Perimeter and HVM · PAS 68 and IWA 14-1
Rising Bollards UK: Automatic and Crash Rated
Rising bollards for entrances that open all day: crash ratings, duty cycle, power, fail states, drainage and the service routine that keeps them working.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A rising bollard is a steel post that sinks into a pit in the road to let a vehicle through and rises again to close the entrance. The post, the pit, the drive and the controls work as one machine: the drive lifts the post, the controls decide when it moves, and the pit keeps the mechanism dry and clear of grit. Rising bollards suit entrances that must open many times a day for authorised vehicles and stay closed between them, such as staff car parks, service yards and secure compounds. A fixed bollard cannot open at all and a gate needs room to swing or slide, so the rising bollard fits where space is tight and traffic is frequent.
- Rises in a few secondshydraulic drives commonly rise in around 2 to 4 seconds, electromechanical drives in around 4 to 7 seconds
- Fail safe or fail securethe position on power loss is chosen when the bollard is ordered, not discovered later
- Crash rated as one unitsome rising bollards are tested to PAS 68, IWA 14-1 or ISO 22343-1 as a single bollard in its pit
- A machine in a pitpower, drainage and a service routine decide whether it keeps working
How a rising bollard works
The unit has four parts. The post is a steel cylinder that stands above the road when raised and sits close to flush with the surface when lowered. Raised heights vary by model, commonly from 500 mm to 1,200 mm. The housing is a pit set into the ground that holds the post when it is down. The drive moves the post up and down. The control cabinet holds the controls and the power supply, and it can sit beside the line or in a nearby cabinet, with one panel able to run several bollards in a line.
Safety devices stop the bollard rising under a vehicle. A ground loop or a safety edge detects a vehicle over the unit and holds it down, and a light crown and a sounder warn people nearby while the post is moving. The bollard must never rise into a vehicle that is still over it, so the safety devices are tested at commissioning and checked again at each service. The security bollards page sets out the range, including fixed, removable and shallow mount types that sit beside rising units in a line.
In a line, a rising bollard guards the opening while fixed bollards fill the parts that never open. The same spacing rule applies along the whole line: ProtectUK hostile vehicle mitigation guidance gives a maximum clear gap of 1,200 mm between barriers and a minimum height of 500 mm. The security barriers in Birmingham page shows how rising and fixed units share one frontage, with each part of the line chosen by how often it must open.
Hydraulic or electromechanical: choosing the drive
Two drive types cover most rising bollards. A hydraulic drive uses a pump to move fluid and lift the post. An electromechanical drive uses a motor to drive gears or a screw. The choice turns on how often the bollard moves and how heavy the post is, not on appearance, because both types look the same from the road.
| Drive | How it moves | Rise time | Duty | Servicing |
|---|---|---|---|---|
| Hydraulic | Pump moves fluid to lift the post | Around 2 to 4 seconds | Continuous, high-frequency use | Fluid, seals and pump checks |
| Electromechanical | Motor drives gears or a screw | Around 4 to 7 seconds | Moderate use; check rated cycles per day | Motor and gear checks, no fluid |
Hydraulic drives suit the busiest entrances and the heaviest crash-rated posts, because the pump handles continuous use and the post can be lifted quickly. Electromechanical drives suit entrances with moderate traffic, where a simpler unit with no fluid is easier to look after. Some designs give each bollard its own pump, so a fault in one unit leaves the rest of the line working. Ask for the figures on the datasheet before choosing: rise time, rated cycles per day and the operating temperature range. The guide to choosing HVM bollards compares the four bollard types and the access each one suits.
Crash ratings for a bollard that moves
A rising bollard can be crash rated, but only as tested: raised, in its pit, as a single unit or as a row, exactly as the test record states. A rating for a fixed bollard does not cover a rising unit, and a rating earned by one model does not cover another. The pit, the housing and the fixings are part of the tested system, so a rated post in an untested pit carries no rating. The vehicle impact ratings page sets out what a rating must state: the vehicle, the speed, the angle and the penetration.
