Security Doors for Oncology Units

An oncology unit holds treatment rooms and a drug store beside wards where patients stay for long courses, so each leaf takes the LPS 1175 grade its room needs.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed across the UK
Prefer to talk?+44 7352 267239

Get a free project quote

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

An oncology unit holds treatment rooms and a drug store beside wards where patients stay for long courses, so the grade on each leaf follows the room behind it. The entrance, the reception, the waiting area, the treatment rooms and the ward entrance take B3, the staff office and the plant room take C5, and the drug store takes D10, because the medicines behind that leaf hold the most portable value in the unit.

LPS 1175 Issue 8.2, dated September 2024, gives each grade by the minutes the leaf stood against the tools named in the test. A B3 leaf stood for three minutes, a C5 leaf for five minutes and a D10 leaf for ten minutes, and the test took the leaf, the frame, the fixings and the lock as one doorset. Older drawings may still call the same three leaves SR2, SR3 and SR4, so the order carries the old name beside the new grade.

An oncology unit is not a hospice, because the unit holds treatment rooms and a drug store beside wards where patients return for course after course, while a hospice holds bedrooms for people near the end of life. It is not a hospital in general either, because the rooms named here belong to cancer care alone, and the hospital security doors guide grades the doors of the wider hospital round it, while the security doors for hospices guide grades the doors of a building where bedrooms stand beside a drug store. Rooms that need shielding from radio waves sit outside this page, and the RF shielding page holds that detail.

  • B3 / C5 / D10Grades to LPS 1175 Issue 8.2
  • Drug storeWhere D10 sits in the unit
  • Slow patientsSome move slowly and feel unwell
  • One listEvery unit leaf named

Eight rooms in an oncology unit: the grade each leaf takes

Eight rooms make up an oncology unit, and the grade follows what each room holds. The eight rooms are the entrance, the reception, the waiting area, the treatment rooms, the ward entrance, the drug store, the staff office and the plant room.

B3 sits on the entrance, the reception, the waiting area, the treatment rooms and the ward entrance, because all five stand where patients and staff can see them through the day. C5 goes on the staff office and the plant room, because the records and the services behind those leaves ask for a longer hold. The drug store takes D10, because the medicines behind it hold the most portable value in the unit.

Every opening carries its own line on the order, naming the leaf, the grade and the minutes, so the fitter checks each leaf against its line before the leaf is hung.

Room Grade Minutes What to check
Entrance B3 3 Leaf, lock, closer
Reception B3 3 Leaf, lock, reader
Waiting area B3 3 Leaf, lock, closer
Treatment rooms B3 3 Leaf, lock, panel
Ward entrance B3 3 Leaf, lock, closer
Drug store D10 10 Leaf, lock, no glass
Staff office C5 5 Leaf, lock, reader
Plant room C5 5 Leaf, lock, seals

A single leaf can hold the fire proof and the forced entry proof at once, so one report carries the period and the grade together. The fire minutes run from 30 to 120 under EN 1634-1, and the letter beside the number says what the leaf held back, E for flame alone, EW for flame with part of the heat and EI for flame with the heat too. The fire and security doors dual certification guide shows the pair proved on the same leaf, and the SR2 vs SR3 vs SR4 guide sets the old names beside the new grades.

The entrance, reception and waiting area: B3 where patients arrive

Patients arrive at the entrance through the day, some on foot and some in wheelchairs, and some feel very unwell by the time they reach the reception desk.

A patient pushing the entrance leaf meets a limit set by BS 8300 and Approved Document M, under 30 N across the first 30 degrees of swing and under 22.5 N after that, so the leaf opens for a person who moves slowly and leans on a frame for support. The closer that pulls the leaf shut holds a proof to BS EN 1154, and the standard names EN 1 as its smallest power size.

Martyn’s Law gained Royal Assent in April 2025, with the start expected in spring 2027, its lower tier taking in premises that may hold 200 to 799 people and its higher tier taking in 800 or more. The Martyns Law guide for premises names what each tier asks. Bollards keep a vehicle off the frontage, with the clear gap between them no more than 1,200 mm and each bollard at least 500 mm high under ProtectUK, and the choosing HVM bollards guide covers the layout.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Treatment rooms: B3 beside the chair and the line

Treatment rooms hold chairs, lines and pumps, and a patient may sit in the chair for hours while the treatment runs. The leaf takes B3 and stays shut while the room is in use, because the lines and pumps behind it stay out of reach.

