A shop door works harder than most doors in a building. It opens for customers all day, it guards the stockroom where the goods sit, and it must hold fire back on the escape route, all on the same leaf in many shops. The door that fails on one of those jobs leaves the shop open to theft, to fire, or to a claim the insurer will not pay.
The order starts with the shop, not with the door. A high street shop with a glazed front asks for a different door from a warehouse shop with a loading bay, and a shop that trades late asks for different locks from one that closes at five. The hours, the stock and the people who pass through the door decide the rating before the leaf is chosen.
The doors in a shop sit inside one schedule, and an order that names each one plainly gets the right door on the right opening. The retail sector page sets out the buildings these doors guard, and the security shutters and doors for shops page covers the shopfront line in full.
- LPS 1175 B3 / C5 / D10Forced entry ratings, three, five and ten minutes
- FD30 / FD60Fire resistance periods tested to EN 1634-1
- PAS 24Enhanced security doorsets
- TS 007 3-starCylinder and handle sets
The shopfront first: glass, grilles and the door customers use
The shopfront is the face of the shop, and the door in it must let customers see the goods while it keeps thieves out. A glazed door shows the shop floor to the street, so the glass must be proved for the job it does, and the frame and the fixings must be proved with the glass, because a pane in the wrong frame carries no proof at all.
Impact resistance is proved to EN 356, with the top classes set by axe blows: 30 to 50 for P6B, 51 to 70 for P7B, and 70 or more for P8B. A shopfront that faces a busy street takes a higher class than one set back from the pavement, so the class follows the risk the frontage faces, not the glass the catalogue shows first.
A grille behind the glass adds a second line that thieves must cross, and a retractable grille lets the shop open the front by day and close it tight at night. The security shutters versus grilles guide works through the choice, and the security shutters page covers the shutters themselves.
Shutters or a door: what guards the shopfront after hours
A roller shutter covers the whole front after hours, while a security door guards the entrance during the day, so many shops need both. The shutter drops over the glass when the shop closes, and the door holds the entrance while the shop trades, and each one is proved to its own standard, so the order should name both proofs.
A powered shutter is a machine, and BS EN 12453 sets out how it must be made safe to use. Photocells, safety edges and loops each stop the shutter when a person or a vehicle is in its way, and the roller shutter regulations guide sets out the rules the shutter must meet.
A shutter is not a fire door, and a fire shutter is not a security shutter. Where the shop needs both, the fire proof and the forced entry proof sit on separate lines, and the roller shutter cost factors guide works through what each step up the scale adds to the build.
The stockroom door: the leaf thieves try first
The stockroom holds the goods, so its door is the first leaf a thief tries. It takes no glass, it takes a solid leaf, and it takes a rating proved in a live test, because a door that looks strong and was never tested is only a guess. The warehouse security doors guide covers the doors on the building itself, and the loading bay doors guide covers the bays where deliveries arrive.
Forced entry is proved to LPS 1175, with B3 holding three minutes against category B tools, C5 holding five minutes against category C tools and D10 holding ten minutes against category D tools, all under Issue 8.2, dated September 2024. The rating on the order should match the goods behind the door.
The lock, the hinges and the frame carry the rating as much as the leaf does. Ask for a TS 007 3-star set, a 1-star cylinder with a 2-star handle or escutcheon, and hinges to BS EN 1935, with grade 13 carrying 120 kg and grade 14 carrying 160 kg, each through 200,000 cycles, so the hinge is chosen for the weight of the leaf it carries.
Glazing and vision: seeing the shop floor without weakening the door
A vision panel lets staff see the shop floor without opening the door, and a glazed screen lets customers see into the shop from the street. The glass in both must be proved for the job, because a pane that was never tested is a hole in the door, whatever the leaf around it can hold.
Fire rated glazing is proved to EN 1634-1, with FD30 or FD60 and the letters E, EW or EI naming what the furnace measured. The fire rated windows guide covers the windows that share the same wall, and the fire rated glazed doors guide covers the glazed leaves that carry the higher periods.
The frame carries the rating as much as the glass does, because a bullet or a flame that passes the pane still meets the frame. The frame, the beads and the fixings belong on the same line as the glass, so the door that arrives is the door that was tested.
Staff access: keys, fobs and the door that must lock itself
Staff keys multiply in a shop, and every key that leaves with a member of staff is a key in the wrong hands. A fob suits the staff door, because a fob can be stopped when staff leave and a key cannot, and the record should name who holds each fob and each key, so the next manager can see who can open which door.