The rating is read the same way as for a fixed barrier, and the PAS 68 bollards guide decodes the full rating string. The three standards are PAS 68, IWA 14-1 and ISO 22343-1:2023, and ISO 22343-1:2023 is the current international standard, superseding PAS 68:2013 and cancelling and replacing IWA 14-1:2013. The HVM standards guide compares the three documents, and the ISO 22343 guide explains the rating field by field.
A rising bollard without a crash rating is access control only. It controls who may pass, but it does not stop a vehicle, and it should be sold as access control, not as protection against a vehicle. Where the threat assessment names a vehicle, the rising unit must carry a crash rating that matches the vehicle and the approach speed. The rating also covers the raised position only: a lowered bollard protects nothing, however strong the post is.
Spacing is part of the rating too. The line the rising bollards sit in must keep the tested clear gap, and the bollard regulations guide sets out the spacing, height and depth rules and where each number comes from. PAS 69 is the companion guidance on selecting, installing and using hostile vehicle mitigation, and it sits beside the test standards rather than replacing them.
Duty cycle: matching the bollard to the traffic
Duty cycle is how much of the time the drive can run. A bollard at a staff car park entrance may rise and fall hundreds of times a day, while a bollard at a service yard may move only a few times. The drive must be rated for the daily count, because a drive worked past its duty slows down, overheats and stops until it cools.
Rated cycles per day vary widely between models, from a few hundred to a few thousand, so compare the datasheet figures rather than the drive type alone. A model rated for a few hundred movements a day will not survive a car park entrance that cycles a thousand times.
Count the real movements before ordering: staff shifts, deliveries, waste collection and emergency access drills, then add a margin for the busiest day. A drive chosen with room to spare costs less over its life than a drive replaced early. Where vehicles pass all day without pause, a road blocker or a rated gate may suit better than a bollard that must rise and fall for each vehicle, and the anti-ram gates and barriers guide covers the rated options for those entrances.
Power, controls and who can lower it
Power runs to the control cabinet, commonly on a 230 V mains supply. The cabinet position is agreed before digging starts, because the cable route, the ducting and the cabinet must be in place before the pit is poured.
Controls decide who can lower the bollard. Common options are a key switch, a remote control, a keypad, an intercom, an access control system or automatic number plate recognition, and a barrier can be triggered by any of these so a verified vehicle is let through without a member of staff needing to buzz it in. One control panel can run several bollards in a line, so the whole entrance opens and closes as one.
Only authorised users should be able to lower the unit, and the list of who holds a key, a remote or a code is agreed with the site team before handover. How the emergency services lower the bollard is agreed in advance too, and written into the site plan, so access does not depend on finding one person on the day. The hostile vehicle mitigation page sets out how barrier lines, spacing and layout work together across a site.
What happens when the power fails
Two versions are offered, and the choice is made when the bollard is ordered. The standard version is fail safe: it drops on a power cut, so the entrance stays open. The security version is fail secure: it stays raised on a power cut, so the line stays closed. Neither is right for every site, and the wrong choice is discovered at the worst possible time.
Fail safe suits an entrance that must never trap vehicles inside, including an emergency route, because a power cut must not block the way out. Fail secure suits a site where the line must stay closed, such as a secure compound, because a power cut must not open the perimeter. The decision follows the risk at the entrance, not the price of the unit.
A fail secure unit can be lowered by hand with a release key when the power is off. The key must be held where staff can reach it, and staff must know how to use it before they need it. Test the release at handover with the power off, and record the result, so the fail state is proven rather than assumed.
A bollard that stays down is an open entrance. Whatever the fail state, the routine must bring the unit back up, and a unit left down for convenience leaves the line open.
The pit: drainage, cold weather and the ground below
The pit is a hole in the ground that holds a machine, so water is the enemy. The pit needs a drainage route, usually a gravel bed with a pipe to the drainage system, and a pump where gravity cannot clear the water. Standing water can reach the motor and the electrical connections, so the drainage must be proven on site before the unit goes in, not assumed from the drawings. The installation page covers the ground conditions a rated barrier needs.