Staff see into the room through a panel set high in the leaf, so the room can be watched without the leaf being opened. The panel goes through the test with the leaf round it, so the report names the glass and its fixings beside the leaf.

The lock on the room side lets staff open the leaf at once when the treatment ends or the patient needs help. The access control doors guide covers the readers and locks on a leaf that opens to staff alone.

The treatment room door shuts behind each patient, so the course stays private

A treatment room door in an oncology unit shuts while the line runs and opens between patients, so the course stays private from the corridor. The chair, the line and the nurse stay behind a shut door for the whole session, and the door opens only when the session ends.

The latch and the closer carry that rhythm. The latch must catch each time the door is pulled to, and the closer must draw the door home after every pass, because a door that stands ajar between patients gives the corridor a view of the chair and the line. Staff listen for the click as the latch catches, and a latch that misses its keep is written down the same day.

The panel beside the treatment room door answers a staff card and holds the door shut against every other card, and the door entry systems guide names the panels a unit fits at its front rooms. Staff pass through with a card in hand while the waiting area fills, and the door shuts behind each one.

Point in the course Door state Who moves it
Line running Shut, latch caught Nurse in the room
Between patients Opened, then drawn shut Nurse clearing the room
End of the day Shut and tried Nurse closing the unit

The treatment room door is graded B3 under LPS 1175 Issue 8, holding for three minutes against the tools the test names, and the same door can carry FD60 beside it, with the fire minutes proved to EN 1634-1 and the forced entry minutes proved to LPS 1175 Issue 8 in one report. The dual certification guide shows the two proofs standing side by side in one report for a single door.

Between patients: latch, closer and gap

Between patients the nurse works the door three ways at once. The latch is tried with a pull, the closer is watched as it draws the door home, and the gap beside the door is looked at for an even line. A closer that lets the door swing free or a gap grown wide at one side tells the nurse the door will not hold as it should.

The lock on the drug store door answers a key held by the nurse in charge, and no other key in the unit opens it. The locks guide names the lock a store door must carry and the key that opens it.

A door opened a hundred times a day through months of courses must still meet its frame at the end of the year, so the hinges are proved to BS EN 1935, with grade 13 tested to 200,000 cycles at 120 kg and grade 14 tested to the same cycles at 160 kg. The keeping an LPS 1175 rating valid guide lists the changes that strip a door of its grade after it is hung.

Where more than 60 people use the way out, the doors carry a push bar proved to BS EN 1125, and the bar covers no less than three fifths of the door width. The panic hardware guide covers the bar that must free the door when a crowd leans on it.

An oncology unit is ordered room by room, and the healthcare quote page takes the treatment rooms one by one.

The ward entrance: B3 where patients stay for long courses

The ward holds patients through long courses, and they come back to the same beds week after week. The ward entrance takes B3, and the leaf stays shut through the night, because the people behind it sleep there and cannot move fast.

Where the route serves more than 60 people, a push bar proved to BS EN 1125 runs across the leaves on the way out and covers no less than 60 percent of the leaf width, so one push from a person in a crowd throws the leaf open. What the bar must do when a crowd pushes against the leaf is named in the panic hardware guide.

Patients on the ward move slowly, some with lines still in place, so the route out matters as much as the grade on the leaf. The emergency exit doors guide covers the leaves on the way out.

The drug store: D10 behind the medicines

The drug store holds the medicines for the whole unit, so its leaf takes D10, the longest hold LPS 1175 Issue 8.2 names. The test took the leaf, frame, fixings and lock as one doorset, and the report gives ten minutes against the tools the test names, because the medicines inside are the easiest value in the unit to carry out. No published table sets LPS 1175 grades beside ASTM ratings, so the order carries the LPS grade alone.

The drug store leaf carries no glass, because a pane would let the corridor see the shelves. Under TS 007, a 1 star cylinder beside a 2 star handle counts as a 3 star set, so the two are ordered as one set and never apart. The security door locks guide names what the lock on the drug store must do, and the keys to the room are held by named staff only. The security doors for pharmacies guide grades the doors of a building that holds medicines behind a counter.

The drug store leaf stays shut and locked whenever no one works inside, and the leaf is tried each morning before the first treatment starts. A leaf that will not shut holds no grade at all.

