Fire rated glass has no standard price. The quote turns on the class, the fire period, the glass type and the layers inside the pane, the size and shape of each pane, the frame and beads that hold it, any added ratings, and the handling on site. Each factor moves the quote in one direction, and the sections below follow that order, largest movement first. No figures are given here, because a figure without the full specification behind it would mislead; what matters is which factors move the quote and by how much relative to each other.

The first thing to fix is what the rating belongs to. A pane of fire glass has no rating on its own that transfers to any door or screen. The rating was earned by one assembly in a furnace: one leaf or frame, one glass type, one bead system, one aperture size, one set of seals. The test evidence names all of them together, and the assembly on site must match that list. Our fire rated glazed doors page works through that assembly in full, and our bullet resistant glass cost guide follows the same factors-only discipline for a different kind of pane.

  • E, EW and EIIntegrity, radiation and insulation under EN 1634-1
  • 30 to 120 minutesFire resistance periods for glazed doorsets
  • Four glass typesWired, ceramic, intumescent laminated and gel-filled
  • One tested assemblyGlass, beads, frame and seals tested together

The class sets the quote: E, EW and EI

For the pane, the three letters describe what the glass holds back, and the letter is the largest single step in the quote. E means integrity: the pane stops flames and hot gases passing through for the stated minutes. The glass on the safe side can still become hot enough to burn, so E suits positions where nobody needs to stand close to the pane and nothing combustible sits against it.

EW adds a limit on radiated heat: the heat passing through the pane stays below a threshold, so a person can stand near the glass without being driven back by the heat. The build grows to meet that limit, and the frame must carry the extra layers. EI adds insulation: the temperature rise on the unexposed face is limited, to an average of 140 degrees Celsius and a maximum of 180 degrees Celsius above ambient, so the safe side of the pane stays cool enough to touch. That is the most demanding build of the three, and it is what escape routes and compartment walls usually demand, because people escape past the door and may need to put a hand on it.

The letter follows the position of the opening, not the preference of the buyer. A vision panel in a corridor door on an escape route needs EI where people pass close to it, while a pane in a store wall between two low-risk rooms may only need E. The fire strategy sets the letter and the minutes for each opening, and the door schedule turns it into an order. Do not upgrade or downgrade the letter on site without the fire engineer agreeing, because the glass type changes with it and the frame may need to change too. Our fire ratings page sets out the three letters and the periods behind them.

The minutes that matter: 30, 60, 90 and 120

After the class, the fire period is the next step in the quote. Fire rated glazed doors are supplied from EI30 to EI120, and the period is the minutes the assembly holds its classification in the furnace test to EN 1634-1. Each step up the scale adds material. A longer period needs more layers in the pane, which makes it thicker and heavier, and the weight then has to be carried by the frame, the beads and the wall around it.

Reaching EI120 needs a multi-layer unit, and that weight changes the whole doorset. A slim frame that suits a 30-minute pane will not carry a 120-minute unit, and a closer sized for a solid leaf will not close a heavy glazed leaf reliably. The glass type, the period and the frame are one decision, not three, and the test evidence is the place where they meet. For the steel doorset the glazing sits in, see our fire rated steel doors page, and for the leaf that carries the glass on a track, see our fire rated sliding doors guide.

Read the period as a minimum set by the fire strategy, not as a target to beat. A pane ordered a period above the assessed need carries layers the project does not need, and the extra weight then has to be carried by everything around it. The 90 and 120 minute periods belong to compartment walls and high-risk openings, where the fire strategy demands the longest hold. Buy the period the strategy names, and spend the difference on the frame and the evidence rather than on minutes nobody asked for.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Four glass types, four build-ups

Four glass types do this work, and each does it in a different way. Georgian wired glass is the oldest: a wire mesh cast into the pane holds the fragments in place when the glass cracks, so the pane keeps its integrity even though it is no longer clear.

