Certified physical security

ArxBridge
Steel door sample in a security test frame with an assessor in a UK test laboratory

ArxBridge

Automatic Vehicle Barriers

Automatic vehicle barriers: barrier arms for car parks and entrances, with cycle time, access control, safety devices, fail position and one schedule.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed across the UK
Prefer to talk?+44 7352 267239

Get a free project quote

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

An automatic vehicle barrier rises for a vehicle the site expects and stays down for the rest. It gives a car park or an entrance the control of a gate with the speed of an arm, and it suits a lane where vehicles must pass one at a time and be checked as they do.

The order starts with the lane, not with the barrier. A staff car park that fills in the morning asks for a different arm from a site entrance where lorries arrive through the day, and a lane that must pass a vehicle every few seconds asks for a different drive from a lane that opens a few times an hour.

The arm, the drive, the access control and the safety devices all sit inside one schedule, and an order that names each one plainly gets the right barrier on the right lane. The gate lines that share the boundary are covered in our security gates page, and how a powered gate is driven is covered in our gate automation guide.

  • BS EN 12453Safety in use of power operated doors
  • ISO 22343-1Vehicle security barrier ratings
  • 1,200 mm / 500 mmProtectUK gap cap and height floor
  • Loop, photocell, edgeThe three safety devices on the lane

Where an automatic barrier earns its place: car parks, entrances and the lane in

A staff car park is where most automatic barriers stand, across the lane in, where the arm rises for a card the site knows and stays down for the rest. The barrier keeps the spaces for the staff who belong there, and the record shows who entered and when.

A site entrance takes the same barrier in a longer lane, where lorries and visitors arrive through the day and must be checked before they pass. The barrier holds each vehicle at the gate while the check runs, so the site knows what is inside before the vehicle reaches the yard.

A transport hub takes a barrier where vehicles and people cross the same ground, and the lane must keep them apart. The barrier holds the vehicles on their lane while the pedestrians use theirs, and the hubs that run that mix are covered in the transport hubs sector page, while the gates that run beside the barrier are covered in our sliding vehicle gates page.

Barrier arms, rising bollards and gates: the control that fits the entrance

A barrier arm suits a lane where vehicles must pass fast and be checked as they do. The arm rises in seconds and drops behind the vehicle, so the lane keeps moving, and it asks for little ground work beside the housing, so it suits a car park lane where the queue must not grow.

A rising bollard suits a lane where a vehicle must be stopped, not only checked. The bollard rises from the road and stands in the way of a vehicle that tries to drive through, so it suits an entrance where the threat is a vehicle that will not stop, and the powered type is covered in our rising bollards page.

A gate suits a lane where the line must close fully, with no gap a vehicle can use. The gate closes the whole opening, so it suits a boundary where the site must stay shut at night, and the fixed bollards that close the gaps beside it are covered in our security bollards page, while the rated options for the gate line are covered in our anti-ram gates and barriers guide.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Cycle time and throughput: how many vehicles the lane must pass

The cycle time decides how many vehicles the lane can pass in an hour. An arm that rises and drops in a few seconds keeps a staff car park moving in the morning, while an arm that takes longer leaves a queue on the road outside, so the cycle time belongs on the order beside the lane.

Throughput follows the peak, not the average. A lane that passes ten vehicles an hour through the day and a hundred in the morning must be proved for the morning, so the peak count belongs on the order, and the drive must be proved for that duty, because a drive that overheats at the peak leaves the lane shut when the site needs it open.

The access control sets the real speed of the lane, because a reader that takes seconds to answer slows every vehicle behind it. The reader, the fob and the plate check each add their own time, so the whole check belongs on the order with the arm, and what each step up the line adds to the build is worked through in our security gates cost factors guide.

Peak hour on the lane: passing vehicles while one lane stands shut

The lane earns its keep at peak hour, when the morning flow arrives all at once and the queue forms on the road outside. When one lane stands shut for repair, the lane that stays open must carry the whole flow, so the drive on the open lane is proved for the peak, not for the average hour. The reader, the loop and the photocell on the open lane each take the extra work too, and a slow reader at peak hour holds every vehicle behind it, so the reader time belongs on the order beside the arm. A lane that must stop a vehicle outright takes a blocker rather than an arm, and the road blockers guide covers the type that rises from the road.

