A car showroom holds visitors, fuel and high-value stock behind its doors, so each fire door takes its period from the room behind it and the way out.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A car showroom is a public building where visitors walk among cars they have never sat in before, and the fire doors must hold the line and let people out. The leaf holds fire back for its period, and it opens for people who have never walked the route, so each door takes the period the room behind it demands.
The period on a showroom door follows the room behind the leaf, because the showroom floor, the workshop and the parts store ask different things of the doors that guard them. The order carries the period beside each opening, so the leaf that arrives is the leaf the room needs.
The rules for the shared parts of a public building are set out in the fire door regulations commercial buildings guide, and the rules for the shops beside the showroom are set out in the fire door regulations retail guide. The showroom order names every door in the building, with the period and the hardware beside each one.
- FD30 / FD60Fire periods to EN 1634-1
- E / EW / EI 30-120What the letters beside the period mean
- 4 mmThe gap round the leaf
- One listEvery showroom door named
Showroom floor, workshop and offices: one building, three parts
A car showroom is three buildings in one: the floor where the cars stand and the visitors walk, the workshop where the cars are serviced, and the offices and stores that serve them both. The rules follow those parts, because a door between one part and the next must hold the fire where it started while the visitors reach the way out.
The showroom floor takes the doors that let a visitor in and out, and each leaf must open for people who have never seen the building before. The workshop takes the doors that guard the service bays, and each leaf must hold fire back where the fuel and the paint sit. The route that joins them takes the doors the visitors pass through, and each leaf takes the period the escape needs.
The showroom writes its fire strategy first, naming every opening with the door beside it, and the order follows the strategy, so no leaf is ordered without the room it guards behind it.
FD30 and FD60 in a showroom: the periods each part takes
Each part of a showroom asks a different period of its doors, because the load behind each leaf is different. The floor holds the cars and the visitors, the workshop holds the fuel and the paint, and the parts store holds the stock in boxes and crates, so the period on each door follows the room, not the leaf.
EN 1634-1 is the test that proves a fire door, and the proof is written as minutes beside letters. Thirty minutes is the shortest period on the scale and 120 is the longest, and the letters say what stayed back: flames on their own, flames with some heat, or flames with the heat as well. Minutes and letters are ordered together, because the minutes alone say only half of what the door proved.
A door that must hold longer is a heavier door, with a deeper frame to carry it, and the figure on the quotation climbs with the weight. No opening that needs 60 minutes should take a leaf proved for 30, because the shorter leaf is the one that gives way first.
The showroom floor: glass, cars and the doors between them
The showroom floor is mostly glass, and the doors on it must hold their proof while letting the light through. A glazed leaf lets a visitor see the cars beyond it without opening the leaf, and the pane takes the same proof as the leaf, because the leaf and the glass are proved as one doorset. The bead and the fixings the test report names are written on the order beside the glass.
The cars on the floor carry fuel in their tanks, and the doors between the floor and the workshop must hold the fire where it starts. A leaf between the floor and the workshop takes the period the workshop demands, because the fire that starts among the cars must stay among the cars while the visitors move out.
Windows that share the same wall are covered in the fire rated windows guide, and the fire rated glass cost guide works through what the glass itself costs.
Workshops and paint shops: the doors behind the service bays
The workshop takes the heaviest fire load in the showroom, because the fuel, the oil and the paint sit behind its doors all day. A workshop leaf takes FD60 where the load is heaviest, and the period follows the fire load, not the size of the showroom.
The paint shop takes the same care, because the solvents behind its doors burn fast once the fire reaches them. A paint shop leaf takes the period the load behind it demands, and the seals round it must hold as long as the leaf, because a seal that has come away lets the smoke reach the corridor first. The gap round the leaf is kept to 4 mm, and the seal is checked with the leaf shut.
The service bays take doors that stand open through the day, so the cars can move in and out without stopping at every leaf. A leaf that must stand open takes a hold-open device proved to BS EN 1155, so the leaf shuts on its own the moment the alarm sounds. A leaf wedged open with a trolley holds nothing back when the fire comes, and the wedge belongs in the store, not under the leaf.
Parts stores and back offices: the doors that guard the stock
The parts store holds the stock the workshop runs on, and the leaf that guards it takes the period the load behind it demands. A store leaf takes FD60 where the stock is boxed and crated, because the boxes burn fast once the fire reaches them, and the leaf must shut after every load that passes.
The back offices take the doors that guard the staff and the records, and each leaf takes the period the office beside it takes.
