An arcade holds cash machines, a prize store and evening crowds behind one entrance, so each door takes the fire period its room demands, FD30 or FD60.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
An arcade is a machine hall, a cash desk and a counting room behind one entrance, and the fire rules for the building follow the rooms behind each leaf. The machine hall holds the rows of machines the evening crowd plays, the prize store holds the prizes waiting to be claimed, and the counting room holds the takings counted after close.
The minutes on an arcade leaf come from EN 1634-1, which tests the leaf against fire and counts how long it holds. FD30 holds for thirty minutes and FD60 for sixty, and the letter beside the minutes names what the leaf kept out: E for flames, EW for flames with part of the heat, and EI for flames with the heat as well.
An arcade follows the same rules as any other venue that takes a crowd through one entrance in the evening, and the leaf on each room takes its period from what sits behind it. The fire door regulations cinemas guide names the fire rules for a venue that holds a crowd in the dark, and the fire door regulations leisure centres guide names the rooms a hall keeps behind its public floor.
- FD30 / FD60Fire periods to EN 1634-1
- Machine hallWhere the crowd leaves from
- Sa / S200Smoke ratings to BS EN 1634-3
- One listEvery arcade door named
Seven rooms in an arcade: the period each leaf takes
Seven rooms make up an arcade, and the period follows what each room holds. The crowd comes in through the entrance, the cash desk takes the notes and hands out the tokens, the machine hall holds the rows of machines, the counting room keeps the takings counted after close, the prize store keeps the prizes waiting to be claimed, the back office keeps the keys and the records, and the plant room keeps the building running through the evening.
FD60 sits on the counting room, the prize store, the back office and the plant room, because the takings, the prizes, the papers and the boards behind those leaves need sixty minutes before flame reaches them. FD30 sits on the entrance, the cash desk and the machine hall route, because the crowd on that route can reach the street in far less time than thirty minutes.
Every opening gets a line of its own on the order, naming the leaf and the period beside it, so no leaf is hung on guesswork. The table names the seven rooms, the period each one takes and the grade beside the period, so the fitter checks each leaf against its own line as it is hung.
| Room | Period | Grade | What to check |
|---|---|---|---|
| Entrance | FD30 | B3 | Leaf, glass, closer |
| Cash desk | FD30 | B3 | Leaf, glass, closer |
| Machine hall | FD30 | B3 | Leaf, glass, closer |
| Counting room | FD60 | D10 | Leaf, lock, seals |
| Prize store | FD60 | D10 | Leaf, lock, seals |
| Back office | FD60 | C5 | Leaf, lock, seals |
| Plant room | FD60 | C5 | Leaf, lock, seals |
What FD30 and FD60 hold back among the machines
The minutes on a leaf are the count the doorset earned in the test, and the doorset is the leaf, the frame, the fixings and the lock proved as one. The report states the period the doorset holds, and the order writes that period beside the leaf, so the leaf that arrives is the one the room asked for. The fire door certification guide names what the report behind a period must hold.
A leaf in the arcade may need to hold fire as well as forced entry, and one doorset carries both proofs in a single report. The fire minutes come from EN 1634-1 and the forced entry grade from LPS 1175 Issue 8.2 of September 2024, in B3, C5 and D10, and the fire and security doors dual certification guide shows how the pair is proved on the same leaf.
FD60 on the counting room, prize store, back office and plant room
Behind the counting room leaf sit the takings the arcade runs on, so the leaf takes FD60 and stays shut whenever no one is counting cash. Sixty minutes is the hold the room asks for, because flame that reaches it takes the takings the arcade cannot replace.
The prize store holds the prizes waiting to be claimed, and its leaf takes FD60 for the same reason, because the prizes behind it are what the players come back for. A leaf left standing open through the evening holds nothing back, so the prize store leaf is shut each time the last person leaves the room.
The back office holds the keys, the records and the paperwork, and the plant room holds the boards and the equipment that keep the lights and the machines running, and both leaves take FD60 because the keys and the boards behind them feed the whole arcade. For the plant room leaves in full, the plant room fire doors guide is the one to use, and the plant room door requirements guide names the doors that guard the plant.
Machine hall and the way out: FD30 on the escape route
The machine hall leaf and the entrance leaf both take FD30, because the crowd stands among the machines and walks to the street through the entrance. Half an hour is more than the crowd needs to leave, and the route behind the leaves is short, with the street at the end of it.
The leaves on the way out carry a push bar proved to BS EN 1125, and the bar spans at least 60 percent of the leaf width, so a player who reaches the leaf in a crowd opens it with one push. What the bar must do when a crowd pushes against the leaf is set out in the panic hardware guide, and the leaves on the way out are covered in the emergency exit doors guide.