Ceramic glass, also called borosilicate glass, is a clear pane that holds its integrity at high temperature without a mesh, so it suits vision panels where a clear view matters. It keeps its shape as one face heats, and it does so without the wire that marks the older type. Intumescent laminated glass carries a clear interlayer that expands in heat into an opaque insulating barrier, which is what gives a glazed door its EI rating. The interlayer is the part that does the insulating work, and it is the reason an EI pane is thicker and heavier than an E pane of the same size. Gel-filled glass units use a gel layer between panes that absorbs heat and holds the pane together, and they suit full-height glazing where a thick unit is acceptable.

The type follows the class and the period, not the look of the pane. A clear pane is not automatically the right pane, and a pane chosen for its appearance without its class behind it has no rating to check. Ask for the test report that states the standard, the class and the period for the exact glass build being bought, not a thinner or older version of it. For how steel and timber leaves carry these panes differently, see our steel versus timber fire doors guide.

Big panes, small panes and awkward shapes

Size moves the quote because every extra area of pane is extra laminated material. A large glazed screen uses far more material than a small vision panel, and the weight grows with the area, so the frame, the beads and the handling all grow with it. Keep the glazed area honest: a window that is mostly glass needs a mostly glazed design, with a frame and fixings sized for the load from the start, not a standard frame asked to carry a pane it was never meant to hold.

Shape moves the quote too. A rectangular pane cuts cleanly and fits a standard bead system. A shaped pane, a pane with a cut-out for a handle or a lock, or a pane that must fit an opening that is not square, needs special cutting and a bead system that follows the edge. Every hole and every notch in a fire pane is a point the test evidence must cover, because a cut made after the test changes the pane the test described. Name every cut-out and every fixing hole in the order, and check that the evidence covers them.

Vision panels deserve a word of their own. A small vision panel in a fire door is the cheapest way to put glass in a rated doorset, because the pane is small, the build is simple and the frame barely notices the weight. A full-height glazed screen is the dearest, because the pane is large, the build is multi-layer, and the frame must carry a unit that weighs as much as a leaf. Where the opening needs a view and nothing more, keep the pane small.

Thickness, layers and the weight the frame must carry

When heat reaches the pane, the layers inside it do the work. In an intumescent laminated pane the interlayers expand and form the insulating barrier; in a gel-filled unit the gel absorbs the heat; in a wired pane the mesh holds the fragments. Each step up the class or the period adds layers, so the pane grows thicker and heavier, and the weight is what is felt on site. A high-period pane needs a deeper frame, stronger beads and careful handling, and large sizes may need mechanical lifting and a frame designed for the load from the start.

Never select by thickness alone. Two panes of the same thickness can carry different classes, because the rating comes from the test, not the millimetres. The make-up of the layers decides the class, and the test report is the proof. Buy the test evidence, not the dimension, and ask for the report that states the standard, the class and the period for the exact glass build being bought. A pane that is thicker than the evidence names is a pane outside its evidence, just as surely as a pane that is thinner.

Weight is the quiet cost in the quote. It decides the frame depth, the hinge grade, the closer size and the fixings into the wall, and each of those is priced with the pane rather than after it. A glazed leaf that is heavier than the closer can close will not latch, and a door that does not latch has no fire performance at all. Size the whole doorset for the weight of the glass, and check the closer and the hinges against the same evidence. For the duties the law places on the person responsible for the door, see our fire door regulations for commercial buildings guide.

What holds the pane: framing, beads and seals

The beads are the retention system for the pane, and they do more work than they look capable of. Steel beads, fixed to the pattern in the test evidence, hold the glass in the opening as the frame heats and moves. The fixings matter as much as the bead: pins or screws set to the wrong spacing, or a bead swapped on site for a neater looking one, takes the doorset outside its evidence. In the furnace the glass is the part under the most stress. One face heats fast while the other stays cool, the pane expands, the frame moves, and the beads must hold the glass in the opening while all of it happens. A failure at the edge of the pane counts as a failure of the door, because flame and hot gas pass through the gap just as they would through a gap in the leaf.