Closing a lane for repair starts with the vehicles, not with the barrier. The shut lane is marked off before the work starts, the vehicles are sent to the lane that stays open, and the open lane is watched through the first peak after the change, because a lane that copes at midday can still fail at eight in the morning. A drive that runs hot at the peak will stop when the queue is longest, so the order names the peak count beside the cycle time. The gate automation guide names the drive behind a powered barrier. Readers, fobs and biometrics are named in the security turnstiles guide, with the lane they serve beside them.

Lane state What the lane carries What the order names
Both lanes open The flow split between two lanes Cycle time, reader time and drive duty
One lane shut The whole flow on one lane Peak count and drive proved for the peak
Repair under way No vehicles while work runs Fail position, manual release and marking
Lane back in use The flow shared by two lanes again Loop, photocell and edge tested again

One lane down for repair: the shift the other lane must carry

A repair that shuts a lane is planned for the quiet hour, and the lane comes back before the next peak, because a lane shut at eight in the morning is a queue on the road outside. The service contract is what keeps the open lane running while the shut lane is repaired, and it names the parts the site holds and how fast a repair crew reaches the site, because a lane with no spare arm stays shut till the part arrives. The arm that comes back is proved with its safety devices before the lane opens again, and the loop, the photocell and the edge are checked with the arm, because each device watches a different danger.

Write the repair plan onto the schedule beside the barrier, with the lane, the drive and the safety devices on the same line, so the barrier that comes back is the barrier that was proved. The sliding vehicle gates page names the gates that run beside a fence. The anti-ram gates and barriers guide weighs the options for the gate line, and the security gates cost factors guide shows what each step up the line adds.

The second vehicle behind the first: tailgating on a barrier lane

A barrier arm that rises for one vehicle and drops behind it can still let a second vehicle through, because the second vehicle follows the first through the lane before the arm comes down. Tailgating is the gap the lane leaves open after the check has run, and the arm timing, the loop in the floor and the photocell across the lane are what close it. The loop holds the arm up while a vehicle waits underneath, and the photocell stops the arm before it meets anything, so each device watches a different danger, and a lane without all three has a gap in its safety.

The arm must come down fast enough that the second vehicle cannot follow, and the drive must be proved for the peak the lane carries, because a drive that overheats at the peak leaves the lane shut when the site needs it open. Throughput follows the peak, not the average: a lane that passes ten vehicles an hour through the day and a hundred in the morning must be proved for the morning, so the peak count belongs on the order beside the cycle time. The readers, fobs and biometrics in the lane are named in the security turnstiles guide, and the drive behind a powered barrier is named in the gate automation guide.

Tailgate risk What stops it What the order names
Second vehicle follows Fast arm, loop, photocell Cycle time, loop, photocell
Arm too slow Drive proved for the peak Peak count, drive duty
Reader too slow Reader that answers fast Reader time, plate check time
Lane left open Arm drops behind each vehicle Drop time, fail position

Spares on the quote keep the lane moving when a part wears out

A barrier lane that opens and shuts many times a day wears the drive, the arm and the loop, and the service contract is what keeps the lane moving when a part wears out. The contract should name the drive, the arm, the loop, the photocell and the safety edge, with the spares the site holds and the time a repair takes, because a lane with no spare arm is a lane shut while the part is ordered. The inspection round looks at every barrier, loop and photocell in turn, and each fault is written down the same day, with the barrier and the fault beside it.

Read two quotes side by side and check that each one names the same arm, the same motor and the same safety devices. A quote that leaves the safety edge off the list has not cut the cost, it has only pushed it to the day the barrier is fitted, and a quote that leaves the service contract off the list leaves the lane with no one to call when the drive fails. The gates that run along a fence line are named on the sliding vehicle gates page, the options for the gate line are weighed in the anti-ram gates and barriers guide, the cost of each step up the line is shown in the security gates cost factors guide, and the blockers that lift out of the road are named in the road blockers guide.

Access control on the lane: readers, ANPR and the intercom

Access control on a barrier lane decides who can raise the arm, and when. Staff take a card or a fob for the lanes they use every day, and a fob can be stopped when staff leave, because a fob costs nothing to stop and a key costs a new one.

