Automatic Doors

Automatic doors for shops, offices and hospitals: sliding and swing operators, safety sensors to EN 12453 and the leaf on fire and escape routes.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed across the UK
Prefer to talk?+44 7352 267239

Get a free project quote

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

An automatic door opens itself when a person reaches it, and shuts itself behind them when they have passed. The operator above the leaf, the sensors that watch the opening and the leaf itself work as one door, so people pass without a hand on the leaf.

The door must open for everyone who should pass and shut behind them, and it must stop when a person stands in its path. The operator, the sensors and the leaf belong on the same line of the order, because the door that arrives must be the door that was proved.

The operators that move a gate leaf are set out in the gate automation guide, and the closer that pulls a manual leaf shut is covered in the fire door closers guide. The types of security doors guide works through the doors that guard each part of a building, so the operator, the sensors and the leaf are named together.

  • EN 12453Safety in use of power operated doors
  • Sliding or swingThe operator that fits the opening
  • Sensors stop the leafPhotocells, edges and loops
  • Fail safeThe door when the power goes

The operator, the sensors and the leaf: what an automatic door is made of

An automatic door is three parts that must agree with each other. The operator drives the leaf, the sensors watch the opening, and the leaf itself carries the weight, the glass and the finish. A leaf that is too heavy for its operator moves slowly and wears the drive, while an operator that is too strong for its leaf slams the leaf against its stops.

The sensor is the part that decides when the leaf moves. A radar sensor above the opening watches the approach and opens the leaf before the person reaches it, a photocell beam across the opening holds the leaf open while a person stands in it, and a safety edge on the leaf stops the leaf when it meets resistance.

The leaf must suit the traffic through the opening. A shop entrance takes a leaf with glass that lets people see through before the leaf opens, an office lobby takes a leaf that matches the doors beside it, and a hospital corridor takes a leaf wide enough for a bed to pass.

How many times a day the leaf must open: matching the drive to the traffic

An automatic door is sold on its drive, and the drive is sold on its duty. A shop entrance opens for every customer through the day, an office lobby peaks in the morning and again in the evening, and a hospital corridor takes a steady stream from morning to night. The count of openings a day decides the drive, because a drive built for light use on a shop front wears early and leaves the leaf slow, noisy and short of its opening.

Ask for the duty in cycles and put the number on the order beside the traffic the entrance must take. A drive that runs all day needs a motor and a gearbox built for that count, and it needs a service interval that matches the count as well, because the rollers, the belt and the sensors wear with every opening. The fire door closers guide covers the closer that pulls a manual leaf shut when no operator drives it. A door that opens a few times an hour takes a lighter drive, and the order should say so, so the entrance does not pay for a drive it never uses.

The hold-open time belongs on the same line as the duty. A leaf that stays open too long lets the heat out of the entrance all day, and a leaf that shuts too soon catches the slow walker halfway through. The security turnstiles guide covers the lane beside the door, where the stream of people is counted before it reaches the leaf, and the revolving doors guide covers the drum that takes the same stream without ever standing open.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Radar opens for everyone, a pad opens for one press, a reader opens for the list

The leaf opens when it is called, and the call decides who passes. A radar sensor above the opening watches the approach and opens the leaf for anyone who walks towards it, so it suits a shop or a public entrance where everyone who reaches the door should pass. A radar sensor suits no door that must stay shut, because it cannot tell a customer from a passer-by.

A push pad calls the leaf only when a person presses it, so it suits a door on a route where the leaf should stay shut until it is wanted, and a pad set at wheelchair height lets a person in a wheelchair call the leaf from where they sit. The force to open a door on the route must stay below 30 N for the first 30 degrees of travel and below 22.5 N beyond, under BS 8300 and Approved Document M, and the pad must sit where a person in a wheelchair can reach it.

A card reader ties the leaf to the access control, so the door opens only for the card holders on the list and the record shows who passed and when. A staff door takes a reader, a public entrance takes radar, and a hospital corridor takes radar with a push pad beside it, so the leaf opens for the bed as readily as for the person on foot. The fire rated sliding doors guide covers the sliding leaves that must also hold fire back, and the security door maintenance checklist sets out the round that keeps the sensors, the operator and the release working. The steel door frames guide covers the frame the leaf hangs in and the fixings that hold it. Send the entrance schedule and the traffic each opening must take, and we will send a tested door price back within one working day.

