Fire Door Rules for Ice Rinks
An ice rink moves crowds in skates past hire desks, lockers and a cafe, so each door takes the fire period its room demands, FD30 out front and FD60 behind.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
An ice rink holds a rink hall, a cafe, locker rooms and a skate hire desk beside the ice, and the fire rules follow the rooms behind each leaf. Skaters eat in the cafe, change in the locker rooms and hire skates at the desk, while the staff office and the plant room sit behind leaves the skaters never pass. People leave in skates and move slowly, so the leaves on the way out matter as much as the leaves that hold flame back.
EN 1634-1 gives the minutes on a rink leaf, testing it against fire and counting how long it holds. A leaf marked FD30 holds for thirty minutes and a leaf marked FD60 for sixty, and the letter after the minutes names what the leaf stopped, E for flame on its own, EW for flame with part of the heat, and EI for flame with the heat as well.
An ice rink is not a leisure centre, because one rink hall takes the place of sports halls and pools, and it is not a bowling alley, because the rink hall and the skate hire desk take the place of lanes and shoe hire. The fire door rules for leisure centres name the rules for a building full of sports halls, and the fire door rules for bowling alleys name the rooms a hall of lanes keeps behind its public floor.
- FD30 / FD60Periods to EN 1634-1
- Cafe and rink hallWhere skaters eat and skate
- Sa / S200Smoke ratings from BS EN 1634-3
- One listEvery rink door named
Eight openings in an ice rink: a period beside each room
Eight openings make up the rink order, and the period follows what each room holds. Skaters come in through the entrance, hire at the desk, eat in the cafe and change in the locker rooms, while the first aid room holds the kit for a fall, the staff office holds the takings and the records, and the plant room keeps the ice cold.
The staff office and the plant room take FD60, because the records and the ice plant behind them ask for sixty minutes. The entrance, the skate hire desk, the locker rooms, the cafe, the rink hall and the first aid room take FD30, because the skaters on that route can reach the car park in less than thirty minutes.
Every opening gets a line of its own with leaf and period written beside the room, and the table below puts the eight rooms beside their periods and grades.
| Room | Period | Grade | What to check |
|---|---|---|---|
| Entrance | FD30 | B3 | Leaf, glass, closer |
| Skate hire desk | FD30 | B3 | Leaf, glass, closer |
| Locker rooms | FD30 | B3 | Leaf, lock, seals |
| Cafe | FD30 | B3 | Leaf, glass, closer |
| Rink hall | FD30 | B3 | Leaf, lock, closer |
| First aid room | FD30 | B3 | Leaf, lock, seals |
| Staff office | FD60 | C5 | Leaf, lock, seals |
| Plant room | FD60 | C5 | Leaf, lock, seals |
Fire minutes from EN 1634-1 can sit beside a forced entry grade from LPS 1175 Issue 8.2 of September 2024 on the same doorset, so one report names both proofs. How the pair is proved on a single leaf is shown in the dual certification guide for fire and security doors.
Sixty minutes behind shut leaves: FD60 in the staff office and plant room
The period belongs to the whole doorset and not to the leaf alone, so the leaf, the frame, the fixings and the lock are proved together and the report states the period they hold. The fire door certification guide names what the report behind a period must hold.
FD60 sits on the staff office leaf, which stays shut whenever no one is working behind it, because the takings and the records in that room are what the rink runs on. The room asks for sixty minutes, because flame reaching it takes the papers the rink cannot do without.
The plant room fire doors guide sets out what the plant room leaves must do, and the plant room door requirements guide names the doors that guard the plant.
Thirty minutes on the way out: FD30 from rink hall to car park
FD30 sits on the rink hall leaf, the locker room leaves, the cafe leaf and the entrance leaf, because skaters skate in the hall, change in the locker rooms, eat in the cafe and reach the car park through the entrance. Thirty minutes is more than the skaters need, and the route to the car park is short.
Where the route serves skaters who move slowly in boots, a push bar proved to BS EN 1125 sits on each leaf on the way out, because more than 60 people may crowd the route at once, and the bar spans no less than 60 percent of the leaf, so a skater who reaches it opens it with one push. The panic hardware guide sets out what the bar must do when skaters push against the leaf, and the emergency exit doors guide covers the leaves on the way out.
A glazed panel in the cafe leaf lets staff watch the skaters without opening the leaf, and the pane is proved with the leaf round it, glass, bead and fixings named in the report. The fire door vision panels guide names the panels a fire leaf may carry.
Smoke before flame: Sa and S200 along the rink corridor
Skaters leaving the rink hall meet smoke before they meet flame, so the leaves on the way out carry a smoke rating beside the period. BS EN 1634-3 gives the two smoke ratings, Sa for smoke at room temperature and S200 for smoke at 200 degrees, and the smoke control doors guide works through how the route leaves keep smoke back while skaters move past them.
