ArxBridge
Car Park Security Doors Explained
A car park guards stair cores, plant rooms, cash offices and stores, so each leaf takes the grade the room behind it demands, on every deck.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A car park is a stack of decks joined by stair cores and lift lobbies, and the doors between those parts decide what stays where it belongs. The decks hold the drivers, the cores hold the way up and down, and the rooms behind them hold the takings, the systems and the plant, so each door takes its proof from the room behind it.
LPS 1175 sets the grade on a car park door, and the category follows what sits behind the leaf. Issue 8.2 of September 2024 names the three categories B3, C5 and D10, at three, five and ten minutes. The entrance takes the lowest of the three, the stair cores take the middle one, and the cash office takes the highest.
A car park follows the same rules as any other commercial building, and the fire door regulations commercial buildings guide covers the shared parts, while the warehouse security doors guide covers the stores beside the decks. The car park order names every door, with the grade and the lock beside each one, so the door that arrives is the door its room asked for.
- LPS 1175 B3 / C5 / D10Forced entry grades to Issue 8.2
- Stair coresWhere the grade rises
- FD30 / FD60Fire periods to EN 1634-1
- One listEvery car park door named
Stair cores, cash offices and stores: one car park, three grades
Three parts make up a car park, and the grade follows what each part holds. The decks hold the drivers, the stair cores hold the way between the decks, and the cash office holds the money the day has taken.
The entrance leaf opens for every driver who arrives and shuts behind them on its own, because a leaf left standing open guards nothing. The stair core leaf is never seen by the public, and it must hold against the attack the rooms behind it invite.
The order is written from a list that names every opening, the leaf it takes and the grade beside it, because a leaf with no line on the list may turn up on the wrong deck.
The entrance and the ticket hall: the leaves drivers meet first
An entrance leaf has two jobs: to open for every driver who arrives, and to hold an intruder out once the car park shuts. The leaf, the frame and the lock are proved as one doorset, and the test report names all three.
A closer pulls the entrance leaf shut after every driver who passes, because a leaf left standing open guards nothing. The closer is set so the leaf comes home without a slam, and the pull is checked by opening the leaf and watching it shut.
A glazed entrance leaf lets the staff see the driver outside before the leaf opens, and the pane carries the same proof as the leaf beside it. The bead and the fixings that hold the pane are named in the test report, and what the glass itself adds to the order is worked through in the fire rated glass cost guide.
Stair cores and lift lobbies: the doors between the decks
Behind every deck stands a stair core, and the leaf that guards it takes the grade the value behind it demands. C5 suits the stair core, because the rooms behind it justify the minutes it takes to break through, and the leaf must hold until the alarm is answered.
Only the car park team holds the key to the stair core, because drivers must never pass it alone. The core leaf takes C5, the cash office beside it takes D10, and the entrance takes B3.
A leaf on the stair core can carry both proofs at once, because the core needs fire held back and an intruder held out. The fire proof comes from EN 1634-1 in minutes and letters, E, EW and EI from 30 to 120, and the forced entry proof comes from LPS 1175 in B3, C5 and D10. The two tests run on the same leaf, frame and seals, so a single report holds both proofs, and the fire and security doors dual certification guide shows how one doorset carries the pair.
The core leaf shuts out the sound of the decks, so the lobbies stay quiet while cars move through. Seals round its edges and a closer that brings it home after every member of staff who passes do that work.
The cash office and the control room: where the takings and the systems sit
The cash office takes the highest grade in the car park, because the takings sit behind its leaf. Leaf, frame, fixings and lock are proved as one doorset, and the test report names each part, so the door that arrives is the door that was proved.
D10 suits the cash office, because it must hold longest, while the stair core beside it takes C5 and the entrance takes B3. Drawings drawn before Issue 8 call the same three categories SR2, SR3 and SR4, so the order carries the new name beside the old one.
The control room beside the cash office needs the same care, because the systems that run the barriers and the cameras sit behind its doors. Its leaf takes C5, and its lock takes the same key as the cash office, so the staff who work there can open both doors with one key. The keeping an LPS 1175 rating valid guide names what breaks a rating once a door is fitted.
Plant rooms and stores: the doors that keep the decks running
The plant room holds the services that keep the car park running, and its leaf takes the grade the value behind it demands. C5 suits the plant room, because the boards and the plant behind it justify the minutes it takes to break through.
Goods reach the car park through the stores and the loading bay, so the leaf there must be wide enough for pallets. C5 suits the stores leaf, because the stock passing through it is worth the minutes it takes to break through. Leaf, frame, fixings and lock are proved as one doorset, and the test report names the grade it holds. The loading bay doors guide covers the doors that take the deliveries in, and what the plant room leaf must do is set out in the plant room door requirements guide.