The frame is part of the same decision. A steel frame carries a heavy multi-layer unit without complaint, and it suits the long periods and the large panes. A timber frame can carry a fire pane too, but the leaf and the frame must be the ones in the test evidence together, and the period the timber frame can carry may be shorter than the period the glass alone could reach. The frame material, the bead system, the glazing tape and the seals are all named on the evidence beside the glass itself, and a change to any one of them is a change to the tested assembly.

Seals sit beside the beads in the evidence. Intumescent seals around the leaf close the gap to the frame in a fire, and the glazing tape or gasket around the pane keeps the glass seated as it heats. Paint over an intumescent seal and it cannot expand when heat reaches it, so tell the decorators that the seals are never to be coated. Check the beads and the seals at every inspection: a bead that has loosened, a seal that has shrunk or a tape that has fallen out of its groove is a failed check. For the checks themselves, see our fire door inspection checklist.

When one pane must do two jobs

Some openings ask the glass to do more than hold back fire. A pane in a cash office may need to resist forced entry as well, a pane in a control room may need to resist blast, and a pane between a noisy plant room and an office may need to cut sound. Each added rating adds layers to the build, and each one needs its own test on the same construction. A pane with fire evidence and no forced entry evidence has shown nothing about attack, and a pane with ballistic evidence and no fire evidence has shown nothing about heat.

Forced entry is the commonest second job. A pane that must resist attack is tested to LPS 1175, and the rating that applies to the doorset is the one the whole assembly earned together. Our LPS 1175 page sets out the ratings, and our dual certification guide works through how fire and security sit on one doorset. Where the threat assessment names forced entry as well as fire, ask for both certificates against one identical specification, and check that the glass build, the beads and the frame are the same on both.

Ballistic is the dearest second job, because the build-up changes most. Bullet resistant glass is a sandwich of glass layers bonded with interlayers, and the BR class from EN 1063 sets the baseline, from BR1 to BR7, with SG1 and SG2 for shotgun and the S and NS suffixes for spall on the protected face. A pane that must be both fire rated and bullet resistant carries the layers for both jobs, and the test evidence must name both. Our bullet resistant glass cost guide sets out the factors for that pane, and our bullet resistant glass page covers the product itself. Blast and acoustic ratings follow the same rule: one build, one set of tests, one piece of evidence that names them all. Where the opening needs only fire performance, do not buy the second job with it.

Delivery, handling and the years after fitting

The last factor in the quote is the one that arrives after the pane is made. Large fire panes are heavy, and the handling on site decides whether the pane arrives whole. A pane that must travel to an upper floor, through a narrow corridor or into a live building needs lifting plans, protection and sometimes phased working, and none of those appear in the pane price. Ask how the pane will be lifted, stored and fitted before the order is placed, and name who carries the risk if a pane breaks on the way in.

Storage matters as much as lifting. A pane left standing on a bare edge, leaning against a wall without protection, or stored where trolleys and forklifts pass, is a pane that may never be fitted. Fire glass must be stored flat or on a proper rack, with its edges protected and its faces kept clean, and the interlayers kept away from damp and from heat. A pane that arrives with a chipped edge or a damaged interlayer is a pane to reject, not a pane to fit and hope about, because the edge is where the pane fails first in the furnace.

Life after fitting is the quietest cost of all. A glazed doorset that is never checked drifts out of its tested state: beads loosen, seals harden, a closer is adjusted by hand and the leaf stops latching. Name the inspection routine in the handover pack, and keep the test evidence with the building records so the next inspection has something to check the door against. When a pane must be replaced, the replacement must match the original build exactly: the same glass type, the same layers, the same class and the same period, with the same beads and the same seals. A replacement pane ordered by size alone, without the build behind it, is a pane with no rating to check. For the servicing that keeps a doorset working, see our maintenance page, and for writing the schedule so these decisions are made once, see our how to specify security doors guide. For the same discipline on other products, see our bullet resistant door cost factors guide and our roller shutter cost factors guide.

