A fire door only works when it is shut, and it only stays shut when someone looks after it. The closer pulls the leaf to, the seals fill the gap round it, the hinges carry its weight, and each of those parts wears a little every time the door moves. A door that was fitted right can drift out of proof in a year of daily use.
Maintenance is the routine that catches that drift. It is not a repair after something breaks; it is a round that walks the building, looks at every fire door in turn, and writes down what needs doing before the fault grows.
The doors that need the routine are set out in the commercial buildings fire door regulations guide, and the fire door inspection checklist names what each visit should look for.
- EN 1634-1Fire resistance test for doorsets
- FD30 / FD60Fire resistance periods, 30 and 60 minutes
- BS EN 1154 EN 3Minimum closer power size on fire doors
- 4 mmGap round a fire door leaf
The door that must shut on its own: what maintenance keeps working
A fire door has one job above all others: to shut on its own, every time, without a hand on it. The closer does that work, the latch catches as the leaf meets the frame, and the seals fill the gap that is left. When any of those three fails, the door stands open, and a door that stands open holds nothing back.
The leaf itself takes the knocks of daily use. Trolleys catch the bottom edge, chairs push against the face, and the frame takes the vibration of every closing. A leaf that has swollen in damp air drags on the floor, and a leaf that has shrunk in dry heat leaves the gap wide.
Start the routine with the doors that move most. Corridor doors, stair doors and the doors on busy escape routes are opened hundreds of times a day. The doors on plant rooms and stores move less, so they are checked on the same round but with less urgency, and the plant room door requirements guide covers the doors on the rooms that feed a building.
Closers: the part that fails first
The closer is the part that fails first on a fire door, because it works on every single closing. The arm bends, the spring weakens, the oil leaks, and the leaf that used to shut in three seconds now takes five, or never quite reaches the latch.
No fire door takes less than EN 3 to BS EN 1154, with the power size chosen for the leaf that is fitted. A heavy leaf needs a stronger closer, and a light leaf needs a gentler one, because a closer that is too strong slams the leaf against an old frame and a closer that is too weak never finishes the job. The power size belongs on the order beside the leaf.
Test the closer by opening the leaf fully and letting it go. If the leaf stops short, the closer needs adjusting; if the arm is bent or the body leaks, the closer needs a new one. The fire door closers guide covers the sizes and the fitting.
Seals and gaps: the small parts that hold fire and smoke back
The gap round a fire door leaf must stay at 4 mm, because a wider gap lets fire and smoke past whatever the period on the leaf says. The gap is measured at the top and both sides, and it is checked with a gauge on every round, because a frame that has moved with the seasons can open the gap without anyone noticing.
Intumescent seals expand at around 200 to 250 degrees, and they sit in the groove in the frame or the edge of the leaf. A seal that has come away, hardened with age or been painted over leaves the gap open, and a seal that has been cut back to make a door shut easier is a seal that no longer works.
Smoke takes a separate seal, proved to BS EN 1634-3, with Sa for smoke at room temperature and S200 for smoke at 200 degrees Celsius. A door on a smoke path takes FD30S, and the smoke seal must be the one the test report names. The smoke control doors guide covers the doors that hold smoke back while people move past them.
Hinges, latches and locks: the hardware that wears with the leaf
Hinges carry the leaf through every opening, and they wear with the weight they carry. Hinges to BS EN 1935 carry the leaf through 200,000 cycles, with grade 13 rated for 120 kg and grade 14 for 160 kg, so the hinge should be chosen for the weight of the leaf it carries. A hinge that sags lets the leaf drag, and a leaf that drags never shuts on its own.
The latch must catch as the leaf meets the frame, because a leaf that rests against the frame without latching can be pushed open by the pressure of a fire. Check the latch by pushing the leaf gently from the corridor side; if it moves, the latch or the keep needs adjusting, and the fire door hardware guide covers the grades and the parts behind a working fire door.
Locks on a fire door must still let people out without a key, because the escape route matters more than the lock. A TS 007 3-star set, made of a 1-star cylinder with a 2-star handle or escutcheon, keeps the lock proved.
Glazing and vision panels: the glass that must stay proved
Glass in a fire door is proved as part of the doorset, with the pane, the beads and the fixings all named in the test report. When a pane is fitted to a leaf that was tested solid, the doorset is no longer the one that was tested, and the proof is gone until a new test covers the glazed leaf. The fire rated glazed doors page covers the glazed leaves that carry the higher periods.