A leaf that must stay open through the day hangs on a hold-open device proved to BS EN 1155, which lets it go on its own the moment the alarm sounds. The fire compartmentation guide names how the leaves hold the line between one part of the rink and the next, and a chair wedged under a leaf leaves it with no period while it stands open.
Smoke spreads along a corridor faster than skaters walk in boots, so the leaves between the rink hall and the entrance matter most. A leaf that closes on its own after each person through holds the smoke on one side of it.
Closers, seals and gaps on ice rink doors: what the period rests on
An FD60 leaf holds its hour only when the closer shuts it, the seals meet the frame and the gaps stay narrow, because flame passes through a leaf left ajar in seconds and through a wide gap soon after. BS EN 1154 runs closer power from EN 1, for a leaf 750 mm wide and 20 kg, to EN 7, for a leaf 1,600 mm wide and 160 kg, and a fire door closer is never below EN 3.
Once the heat reaches 200 to 250 degrees the seal grows in its groove and closes the gap, so flame and hot gas find no way through, while paint on the seal keeps it from growing. The 4 mm gap round a hung leaf is checked with a gauge on the monthly round. The intumescent seals guide covers how the seal is fitted, the fire door closers guide covers what the closer must do, and the fire door gaps guide covers how the gaps are measured.
Hinges proved to BS EN 1935 run through 200,000 cycles, grade 13 rated for 120 kg and grade 14 for 160 kg, so the heavier leaf is hung on the heavier hinge. BS 8300 with Approved Document M caps the push at 30 N through the first 30 degrees and at 22.5 N once the leaf has passed them, so a skater can open the leaf without help. The fire door signage guide names the signs each leaf must carry.
Moving skaters out in boots: the route the rink rehearses
The route to the car park is signed at every turn, because the alarm may sound while a visitor who has never used the building sits in the cafe. The route stays clear day and night, and the entrance leaf opens to one push from whoever reaches it first, with the power on or off.
Martyns Law sorts a venue by the number of people it holds, with one tier covering 200 to 799 people and a higher tier starting at 800, after Royal Assent in April 2025 and a go-live expected in spring 2027. What each tier asks for is set out in the Martyns Law guide for premises, and a rink holding 200 or more people falls in a tier it covers.
Bollards beside the car park keep vehicles clear of the way to the entrance, and ProtectUK caps the clear gap between them at 1,200 mm and sets their height at no less than 500 mm. How the bollards are chosen is covered in the choosing HVM bollards guide.
The cafe leaf and the first aid leaf: FD30 where skaters rest and recover
The cafe leaf takes FD30, because skaters eat and drink in the cafe between sessions and the route out runs through it. Thirty minutes is the hold that room asks for, because the cafe clears fast once the alarm sounds.
The first aid room leaf takes FD30 as well, because the kit for a fall on the ice sits behind it and the room must stay shut between uses. A skater hurt on the ice is carried to the first aid room through the rink hall leaf, so the leaves on that short route matter as much as the leaves on the way out.
A cafe in a restaurant asks for the same period on its leaves, as the fire door rules for restaurants show.
Placing the ice rink fire door order: period, grade and proof on one line
Every opening gets a line of its own on the order, with leaf, period, lock and closer written beside it. A leaf named once for the whole rink leaves the fitter to guess.
Each leaf on the order is checked before it is signed, because a closer ordered after the doorset arrives holds the job up, and a leaf with no line beside it cannot be checked on arrival. The how to specify security doors guide names what the order must hold.
Once the rink opens, the manager goes round with the door list and tries each leaf in turn, because a leaf that sticks after the overnight freeze will not shut when the hall fills. A leaf that drags, a closer that holds a leaf ajar, and a seal that has lifted from its groove are marked beside their own rooms before the first session starts. The fire door inspection checklist sets out the faults to watch for on the round, and the fire door maintenance guide covers the routine that keeps each leaf shutting flat against its frame.
Write the period, the grade and the closer on one line for each leaf, and check the line against the room before any leaf is hung.
What period should an ice rink plant room door carry?
FD60 to EN 1634-1, because the plant room holds the ice plant, and an hour is the hold that room demands.
What period should an ice rink entrance door carry?
FD30 to EN 1634-1, because the entrance is the way out and the route to the car park takes less than half an hour.
Can an ice rink leaf hold a fire period and a security grade?
Yes, when one doorset passes both the fire test and the forced entry test, a single report gives the period and the grade for that leaf.
Do ice rink fire doors need a smoke rating?
Yes, the leaves on the route carry Sa or S200 to BS EN 1634-3 beside their period, because skaters meet smoke before flame.
What happens when a fire door will not shut?
A leaf that will not shut is written up against its own door the day the fault is found, and the rink does not wait for the next look round.