ANPR reads the plate as the vehicle approaches, and the arm rises for a plate the site knows. The camera must read the plate in the rain and in the dark, so the camera and the light beside it belong on the order with the barrier, and the plates that may pass belong on the list the site keeps.

Visitors take the intercom, and a voice at the gate lets them ask to be let in. The intercom should reach the person who can open the lane, and the lane should hold the vehicle while the check runs, so no visitor waits on the road. Readers, fobs and biometrics in the lane are covered in our security turnstiles guide, and how a powered barrier is driven is covered in our gate automation guide.

Safety devices and the loop: what stops the arm coming down

A barrier arm is a machine, and BS EN 12453 sets out how it must be made safe to use. Loops in the road, photocells across the lane and a safety edge on the arm each stop the arm coming down on a vehicle or a person, and a lane without them has no proven safety at all.

The loop in the floor holds the arm up while a vehicle waits underneath, and the photocell stops the arm before it meets anything. Each device watches a different danger, so a lane without all three has a gap in its safety, and the rules the line must meet are set out in our bollard regulations guide.

Prove the safety devices with the barrier, as one assembly, rather than fitting them after the barrier is in the ground. A loop blind to a vehicle, a photocell set too low or an edge that does not reach the arm each leaves the lane unsafe, so the devices belong on the test report with the barrier. The blockers that rise from the road are covered in our road blockers guide, and the ratings in full are in our ISO 22343 vehicle security barriers guide.

Power loss and the fail position: what the barrier does when the power goes

When the power goes, the barrier must fail in the position the site needs, and the position is named on the schedule before the order is placed. An arm that stays down traps vehicles inside, and an arm that rises lets them through, so the site decides which failure it can live with.

The manual release must work on power failure as well as on alarm, and it must be written into the order beside the motor. A release that needs power to work is no release at all, so the release is checked on the inspection round, and the checks each round should make are set out in our security door maintenance checklist.

A barrier that must stay shut on power loss needs a lock that holds it there, and a barrier that must open needs a release that frees it. The choice belongs on the schedule, because a barrier fitted with the wrong fail position leaves the site open or shut at the worst time, and the ratings behind the line are set out on our vehicle impact ratings page.

The arm, the housing and the ground it stands in

The housing holds the drive, and it must stand on a foundation that keeps it true. A housing set in a shallow foundation rocks under the arm, so the depth, the concrete and the fixings belong on the schedule beside the barrier, and the foundation must not cut through the services under the lane.

The arm must take the wind the site sees, because a long arm on an exposed site takes more wind than a short arm in a sheltered yard. The arm should be chosen for the gusts the site sees, not for the calm days between them, and the bollards that stand beside it are covered in our PAS 68 bollards guide, while the options for the line are worked through in our choosing HVM bollards guide.

Drainage decides how long a barrier lasts. A housing that holds water corrodes the drive from below, so the drain beside the housing belongs on the schedule, and the inspection round should look for the housing that no longer drains. The line that hides its protection in street furniture is covered in our HVM planters and street furniture guide, and the line that must stop a vehicle is covered in our hostile vehicle mitigation page.

The barrier order: one schedule for the whole entrance

Write the enquiry as one schedule with a line for every barrier on the site, and put the position, the arm length, the drive, the access control, the safety devices and the fail position on each line, so the barrier that arrives is the barrier that was proved.

Keep the test report, the rating and the service schedule with the barrier from the day it arrives, and write the inspection routine into the handover pack, so the next team can see what was proved and what must be checked. The columns such a schedule needs are set out in our how to specify security doors guide, and what each step up the scale adds to the build is worked through in our bollard cost factors guide.

Position Barrier Control What to check
Staff car park Barrier arm Card reader Cycle time, loops, release
Site entrance Barrier arm ANPR Camera, light, intercom
Visitor lane Barrier arm Intercom Photocells, edge, housing
Goods yard Rising bollards Fob Rating, pit, drainage
Boundary gate Sliding gate Card reader Rating, gaps, release

An automatic barrier opens the lane for the vehicles the site expects and closes it to the rest, so the arm, the drive, the access control and the safety devices must all sit on the same schedule.

What is an automatic vehicle barrier?