Check the glazing on every round. Look for cracks in the pane, beads that have come loose, and putty or sealant that has dried and fallen away. A cracked pane must be swapped for glass of the same proof, with the same beads and fixings.
A vision panel is a small window in the leaf, and it earns its place by letting staff check the corridor before they open the door. The pane must be the glass the test report names, set in the beads the report names, and cut to the size the report allows. A bigger pane than the report allows leaves the leaf short of timber, so the panel size is written on the order with the leaf, not decided on site.
The monthly walk and the yearly check: how often each part is looked at
Once a month, walk every corridor and stair in the building and stop at each fire door. Push the leaf open and let it go, watch it meet the frame, and run a finger along the seal to feel whether it is soft or has hardened. A door that fails any of those checks goes on the list before the walk ends.
Once a year, look deeper. Take the covers off the closers, check the hinge screws for wear, measure the gaps with a gauge, and test every hold-open device to BS EN 1155 to make sure the door shuts the moment the alarm sounds. The yearly check is the one that finds the slow faults, and the fire door regulations schools guide works through the periods for a school, where the yearly check falls in the holidays.
Doors that move most are checked most. The doors on corridors, stair cores and escape routes are walked every month. The fire door regulations hospitals guide covers the periods for a hospital, and the fire door regulations offices guide covers them for an office.
A fire door rarely fails in a day. It drops a millimetre in a year, the gap round it grows a little wider, and the closer pulls a little less hard each month, so slowly that nobody on the round notices the change. The door still shuts, the room still looks right, and the proof quietly slips away while the door is in daily use. Drift is found by measuring, not by looking, and the handover record is the measure it is judged against.
How much drift can a gap take before the door fails to hold?
The handover record names the gap round the door on the day it was fitted, and every later measure is read against that number. A gap of 4 mm round the door is the measure the round works to, and a gap that has grown past it is written down even when the door still shuts, because the gap is what fire and smoke travel through first.
The closer weakens in the same slow way. It still pulls the door to, but it takes longer to do it, and a closer that takes longer each month will one day stop short of the latch. A closer is sized by the weight it must pull, and the fire door closers guide matches power size to door weight before the order is written.
Hinges carry the same slow load. A hinge that has worn lets the door sit a fraction lower, and the lower edge drags on the floor while the top gap grows. Hinge grades are checked before the order goes out, and the fire door hardware guide lists the grades that suit the weight of the door.
Drift is measured against the handover record and not against memory
Memory says the door has always shut like that, and the record says otherwise. The round writes the gap, the closing time and the state of the seal beside the handover number, so a small change seen three times in a row becomes a repair before it becomes a failure. The round follows one list from the first door to the last, and the fire door inspection checklist puts the gap, the closing time and the seal on it.
Seals age out of sight. An intumescent seal swells as the heat rises, closing the gap at around 200 to 250 degrees, so a seal that has hardened or pulled away from its groove leaves the gap open at the moment it matters most. The intumescent seal on the order must match the one the report names, and a seal with paint on it or a cut edge is noted on the round sheet that same day.
A door that carries both proofs is walked on its own round, and the security door maintenance checklist lists the checks that keep each proof true for the life of the door.
| Part | What drift looks like | How it is measured |
|---|---|---|
| Closer | Shuts slower each month | Closing time against the handover record |
| Gap | Wider a little each year | Gauge at the same points each round |
| Seal | Hardens and pulls away | Felt and seen against the handover note |
Send the drift figures when the repair list is ready, and the security door enquiry checklist asks for the gap, the closer and the date on every line.
The record that proves the routine: what to write down and keep
The record is the proof that the routine happened. Each visit should leave a line for every door that was looked at, naming the door, what was found, what was done about it and when the work was finished, so the next person who opens the file can see the state of every door without walking the building.
Keep the record with the building file, in one place, and keep it up to date. A fault written down the day it is found is a fault that gets fixed; a fault remembered and written down weeks later is a fault that may never be fixed at all.
The record belongs to the person who runs the building, and it is the first thing a responsible person asks to see. When the file is full, it shows a building whose doors were watched; when it has gaps, it shows a building whose doors were left alone. Keep the record beside the test reports, so the proof and the routine sit in the same file. The security door maintenance checklist covers the doors that must hold both fire and forced entry.
