Security Windows for Schools Explained

School windows that must hold fire, resist forced entry and vandalism, and still let light and air in: one tested assembly, from classroom to corridor.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed across the UK
Prefer to talk?+44 7352 267239

Get a free project quote

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

A school window has to do more than let light in. It must hold fire long enough for a corridor of children to leave, resist a forced entry from outside, stand up to daily knocks from inside, and still open for air on a warm afternoon. A window that does one of those jobs and fails another has not done the job it was bought for, and a school that orders windows one job at a time will end up with windows that fail in different ways in different rooms.

The answer is one tested assembly for each opening: glass, frame, beads, seals and fixings tested together, with the evidence naming all of them. A pane that carries a fire class in one frame carries no rating at all in a different frame, because the test never covered that combination. The same rule holds for security: a rating belongs to the complete tested assembly, not to the glass alone. Our fire rated windows guide sets out how glass, frame and beads are tested together, and our schools sector page covers the doors and gates that guard the same buildings.

The sections below work through the jobs one by one: fire, forced entry and vandalism, escape, safeguarding, the frame that holds the glass, the rooms that need more, and the order itself. Our education sector page covers the buildings a school estate holds, and our fire door regulations for schools guide covers the doors that stand beside these windows in the same corridors.

  • EN 1627Resistance classes RC1 to RC6 for windows, doors and shutters
  • EI 140 / 180CTemperature rise limits on the safe side of a fire window
  • LPS 1270Security glazing standard for windows and screens
  • BS EN 1634-1Fire resistance test for doors and windows

What a school window must do: light, air, escape and resistance

Classrooms need daylight. Children learn better in rooms with natural light, and a classroom with small, high windows that admit little light is a classroom that needs electric light all day. At the same time the window must open for air, because a classroom full of children warms quickly and stale air makes concentration harder. Light and air are the first two jobs, and they are the jobs that pull against the other two: a window that opens wide for air is a window that can be climbed through, and a window that admits light through a large pane is a window with a large pane to break.

The specification that serves a school names all four jobs for each opening. A ground floor classroom window needs a security rating and a restrictor that limits how far it opens. A first floor window needs the same rating where it can be reached from a flat roof, a canopy or a low wall. A corridor window needs a fire rating where the corridor is a protected route. A library window needs a quiet closer and a pane that holds the compartment line. Write the schedule first, one line per opening, then order against it, so every window is bought for the opening it stands in.

Fire rated glass in a classroom: E, EW and EI

A fire rating to EN 1634-1 tests flame and heat, and the letters name what the window holds back. E holds back flame and hot gases. EW holds back flame, hot gases and some radiant heat. EI holds back flame, hot gases and heat, with a limit on temperature rise on the safe side: an average of 140 degrees Celsius and a maximum of 180 degrees Celsius. Escape routes usually need EI because children pass close to the window, and a pane that lets heat through can stop an escape even while it holds back flame.

The rating belongs to the window as tested: glass, frame, beads and seals together. A window rated EI30 in a 60 minute wall gives a 30 minute opening, and a window rated EI60 in a 30 minute wall gives a 30 minute opening too. The wall and the window are one decision, and the fire strategy names the period for each opening. Our fire rated glazed doors page covers the same letters on a doorset, and our fire rated glass cost guide covers the glass behind the order in factors-only form.

Smoke needs its own evidence. A fire rating to EN 1634-1 tests flame and heat, and smoke passes through a cold gap long before heat reaches the seals. Where the fire strategy asks for smoke control, the window needs a smoke rating to BS EN 1634-3, Sa or S200. A fire rating on its own does not prove smoke control, so ask for the smoke evidence by name.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Forced entry and vandalism: the rating behind the glass

A school window must resist two kinds of attack: a forced entry from outside, and vandalism from inside and outside. The two are not the same. A forced entry is a deliberate attempt to get in, with tools and time. Vandalism is a thrown stone, a kick, or a chair pushed through a pane by a pupil who is angry or bored. A window that resists a forced entry may still fail under a single heavy impact, and a window that resists impact may still fail under a sustained attack with tools.