Call Who it opens for Entrance it suits
Radar Anyone who approaches Shop or public entrance
Push pad Whoever presses it Controlled route, wheelchair height
Card reader Card holders on the list Staff door, recorded entry
Radar and pad Approach or press Hospital corridor, beds and feet

Sliding doors: the leaf that moves along the wall

A sliding door moves its leaf along the wall beside the opening, so the floor in front of the door stays clear. The leaf runs on a track above the opening, and the operator pulls the leaf along the track when the sensor calls for it. A sliding leaf suits an entrance where people walk straight through.

The track must be level and the rollers must run true, because a leaf that drags on its track wears the operator and stops short of the opening. The track, the rollers and the operator belong on the order beside the leaf, so the leaf that arrives covers the opening it was ordered for.

Two sliding leaves can meet in the middle of a wide opening, and each leaf takes its own operator or shares one drive. A wide shop front takes a pair of leaves that part to either side, and the opening between them must be wide enough for the traffic the shop expects.

Swing doors: the leaf that opens on its hinges

A swing door opens its leaf on hinges, like a manual door, and the operator drives the leaf through its arc. The operator sits above the leaf or in the floor below it, and it pushes the leaf open when the sensor calls and pulls it shut when the opening clears. A swing leaf suits an opening where the wall beside it cannot carry a track, because the leaf needs only its hinges and its frame.

The arc of a swing leaf must be clear, because the leaf sweeps across the floor as it opens. A mat, a bin or a queue of people in the arc will meet the leaf, so the safety sensors must watch the arc as well as the opening.

A swing leaf can open in one direction or both, and the direction belongs on the order beside the leaf. A leaf that opens outwards meets the street, while a leaf that opens inwards meets the lobby, and the side the leaf swings to decides where the sensors sit.

Safety in use: EN 12453 and the sensors that stop the leaf

Safety in use of a power operated door is proved to EN 12453, which sets out how a door must behave when a person or a vehicle is in its path. Photocells watch the line the leaf travels, safety edges stop the leaf when they meet resistance, and loops in the ground hold the door open while a vehicle waits. Each device belongs on the order beside the operator, because a door without them is a door that can hurt someone.

The sensors must be tested by breaking the beam and watching the leaf stop, and the test is run on every visit, not only when the door is first fitted. A photocell that has been knocked out of line watches the wrong place, and a safety edge that has hardened with age stops the leaf too late. The security door maintenance checklist names the checks that keep a doorset honest through its life, and the sensors on an automatic door belong on the same round.

Position Door Operator What to check
Shop entrance Sliding leaf Track drive Track, rollers, sensors
Office lobby Swing leaf Overhead drive Hinges, arc, sensors
Hospital corridor Sliding leaf Track drive Width, sensors, release
Back of house Swing leaf Floor drive Hinges, closer, lock
Escape route Swing leaf Manual release Release, hinges, gap

If the sensor stops seeing people, the door must still let them through

An automatic entrance earns its keep by opening for everyone who reaches it, and the sensor is the part that decides. Dust on the sensor face, a bracket knocked out of line by a trolley, or a cable worked loose by years of vibration can each leave the sensor blind, and a blind sensor leaves the entrance shut to the very people it was fitted to admit.

Test the sensor from the approach, not from beside the frame. Walk towards the opening at the pace a visitor would use, from each side, and watch whether the doorset answers before you reach it. A sensor that answers late, or only when you stand close to the frame, is already failing, and the fault is written on the record the same day. The maintenance checklist gives the round in order: sensors first, then the operator, then the release.

Keep a spare sensor of the same type on the shelf, with the bracket and the fixing beside it. A sensor changed on the day it fails costs the building an hour; a sensor ordered after it fails costs the building a week of a shut entrance. The revolving doors guide deals with the drum that takes the same stream of people without ever standing open, and the door entry systems guide deals with the readers that call the doorset for card holders only.

With the power off, the release is the only way through

Every automatic entrance needs a way through when the power goes. The manual release is that way, and it must work by hand, without a key and without force beyond what a person on the route can manage. A release that needs two hands and a shoulder is no release at all, and it will be found out on the night the lights go out, not on the day it was fitted.