Class What it holds back Where it belongs What it does to the build
E Flames and hot gases Positions where nobody stands close to the pane Lightest build, least demanding on the frame
EW Flames, hot gases and radiated heat Positions where people pass near the glass Heavier build, frame must carry extra layers
EI Flames, hot gases and heat, with insulation Escape routes and compartment walls Most demanding build, multi-layer unit

Buy the test evidence, not the pane. A pane with no evidence for the doorset it sits in has no rating to check.

Why does EI glass cost more than E glass?

EI adds insulation to integrity, so the pane needs an interlayer or a gel layer that holds the temperature rise on the safe side to an average of 140 degrees Celsius and a maximum of 180 degrees Celsius above ambient. That build is thicker and heavier, and the frame, beads and hinges must carry the extra weight, so the whole doorset moves with the pane.

Can I order a higher class or a longer period than the fire strategy asks for?

Yes, but the extra build is money spent on performance nobody asked for, and the extra weight has to be carried by the frame and the fixings. Never order a lower class or a shorter period than the strategy names, and never change the letter or the minutes on site without the fire engineer agreeing.

Does a thicker pane always mean a longer fire rating?

No. Two panes of the same thickness can carry different classes, because the rating comes from the test, not the millimetres. The make-up of the layers decides the class, and the test report is the proof. Ask for the report that states the standard, the class and the period for the exact glass build being bought.

What happens if the beads are changed on site?

The doorset leaves its test evidence behind. The bead system and its fixings are named on the evidence beside the glass itself, and a bead swapped for a neater looking one takes the doorset outside the evidence. Replace beads only with the type and fixing pattern the evidence names.

Can one pane be both fire rated and bullet resistant?

Yes, with combined evidence. The pane carries the layers for both jobs, and the test evidence must name both the fire class and the BR class from EN 1063 on the same build. Ask for both certificates against one identical specification, and check that the glass, the beads and the frame are the same on both.

What a glass quote should include

A glass quote is not one figure. It is a list of parts that have to arrive together, and a quote that names only the pane leaves the rest to be found later. Ask for each item by name before the order is placed.

Start with the pane itself, with its class and minutes. E, EW and EI are different build-ups, and FD30 and FD60 are different thicknesses and weights. A pane quoted as fire rated glass, with no class and no minutes, is a pane nobody can check. Ask for the class, the minutes and the test evidence in writing.

The frame, beads and seals that hold it. The glass is only as good as the assembly around it, and the beads and seals in the quote must be the ones the test evidence names. Intumescent seals expand at roughly 200 to 250 degrees, and a seal that is not in the evidence is a seal that cannot be proved. Check the frame can carry the weight of the pane, because a thick EI pane is heavy.

The size and the shape. Big panes cost more to make, move and fit than small ones, and an awkward shape or a pane that must be cut to fit a listed opening adds time at every step. A pane that is too big for the frame, or a frame that must be rebuilt to take the pane, turns one order into two. Measure the opening before the quote is written, and ask what the largest pane the frame can take is.

Delivery, handling and fitting. Large panes need specialist handling, and a pane that arrives cracked or chipped is a pane that cannot be fitted. Delivery to site, safe storage before fitting, and the fitter who knows how to glaze a fire rated pane are all part of the quote, not extras to be added after. Our fire rated sliding doors guide sets out the same discipline for a leaf on a track.

The evidence and the years after. The test report and the classification should arrive with the pane, and the quote should name the inspection routine the building will follow. A pane with no evidence is a pane nobody can speak for, and a building that loses the evidence has glazing it cannot prove.

Mistakes that push a glass order over budget

Most glass orders go over budget in small ways. Check each point before the order is placed.

  • Accepting a quote that names the pane but not the class and minutes.
  • Ordering a pane the frame cannot carry.
  • Fitting beads or seals that are not in the test evidence.
  • Painting over intumescent seals, which stops them expanding in a fire.
  • Ordering one large pane where two smaller panes would fit the frame.
  • Losing the test report before the building is handed over.