A stores leaf that stands open through the day takes a hold-open device proved to BS EN 1155, which releases the leaf the moment the alarm sounds.
A 4 mm gap is kept round the leaf, so it swings clear and the seal closes the opening once the leaf shuts. Once the heat passes 200 degrees the intumescent seal swells and closes that gap, unless a coat of paint over the seal stops it swelling.
The way out of a full car park: escape routes drivers can follow
In a car park the alarm sends drivers down the stair core the signs point to, and the way must be free of anything parked or stored against it. Each leaf on that way gives under one push from whoever reaches it first, with the power on or off.
Beside the fire period, each route door carries a smoke proof to BS EN 1634-3. The mark reads Sa for smoke at room temperature and S200 for smoke at 200 degrees. Smoke travels faster than flame, so it finds the drivers on the route before the fire does, and a seal holds only where it touches the frame all the way round. How the doors keep smoke back while people move past them is worked through in the smoke control doors guide.
No leaf on the route takes a shorter proof than the route needs, because the route lasts only as long as its weakest leaf. A leaf that gives way before its neighbours takes the route with it. The signs that lead drivers along the route are named in the fire door signage guide, and the bars that open the way out are named in the panic hardware guide.
| Position | Door | Grade | What to check |
|---|---|---|---|
| Entrance | Glazed leaf | LPS 1175 B3 | Leaf, glass, closer |
| Stair core | Steel leaf | LPS 1175 C5 | Leaf, lock, seals |
| Office | Steel leaf | LPS 1175 C5 | Leaf, lock, reader |
| Cash office | Steel leaf | LPS 1175 D10 | Leaf, lock, reader |
| Plant room | Steel leaf | LPS 1175 C5 | Leaf, lock, seals |
| Stores | Steel leaf | LPS 1175 C5 | Leaf, closer, lock |
Locks, cards and the car park team: who opens which door
Staff move from the entrance through the cores to the plant room and back, and each leaf on that route opens for staff and stays shut for the public. A reader sits beside every leaf on the route, and it opens for the cards the list names. The fire door hardware guide sets out what the lock the key turns must do, and the security door locks guide names what the lock on a car park leaf must hold.
The readers, the releases and the wiring beside a leaf are set out in the door entry systems guide.
The order names, beside each door, what its leaf does when the power fails, so no leaf is left without an answer on the night the supply goes. A leaf with no answer written beside it leaves the staff guessing when the answer matters most.
The car park order: every leaf on one list
The whole car park order sits on one list, a line for every door with the leaf, the grade, the lock and the closer beside it, so the door that arrives is the door its room asked for. A list that names a single leaf for the whole car park leaves the fitter to guess which room takes which grade, and a leaf on the wrong deck guards the wrong thing.
Each door carries its own figure on the schedule, and the schedule is laid beside the quotation and checked door by door before the order is sent, because a figure that never made it onto the quotation still turns up on the invoice, and a part ordered on its own after the doorset costs more than the same part ordered with the doorset. What the schedule must carry is set out in the how to specify security doors guide, and how the figure moves as the grade rises is shown in the security door cost factors guide.
Doors in the car park are tried through the week, a few leaves each day, so none goes untried for long: the entrance at opening, the core before the first driver arrives, and the cash office door at closing. Each fault goes down against its own door on the day it is found, with the leaf, the part and the date beside it, and the repair is booked before the next day starts. The fire door inspection checklist sets out what a visit should look for, and the security door maintenance checklist covers the doors that must hold both fire and forced entry.
A car park door holds only as long as the decks behind it and the cores beside it, so the grade, the period and the lock must all sit on the same list.
What grade should a car park door carry?
B3, C5 or D10 to LPS 1175. The cash office takes the highest category on the site, the stair cores take the middle one, and the entrance takes the lowest, so the grade follows the room behind the leaf.
Can one leaf hold fire and forced entry?
Yes, one leaf can do both jobs where the same doorset passed the fire test and the forced entry test together, so one report holds the two proofs.
Do car park doors need access control?
The doors behind the entrance take a reader beside the leaf, so the leaf opens for staff and stays shut for the public.
What period should a car park door carry?
A car park door takes FD30 or FD60, proved to EN 1634-1, and the letters beside the minutes name what the leaf held back. The period follows the room the leaf guards.
Who checks the car park doors?
The car park team walks the round that covers every door, and each visit stays in the car park file.
Get a free quote
Related
More in guides for specifiers
Products
One supplier for the whole building envelope
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.