Test the release with the power off, not on. Cut the supply, work the release, and push the doorset open by hand from each side, then restore the power and check that the operator takes up the drive again without a fault. The test belongs on the record beside the sensor test, because a release that has seized through months of disuse is as useless as a sensor that has gone blind. Approved Document M and BS 8300 set the limit on the opening force. For the first 30 degrees of travel it stays below 30 N, and beyond that it stays below 22.5 N.

Where the entrance sits on a fire route, the release is part of the escape, not an extra. The doorset must open when the alarm calls it, and the release must still work if the alarm has cut the power. The fire door closers guide deals with the closer that pulls a manual doorset shut when no operator drives it, and the steel door frames guide deals with the frame the doorset hangs in. Send the entrance schedule with the traffic each opening must take, and the enquiry checklist sets out what to send for each opening.

Fault How it shows What to do
Sensor blind Doorset stays shut as people approach Clean the face, check the bracket
Sensor late Answers only at close range Record it, change the sensor
Release seized Will not move by hand with power off Free it, test it, record the test
Operator will not take up Fault after power is restored Call the service visit forward

The push that opens the leaf: BS 8300 and Approved Document M

A person who cannot use the sensor must still get through the door, because the entrance belongs to everyone who reaches it. The force to open a door on the route must stay below 30 N for the first 30 degrees of travel and below 22.5 N beyond, under BS 8300 and Approved Document M.

The manual release beside the leaf must work without power, because the way out matters more than the way in. A leaf that needs power to open is no leaf at all in a blackout, so the release is tested by hand on every visit, with the leaf watched as it opens and shuts. The fire door closers guide sets out the sizes and the fitting of closers, and the leaf that must shut on its own takes a closer that pulls it home every time.

Controls must sit where a person in a wheelchair can reach them, and the panel that calls the leaf must be clear enough to read in the light the entrance actually gets.

Automatic doors on fire and escape routes: the leaf that must still open

A door on an escape route must open when the alarm sounds. The leaf on such a route releases from its operator when the alarm sounds, so the person behind it can push the leaf open with one action. A leaf that stays locked to its operator traps the people behind it.

The leaf on a fire route must also hold fire back for its period, and the operator must not break the proof of the leaf. A fire rated leaf takes an operator that was proved with it, because the leaf, the frame and the operator were proved together, and an operator swapped for another after the test leaves the door different from the one tested. The fire door regulations commercial buildings guide sets out the periods for the shared parts of a public building, and the smoke control doors guide covers the doors that hold smoke back while people move past them.

Hold-open devices that keep a fire leaf open through the day must release the moment the alarm sounds, proved to BS EN 1155, and the release belongs on the schedule beside the door. The fire rated sliding doors guide covers the sliding leaves that must also hold fire back.

Where automatic doors belong: shops, offices and hospitals

Shops take automatic doors at the front, where the stream of customers never stops. A shop entrance takes a sliding leaf with glass, so customers can see through before the leaf opens, and the operator takes the cycle count of the shop, because a leaf that opens for every customer through the day needs a drive rated for that cycle. The fire door regulations retail guide sets out the periods for the shared parts of a shop, and the security turnstiles guide covers the lobby line beside the doors.

Offices take automatic doors at the lobby, where staff, visitors and deliveries all pass through one entrance. An office lobby takes a swing leaf where the wall beside the opening cannot carry a track, and the leaf must open for a person carrying a box as readily as for a person carrying nothing. The fire door regulations offices guide sets out the periods for the shared parts of an office.

Hospitals take automatic doors on the corridors, where beds, trolleys and wheelchairs pass through the day. A hospital corridor takes a leaf wide enough for a bed, and the leaf must shut behind the bed without catching the trolley behind it. The hospital security doors guide works through the doors on a site where staff, patients and visitors all need a different way in.

One schedule for the whole entrance: every operator on one line

Put the automatic door order together as one list, with a line for every entrance on the building and the leaf, the operator, the sensors and the fail position beside each one, so the door that arrives matches the door that was proved. A schedule that names one operator for the whole building leaves the fitter to guess which entrance takes which drive, and a drive fitted to the wrong leaf opens the wrong door.

Check every line of each quotation against the schedule before the order goes out, so no operator, sensor or release is left off the price. Anything left off the quotation still has to be bought. The how to specify security doors guide sets out the columns the schedule needs, and the security door cost factors guide works through what each step up the scale adds to the price.