Keep the evidence with the glazing. The test report, the classification and the glazing schedule should sit with the building records, so the next inspection has something to check each pane against. For the glazed doors the same glass goes into, see our fire rated glazed doors page.

Specifying fire rated glass for a project?Send the class, the period and the pane sizes for a tested assembly quotation.
Get a free quote

Related

More in guides for specifiers

10 mistakes when specifying certified security doors 10 steps to specify an LPS 1175 door Acceptance and Snagging of a Security Door or Barrier Job Access Control Doors Acoustic Doors: Ratings and Specification After a Forced Entry Attempt: Checking a Security Door Airport Security Doors Anti-Ligature Doors for Mental Health Wards Anti-Ram Bollards Anti-ram gates and barriers: protecting vehicle entrances Arcade Security Doors Explained Automatic Doors Automatic Gates Cost Factors Automatic Vehicle Barriers Ballistic Panels Bank Security Doors Bingo Hall Security Doors Explained Blast doors: glazed vs solid and how they are rated Blast protection window film: what it does and what it cannot do Blast resistant windows: what drives the cost and how to specify them Bollard Cost Factors Explained Bollard regulations in the UK: spacing, height and depth Bookmaker Security Doors Explained Builders Merchant Security Doors Bullet Resistant Glass Cost Factors Bullet resistant glass ratings explained: BR1 to BR7 and SG classes Bullet resistant vs bulletproof glass: what the difference means Buying Security Doors and HVM Through Public Frameworks Car Park Security Doors Explained Car Showroom Security Doors Casino Security Doors Explained CDM 2015 Duties When Security Doors, Shutters or HVM Are Installed Cinema Security Doors Cleanroom Doors Cold Store Doors College Security Doors Commissioning, Handover and the O&M Manual for Security Doors and HVM Communal entrance doors for flats: Secured by Design and what to specify Community Centre Security Doors Control Room Doors Court Security Doors Crash Rated Fences and HVM Fencing Explained Data centre physical security: doors, glazing, HVM and shielding by zone Dental Practice Security Doors Depot Security Doors Explained Door Entry Systems Due Diligence When Selecting Vehicle Security Barriers Emergency Exit Doors EMP Shielding Cost Factors Explained Exhibition Centre Fire Door Rules Exhibition Centre Security Doors Factory Security Doors Faraday cage vs RF shielded room: what a business needs FB4 vs FB6 vs FB7: how to choose a ballistic rating Fire and security doors: how dual certification works Fire Compartmentation Fire Curtains Fire Door Certification Fire Door Closers Explained Fire Door Cost Factors Fire Door Duties of the Accountable Person Fire Door Gaps Fire Door Hardware Explained Fire door inspection checklist for steel and timber doors Fire Door Maintenance Fire Door Regulations Care Homes Fire Door Regulations for A and E Departments Fire Door Regulations for Airports Explained Fire Door Regulations for Bowls Clubs Fire door regulations for commercial buildings in the UK Fire Door Regulations for Dialysis Centres Fire Door Regulations for Hockey Clubs Fire Door Regulations for Hospitals Explained Fire Door Regulations for Offices Explained Fire Door Regulations for Operating Theatres Fire Door Regulations for Retail Explained Fire Door Regulations for Schools Explained Fire Door Regulations for Snooker Clubs Fire Door Regulations for Stadiums Fire Door Regulations for Student Accommodation Fire Door Regulations for Warehouses Fire Door Regulations Leisure Centres Fire Door Regulations Restaurants Fire Door Remediation Programme for Housing Providers Fire Door Rules for Badminton Clubs Fire Door Rules for Bingo Halls Fire Door Rules for Bookmakers Fire Door Rules for Bowling Alleys Fire Door Rules for Car Parks Fire Door Rules for Car Showrooms Fire Door Rules for Cinemas Fire Door Rules for Climbing Centres Fire Door Rules for Colleges Fire Door Rules for Community Centres Fire Door