Staff office and plant room: C5 behind the back rooms

The staff office holds the patient records and the papers that run the unit, so C5 sits on its leaf and the leaf stays locked when the room is empty, because an open office would hand a passer by the records and the keys behind it.

The plant room holds the boards and the equipment that keep the air moving and the water hot, so its leaf takes C5 as well. The plant room door requirements guide names in full what a leaf on that room must do.

Hinges proved to BS EN 1935 carry the leaf, grade 13 through 200,000 cycles with a leaf of 120 kg and grade 14 through the same cycles with a leaf of 160 kg, so the bolt keeps meeting its keep. The leaf between the office and the reception must shut by itself after every pass, and its closer holds a proof to BS EN 1154, with no fire leaf taking a power size below EN 3.

Keys, cards and readers: who opens which oncology leaf

Each leaf behind the reception opens to the cards and keys of the staff who work there, and a public card opens none of them. The master key systems guide sets out a key plan that gives each holder the rooms their work needs and no room beyond those.

The ward manager holds a key that opens every leaf behind the reception, and nurses hold keys for the rooms their shifts take them to. The 10 steps to specify an LPS 1175 door guide sets out how the order runs, and the door entry systems guide covers the panel that lets staff through from the street. A lost card is taken off the reader list the day it is reported, so a card found on the waiting area floor opens nothing.

The entrance leaf opens to a familiar card before the waiting room fills

Patients who return week after week learn the way in, and the entrance leaf opens to the card they carry before the waiting room fills for the morning. The same faces come back for course after course, so the leaf that greets them must know their card and still hold against a card it has never seen. A leaf that opens to every card guards nothing, and a leaf that opens to none keeps the patients it was built for outside.

The panel beside the entrance leaf answers a staff card and holds the leaf shut against every other card, and the guide to door entry systems names the panels a unit fits at its front. Staff pass through with a card in hand while the waiting room fills, and the leaf shuts behind each one, so the corridor behind the reception stays shut to the public side.

Leaf Who opens it How often
Entrance Staff card and patient card Through the day
Ward entrance Staff card only At each round
Drug store Nurse in charge only To fetch medicines

The drug store leaf holds D10 to LPS 1175 Issue 8, ten minutes of hold against the tools the test names, and the same leaf can carry FD60 beside it, with the fire minutes proved to EN 1634-1 and the forced entry minutes proved to LPS 1175 Issue 8 in one report. The dual certification guide shows the two proofs standing side by side in one report for a single leaf.

A leaf opened a hundred times a day through months of courses must still meet its frame at the end of the year, so the hinges are proved to BS EN 1935, grade 13 proved through 200,000 cycles while carrying a leaf of 120 kg, and grade 14 proved through the same cycles while carrying a leaf of 160 kg. The leaf that hangs true keeps its bolt in line with its keep, and a leaf that drops on its hinges leaves a gap the grade cannot cover.

The lock on the drug store leaf answers a key held by the nurse in charge, and no other key in the unit opens it, so the medicines are fetched by one named hand and the leaf is shut behind them. The locks guide names the lock a drug store leaf must carry and the key that opens it.

Between courses, the ward entrance leaf stays shut through the night

Where more than 60 people use the way out, the leaves carry a push bar proved to BS EN 1125, and the bar covers no less than three fifths of the leaf width, so the waiting room empties through the leaves in one movement. The panic hardware guide covers the bar that must free the leaf when a crowd leans on it.

The grade holds only while the leaf, the frame and the hardware stay as they were tested, and a closer swapped after handover or a reader cut into the leaf can take the rating off it. The guide to keeping an LPS 1175 rating valid lists the changes that strip a leaf of its grade after it is hung.

Every leaf on the order carries its grade and its key, and the healthcare doors quote page takes the unit leaf by leaf, so the long course and the leaves that guard it stand on one order together.

The oncology unit order: every leaf, its grade and its lock

One list holds the whole order, with a line for every opening naming the leaf, the grade, the lock and the closer. A leaf with no line of its own may end up hung where it does not belong, and a C5 leaf on the drug store would hold for five minutes where the medicines ask for ten.

The ward manager takes the door list round the unit each month and tries each leaf in turn. A leaf that drags, a bolt that misses its keep or a reader that stays silent goes beside its own door on the list the day it is found, and what the walk should cover is named in the security door maintenance checklist.