EN 1627 sets resistance classes RC1 to RC6 for windows, doors and shutters, and the class names the tools and the time the assembly resists. LPS 1270 is the security glazing standard for windows and screens, and it rates the glazing itself. The class belongs to the complete tested assembly, not to the pane alone, so a rated pane in an untested frame is not a rated window. Ask for the test report, not the class alone, and ask for the exact window, its frame detail and its configuration.

Ground floor windows need the most. A window at ground level can be reached by anyone walking past the building, and it can be attacked without a ladder and without being seen from inside. A window on an upper floor needs the same rating where it can be reached from a flat roof, a canopy, a low wall or a climbing frame. Walk the building from outside and note every window a person can reach, then rate those windows for the attack they could face.

Opening windows and the escape route

An openable window has a sash, hinges and a handle, so its rating rests on the sash being closed when fire breaks out. A sash that is left open has no fire performance at all, whatever its certificate says. A window held open for air needs a release that closes it when the alarm sounds, just as a fire door held open needs a hold-open device to BS EN 1155 that releases the door when the alarm sounds.

Restrictors limit how far a window opens, and they serve two jobs at once: they stop a child climbing out, and they stop an intruder climbing in. A restrictor that can be undone by a child is a restrictor that will be undone, so the release should need a key or a tool that staff hold. Check the restrictor at every inspection, and write down that it worked. A window that opens wide for air in a classroom where small children sit needs a restrictor that holds.

Escape windows need their own check. A window that serves as an escape route must open in one action, without a key and without a tool, and the opening must be large enough for the people who will use it. A window that needs a key to open is a window that traps the children behind it. The fire risk assessment names which windows are escape windows, and the routine should check them as often as the doors.

Safeguarding: who can see in, who can get in

Safeguarding shapes the glass as much as the frame. A classroom window lets a teacher see the corridor and lets the corridor see the classroom, and that visibility is part of how a school keeps children safe. A window with a glazed panel lets staff see whether a room is occupied before opening the door, and lets children see whether the corridor is clear before they leave. The glass must carry the same fire rating as the frame where the fire strategy asks for it, with beads and seals tested as part of the assembly.

Visibility cuts both ways. A ground floor window that lets staff see out also lets a stranger see in, and a window beside an entrance lets a visitor watch the corridor before they are admitted. Obscured glass, a high sill, or a window that starts above head height can keep the light while cutting the view in, and the choice should be made room by room with the safeguarding lead. Our schools sector page covers lockdown and intruder resistance at entrances, and the windows beside those entrances need the same thought.

Visitor entrances need windows that admit light and resist attack at the same time. A glazed entrance screen lets reception see who is at the door before it is opened, and a rated screen holds while the door is checked. A screen that is not rated is a screen that fails at the first blow, and the entrance behind it is open. Rate the screen for the attack it could face, and order it as one assembly with the door beside it.

Frames, beads and fixings: the assembly that holds the glass

The frame is half the window. A steel frame holds a heavy pane and resists a forced entry, a timber frame suits a listed building or a conservation area, and an aluminium frame suits a large glazed screen. The frame must carry the same rating as the glass, because a rated pane in a frame that fails early is a window that fails early. Ask for the frame, the beads, the seals and the fixings as one assembly, and ask for the test evidence naming all of them.

Beads hold the pane in the frame, and a bead swapped on site for a neater one takes the window outside its evidence. Fit only the bead system the test evidence names, and check that the beads are fixed all the way round the pane. Fixings hold the frame in the wall, and a frame fixed into a partition that was never built to hold it will move when the window is used. A rated window in an unrated wall gives an unrated opening.

Seals close the gap between the pane and the frame, and between the frame and the wall. Intumescent seals close the gap in a fire, expanding at roughly 200 to 250 degrees, and a seal that has been painted over cannot expand. Tell the decorators that seals are never to be coated, and check the seals after any painting work in the building.

The bead that holds the glass: fixings a school window cannot do without

A school window is opened, shut, leaned on and cleaned every day, and the bead that holds the glass takes more of that life than any other part. An internal bead sits on the room side of the frame, so it cannot be prised from outside, and a bead that has been screwed or clipped in place should be checked for fixings that have worked loose. A bead that a pupil can lift with a fingertip has already failed, and a pane that can be lifted out of its frame is no barrier at all, whatever the glass rating says.