A barrier arm that rises for a vehicle the site expects and stays down for the rest. It gives a car park or an entrance the control of a gate with the speed of an arm.

Barrier arm or rising bollard: which fits?

The threat decides. An arm suits a lane where vehicles must pass fast and be checked as they do, and a rising bollard suits a lane where a vehicle must be stopped, not only checked.

What safety devices does a barrier lane need?

BS EN 12453 sets out the safety in use of power operated doors, and loops, photocells and safety edges each stop the arm coming down on a vehicle or a person in its way.

What happens to a barrier in a power cut?

It must fail in the position the site needs, and the position is named on the schedule before the order is placed. An arm that stays down traps vehicles inside, and an arm that rises lets them through.

Who checks automatic vehicle barriers?

The team that runs the site, on the routine the maintenance plan sets. Each record names the barrier, the fault, the repair and the date it was fixed.

To get one quote for every opening, use the security door enquiry checklist and send the list in one go.

Specifying automatic vehicle barriers for a site?Send the lane plan and the vehicles the lane must pass for a tested barrier quotation.
Get a free quote

Related

More in guides for specifiers

10 mistakes when specifying certified security doors 10 steps to specify an LPS 1175 door Acceptance and Snagging of a Security Door or Barrier Job Access Control Doors Acoustic Doors: Ratings and Specification After a Forced Entry Attempt: Checking a Security Door Airport Security Doors Anti-Ligature Doors for Mental Health Wards Anti-Ram Bollards Anti-ram gates and barriers: protecting vehicle entrances Arcade Security Doors Explained Automatic Doors Automatic Gates Cost Factors Ballistic Panels Bank Security Doors Bingo Hall Security Doors Explained Blast doors: glazed vs solid and how they are rated Blast protection window film: what it does and what it cannot do Blast resistant windows: what drives the cost and how to specify them Bollard Cost Factors Explained Bollard regulations in the UK: spacing, height and depth Bookmaker Security Doors Explained Builders Merchant Security Doors Bullet Resistant Glass Cost Factors Bullet resistant glass ratings explained: BR1 to BR7 and SG classes Bullet resistant vs bulletproof glass: what the difference means Buying Security Doors and HVM Through Public Frameworks Car Park Security Doors Explained Car Showroom Security Doors Casino Security Doors Explained CDM 2015 Duties When Security Doors, Shutters or HVM Are Installed Cinema Security Doors Cleanroom Doors Cold Store Doors College Security Doors Commissioning, Handover and the O&M Manual for Security Doors and HVM Communal entrance doors for flats: Secured by Design and what to specify Community Centre Security Doors Control Room Doors Court Security Doors Crash Rated Fences and HVM Fencing Explained Data centre physical security: doors, glazing, HVM and shielding by zone Dental Practice Security Doors Depot Security Doors Explained Door Entry Systems Due Diligence When Selecting Vehicle Security Barriers Emergency Exit Doors EMP Shielding Cost Factors Explained Exhibition Centre Fire Door Rules Exhibition Centre Security Doors Factory Security Doors Faraday cage vs RF shielded room: what a business needs FB4 vs FB6 vs FB7: how to choose a ballistic rating Fire and security doors: how dual certification works Fire Compartmentation Fire Curtains Fire Door Certification Fire Door Closers Explained Fire Door Cost Factors Fire Door Duties of the Accountable Person Fire Door Gaps Fire Door Hardware Explained Fire door inspection checklist for steel and timber doors Fire Door Maintenance Fire Door Regulations Care Homes Fire Door Regulations for A and E Departments Fire Door Regulations for Airports Explained Fire Door Regulations for Bowls Clubs Fire door regulations for commercial buildings in the UK Fire Door Regulations for Dialysis Centres Fire Door Regulations for Hockey Clubs Fire Door Regulations for Hospitals Explained Fire Door Regulations for Offices Explained Fire Door Regulations for Operating Theatres Fire Door Regulations for Retail Explained Fire Door Regulations for Schools Explained Fire Door Regulations for Snooker Clubs Fire Door Regulations