Each leaf on the order is read before the order is signed. What the order must hold for every door is set out in the how to specify security doors guide, and how the frame holds the leaf and the lock together is named in the steel door frames guide.

The grade on an oncology unit leaf follows the room behind it, so the leaf, the lock and the reader are ordered together and checked together against the medicines behind the leaf.

What grade does an oncology unit entrance take?

B3 to LPS 1175 Issue 8.2, which holds for three minutes, because the entrance stands in view of the reception staff through the day.

What grade does a drug store take?

D10 to LPS 1175 Issue 8.2, which holds for ten minutes, because the medicines sit behind a leaf shut and locked when no one works inside.

What grade does a treatment room leaf take?

B3 to LPS 1175 Issue 8.2, which holds for three minutes, because the room holds lines and pumps behind a shut leaf while the treatment runs.

Can one leaf hold fire and forced entry?

Yes, where the same leaf was put through the fire test and the forced entry test, so a single report carries the period and the grade together.

Who checks the oncology unit doors?

The ward manager walks the unit with the door list each month and tries the leaves in turn, so a fault is found and put right.

Specifying security doors for an oncology unit?Send the door list with the grade and the lock each room must hold for a tested door quotation.
Get a free quote

Related

More in guides for specifiers

10 mistakes when specifying certified security doors 10 steps to specify an LPS 1175 door Acceptance and Snagging of a Security Door or Barrier Job Access Control Doors Acoustic Doors: Ratings and Specification After a Forced Entry Attempt: Checking a Security Door Airport Security Doors Anti-Ligature Doors for Mental Health Wards Anti-Ram Bollards Anti-ram gates and barriers: protecting vehicle entrances Arcade Security Doors Explained Automatic Doors Automatic Gates Cost Factors Automatic Vehicle Barriers Ballistic Panels Bank Security Doors Bingo Hall Security Doors Explained Blast doors: glazed vs solid and how they are rated Blast protection window film: what it does and what it cannot do Blast resistant windows: what drives the cost and how to specify them Bollard Cost Factors Explained Bollard regulations in the UK: spacing, height and depth Bookmaker Security Doors Explained Builders Merchant Security Doors Bullet Resistant Glass Cost Factors Bullet resistant glass ratings explained: BR1 to BR7 and SG classes Bullet resistant vs bulletproof glass: what the difference means Buying Security Doors and HVM Through Public Frameworks Car Park Security Doors Explained Car Showroom Security Doors Casino Security Doors Explained CDM 2015 Duties When Security Doors, Shutters or HVM Are Installed Cinema Security Doors Cleanroom Doors Cold Store Doors College Security Doors Commissioning, Handover and the O&M Manual for Security Doors and HVM Communal entrance doors for flats: Secured by Design and what to specify Community Centre Security Doors Control Room Doors Court Security Doors Crash Rated Fences and HVM Fencing Explained Data centre physical security: doors, glazing, HVM and shielding by zone Dental Practice Security Doors Depot Security Doors Explained Door Entry Systems Due Diligence When Selecting Vehicle Security Barriers Emergency Exit Doors EMP Shielding Cost Factors Explained Exhibition Centre Fire Door Rules Exhibition Centre Security Doors Factory Security Doors Faraday cage vs RF shielded room: what a business needs FB4 vs FB6 vs FB7: how to choose a ballistic rating Fire and security doors: how dual certification works Fire Compartmentation Fire Curtains Fire Door Certification Fire Door Closers Explained Fire Door Cost Factors Fire Door Duties of the Accountable Person Fire Door Gaps Fire Door Hardware Explained Fire door inspection checklist for steel and timber doors Fire Door Maintenance Fire Door Regulations Care Homes Fire Door Regulations for A and E Departments Fire Door Regulations for Airports Explained Fire Door Regulations for Bowls Clubs Fire door regulations for commercial buildings in the UK Fire Door Regulations for Dialysis Centres Fire Door Regulations for Hockey Clubs Fire Door Regulations for Hospitals Explained Fire Door Regulations for Offices Explained Fire Door