Check the fixings into the wall on the same visit as the bead. A frame fixed into solid masonry holds differently from a frame fixed into a stud wall, and a fixing that has loosened in a soft block wall will let the frame move every time the sash is shut. Look for fixings that have pulled, packers that have slipped, and sealant that has cracked away from the frame, because a frame that moves lets the sash sit short of its seal and lets draughts and rain through.

Read the glass rating whole before ordering. LPS 1270 grades a pane with three digits for hand, arm and body passage, so a pane that stops a hand may still let an arm through, and all three digits belong on the schedule. For manual attack on glass, EN 356 runs from P1A to P8B, and the top classes are set by axe blows: 30 to 50 for P6B, 51 to 70 for P7B, and 70 or more for P8B. EN 1627 sets resistance classes RC1 to RC6 for windows, doors and shutters, so ask which standard tested the glass and read the rating whole. Our fire rated windows guide covers how glass, frame and beads are tested together as one assembly.

Ground floor glass: the rooms where the rating rises

Ground floor rooms ask more of a window than rooms upstairs. A classroom at ground level faces the playground, the car park and the street, and the glass there meets balls, bags and hands every day, so the rooms at ground level take the higher rating and the rooms above take the lower one. A science room, a hall and a sports changing room ask for more again, because the activity inside them throws harder and more often. Put the rating on the schedule beside the room, not beside the building, so a ground floor classroom is never fitted with the glass meant for a first floor office.

Safeguarding shapes the glass as much as resistance does. A window that lets staff see into a room from the corridor keeps pupils safe, and a vision panel at the right height does that job without opening the room to the corridor. One-way vision, blinds and manifestation all change what can be seen from outside, and the choice belongs on the schedule beside the rating, because a pane that is easy to see through from the playground is a different pane from one that is not. Our fire door regulations for schools guide covers the doors that share the same corridors.

Part What to check Why it matters
Bead Internal bead, fixings tight A loose bead lets the pane out
Frame fixings Fixings suit the wall, packers firm A moving frame breaks the seal
Glass rating LPS 1270 digits, EN 356 class A partial rating proves nothing
Escape opening Opens fully, stays open, no key A stuck sash blocks the route

File the test report, the classification and the schedule with the order, so the next specifier can see which standard proved which window, and which room each rating belongs to.

Ground floor, first floor and the rooms that need more

Not every school window needs the same rating. A ground floor classroom window needs a security rating and a restrictor. A first floor window needs the same where it can be reached from a roof or a canopy. A corridor window needs a fire rating where the corridor is a protected route. A plant room window needs a higher fire rating, because the room behind it holds a higher risk. A library window needs a quiet sash and a pane that holds the compartment line.

Science laboratories, design workshops and kitchens need more than a classroom window. A laboratory holds chemicals and gas, a workshop holds tools that can break glass, and a kitchen holds heat and steam. The windows in those rooms need a rating that suits the room behind them, and the fire strategy names the period for each opening. Our types of security doors guide sets out the range of doors a school may need, and the same habit serves the windows: write the schedule room by room, then order against it.

Sports halls and assembly halls need windows that take impact. A ball struck at a window, a pupil pushed against a pane, or a chair knocked into the glass are all part of daily use in a hall. The glazing in those rooms should resist impact as well as forced entry, and the frame should hold the pane when it is struck. A pane that breaks under a ball is a pane that will be broken often, and each break is a week with a boarded window.

What the order should name for a school window

Ordering windows for a school is a specification exercise, not a shopping exercise. The order should name the rating in full, fire and security together where the opening needs both, and it should name the glass, the frame, the beads, the seals and the fixings as one assembly. The security side needs its own evidence where the window must also resist attack: a class to EN 1627 or a rating to LPS 1270, on the whole window, not on the pane alone.

