPS 1175 vs PAS 24: which security standard does your door need? LPS 1175 Windows and Walling Explained Martyn’s Law and Places of Worship: What a Buyer Checks for Doors and Entry Control Martyn’s Law Standard Tier: Procedures, Doors and Shutters Martyn’s Law Timeline and the SIA Regulator Martyn’s Law: what premises must do and which physical measures to consider Master Key Systems MRI and RF shielded rooms: how they work and what to specify Museum Security Doors NPSA Catalogue of Security Equipment (CSE) Explained NPSA Forced Entry and Blast Guidance for Government Sites NPSA Guidance on Lockdown and Marauding Attack: What It Asks of Doors and Entrances Office Security Doors Optician Security Doors Explained Panic Hardware PAS 24 requirements for doors and windows explained PAS 68 Bollard Foundations Explained PAS 68 bollards: ratings, spacing and cost factors PAS 68 vs IWA 14 vs ISO 22343: hostile vehicle mitigation standards explained Pawnbroker Security Doors Explained Pedestrian Gates Petrol Station Security Doors Pharmacy Security Doors Planning Permission for Security Shutters, Gates and Bollards on Commercial Premises Plant room doors: fire, security and ventilation requirements Plant Room Fire Doors Port Security Doors Post Office Security Doors Explained Powder coating vs galvanising vs paint for steel Preliminary Market Engagement for Security Doors and HVM Prison Security Doors Programming a Security Door and Barrier Package on a Live Site Public-Sector Tender Response Checklist for Security Door and HVM Supply Reading a PAS 24 and SBD Door Test Report Regulation 38 Fire Safety Information at Handover for Fire-Rated Security Doorsets Replacing Security Doors in an Occupied Building Restaurant Security Doors Retail Security Doors Revolving Doors RF shielding standards and how shielded rooms are tested Rising Bollard Cost Factors Road Blocker Cost Factors Explained Road Blockers Explained Roller Shutter Cost Factors: What Drives the Price Roller shutter regulations in the UK: safety and maintenance Safe room and panic room doors: specification basics Safety Duties for Powered Doors, Gates and Barriers on Commercial Sites School Security Doors Sectional Doors Secured by Design explained: is it mandatory for doors? Secured by Design vs NPSA vs LPCB: Which One You Need Security Door Locks Security Door Maintenance Checklist Security Doors and Access for Everyone: What Approved Document M Asks Security Doors for A and E Departments Security Doors for Badminton Clubs Security Doors for Bowling Alleys Security Doors for Bowls Clubs Security Doors for Climbing Centres Security Doors for Cricket Clubs Security Doors for Dialysis Centres Security Doors for Golf Clubs Security Doors for Hockey Clubs Security Doors for Ice Rinks Security Doors for Maternity Units Security Doors for Mental Health Units Security Doors for Oncology Units Security Doors for Operating Theatres Security Doors for Rehabilitation Centres Security Doors for Snooker Clubs Security Doors for Squash Clubs Security Doors for Swimming Pools Security Doors for Tennis Clubs Security Doors for Walk-in Centres Security Doors West Midlands Explained Security Fencing Security Gates Cost Factors Explained Security shutters vs high performance roller doors Security shutters vs retractable grilles: which suits retail and commercial openings? Security Turnstiles Explained Security Window Film Security Windows for Schools Explained Self Storage Security Doors Server Room Doors Explained Shopping Centre Security Doors Smoke Control Doors Explained Smoke Curtains Specification Mistakes When Mixing LPS 1175, PAS 24 and SBD in One Tender SR2 vs SR3 vs SR4 security doors: choosing the right LPS 1175 level Stadium Security Doors Steel Door Frames Steel vs aluminium security doors: strength, ratings and looks Steel vs timber fire doors: which suits your building? Student Accommodation Security Doors Substation doors: security, ventilation and specification Supermarket Security Doors Telescopic Bollards Tender Evaluation Criteria and Scoring for Security Doors and HVM The Scope of a Maintenance Contract for Security Doors and Barriers Theatre Security Doors Thermal and Weather Performance of External Security Doorsets Thermally broken steel security doors: U-values and certification Traffic Calming as Hostile Vehicle Mitigation Transport hub security requirements Turnstile Cost Factors Explained Turnstile vs speed gate vs security portal: choosing entrance control Types of security doors for commercial buildings University Security Doors Explained Vehicle Dynamics Assessment: What It Tells the Buyer Before a Barrier Is Specified Warehouse Security Doors Explained Warehouse Security Gates Warranty, Defects Liability and Guarantees for Security Doors and Barriers What affects the cost of a bullet resistant door What affects the cost of a high-security door in the UK Window Security Bars View all →

Products

One supplier for the whole building envelope

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.