for Stadiums Fire Door Regulations for Student Accommodation Fire Door Regulations for Warehouses Fire Door Regulations Leisure Centres Fire Door Regulations Restaurants Fire Door Remediation Programme for Housing Providers Fire Door Rules for Badminton Clubs Fire Door Rules for Bingo Halls Fire Door Rules for Bookmakers Fire Door Rules for Bowling Alleys Fire Door Rules for Car Parks Fire Door Rules for Car Showrooms Fire Door Rules for Cinemas Fire Door Rules for Climbing Centres Fire Door Rules for Colleges Fire Door Rules for Community Centres Fire Door Rules for Cricket Clubs Fire Door Rules for Dental Practices Fire Door Rules for Depots Explained Fire Door Rules for Golf Clubs Fire Door Rules for GP Surgeries Fire Door Rules for Gyms Explained Fire Door Rules for Ice Rinks Fire Door Rules for Maternity Units Fire Door Rules for Mental Health Units Fire Door Rules for Museums Fire Door Rules for Oncology Units Fire Door Rules for Opticians Fire Door Rules for Pawnbrokers Fire Door Rules for Petrol Stations Fire Door Rules for Pharmacies Fire Door Rules for Ports Fire Door Rules for Post Offices Fire Door Rules for Prisons Fire Door Rules for Rehabilitation Centres Fire Door Rules for Self Storage Fire Door Rules for Shopping Centres Fire Door Rules for Squash Clubs Fire Door Rules for Supermarkets Fire Door Rules for Swimming Pools Fire Door Rules for Tennis Clubs Fire Door Rules for Theatres Fire Door Rules for UK Arcades Fire Door Rules for UK Casinos Fire Door Rules for UK Hospices Fire Door Rules for Walk-in Centres Fire Door Signage Fire Door Vision Panels Fire Doors and Gateway 2 in Higher-Risk Buildings Fire Rated Glass Cost Explained Fire Rated Sliding Doors Explained Fire Rated Windows Cost Factors Fire Rated Windows Explained Fire Safety Enforcement Notices and Fire Doors: What the Responsible Person Must Do Flat Entrance Doors: PAS 24 and Fire Rated Forced Entry vs Ballistic vs Blast: Which Rating a Site Needs Garage Security Doors Explained Gate Automation Explained Golden Thread Records for Fire Doors GP Surgery Security Doors Explained Gym Security Doors Explained High Speed Doors HMO Fire Doors Hospice Security Doors Explained Hospital Security Doors: Wards, A&E, Plant Hospital Security Gates Hotel Fire Doors Hotel Security Doors How to choose HVM bollards: fixed, shallow mount, removable and automatic How to keep an LPS 1175 door rating valid after installation How to Specify Fire Doors in a Housing Tender How to specify security doors: a checklist for architects How to Verify a Secured by Design Listing How to Verify an LPS 1175 Certificate on Red Book Live How to Write an Operational Requirement for Physical Security HVM planters and street furniture: protection that blends in In-Service Care of Vehicle Security Barriers Installation Handover: LPS 1175 Doors and PAS 68 Barriers Intumescent Seals ISO 16933 explained: EXV and SB classes and hazard ratings ISO 22343 vehicle security barriers explained Keeping a Dual-Certified Fire and Security Door Valid in Service Laboratory Security Doors Layered Security for a Site: Deter, Detect, Delay, Mitigate, Respond Lead Times and Programme Risks for LPS 1175 Doors Leisure Centre Security Doors Library Security Doors Listed Building Fire Doors Loading Bay Doors Explained Lockdown and Access Control Hardware on an LPS 1175 Door LPS 1175 Gates and Grilles Explained LPS 1175 Issue 8 explained: from SR1 to SR8 to A1 to H20 LPS 1175 Roller Shutters LPS 1175 vs ASTM F2781 and Other US Ratings Explained LPS 1175 vs EN 1627: how UK and European burglar resistance ratings compare LPS 1175 vs PAS 24: which security standard does your door need? LPS 1175 Windows and Walling Explained Martyn’s Law and Places of Worship: What a Buyer Checks for Doors and Entry Control Martyn’s Law Enhanced Tier: Physical Measures and the Specifier Brief Martyn’s Law Standard Tier: Procedures, Doors and Shutters Martyn’s Law Timeline and the SIA Regulator Martyn’s Law: what premises must do and which physical measures to consider Master Key Systems MRI and RF shielded rooms: how they work and what to specify Museum Security Doors NPSA Catalogue of Security Equipment (CSE) Explained NPSA Forced Entry and Blast Guidance for Government Sites NPSA Guidance on Lockdown and Marauding Attack: What It Asks of Doors and Entrances Office Security Doors