Finally, order the evidence with the windows. The test report, the classification and the hardware schedule should arrive with the assembly, and the handover pack should name the inspection routine the school will follow. A school that files the evidence on the day the windows arrive has a record it can use for the whole life of the estate. Our how to specify security doors guide covers the same discipline for rated doors, and our dual certification guide works through how fire and security sit on one assembly.

Room Window position What it must do What to check
Classroom, ground floor External window Hold fire, resist forced entry, open for air Rating, restrictor, seals
Corridor Glazed screen or window Hold the corridor as a protected route EI rating, beads, smoke seals
Library Reading room window Close quietly, hold the compartment line Sash, latch, hold-open release
Entrance Glazed screen beside the door Let reception see out, resist attack Rating, frame, fixings
Plant room and store High-risk room window Hold a higher-risk fire inside its own room Higher rating, seals, gaps

In a school, a window is not a hole in the wall with glass in it. It is a tested assembly that must hold fire, resist attack and still let a classroom breathe.

Do school windows need a fire rating?

They need the rating the fire strategy names for their position. A window in a corridor that serves as a protected route needs a fire rating, usually EI because children pass close to it, while a window in an external wall that is not part of a compartment line may need none. The fire strategy names the period for each opening.

What is the difference between E, EW and EI for a school window?

E holds back flame and hot gases, EW holds back flame, hot gases and some radiant heat, and EI holds back flame, hot gases and heat, with a limit on temperature rise on the safe side: an average of 140 degrees Celsius and a maximum of 180 degrees Celsius. Escape routes usually need EI because children pass close to the window.

Can one window carry a fire rating and a security rating?

Yes, where both sets of evidence cover the same construction. The fire classification comes from a test to EN 1634-1 and the forced entry rating from a test to EN 1627 or LPS 1270, and the two must be proved on the same window. A pane that carries a fire class in one frame carries no rating at all in a different frame.

How do window restrictors fit with fire escape?

A restrictor limits how far a window opens, so it stops a child climbing out and stops an intruder climbing in. A window that serves as an escape route must open in one action, without a key and without a tool, so the fire risk assessment names which windows are escape windows and the routine checks them as often as the doors.

What should a school window schedule name for each opening?

The room, the position, the fire rating, the security rating where one is needed, and the glass, the frame, the beads, the seals and the fixings as one assembly. The schedule should travel with the order, and the test report, the classification and the hardware schedule should arrive with the windows.

Phased rooms: the order that keeps lessons running

A school cannot close a classroom block for a window programme, so the work runs room by room while lessons continue next door. The order of rooms matters more than the speed of the work. Start with the rooms the school can empty without moving a class, then move to the rooms that need a timetable change. A room that is worked on while pupils sit in it is a room where the work stops every few minutes, so plan the sequence with the school, not around it.

Each room should be finished and handed back before the next room is opened up. A half finished room leaves a window without its bead and fixings in place, and a window without its bead is a window that cannot hold its glass. The security windows page sets out how the glass, frame, beads and fixings work as one assembly, and the same rule holds during a retrofit. Nothing should be left overnight with a pane held in by a temporary fix.

Escape routes stay open through the whole programme. A window that serves as an escape route must open in one action, without a key and without a tool, so the route must be checked at the end of each working day, not only at the end of the job. Where a room has only one escape window, that window is replaced last in the room, after the other windows are finished and signed off. The fire strategy names which windows are escape windows, and the day plan should name them too.

Safeguarding shapes the working day as much as the timetable does. Workers should not pass through rooms where pupils are taught, and tools and glass should not sit in corridors pupils use between lessons. The school names the routes workers may use and the times they may use them, and the work stops while pupils move between rooms. A window programme that respects those routes runs slower on paper and faster in practice, because nothing has to be cleared away in a hurry.

Handover checks: what the school signs off room by room

Handover happens room by room, not at the end of the whole job. When a room is handed back, the school checks the window it has just received while the work is still fresh and the team is still on site. A fault found in that room is fixed the same day, while a fault found at the end of the job waits for a return visit. The maintenance checklist gives the same habit for doors, and it works for windows too.