Staff see the crowd through a glazed panel in the cash desk leaf, so the leaf stays shut while the players are watched, and the pane is proved with the leaf round it, with the glass, the bead and the fixings named together in the report. The fire door vision panels guide names the panels a fire leaf may carry, and the steel vs timber fire doors guide sets the two leaf materials beside each other.
Smoke among the machines: Sa and S200 beside the period
People leaving the machine hall meet smoke before flame, so the leaves on the way out carry a smoke rating beside their fire period. The two ratings come from BS EN 1634-3, Sa for smoke at room temperature and S200 for smoke at 200 degrees, and how the route leaves keep the smoke back while the crowd moves past them is worked through in the smoke control doors guide.
Where a leaf must stay open through the evening, a hold-open device proved to BS EN 1155 holds it, and the device lets the leaf go on its own the moment the alarm sounds. The fire compartmentation guide names how the leaves hold the line between one part of the arcade and the next, and a chair wedged under a leaf gives it no period at all while it stands open, so the wedge is never the device that holds a fire leaf.
Closers, seals and gaps on arcade doors: what the period rests on
An FD60 leaf holds its hour only when the closer shuts it, the seals meet the frame and the gaps stay narrow, because flame passes through a leaf left ajar in seconds and through a wide gap soon after. The power sizes in BS EN 1154 start at EN 1, for a leaf 750 mm wide and 20 kg in weight, and rise to EN 7, for a leaf 1,600 mm wide and 160 kg in weight, and a fire door closer takes at least EN 3.
Heat of 200 to 250 degrees round the frame swells the seal in its groove until it closes the gap, so flame and hot gas cannot pass, and paint over the seal stops it swelling. A gauge measures the 4 mm gap round a hung leaf, and the monthly round shows whether a gap has grown past that figure. Fitting the seal is covered in the intumescent seals guide, what the closer must do in the fire door closers guide, and measuring the gaps in the fire door gaps guide.
BS EN 1935 proves grade 13 hinges for 200,000 cycles carrying 120 kg and grade 14 hinges for 200,000 cycles carrying 160 kg, so the heavier leaf takes the heavier hinge. BS 8300 and Approved Document M put the opening force below 30 N through the first 30 degrees and below 22.5 N after them, so a player in the crowd can push the leaf open without help. The fire door signage guide names what each sign on a fire door must say.
Getting the evening crowd out: the way from the machines to the street
The alarm may sound while players who have never used the building sit at the machines, so the route to the street is signed at every turn. The route stays clear, and the entrance leaf opens to one push from whoever reaches it first, whether the supply to the building is on or off.
Martyns Law puts a venue in a tier by how many people it holds, one tier for 200 to 799 people and a higher tier at 800 and above, with Royal Assent in April 2025 and the go-live expected in spring 2027. What each tier asks for is set out in the Martyns Law guide for premises, and an arcade holding 200 or more people falls in a tier that guide covers.
The arcade fire door order: every leaf, its period and its proof
Every opening in the arcade gets a line on the order, with the leaf, the period, the lock and the closer written beside it. One leaf named for the whole arcade leaves the fitter to guess, and a leaf in the wrong room holds flame for the wrong length of time.
Each leaf on the order is checked before it is signed, because a closer ordered after the doorset arrives holds the job up, and a leaf with no line beside it is a leaf no one can check when it arrives. The how to specify security doors guide names what the order must hold for every door.
The arcade manager takes the door list round the building once a month and tries the leaves in turn. A leaf that drags, a closer that leaves the leaf standing open or a seal painted over in a refit is written against its own door on the day it is found. The fire door inspection checklist names what to look for on each leaf, and the fire door maintenance guide names the work that keeps the leaves holding.
The period on an arcade leaf follows the room behind it, so FD60 and FD30 must sit on the same list as the grade and the lock for each leaf.
What period should an arcade counting room door carry?
FD60 to EN 1634-1, because the counting room holds the takings, and an hour is the hold that room demands.
What period should an arcade entrance door carry?
FD30 to EN 1634-1, because the entrance is the way out for the crowd and the public route needs half an hour.
Can one leaf hold fire and forced entry?
Yes, where the same doorset passed both tests, so the period and the grade are named in one report beside the same leaf.
Do arcade fire doors need a smoke rating?
Yes, the leaves on the route carry Sa or S200 to BS EN 1634-3 beside their period, because the crowd on the way out meets smoke before it meets flame.
What happens when a fire door will not shut?
A leaf that will not shut is written up against its own door the day the fault is found, and the arcade does not wait for the next look round before the leaf is put right.