The round that looks after automatic doors walks every entrance in turn and tests the sensor, the operator and the release on each one. Each fault is written against the door it belongs to on the same day, so the repair follows the fault and the entrance never stands open. The fire door inspection checklist names what each visit should look for, and the automatic door that guards the entrance belongs on the same round.

An automatic door holds only as long as the operator, the sensors and the leaf behind it, so the drive, the safety devices and the fail position must all sit on the same schedule.

What is an automatic door?

A leaf with an operator and sensors that open the leaf when a person reaches it and shut it behind them, with a manual release beside the leaf.

Sliding or swing?

Sliding where the wall beside the opening can carry a track and the floor must stay clear, swing where the leaf must open on its hinges.

What stops the leaf hurting someone?

Sensors proved to EN 12453: photocells watch the opening, safety edges stop the leaf on contact, and loops hold the leaf open while a vehicle waits.

Can an automatic door sit on an escape route?

Yes, where the leaf releases from its operator when the alarm sounds, so the leaf opens with one push and no power.

Who checks the doors?

The person who runs the building, on the round that walks every entrance. The record lives with the building file.

If this is one of several openings on the site, the enquiry checklist shows the rating, hardware and evidence to name for each.

Specifying automatic doors for an entrance?Send the entrance schedule and the traffic each opening must take for a tested door quotation.
Get a free quote