Room check What to look at What it proves
Restrictor Opens to the set limit and no further The window cannot be opened wide enough to climb through
Escape window Opens in one action, without a key and without a tool The escape route works on the day it is needed
Beads and fixings Beads seated, fixings tight, no gaps at the corners The glass stays in the frame under attack
Seals and sash Seals touch all round, sash shuts and latches Draughts and rattles do not follow the new window

The evidence pack travels with the handover, room by room. The test report, the classification and the hardware schedule for the windows in that room should be filed when the room is signed off, not collected at the end of the job. The education sector page sets out the standards that apply across a school estate, and the handover pack is where that evidence is kept. A school that files the evidence room by room has a record it can use for the whole life of the estate.

Specifying windows for a school?Send the window schedule and the fire strategy for a tested assembly quotation.
Get a free quote

Related

More in guides for specifiers

10 mistakes when specifying certified security doors 10 steps to specify an LPS 1175 door Acceptance and Snagging of a Security Door or Barrier Job Access Control Doors Acoustic Doors: Ratings and Specification After a Forced Entry Attempt: Checking a Security Door Airport Security Doors Anti-Ligature Doors for Mental Health Wards Anti-Ram Bollards Anti-ram gates and barriers: protecting vehicle entrances Arcade Security Doors Explained Automatic Doors Automatic Gates Cost Factors Automatic Vehicle Barriers Ballistic Panels Bank Security Doors Bingo Hall Security Doors Explained Blast doors: glazed vs solid and how they are rated Blast protection window film: what it does and what it cannot do Blast resistant windows: what drives the cost and how to specify them Bollard Cost Factors Explained Bollard regulations in the UK: spacing, height and depth Bookmaker Security Doors Explained Builders Merchant Security Doors Bullet Resistant Glass Cost Factors Bullet resistant glass ratings explained: BR1 to BR7 and SG classes Bullet resistant vs bulletproof glass: what the difference means Buying Security Doors and HVM Through Public Frameworks Car Park Security Doors Explained Car Showroom Security Doors Casino Security Doors Explained CDM 2015 Duties When Security Doors, Shutters or HVM Are Installed Cinema Security Doors Cleanroom Doors Cold Store Doors College Security Doors Commissioning, Handover and the O&M Manual for Security Doors and HVM Communal entrance doors for flats: Secured by Design and what to specify Community Centre Security Doors Control Room Doors Court Security Doors Crash Rated Fences and HVM Fencing Explained Data centre physical security: doors, glazing, HVM and shielding by zone Dental Practice Security Doors Depot Security Doors Explained Door Entry Systems Due Diligence When Selecting Vehicle Security Barriers Emergency Exit Doors EMP Shielding Cost Factors Explained Exhibition Centre Fire Door Rules Exhibition Centre Security Doors Factory Security Doors Faraday cage vs RF shielded room: what a business needs FB4 vs FB6 vs FB7: how to choose a ballistic rating Fire and security doors: how dual certification works Fire Compartmentation Fire Curtains Fire Door Certification Fire Door Closers Explained Fire Door Cost Factors Fire Door Duties of the Accountable Person Fire Door Gaps Fire Door Hardware Explained Fire door inspection checklist for steel and timber doors Fire Door Maintenance Fire Door Regulations Care Homes Fire Door Regulations for A and E Departments Fire Door Regulations for Airports Explained Fire Door Regulations for Bowls Clubs Fire door regulations for commercial buildings in the UK Fire Door Regulations for Dialysis Centres Fire Door Regulations for Hockey Clubs Fire Door Regulations for Hospitals Explained Fire Door Regulations for Offices Explained Fire Door Regulations for Operating Theatres Fire Door Regulations for Retail Explained Fire Door Regulations for Schools Explained Fire Door Regulations for Snooker Clubs Fire Door Regulations for Stadiums Fire Door Regulations for Student Accommodation Fire Door Regulations