An entry system decides who gets through the door and who stays outside, and the door behind it is only as useful as the system that opens it. A leaf proved to LPS 1175 can still stand open all day if the reader beside it lets everyone through, because the entry system is the part that asks the question before the leaf moves.
The system is not an extra on the order; it is part of how the door works. The panel by the door, the reader that takes the fob, the intercom that carries a voice to the flat above and the release that lets the leaf open all belong on the same line as the leaf, the frame and the lock.
The doors the system guards are set out in the communal entrance doors Secured by Design guide, and the turnstiles that guard a lobby line are covered in the security turnstiles guide. A system ordered without the doors it must open may fit the wrong leaf, so the panel, the reader and the release are named beside the door they serve.
- Audio and videoIntercom at the door
- Fail safeThe door when the power goes
- BS EN 1125Panic release beside the reader
- One scheduleEvery reader on one line
The panel by the door: what an entry system must do
An entry system has one job above all others: to open the door for the right person and keep it shut for everyone else. The panel by the door takes the call, the reader takes the fob, and the release throws the latch, so the leaf opens for a resident, a member of staff or a visitor who has been let in, and stays shut for the rest.
The system must work for the people who use the door every day. A panel that cannot be read in bright sun, a reader that needs three tries before it answers, or an intercom that cannot be heard over the street will be propped open, and a door propped open holds nothing back.
The release must also work when the power fails. A door that needs power to open is no door at all in a blackout, so the fail position belongs on the order beside the panel, written in plain words. The gate automation guide covers the release that lets a powered gate open by hand, and the same rule holds at the door: the way out must work when the power does not.
Intercoms that carry a voice: audio, video and the call that opens the door
An intercom carries a voice from the door to the person inside, and the call is what opens the leaf. A visitor presses the panel, the person inside hears the call and sees who is there, and the release throws when the button inside is pressed. The call must be clear enough to hear and the picture clear enough to read, because a voice that cannot be understood is no better than a locked door.
Video adds a face to the voice, and the camera beside the panel shows who is standing at the door before the release is pressed. The camera must see the visitor in the light the door actually gets, not only in the light of the showroom, so the position of the panel and the light above it belong on the order beside the leaf.
The flat entrance doors guide covers the doors the intercom opens, and the panel that calls the wrong flat opens the wrong conversation.
Readers, fobs and codes: the keys that are not keys
A reader takes the place of a key, and the fob or card takes the place of the metal. A resident holds the fob to the reader, the reader checks it against the list, and the release throws. A fob that is lost is struck off the list the same day, and the door never needs a new cylinder, because the list is the lock.
Codes work where fobs do not, and a code that is shared too widely is a code that opens the door for everyone. The code for a delivery driver should change when the driver changes, and the code for a cleaner should open only the doors the cleaner needs.
Readers, fobs and codes sit beside the key, not instead of it. The key stays as the override when the power fails or the reader breaks, because the door must open for the person who holds the key when the system cannot answer. The fire door hardware guide covers the lock the key turns, and the reader beside it must work with the lock, not against it.
Who opens which door: residents, staff and the visitor at the gate
A building with many doors needs its entry planned, not piled up. One fob can open the doors that belong together, while each door still takes only the fobs it should. A resident opens the main entrance and their own floor, a cleaner opens the rooms they clean and no others, and a manager opens the whole building.
Visitors take a different path from residents. A visitor calls from the panel, the person inside answers, and the release throws for that one visit.
The entry plan belongs on the schedule with the doors, naming each door, the panel and reader beside it, and the people who may open it. The how to specify security doors guide sets out the columns the schedule needs, and the school security doors guide covers the doors on a site where keys and fobs change hands often.
Fail safe and fail secure: the door when the power goes
Every entry system must answer one question before it is ordered: what does the door do when the power goes? A door that fails safe opens when the power fails, so people can leave, while a door that fails secure stays shut when the power fails, so the line holds. The answer follows the door, not the system, because the escape route needs a door that opens and the store needs a door that stays shut.
A door on an escape route must fail safe, because the way out matters more than the way in. A panic bar to BS EN 1125 throws the latch when pushed, and the bar must work with the reader beside it, not against it, so the leaf opens for a crowd even when the reader has no power.
A door that guards cash or valuables must fail secure, because the line it guards is the reason the door is there. The bank security doors guide sets out the doors for cash and valuables, and the prison security doors guide sets out the doors that hold from the inside. The fail position for each door is written on the order, because a door whose fail position was never decided will fail the way the fitter guessed.
Entry beside the closer: the release that lets the leaf shut
The release that opens the leaf must work with the closer that shuts it, because the two parts share the same door. A release that holds the latch open after the visitor has passed leaves the leaf standing open, and a closer that is too strong fights the release while a closer that is too weak leaves the leaf ajar.
Closers on a fire door need a power size of EN 3 or above to BS EN 1154, and the closer belongs on the order beside the leaf, with the power size chosen for the weight of the leaf it must shut. A door that must stay open through the day takes a hold-open device proved to BS EN 1155, which lets the leaf shut the moment the alarm sounds, and the release belongs on the schedule beside the door.
The fire door closers guide sets out the sizes and the fitting of closers, and the fire door inspection checklist names what each visit should look for.
The system on the inspection round: what each visit must test
The round that looks after an entry system walks every door in turn and tests the panel, the reader and the release on each one. The call is made from the panel, the fob is held to the reader, and the leaf is watched as it opens and shuts, so a fault is found on the round and not by the first visitor who cannot get in.
Each fault is written against the door it belongs to on the same day, with the part and the date beside it, so the repair follows the fault and the door never stands open.
The record that holds the entry faults lives with the building file, in one place, and it is kept current, because a record that is months out of date tells no one which doors have been fixed and which still wait. The security door maintenance checklist covers the doors that must hold both fire and forced entry, and the entry system that guards them belongs on the same round.
One schedule for the whole estate: every reader on one line
Put the entry order together as one list, with a line for every door on the estate and the panel, the reader, the release and the fail position beside each one, so the system that arrives matches the system that was ordered. A schedule that names one panel for the whole estate leaves the fitter to guess which door takes which reader, and a reader fitted to the wrong door opens the wrong leaf.
Check every line of each quotation against the schedule before the order goes out, so no panel, reader or release is left off the price. Anything left off the quotation still has to be bought, and fitting it after the door is in place costs more than ordering it with the door. The security door cost factors guide works through what each step up the scale adds to the price.
The turnstile versus speed gate versus portal guide covers the lobby line beside the doors, and the hospital security doors guide works through the doors on a site where staff, patients and visitors all need a different way in.
| Position | System | Reader | Fail position |
|---|---|---|---|
| Main entrance | Video intercom | Fob and code | Fail safe |
| Flat floor | Audio intercom | Fob | Fail safe |
| Staff entrance | Reader only | Fob | Fail secure |
| Plant room | Reader only | Fob and key | Fail secure |
| Store | Code panel | Code | Fail secure |
An entry system holds only as long as the list behind it, so the panel, the reader, the release and the fail position must all sit on the same schedule.
What is a door entry system?
A panel, reader and release that open a door for the right person and keep it shut for everyone else, with the key kept as the override.
What is the difference between fail safe and fail secure?
A door that fails safe opens when the power fails, so people can leave. A door that fails secure stays shut when the power fails, so the line holds.
Can a fob replace a key?
It takes the place of the key for daily use, and a lost fob is struck off the list the same day. The key stays as the override when the reader cannot answer.
Can an entry system sit on a fire door?
Yes, where the release works with the closer and the panic bar beside it. The leaf must shut on its own and open without a key on the way out.
Who keeps the entry record?