The round finds the fault, and the repair follows the fault. A closer that stops short, a seal that has come away, a hinge that lets the leaf drag: each one is written down the day it is found, and each one is given a date, because a fault with no date is a fault that waits for the next round to find it again.
The fault found on the round gets a date before it gets a part
The first thing a fault gets is a date, not a part. The date says when the door must be fixed by, and the part follows the date, because a closer ordered without a date sits in the store while the door stands open.
The round should name the door, the part and the fault in one line, so the fitter who reads it knows which door to walk to and what to carry. A line that names the door but not the fault sends the fitter to the wrong door, and a line that names the fault but not the door sends the fitter walking the whole building.
A fault that is written down badly is a fault that is fixed badly. The note should say which door, which part and what the fitter will find when the leaf is opened, and the fire door inspection checklist gives the round its order, door by door, so no leaf is walked past and no fault goes unwritten.
Some faults close the door the same day, and some wait for the order
A closer that will not pull the leaf to the latch takes the door out of service the same day, because a fire door that stands open holds nothing at all. The door is shut, signed off and left closed until the new closer is fitted, and no one props it open in the meantime.
A seal that has hardened or a hinge that has started to sag can wait for the order, as long as the wait is written down with a date. The door still shuts, the gap is still measured, and the repair is booked for the week the part arrives.
The closer moves on every closing, so it wears before any other part, and the fire door closers guide sets the power size against the leaf, so the closer that arrives suits the door it is fitted to.
A hinge swapped for one the report never names leaves the leaf different from the one proved, so the fire door hardware guide is the place the grades are checked before the order goes out. An intumescent seal swells as the heat rises and closes the gap, so a seal that has been painted over or cut back is written down as a fault on the day it is found.
Doors that must hold fire and forced entry together take a different round, and the security door maintenance checklist names the checks that keep both proofs honest through the life of the door.
| Fault | Same day or wait | What the repair needs |
|---|---|---|
| Closer will not latch | Same day | Door out of service, new closer |
| Seal come away | Wait for the order | Seal to match the report |
| Hinge sagging | Wait for the order | Hinge to match the leaf weight |
When the repair list is ready, check it against the security door enquiry checklist, so the order names the door, the part and the date for every fault the round found.
The maintenance order: parts, dates and the doors they belong to
Put the maintenance order together as one list, with a line for every door in the building and the parts each one needs beside it. A list that names the doors but not the parts leaves the fitter to guess, and a guess is not a plan. The how to specify security doors guide sets out the columns a schedule needs.
Before the order goes out, match each quote to the schedule line by line, so every closer, seal and hinge on the list is on the quote too. A closer missed from the quote still has to be bought, and changing one on a door already in use takes longer and costs more than ordering it with the door. The security door cost factors guide works through what each step up the scale adds to the build.
Keep the test reports with the doors from the day they arrive, so the proof is never far from the leaf it belongs to. The keeping an LPS 1175 rating valid guide sets out what breaks a rating once a door is fitted, and the fire and security doors dual certification guide works through how the two proofs share one leaf, where a door must hold fire and resist attack at once.
| Part | What fails | What to check | When |
|---|---|---|---|
| Closer | Leaf left open | Power, arm, fixings | Monthly |
| Seal | Smoke through the gap | Seal intact, unpainted | Monthly |
| Hinge | Leaf drags | Fixings, sag, wear | Monthly |
| Gap | Fire past the leaf | Gap at 4 mm | Monthly |
| Glazing | Pane cracked | Glass, beads, fixings | Yearly |
A fire door only holds its proof while it shuts on its own, so the closer, the seals and the gap must all be checked on the routine.
How often should fire doors be checked?
Once a month, on a walk that looks at every fire door in turn, and once a year with a deeper check that takes the covers off the closers and measures the gaps with a gauge.
What fails first on a fire door?
The closer, because it works on every single closing. The arm bends, the spring weakens and the oil leaks, so the leaf stops short of the latch.
What gap should a fire door have?
The gap round a fire door leaf must stay at 4 mm, measured at the top and both sides. A wider gap lets fire and smoke past whatever the period on the leaf says.
Can a fire door lose its proof through poor maintenance?
Yes. A closer swapped for a lighter one, a seal painted over, a hinge changed for one the test report does not name, or a pane fitted to a solid leaf each leave the doorset different from the one tested.
Who keeps the fire door maintenance record?
The person who runs the building, with the building file. The record should name every door that was looked at, what was found, what was done about it and when the work was finished.