for Warehouses Fire Door Regulations Leisure Centres Fire Door Regulations Restaurants Fire Door Remediation Programme for Housing Providers Fire Door Rules for Badminton Clubs Fire Door Rules for Bingo Halls Fire Door Rules for Bookmakers Fire Door Rules for Bowling Alleys Fire Door Rules for Car Parks Fire Door Rules for Car Showrooms Fire Door Rules for Cinemas Fire Door Rules for Climbing Centres Fire Door Rules for Colleges Fire Door Rules for Community Centres Fire Door Rules for Cricket Clubs Fire Door Rules for Dental Practices Fire Door Rules for Depots Explained Fire Door Rules for Golf Clubs Fire Door Rules for GP Surgeries Fire Door Rules for Gyms Explained Fire Door Rules for Ice Rinks Fire Door Rules for Maternity Units Fire Door Rules for Mental Health Units Fire Door Rules for Museums Fire Door Rules for Oncology Units Fire Door Rules for Opticians Fire Door Rules for Pawnbrokers Fire Door Rules for Petrol Stations Fire Door Rules for Pharmacies Fire Door Rules for Ports Fire Door Rules for Post Offices Fire Door Rules for Prisons Fire Door Rules for Rehabilitation Centres Fire Door Rules for Self Storage Fire Door Rules for Shopping Centres Fire Door Rules for Squash Clubs Fire Door Rules for Supermarkets Fire Door Rules for Swimming Pools Fire Door Rules for Tennis Clubs Fire Door Rules for Theatres Fire Door Rules for UK Arcades Fire Door Rules for UK Casinos Fire Door Rules for UK Hospices Fire Door Rules for Walk-in Centres Fire Door Signage Fire Door Vision Panels Fire Doors and Gateway 2 in Higher-Risk Buildings Fire Rated Glass Cost Explained Fire Rated Sliding Doors Explained Fire Rated Windows Cost Factors Fire Rated Windows Explained Fire Safety Enforcement Notices and Fire Doors: What the Responsible Person Must Do Flat Entrance Doors: PAS 24 and Fire Rated Forced Entry vs Ballistic vs Blast: Which Rating a Site Needs Garage Security Doors Explained Gate Automation Explained Golden Thread Records for Fire Doors GP Surgery Security Doors Explained Gym Security Doors Explained High Speed Doors HMO Fire Doors Hospice Security Doors Explained Hospital Security Doors: Wards, A&E, Plant Hospital Security Gates Hotel Fire Doors Hotel Security Doors How to choose HVM bollards: fixed, shallow mount, removable and automatic How to keep an LPS 1175 door rating valid after installation How to Specify Fire Doors in a Housing Tender How to specify security doors: a checklist for architects How to Verify a Secured by Design Listing How to Verify an LPS 1175 Certificate on Red Book Live How to Write an Operational Requirement for Physical Security HVM planters and street furniture: protection that blends in In-Service Care of Vehicle Security Barriers Installation Handover: LPS 1175 Doors and PAS 68 Barriers Intumescent Seals ISO 16933 explained: EXV and SB classes and hazard ratings ISO 22343 vehicle security barriers explained Keeping a Dual-Certified Fire and Security Door Valid in Service Laboratory Security Doors Layered Security for a Site: Deter, Detect, Delay, Mitigate, Respond Lead Times and Programme Risks for LPS 1175 Doors Leisure Centre Security Doors Library Security Doors Listed Building Fire Doors Loading Bay Doors Explained Lockdown and Access Control Hardware on an LPS 1175 Door LPS 1175 Gates and Grilles Explained LPS 1175 Issue 8 explained: from SR1 to SR8 to A1 to H20 LPS 1175 Roller Shutters LPS 1175 vs ASTM F2781 and Other US Ratings Explained LPS 1175 vs EN 1627: how UK and European burglar resistance ratings compare LPS 1175 vs PAS 24: which security standard does your door need? LPS 1175 Windows and Walling Explained Martyn’s Law and Places of Worship: What a Buyer Checks for Doors and Entry Control Martyn’s Law Enhanced Tier: Physical Measures and the Specifier Brief Martyn’s Law Standard Tier: Procedures, Doors and Shutters Martyn’s Law Timeline and the SIA Regulator Martyn’s Law: what premises must do and which physical measures to consider Master Key Systems MRI and RF shielded rooms: how they work and what to specify Museum Security Doors NPSA Catalogue of Security Equipment (CSE) Explained NPSA Forced Entry and Blast Guidance for Government Sites NPSA Guidance on Lockdown and Marauding Attack: What It Asks of Doors and