Related

More in guides for specifiers

10 mistakes when specifying certified security doors 10 steps to specify an LPS 1175 door Acceptance and Snagging of a Security Door or Barrier Job Access Control Doors Acoustic Doors: Ratings and Specification After a Forced Entry Attempt: Checking a Security Door Airport Security Doors Anti-Ligature Doors for Mental Health Wards Anti-Ram Bollards Anti-ram gates and barriers: protecting vehicle entrances Arcade Security Doors Explained Automatic Gates Cost Factors Automatic Vehicle Barriers Ballistic Panels Bank Security Doors Bingo Hall Security Doors Explained Blast doors: glazed vs solid and how they are rated Blast protection window film: what it does and what it cannot do Blast resistant windows: what drives the cost and how to specify them Bollard Cost Factors Explained Bollard regulations in the UK: spacing, height and depth Bookmaker Security Doors Explained Builders Merchant Security Doors Bullet Resistant Glass Cost Factors Bullet resistant glass ratings explained: BR1 to BR7 and SG classes Bullet resistant vs bulletproof glass: what the difference means Buying Security Doors and HVM Through Public Frameworks Car Park Security Doors Explained Car Showroom Security Doors Casino Security Doors Explained CDM 2015 Duties When Security Doors, Shutters or HVM Are Installed Cinema Security Doors Cleanroom Doors Cold Store Doors College Security Doors Commissioning, Handover and the O&M Manual for Security Doors and HVM Communal entrance doors for flats: Secured by Design and what to specify Community Centre Security Doors Control Room Doors Court Security Doors Crash Rated Fences and HVM Fencing Explained Data centre physical security: doors, glazing, HVM and shielding by zone Dental Practice Security Doors Depot Security Doors Explained Door Entry Systems Due Diligence When Selecting Vehicle Security Barriers Emergency Exit Doors EMP Shielding Cost Factors Explained Exhibition Centre Fire Door Rules Exhibition Centre Security Doors Factory Security Doors Faraday cage vs RF shielded room: what a business needs FB4 vs FB6 vs FB7: how to choose a ballistic rating Fire and security doors: how dual certification works Fire Compartmentation Fire Curtains Fire Door Certification Fire Door Closers Explained Fire Door Cost Factors Fire Door Duties of the Accountable Person Fire Door Gaps Fire Door Hardware Explained Fire door inspection checklist for steel and timber doors Fire Door Maintenance Fire Door Regulations Care Homes Fire Door Regulations for A and E Departments Fire Door Regulations for Airports Explained Fire Door Regulations for Bowls Clubs Fire door regulations for commercial buildings in the UK Fire Door Regulations for Dialysis Centres Fire Door Regulations for Hockey Clubs Fire Door Regulations for Hospitals Explained Fire Door Regulations for Offices Explained Fire Door Regulations for Operating Theatres Fire Door Regulations for Retail Explained Fire Door Regulations for Schools Explained Fire Door Regulations for Snooker Clubs Fire Door Regulations for Stadiums Fire Door Regulations for Student Accommodation Fire Door Regulations for Warehouses Fire Door Regulations Leisure Centres Fire Door Regulations Restaurants Fire Door Remediation Programme for Housing Providers Fire Door Rules for Badminton Clubs Fire Door Rules for Bingo Halls Fire Door Rules for Bookmakers Fire Door Rules for Bowling Alleys Fire Door Rules for Car Parks Fire Door Rules for Car Showrooms Fire Door Rules for Cinemas Fire Door Rules for Climbing Centres Fire Door Rules for Colleges Fire Door Rules for Community Centres Fire Door Rules for Cricket Clubs Fire Door Rules for Dental Practices Fire Door Rules for Depots Explained Fire Door Rules for Golf Clubs Fire Door Rules for GP Surgeries Fire Door Rules for Gyms Explained Fire Door Rules for Ice Rinks Fire Door Rules for Maternity Units Fire Door Rules for Mental Health Units Fire Door Rules for Museums Fire Door Rules for Oncology Units Fire Door Rules for Opticians Fire Door Rules for Pawnbrokers Fire Door Rules for Petrol Stations Fire Door Rules for Pharmacies Fire Door Rules for Ports Fire Door Rules for Post Offices Fire Door Rules for Prisons Fire Door Rules for Rehabilitation Centres Fire Door Rules for Self Storage Fire Door Rules for Shopping Centres Fire Door Rules for Squash Clubs Fire Door Rules for Supermarkets Fire Door Rules for Swimming Pools Fire Door Rules for Tennis Clubs Fire Door Rules for Theatres Fire Door Rules for UK Arcades Fire Door Rules for UK Casinos Fire Door Rules for UK Hospices Fire Door Rules for Walk-in Centres Fire Door Signage Fire Door Vision Panels Fire Doors and Gateway 2 in Higher-Risk Buildings Fire Rated Glass Cost Explained Fire Rated Sliding Doors Explained Fire Rated Windows Cost Factors Fire Rated Windows Explained Fire Safety Enforcement Notices and Fire Doors: What the Responsible Person Must Do Flat Entrance Doors: PAS 24 and Fire Rated Forced Entry vs Ballistic vs Blast: Which Rating a Site Needs Garage Security Doors Explained Gate Automation Explained Golden Thread Records for Fire Doors GP Surgery Security Doors Explained Gym Security Doors Explained High Speed Doors HMO Fire Doors Hospice Security Doors Explained Hospital Security Doors: Wards, A&E, Plant Hospital Security Gates Hotel Fire Doors Hotel Security Doors How to choose HVM bollards: fixed, shallow mount, removable and automatic How to keep an LPS 1175 door rating valid after installation How to Specify Fire Doors in a Housing Tender How to specify security doors: a checklist for architects How to Verify a Secured by Design Listing How to Verify an LPS 1175 Certificate on Red Book Live How to Write an Operational Requirement for Physical Security HVM planters and street furniture: protection that blends in In-Service Care of Vehicle Security Barriers Installation Handover: LPS 1175 Doors