Rules for Cricket Clubs Fire Door Rules for Dental Practices Fire Door Rules for Depots Explained Fire Door Rules for Golf Clubs Fire Door Rules for GP Surgeries Fire Door Rules for Gyms Explained Fire Door Rules for Ice Rinks Fire Door Rules for Maternity Units Fire Door Rules for Mental Health Units Fire Door Rules for Museums Fire Door Rules for Oncology Units Fire Door Rules for Opticians Fire Door Rules for Pawnbrokers Fire Door Rules for Petrol Stations Fire Door Rules for Pharmacies Fire Door Rules for Ports Fire Door Rules for Post Offices Fire Door Rules for Prisons Fire Door Rules for Rehabilitation Centres Fire Door Rules for Self Storage Fire Door Rules for Shopping Centres Fire Door Rules for Squash Clubs Fire Door Rules for Supermarkets Fire Door Rules for Swimming Pools Fire Door Rules for Tennis Clubs Fire Door Rules for Theatres Fire Door Rules for UK Arcades Fire Door Rules for UK Casinos Fire Door Rules for UK Hospices Fire Door Rules for Walk-in Centres Fire Door Signage Fire Door Vision Panels Fire Doors and Gateway 2 in Higher-Risk Buildings Fire Rated Sliding Doors Explained Fire Rated Windows Cost Factors Fire Rated Windows Explained Fire Safety Enforcement Notices and Fire Doors: What the Responsible Person Must Do Flat Entrance Doors: PAS 24 and Fire Rated Forced Entry vs Ballistic vs Blast: Which Rating a Site Needs Garage Security Doors Explained Gate Automation Explained Golden Thread Records for Fire Doors GP Surgery Security Doors Explained Gym Security Doors Explained High Speed Doors HMO Fire Doors Hospice Security Doors Explained Hospital Security Doors: Wards, A&E, Plant Hospital Security Gates Hotel Fire Doors Hotel Security Doors How to choose HVM bollards: fixed, shallow mount, removable and automatic How to keep an LPS 1175 door rating valid after installation How to Specify Fire Doors in a Housing Tender How to specify security doors: a checklist for architects How to Verify a Secured by Design Listing How to Verify an LPS 1175 Certificate on Red Book Live How to Write an Operational Requirement for Physical Security HVM planters and street furniture: protection that blends in In-Service Care of Vehicle Security Barriers Installation Handover: LPS 1175 Doors and PAS 68 Barriers Intumescent Seals ISO 16933 explained: EXV and SB classes and hazard ratings ISO 22343 vehicle security barriers explained Keeping a Dual-Certified Fire and Security Door Valid in Service Laboratory Security Doors Layered Security for a Site: Deter, Detect, Delay, Mitigate, Respond Lead Times and Programme Risks for LPS 1175 Doors Leisure Centre Security Doors Library Security Doors Listed Building Fire Doors Loading Bay Doors Explained Lockdown and Access Control Hardware on an LPS 1175 Door LPS 1175 Gates and Grilles Explained LPS 1175 Issue 8 explained: from SR1 to SR8 to A1 to H20 LPS 1175 Roller Shutters LPS 1175 vs ASTM F2781 and Other US Ratings Explained LPS 1175 vs EN 1627: how UK and European burglar resistance ratings compare LPS 1175 vs PAS 24: which security standard does your door need? LPS 1175 Windows and Walling Explained Martyn’s Law and Places of Worship: What a Buyer Checks for Doors and Entry Control Martyn’s Law Enhanced Tier: Physical Measures and the Specifier Brief Martyn’s Law Standard Tier: Procedures, Doors and Shutters Martyn’s Law Timeline and the SIA Regulator Martyn’s Law: what premises must do and which physical measures to consider Master Key Systems MRI and RF shielded rooms: how they work and what to specify Museum Security Doors NPSA Catalogue of Security Equipment (CSE) Explained NPSA Forced Entry and Blast Guidance for Government Sites NPSA Guidance on Lockdown and Marauding Attack: What It Asks of Doors and Entrances Office Security Doors Optician Security Doors Explained Panic Hardware PAS 24 requirements for doors and windows explained PAS 68 Bollard Foundations Explained PAS 68 bollards: ratings, spacing and cost factors PAS 68 vs IWA 14 vs ISO 22343: hostile vehicle mitigation standards explained Pawnbroker Security Doors Explained