Entrances Office Security Doors Optician Security Doors Explained Panic Hardware PAS 24 requirements for doors and windows explained PAS 68 Bollard Foundations Explained PAS 68 bollards: ratings, spacing and cost factors PAS 68 vs IWA 14 vs ISO 22343: hostile vehicle mitigation standards explained Pawnbroker Security Doors Explained Pedestrian Gates Petrol Station Security Doors Pharmacy Security Doors Planning Permission for Security Shutters, Gates and Bollards on Commercial Premises Plant room doors: fire, security and ventilation requirements Plant Room Fire Doors Port Security Doors Post Office Security Doors Explained Powder coating vs galvanising vs paint for steel Preliminary Market Engagement for Security Doors and HVM Prison Security Doors Programming a Security Door and Barrier Package on a Live Site Public-Sector Tender Response Checklist for Security Door and HVM Supply Reading a PAS 24 and SBD Door Test Report Regulation 38 Fire Safety Information at Handover for Fire-Rated Security Doorsets Replacing Security Doors in an Occupied Building Restaurant Security Doors Retail Security Doors Revolving Doors RF shielding standards and how shielded rooms are tested Rising Bollard Cost Factors Road Blocker Cost Factors Explained Road Blockers Explained Roller Shutter Cost Factors: What Drives the Price Roller shutter regulations in the UK: safety and maintenance Safe room and panic room doors: specification basics Safety Duties for Powered Doors, Gates and Barriers on Commercial Sites School Security Doors Sectional Doors Secured by Design explained: is it mandatory for doors? Secured by Design vs NPSA vs LPCB: Which One You Need Security Door Locks Security Door Maintenance Checklist Security Doors and Access for Everyone: What Approved Document M Asks Security Doors for A and E Departments Security Doors for Badminton Clubs Security Doors for Bowling Alleys Security Doors for Bowls Clubs Security Doors for Climbing Centres Security Doors for Cricket Clubs Security Doors for Dialysis Centres Security Doors for Golf Clubs Security Doors for Hockey Clubs Security Doors for Ice Rinks Security Doors for Maternity Units Security Doors for Mental Health Units Security Doors for Oncology Units Security Doors for Operating Theatres Security Doors for Rehabilitation Centres Security Doors for Snooker Clubs Security Doors for Squash Clubs Security Doors for Swimming Pools Security Doors for Tennis Clubs Security Doors for Walk-in Centres Security Doors West Midlands Explained Security Fencing Security Gates Cost Factors Explained Security shutters vs high performance roller doors Security shutters vs retractable grilles: which suits retail and commercial openings? Security Turnstiles Explained Security Window Film Self Storage Security Doors Server Room Doors Explained Shopping Centre Security Doors Smoke Control Doors Explained Smoke Curtains Specification Mistakes When Mixing LPS 1175, PAS 24 and SBD in One Tender SR2 vs SR3 vs SR4 security doors: choosing the right LPS 1175 level Stadium Security Doors Steel Door Frames Steel vs aluminium security doors: strength, ratings and looks Steel vs timber fire doors: which suits your building? Student Accommodation Security Doors Substation doors: security, ventilation and specification Supermarket Security Doors Telescopic Bollards Tender Evaluation Criteria and Scoring for Security Doors and HVM The Scope of a Maintenance Contract for Security Doors and Barriers Theatre Security Doors Thermal and Weather Performance of External Security Doorsets Thermally broken steel security doors: U-values and certification Traffic Calming as Hostile Vehicle Mitigation Transport hub security requirements Turnstile Cost Factors Explained Turnstile vs speed gate vs security portal: choosing entrance control Types of security doors for commercial buildings University Security Doors Explained Vehicle Dynamics Assessment: What It Tells the Buyer Before a Barrier Is Specified Warehouse Security Doors Explained Warehouse Security Gates Warranty, Defects Liability and Guarantees for Security Doors and Barriers What affects the cost of a bullet resistant door What affects the cost of a high-security door in the UK Window Security Bars View all →