A showroom leaf earns its forced entry category from what sits behind it. Issue 8.2, dated September 2024, sets B3 at three minutes, C5 at five and D10 at ten, so the category on the order follows the value of the stock in the room. The LPS 1175 vs PAS 24 guide puts the two ratings beside each other, and the keeping an LPS 1175 rating valid guide lists what can break a rating after a door is fitted.
Escape routes through a showroom: the way out for visitors
The visitors in a showroom follow the route the building gives them, and the way out must be clear when the alarm sounds. Each door on the route opens with one push from anyone who reaches it, because the leaf must open whether the power is there or not.
The seals on the route doors carry a smoke proof to BS EN 1634-3, Sa where the smoke is at room temperature and S200 where it is at 200 degrees. A seal only works when it meets the frame all the way round, and smoke gets to the route ahead of the flames. The smoke control doors guide covers how the doors hold smoke back while people move past them.
One route takes one period on every leaf, because the weakest door on the route sets how long the route holds. A leaf with a shorter proof than the leaves beside it is the leaf that fails first, so the route takes no leaf shorter than the period the route needs. The doors that guard a warehouse are covered in the warehouse security doors guide, and a showroom takes the same care with its stores as a warehouse takes with its own.
| Position | Door | Period | What to check |
|---|---|---|---|
| Showroom floor | Glazed leaf | FD30 | Leaf, glass, closer |
| Workshop | Steel leaf | FD60 | Leaf, lock, seals |
| Parts store | Steel leaf | FD60 | Leaf, lock, seals |
| Public route | Fire leaf | FD30 | Leaf, bar, closer |
| Plant room | Fire leaf | FD60 | Leaf, seals, gap |
What keeps the period: the closer, the seal and the gap
Every visitor who walks through a showroom door puts the closer to work, and the leaf must come home behind each one without a slam. BS EN 1154 sets EN 3 as the smallest power a fire door closer may take, and the test is simple: open the leaf and watch it shut on its own. A closer that has lost its pull leaves the leaf standing open after the visitor has passed.
The gap beside the leaf stays at 4 mm, so the leaf swings without catching and the seal can close the opening when the leaf shuts. Heat near 200 to 250 degrees makes the intumescent seal swell, and paint laid over the seal stops it swelling when the fire comes. A seal that has slipped out of its groove is written against its door on the day someone finds it.
Each hinge takes its share of the leaf through every opening of the day. A hinge that works loose lets the leaf sink a little month by month, until it drags and the gap at the top lets smoke through. The fire door hardware guide names what the lock the key turns must do, and the fire door closers guide works through sizes and fitting.
The showroom order: every door on one list
The showroom order is one list, with a line for every door in the building and the leaf, the period, the lock and the closer beside each one, so the door that arrives is the door that was ordered. Where the list names one leaf for the whole showroom, the fitter must guess which room takes which period, and a leaf fitted to the wrong room guards the wrong thing.
The quotation is checked against the list, figure by figure, with each one sitting beside the door it belongs to. A figure missed off the quotation still has to be paid, and a part added later costs more than the same part ordered with the building. The how to specify security doors guide sets out the columns the list needs, and the security door cost factors guide works through what each step up the scale adds to the price.
Once a month the showroom tries every leaf before the doors open, working from the floor through the workshop to the stores. A leaf that drags, a seal that has slipped from its groove, or a closer that has lost its pull is written against its door on the day it is found, and the repair is booked while the fault is still small. The record stays with the building file, and the fire door inspection checklist sets out what the visit should cover.
In a car showroom the period, the release and the closer decide together whether the way out works, so all three sit on the same list before the order goes out.
What period should a showroom door carry?
FD30 or FD60 to EN 1634-1, with letters beside the minutes that say what the doorset held back. Which period the door takes depends on the room behind the leaf.
Can one leaf hold fire and forced entry?
Yes, when the same leaf, frame and seals went through the fire test and the forced entry test together, so one doorset carries the proof for both jobs.
Do showroom doors need panic hardware?
Yes, the leaf on the way out takes a bar proved to BS EN 1125, running across at least 60 percent of the leaf, so one push opens it for the visitors behind it.
What grade should a parts store door carry?
The grade follows the room: B3, C5 or D10 to LPS 1175, with the parts store taking a higher category than the showroom floor.
Who checks the showroom doors?
The showroom manager walks the round that covers every door, and each visit is written into the record the building keeps.