The stockroom door must lock when it shuts, with no one having to remember to turn the key. A closer that pulls the leaf shut every time and a latch that catches as the door closes do the job on their own, and the security turnstiles guide covers readers, fobs and biometrics in the lane.
One system across the shop keeps the doors together, so one card opens the stockroom, the office and the back door, and one stopped card stops working everywhere at once. The door on the escape route must still release on alarm, so no one is held inside when the alarm sounds, whatever the access system says.
Fire and security on one leaf: FD30 and LPS 1175 together
A shop door often must do two jobs at once. It must hold fire back for its period, and it must resist a forced entry, and a door that must do both needs a proof for each job. Fire is proved to EN 1634-1 and forced entry to LPS 1175, and the two proofs sit on the same schedule line, because a door proved for one job and not the other leaves the shop open on one side.
The period follows the fire load behind the door. Thirty minutes is the period most shop doors carry, and sixty minutes is the period for the doors that guard a compartment wall or a room with a heavier fire load, and a door on a smoke path takes FD30S, with the seal proved to BS EN 1634-3, to Sa for smoke at room temperature and S200 for smoke at 200 degrees Celsius.
How the two proofs sit together is worked through in the fire and security doors dual certification guide. The closer must pull the leaf shut every time, with no fire door taking less than EN 3 to BS EN 1154, and the fire door closers guide covers the sizes and the fitting, while the fire door hardware guide covers the grades and the parts behind a working fire door.
The daily routine: opening, closing and the checks between
A shop runs on a routine, and the doors run on it too. The opening routine lifts the shutter, opens the customer door and switches the alarm off, and the closing routine runs the same steps in reverse, so the shop is never left open by mistake at either end of the day.
The inspection round looks at the closers, the seals, the locks and the glazing, and each fault goes on the record the day it is found. The fire door inspection checklist names what each round should look for, and the gap round a fire door leaf must stay at 4 mm, because a wider gap lets fire and smoke past whatever the rating on the leaf says.
Keeping a rating valid means keeping the door as it was proved, with the same leaf, the same frame and the same hardware the test report names. A seal that has come away or been painted over leaves the gap open, so check the seals first on every round, and the keeping an LPS 1175 rating valid guide sets out what breaks a rating.
One schedule for the whole shop: every door on one line
Write the enquiry as one schedule with a line for every door in the shop, and put the position, the fire period, the forced entry rating, the glazing and the hardware on each line, so the door that arrives is the door that was proved. The periods for the shared parts of a shop are named in the fire door regulations for retail guide.
Put the quotes side by side and check each line, because the quote that leaves a seal or a closer off the list is not cheaper, only shorter, and the missing line is paid for later. The security door cost factors guide works through what each step up the scale adds to the build, and the how to specify security doors guide runs through the same discipline column by column.
File the test reports and the inspection routine with the doors when they arrive, so the record covers the whole life of every door in the shop.
| Position | Door | Rating | What to check |
|---|---|---|---|
| Shopfront | Glazed security door | LPS 1175 B3 | Glass, frame, closer |
| Stockroom | Solid security door | LPS 1175 C5 | Lock, hinges, closer |
| Back door | Fire and security door | FD30 + B3 | Seals, gaps, lock |
| Escape route | Fire door | FD30S | Seals, closer, release |
| Plant room | Fire door | FD60 | Seals, closer, latch |
A shop door must open for customers, hold thieves out and hold fire back, so the rating, the glazing and the locks must all sit on the same schedule.
What rating do retail security doors need?
The opening sets it. LPS 1175 B3, C5 or D10 for forced entry, with the minutes and the tool set behind each grade, and FD30 or FD60 where the door guards an escape route or a compartment wall.
Do shopfront doors need fire rated glazing?
Where the door sits on an escape route or a compartment wall, yes. Fire rated glazing is proved to EN 1634-1 with the frame and the fixings, and the period follows the fire load behind the door.
Shutter or security door for the shopfront?
A shutter covers the whole front after hours and a door guards the entrance during the day, so many shops need both. The shutter is proved to BS EN 13241 and the door to LPS 1175 or PAS 24.
Who holds the keys to a shop?
Staff take a fob or a key for the doors they use, and the record names who holds each one. A fob can be stopped when staff leave, and a key that leaves with a member of staff should be treated as a key in the wrong hands.
Who checks retail security doors?
The person who runs the shop, on the routine the fire risk assessment sets. Each round looks at the closers, the seals, the locks and the glazing, and each fault goes on the record the day it is found.