Regulations for Operating Theatres Fire Door Regulations for Retail Explained Fire Door Regulations for Schools Explained Fire Door Regulations for Snooker Clubs Fire Door Regulations for Stadiums Fire Door Regulations for Student Accommodation Fire Door Regulations for Warehouses Fire Door Regulations Leisure Centres Fire Door Regulations Restaurants Fire Door Remediation Programme for Housing Providers Fire Door Rules for Badminton Clubs Fire Door Rules for Bingo Halls Fire Door Rules for Bookmakers Fire Door Rules for Bowling Alleys Fire Door Rules for Car Parks Fire Door Rules for Car Showrooms Fire Door Rules for Cinemas Fire Door Rules for Climbing Centres Fire Door Rules for Colleges Fire Door Rules for Community Centres Fire Door Rules for Cricket Clubs Fire Door Rules for Dental Practices Fire Door Rules for Depots Explained Fire Door Rules for Golf Clubs Fire Door Rules for GP Surgeries Fire Door Rules for Gyms Explained Fire Door Rules for Ice Rinks Fire Door Rules for Maternity Units Fire Door Rules for Mental Health Units Fire Door Rules for Museums Fire Door Rules for Oncology Units Fire Door Rules for Opticians Fire Door Rules for Pawnbrokers Fire Door Rules for Petrol Stations Fire Door Rules for Pharmacies Fire Door Rules for Ports Fire Door Rules for Post Offices Fire Door Rules for Prisons Fire Door Rules for Rehabilitation Centres Fire Door Rules for Self Storage Fire Door Rules for Shopping Centres Fire Door Rules for Squash Clubs Fire Door Rules for Supermarkets Fire Door Rules for Swimming Pools Fire Door Rules for Tennis Clubs Fire Door Rules for Theatres Fire Door Rules for UK Arcades Fire Door Rules for UK Casinos Fire Door Rules for UK Hospices Fire Door Rules for Walk-in Centres Fire Door Signage Fire Door Vision Panels Fire Doors and Gateway 2 in Higher-Risk Buildings Fire Rated Glass Cost Explained Fire Rated Sliding Doors Explained Fire Rated Windows Cost Factors Fire Rated Windows Explained Fire Safety Enforcement Notices and Fire Doors: What the Responsible Person Must Do Flat Entrance Doors: PAS 24 and Fire Rated Forced Entry vs Ballistic vs Blast: Which Rating a Site Needs Garage Security Doors Explained Gate Automation Explained Golden Thread Records for Fire Doors GP Surgery Security Doors Explained Gym Security Doors Explained High Speed Doors HMO Fire Doors Hospice Security Doors Explained Hospital Security Doors: Wards, A&E, Plant Hospital Security Gates Hotel Fire Doors Hotel Security Doors How to choose HVM bollards: fixed, shallow mount, removable and automatic How to keep an LPS 1175 door rating valid after installation How to Specify Fire Doors in a Housing Tender How to specify security doors: a checklist for architects How to Verify a Secured by Design Listing How to Verify an LPS 1175 Certificate on Red Book Live How to Write an Operational Requirement for Physical Security HVM planters and street furniture: protection that blends in In-Service Care of Vehicle Security Barriers Installation Handover: LPS 1175 Doors and PAS 68 Barriers Intumescent Seals ISO 16933 explained: EXV and SB classes and hazard ratings ISO 22343 vehicle security barriers explained Keeping a Dual-Certified Fire and Security Door Valid in Service Laboratory Security Doors Layered Security for a Site: Deter, Detect, Delay, Mitigate, Respond Lead Times and Programme Risks for LPS 1175 Doors Leisure Centre Security Doors Library Security Doors Listed Building Fire Doors Loading Bay Doors Explained Lockdown and Access Control Hardware on an LPS 1175 Door LPS 1175 Gates and Grilles Explained LPS 1175 Issue 8 explained: from SR1 to SR8 to A1 to H20 LPS 1175 Roller Shutters LPS 1175 vs ASTM F2781 and Other US Ratings Explained LPS 1175 vs EN 1627: how UK and European burglar resistance ratings compare LPS 1175 vs PAS 24: which security standard does your door need? LPS 1175 Windows and Walling Explained Martyn’s Law and Places of Worship: What a Buyer Checks for Doors and Entry Control Martyn’s Law Enhanced Tier: Physical Measures and the Specifier Brief Martyn’s Law Standard Tier: Procedures, Doors and Shutters Martyn’s Law Timeline and the SIA Regulator Martyn’s Law: what premises must do and which physical measures to consider Master Key Systems MRI and RF shielded rooms: how they work and what to specify Museum Security Doors NPSA Catalogue of Security Equipment (CSE) Explained