Optician Security Doors Explained Panic Hardware PAS 24 requirements for doors and windows explained PAS 68 Bollard Foundations Explained PAS 68 bollards: ratings, spacing and cost factors PAS 68 vs IWA 14 vs ISO 22343: hostile vehicle mitigation standards explained Pawnbroker Security Doors Explained Pedestrian Gates Petrol Station Security Doors Pharmacy Security Doors Planning Permission for Security Shutters, Gates and Bollards on Commercial Premises Plant room doors: fire, security and ventilation requirements Plant Room Fire Doors Port Security Doors Post Office Security Doors Explained Powder coating vs galvanising vs paint for steel Preliminary Market Engagement for Security Doors and HVM Prison Security Doors Programming a Security Door and Barrier Package on a Live Site Public-Sector Tender Response Checklist for Security Door and HVM Supply Reading a PAS 24 and SBD Door Test Report Regulation 38 Fire Safety Information at Handover for Fire-Rated Security Doorsets Replacing Security Doors in an Occupied Building Restaurant Security Doors Retail Security Doors Revolving Doors RF shielding standards and how shielded rooms are tested Rising Bollard Cost Factors Road Blocker Cost Factors Explained Road Blockers Explained Roller Shutter Cost Factors: What Drives the Price Roller shutter regulations in the UK: safety and maintenance Safe room and panic room doors: specification basics Safety Duties for Powered Doors, Gates and Barriers on Commercial Sites School Security Doors Sectional Doors Secured by Design explained: is it mandatory for doors? Secured by Design vs NPSA vs LPCB: Which One You Need Security Door Locks Security Door Maintenance Checklist Security Doors and Access for Everyone: What Approved Document M Asks Security Doors for A and E Departments Security Doors for Badminton Clubs Security Doors for Bowling Alleys Security Doors for Bowls Clubs Security Doors for Climbing Centres Security Doors for Cricket Clubs Security Doors for Dialysis Centres Security Doors for Golf Clubs Security Doors for Hockey Clubs Security Doors for Ice Rinks Security Doors for Maternity Units Security Doors for Mental Health Units Security Doors for Oncology Units Security Doors for Operating Theatres Security Doors for Rehabilitation Centres Security Doors for Snooker Clubs Security Doors for Squash Clubs Security Doors for Swimming Pools Security Doors for Tennis Clubs Security Doors for Walk-in Centres Security Doors West Midlands Explained Security Fencing Security Gates Cost Factors Explained Security shutters vs high performance roller doors Security shutters vs retractable grilles: which suits retail and commercial openings? Security Turnstiles Explained Security Window Film Security Windows for Schools Explained Self Storage Security Doors Server Room Doors Explained Shopping Centre Security Doors Smoke Control Doors Explained Smoke Curtains Specification Mistakes When Mixing LPS 1175, PAS 24 and SBD in One Tender SR2 vs SR3 vs SR4 security doors: choosing the right LPS 1175 level Stadium Security Doors Steel Door Frames Steel vs aluminium security doors: strength, ratings and looks Steel vs timber fire doors: which suits your building? Student Accommodation Security Doors Substation doors: security, ventilation and specification Supermarket Security Doors Telescopic Bollards Tender Evaluation Criteria and Scoring for Security Doors and HVM The Scope of a Maintenance Contract for Security Doors and Barriers Theatre Security Doors Thermal and Weather Performance of External Security Doorsets Thermally broken steel security doors: U-values and certification Traffic Calming as Hostile Vehicle Mitigation Transport hub security requirements Turnstile Cost Factors Explained Turnstile vs speed gate vs security portal: choosing entrance control Types of security doors for commercial buildings University Security Doors Explained Vehicle Dynamics Assessment: What It Tells the Buyer Before a Barrier Is Specified Warehouse Security Doors Explained Warehouse Security Gates Warranty, Defects Liability and Guarantees for Security Doors and Barriers What affects the cost of a bullet resistant door What affects the cost of a high-security door in the UK Window Security Bars View all →

Products

One supplier for the whole building envelope

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.