and PAS 68 Barriers Intumescent Seals ISO 16933 explained: EXV and SB classes and hazard ratings ISO 22343 vehicle security barriers explained Keeping a Dual-Certified Fire and Security Door Valid in Service Laboratory Security Doors Layered Security for a Site: Deter, Detect, Delay, Mitigate, Respond Lead Times and Programme Risks for LPS 1175 Doors Leisure Centre Security Doors Library Security Doors Listed Building Fire Doors Loading Bay Doors Explained Lockdown and Access Control Hardware on an LPS 1175 Door LPS 1175 Gates and Grilles Explained LPS 1175 Issue 8 explained: from SR1 to SR8 to A1 to H20 LPS 1175 Roller Shutters LPS 1175 vs ASTM F2781 and Other US Ratings Explained LPS 1175 vs EN 1627: how UK and European burglar resistance ratings compare LPS 1175 vs PAS 24: which security standard does your door need? LPS 1175 Windows and Walling Explained Martyn’s Law and Places of Worship: What a Buyer Checks for Doors and Entry Control Martyn’s Law Enhanced Tier: Physical Measures and the Specifier Brief Martyn’s Law Standard Tier: Procedures, Doors and Shutters Martyn’s Law Timeline and the SIA Regulator Martyn’s Law: what premises must do and which physical measures to consider Master Key Systems MRI and RF shielded rooms: how they work and what to specify Museum Security Doors NPSA Catalogue of Security Equipment (CSE) Explained NPSA Forced Entry and Blast Guidance for Government Sites NPSA Guidance on Lockdown and Marauding Attack: What It Asks of Doors and Entrances Office Security Doors Optician Security Doors Explained Panic Hardware PAS 24 requirements for doors and windows explained PAS 68 Bollard Foundations Explained PAS 68 bollards: ratings, spacing and cost factors PAS 68 vs IWA 14 vs ISO 22343: hostile vehicle mitigation standards explained Pawnbroker Security Doors Explained Pedestrian Gates Petrol Station Security Doors Pharmacy Security Doors Planning Permission for Security Shutters, Gates and Bollards on Commercial Premises Plant room doors: fire, security and ventilation requirements Plant Room Fire Doors Port Security Doors Post Office Security Doors Explained Powder coating vs galvanising vs paint for steel Preliminary Market Engagement for Security Doors and HVM Prison Security Doors Programming a Security Door and Barrier Package on a Live Site Public-Sector Tender Response Checklist for Security Door and HVM Supply Reading a PAS 24 and SBD Door Test Report Regulation 38 Fire Safety Information at Handover for Fire-Rated Security Doorsets Replacing Security Doors in an Occupied Building Restaurant Security Doors Retail Security Doors Revolving Doors RF shielding standards and how shielded rooms are tested Rising Bollard Cost Factors Road Blocker Cost Factors Explained Road Blockers Explained Roller Shutter Cost Factors: What Drives the Price Roller shutter regulations in the UK: safety and maintenance Safe room and panic room doors: specification basics Safety Duties for Powered Doors, Gates and Barriers on Commercial Sites School Security Doors Sectional Doors Secured by Design explained: is it mandatory for doors? Secured by Design vs NPSA vs LPCB: Which One You Need Security Door Locks Security Door Maintenance Checklist Security Doors and Access for Everyone: What Approved Document M Asks Security Doors for A and E Departments Security Doors for Badminton Clubs Security Doors for Bowling Alleys Security Doors for Bowls Clubs Security Doors for Climbing Centres Security Doors for Cricket Clubs Security Doors for Dialysis Centres Security Doors for Golf Clubs Security Doors for Hockey Clubs Security Doors for Ice Rinks Security Doors for Maternity Units Security Doors for Mental Health Units Security Doors for Oncology Units Security Doors for Operating Theatres Security Doors for Rehabilitation Centres Security Doors for Snooker Clubs Security Doors for Squash Clubs Security Doors for Swimming Pools Security Doors for Tennis Clubs Security Doors for Walk-in Centres Security Doors West Midlands Explained Security Fencing Security Gates Cost Factors Explained Security shutters vs high performance roller doors Security shutters vs retractable grilles: which suits retail and commercial openings? Security Turnstiles Explained Security Window Film Security Windows for Schools Explained Self Storage Security Doors Server Room Doors Explained Shopping Centre Security Doors Smoke Control Doors Explained Smoke Curtains Specification Mistakes When Mixing LPS 1175, PAS 24 and SBD in One Tender SR2 vs SR3 vs SR4 security doors: choosing the right LPS 1175 level Stadium Security Doors Steel Door Frames Steel vs aluminium security doors: strength, ratings and looks Steel vs timber fire doors: which suits your building? Student Accommodation Security Doors Substation doors: security, ventilation and specification Supermarket Security Doors Telescopic Bollards Tender Evaluation Criteria and Scoring for Security Doors and HVM The Scope of a Maintenance Contract for Security Doors and Barriers Theatre Security Doors Thermal and Weather Performance of External Security Doorsets Thermally broken steel security doors: U-values and certification Traffic Calming as Hostile Vehicle Mitigation Transport hub security requirements Turnstile Cost Factors Explained Turnstile vs speed gate vs security portal: choosing entrance control Types of security doors for commercial buildings University Security Doors Explained Vehicle Dynamics Assessment: What It Tells the Buyer Before a Barrier Is Specified Warehouse Security Doors Explained Warehouse Security Gates Warranty, Defects Liability and Guarantees for Security Doors and Barriers What affects the cost of a bullet resistant door What affects the cost of a high-security door in the UK Window Security Bars View all →

Products

One supplier for the whole building envelope

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.