NPSA Forced Entry and Blast Guidance for Government Sites NPSA Guidance on Lockdown and Marauding Attack: What It Asks of Doors and Entrances Office Security Doors Optician Security Doors Explained Panic Hardware PAS 24 requirements for doors and windows explained PAS 68 Bollard Foundations Explained PAS 68 bollards: ratings, spacing and cost factors PAS 68 vs IWA 14 vs ISO 22343: hostile vehicle mitigation standards explained Pawnbroker Security Doors Explained Pedestrian Gates Petrol Station Security Doors Pharmacy Security Doors Planning Permission for Security Shutters, Gates and Bollards on Commercial Premises Plant room doors: fire, security and ventilation requirements Plant Room Fire Doors Port Security Doors Post Office Security Doors Explained Powder coating vs galvanising vs paint for steel Preliminary Market Engagement for Security Doors and HVM Prison Security Doors Programming a Security Door and Barrier Package on a Live Site Public-Sector Tender Response Checklist for Security Door and HVM Supply Reading a PAS 24 and SBD Door Test Report Regulation 38 Fire Safety Information at Handover for Fire-Rated Security Doorsets Replacing Security Doors in an Occupied Building Restaurant Security Doors Retail Security Doors Revolving Doors RF shielding standards and how shielded rooms are tested Rising Bollard Cost Factors Road Blocker Cost Factors Explained Road Blockers Explained Roller Shutter Cost Factors: What Drives the Price Roller shutter regulations in the UK: safety and maintenance Safe room and panic room doors: specification basics Safety Duties for Powered Doors, Gates and Barriers on Commercial Sites School Security Doors Sectional Doors Secured by Design explained: is it mandatory for doors? Secured by Design vs NPSA vs LPCB: Which One You Need Security Door Locks Security Door Maintenance Checklist Security Doors and Access for Everyone: What Approved Document M Asks Security Doors for A and E Departments Security Doors for Badminton Clubs Security Doors for Bowling Alleys Security Doors for Bowls Clubs Security Doors for Climbing Centres Security Doors for Cricket Clubs Security Doors for Dialysis Centres Security Doors for Golf Clubs Security Doors for Hockey Clubs Security Doors for Ice Rinks Security Doors for Maternity Units Security Doors for Mental Health Units Security Doors for Operating Theatres Security Doors for Rehabilitation Centres Security Doors for Snooker Clubs Security Doors for Squash Clubs Security Doors for Swimming Pools Security Doors for Tennis Clubs Security Doors for Walk-in Centres Security Doors West Midlands Explained Security Fencing Security Gates Cost Factors Explained Security shutters vs high performance roller doors Security shutters vs retractable grilles: which suits retail and commercial openings? Security Turnstiles Explained Security Window Film Security Windows for Schools Explained Self Storage Security Doors Server Room Doors Explained Shopping Centre Security Doors Smoke Control Doors Explained Smoke Curtains Specification Mistakes When Mixing LPS 1175, PAS 24 and SBD in One Tender SR2 vs SR3 vs SR4 security doors: choosing the right LPS 1175 level Stadium Security Doors Steel Door Frames Steel vs aluminium security doors: strength, ratings and looks Steel vs timber fire doors: which suits your building? Student Accommodation Security Doors Substation doors: security, ventilation and specification Supermarket Security Doors Telescopic Bollards Tender Evaluation Criteria and Scoring for Security Doors and HVM The Scope of a Maintenance Contract for Security Doors and Barriers Theatre Security Doors Thermal and Weather Performance of External Security Doorsets Thermally broken steel security doors: U-values and certification Traffic Calming as Hostile Vehicle Mitigation Transport hub security requirements Turnstile Cost Factors Explained Turnstile vs speed gate vs security portal: choosing entrance control Types of security doors for commercial buildings University Security Doors Explained Vehicle Dynamics Assessment: What It Tells the Buyer Before a Barrier Is Specified Warehouse Security Doors Explained Warehouse Security Gates Warranty, Defects Liability and Guarantees for Security Doors and Barriers What affects the cost of a bullet resistant door What affects the cost of a high-security door in the UK Window Security Bars View all →