Before digging, check what lies below: power, gas, water, drainage and telecoms may run under any part of the line, and a service survey should map every route before the pit positions are fixed. The water table matters too, because a pit in wet ground fills faster than one in free-draining ground. A soak test on the excavated pit proves the drainage works before the unit is set.
Cold weather needs a heater, offered as an accessory, which switches on when the temperature falls, commonly below 5 C. The heater keeps the hydraulic fluid and the mechanism working through a cold spell, and the operating temperature range for the unit is stated on the datasheet. Ask for the range in writing, and check it against the coldest nights the site sees.
Pit depth follows the lowered post, so a taller bollard needs a deeper pit. Where digging is limited by services or a structure below, shallow-mount rising options exist, but the rating must name the shallow arrangement: a deep-foundation rating does not cover a shallow pit. The top of the housing sits slightly above the finished surface to limit rainwater running into the pit, and grit and debris must be kept clear of the opening so the post seats fully when it lowers.
Keeping a rising bollard working
A rising bollard is a machine, so it needs a service routine from day one. The drive, the seals, the drainage, the controls and the warning lights and sounder all need scheduled checks, and the intervals sit in the maintenance schedule supplied with the unit. Follow the schedule rather than waiting for a fault, because a bollard that fails is either an open entrance or a blocked one.
Seals wear and let water into the pit. Grit in the pit stops the post seating fully when it lowers. Hydraulic fluid level and condition need checking, and electromechanical gears wear with use. The control panel and the safety devices are tested at each visit, so a ground loop or a safety edge that has stopped working is found before a vehicle is. The maintenance page covers upkeep across the range.
After a strike, the unit and its pit are inspected before the line goes back into service. A struck bollard is normally replaced, and the pit is checked for damage that could weaken the next impact. A bollard put back into use without that check carries no proven rating.
Keep the records with the building documents: the test certificate naming the standard and the rating, the pit and foundation drawing, the service log and the fail-state test result from handover. The next person to work on the entrance needs to know what the bollard was built to stop, how it is controlled and when it was last serviced. The security gates page and the sliding vehicle gates page cover entrances where a gate suits the opening better than a bollard line.
How fast does a rising bollard rise?
A few seconds. Hydraulic drives commonly rise in around 2 to 4 seconds and electromechanical drives in around 4 to 7 seconds, depending on the drive and the size of the unit. Some crash-rated models offer an emergency fast operation option that raises the bollard in around 2 seconds. Ask for the figure on the datasheet, because the rise time is a property of the model, not of rising bollards in general.
What happens to a rising bollard in a power cut?
It depends on the version ordered. A fail safe unit drops on a power cut, so the entrance stays open. A fail secure unit stays raised, so the line stays closed, and it can be lowered by hand with a release key. Decide which version the site needs when ordering, and test the release at handover with the power off.
Can a rising bollard stop a vehicle?
Only if it is crash rated as tested. A rising bollard tested to PAS 68, IWA 14-1 or ISO 22343-1 as a single unit in its pit can stop the vehicle named in its rating. A rising bollard without a crash rating is access control only: it controls who may pass, but it does not stop a vehicle.
How often does a rising bollard need servicing?
At the intervals in the maintenance schedule supplied with the unit. The drive, seals, drainage, controls and safety devices are checked at each visit, and the intervals vary with how often the bollard moves, so follow the schedule rather than a fixed calendar. A bollard that moves hundreds of times a day needs more frequent checks than one that moves a few times.
Do rising bollards work in freezing weather?
Yes, where the unit is specified for it. A heater is available as an accessory and switches on in cold weather, commonly below 5 C, and the pit must drain so water does not collect and freeze around the mechanism. Check the operating temperature range on the datasheet and ask for it in writing before ordering.
Get a free quote
Related
More in perimeter security and hvm
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.