Pedestrian Gates Petrol Station Security Doors Pharmacy Security Doors Planning Permission for Security Shutters, Gates and Bollards on Commercial Premises Plant room doors: fire, security and ventilation requirements Plant Room Fire Doors Port Security Doors Post Office Security Doors Explained Powder coating vs galvanising vs paint for steel Preliminary Market Engagement for Security Doors and HVM Prison Security Doors Programming a Security Door and Barrier Package on a Live Site Public-Sector Tender Response Checklist for Security Door and HVM Supply Reading a PAS 24 and SBD Door Test Report Regulation 38 Fire Safety Information at Handover for Fire-Rated Security Doorsets Replacing Security Doors in an Occupied Building Restaurant Security Doors Retail Security Doors Revolving Doors RF shielding standards and how shielded rooms are tested Rising Bollard Cost Factors Road Blocker Cost Factors Explained Road Blockers Explained Roller Shutter Cost Factors: What Drives the Price Roller shutter regulations in the UK: safety and maintenance Safe room and panic room doors: specification basics Safety Duties for Powered Doors, Gates and Barriers on Commercial Sites School Security Doors Sectional Doors Secured by Design explained: is it mandatory for doors? Secured by Design vs NPSA vs LPCB: Which One You Need Security Door Locks Security Door Maintenance Checklist Security Doors and Access for Everyone: What Approved Document M Asks Security Doors for A and E Departments Security Doors for Badminton Clubs Security Doors for Bowling Alleys Security Doors for Bowls Clubs Security Doors for Climbing Centres Security Doors for Cricket Clubs Security Doors for Dialysis Centres Security Doors for Golf Clubs Security Doors for Hockey Clubs Security Doors for Ice Rinks Security Doors for Maternity Units Security Doors for Mental Health Units Security Doors for Oncology Units Security Doors for Operating Theatres Security Doors for Rehabilitation Centres Security Doors for Snooker Clubs Security Doors for Squash Clubs Security Doors for Swimming Pools Security Doors for Tennis Clubs Security Doors for Walk-in Centres Security Doors West Midlands Explained Security Fencing Security Gates Cost Factors Explained Security shutters vs high performance roller doors Security shutters vs retractable grilles: which suits retail and commercial openings? Security Turnstiles Explained Security Window Film Security Windows for Schools Explained Self Storage Security Doors Server Room Doors Explained Shopping Centre Security Doors Smoke Control Doors Explained Smoke Curtains Specification Mistakes When Mixing LPS 1175, PAS 24 and SBD in One Tender SR2 vs SR3 vs SR4 security doors: choosing the right LPS 1175 level Stadium Security Doors Steel Door Frames Steel vs aluminium security doors: strength, ratings and looks Steel vs timber fire doors: which suits your building? Student Accommodation Security Doors Substation doors: security, ventilation and specification Supermarket Security Doors Telescopic Bollards Tender Evaluation Criteria and Scoring for Security Doors and HVM The Scope of a Maintenance Contract for Security Doors and Barriers Theatre Security Doors Thermal and Weather Performance of External Security Doorsets Thermally broken steel security doors: U-values and certification Traffic Calming as Hostile Vehicle Mitigation Transport hub security requirements Turnstile Cost Factors Explained Turnstile vs speed gate vs security portal: choosing entrance control Types of security doors for commercial buildings University Security Doors Explained Vehicle Dynamics Assessment: What It Tells the Buyer Before a Barrier Is Specified Warehouse Security Doors Explained Warehouse Security Gates Warranty, Defects Liability and Guarantees for Security Doors and Barriers What affects the cost of a bullet resistant door What affects the cost of a high-security door in the UK Window Security Bars View all →

Products

One supplier for the whole building envelope

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.