ArxBridge
Transport hub security requirements
Transport hub security requirements, from forecourt vehicle mitigation to LPS 1175 staff doors: Martyn's Law tiers, PAS 68 ratings and the evidence to ask for.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
Transport hub security requirements start at the kerb and end at the plant room door. Vehicles are stopped at the forecourt by barriers tested to PAS 68 or ISO 22343-1, crowds pass through controlled entrances, concourse glazing is tested to ISO 16933 with a stated hazard rating, and staff-only doors are rated to LPS 1175. The requirements come from the risk assessment for the hub and, for larger premises, from the duties in the Terrorism (Protection of Premises) Act 2025, which names no product and no rating.
- 200 to 799 peoplestandard tier under Martyn’s Law; 800 or more is the enhanced tier
- PAS 68 and ISO 22343-1vehicle impact ratings for forecourt barriers and bollards
- 1,200 mm maximum gapbetween barriers in ProtectUK HVM guidance, 500 mm minimum height
- LPS 1175 B3 to D10forced entry ratings for staff doors, plant rooms and control rooms
Where the requirements come from
A hub operator starts with the risk assessment, not with a catalogue. The assessment records who uses the building, how many people may be present at the busiest time, which vehicles reach the forecourt, and which doors open from public areas into staff-only space. Those answers decide the measures. A requirement written before the assessment is a guess.
Martyn’s Law, the Terrorism (Protection of Premises) Act 2025, adds duties on top of the assessment. It received Royal Assent in April 2025. The standard tier covers premises where 200 to 799 people may be present, and the enhanced tier covers premises where 800 or more may be present, and qualifying events. Enhanced tier premises must consider physical measures. The Act names no product and no rating, so the choice of barriers, doors and glazing still follows from the risk assessment. The regulator is the Security Industry Authority, go-live is expected in spring 2027, and an implementation period of at least 24 months applies before enforcement, with an advisory-first approach. The Martyn’s Law standards page sets out the tiers, and the Martyn’s Law guide for premises explains where physical measures fit.
The forecourt and drop-off: vehicle mitigation first
The drop-off is where vehicles get closest to crowds, so it is where vehicle mitigation starts. Barriers and bollards for a forecourt are rated to PAS 68, IWA 14-1 or ISO 22343-1, and a rating states the vehicle type and mass, the impact speed, the impact angle and the penetration distance. Test vehicles run from a 1,500 kg car to a 30,000 kg truck at 48, 64 or 80 km/h. The HVM standards guide shows how to read a rating code, and the vehicle impact ratings page sets out the three standards side by side.
Spacing matters as much as the rating. ProtectUK HVM guidance gives a maximum clear gap of 1,200 mm between barriers and a minimum height of 500 mm. Gaps wider than that let a vehicle through, and units lower than that can be driven over. The layout must also keep people moving and keep a passable route for emergency vehicles. Shallow-mount units suit forecourts where services run below the surface. See how to choose HVM bollards, HVM planters and street furniture and the ProtectUK HVM guidance.
Entrance control: moving crowds without creating a queue target
Entrances have two jobs at once: they must move peak flows quickly, and they must keep unauthorised people out of staff areas. A slow entrance fails the first job and creates its own problem, because a long queue outside the doors is itself a crowd standing in the open. Size the control on the peak flow, not the average, and give staff controlled lanes beside wide public openings.
Turnstiles, pedestrian speed gates and security portals each admit one person at a time, and the choice between them turns on flow rate, accessibility and whether the lane is staffed. Turnstiles suit staff entrances with steady flows. Speed gates suit concourse entrances. Portals suit control rooms, where a single person must be checked before entry. The turnstile, speed gate and portal guide compares the three, and the pages for turnstiles, pedestrian speed gates and security portals set out the options. A single credential should admit a single person, so the lane must make a second person visible.
The concourse: glazing, blast and the space behind the glass
Concourses carry the blast risk of a hub. Large glazed facades and roofs turn blast pressure into flying fragments across crowded space, so concourse glazing needs a rating, not just a thickness. ISO 16933 rates blast glazing for vehicle bombs and satchel charges. EXV classes use 100 kg TNT equivalent at stand-off distances from EXV45 down to EXV10, where the number is the distance in metres and EXV10 is the most severe. SB classes cover hand-carried charges. Results carry a hazard rating from A, no break, to F, high hazard. The blast ratings page covers the full scale, and ISO 16933 EXV vs SB explains the two charge types.
The rating belongs to the tested assembly: glass, interlayer, frame and fixings together. A laminated assembly can read as standard curtain walling, which is why the tested assembly matters more than the appearance. Glazing specified as a pane alone, without the frame it was tested in, is unproven, and a frame changed after testing voids the result. The hazard rating also decides what the space behind accepts: a rating of A leaves the room usable, while a rating at the F end means fragments reach the room. See blast resistant glass and the glazed vs solid blast door guide.
Staff doors, plant rooms and service yards
Back-of-house areas hold ticket offices, cash handling, control rooms and plant: less footfall, but higher value targets. Service corridors give quiet routes through the building, so the doors on those routes need ratings that match the value behind them. LPS 1175 rates forced entry resistance from A1 to H20, combining a tool category with minutes of attack time. B3 holds for three minutes against hand tools and suits most staff entrances. C5 extends that to five minutes against crowbars and drills and suits cash handling and control rooms. D10 holds for ten minutes against sledgehammers and disc cutters and suits the highest value rooms. The LPS 1175 standards page sets out the full scale, and 10 steps to specify an LPS 1175 door covers the specification.
The rating applies to the doorset, not the leaf. Frame, fixings and hardware sit inside the tested design, and a change to any of them can void the rating, so the order should name the doorset as tested and the handover should confirm it. Keeping an LPS 1175 rating valid covers the changes that cause problems. Shutters for service yards are rated to LPS 2081, SRA for one minute and SRB for three minutes. Fire and security meet in the same doorset: EN 1634-1 rates fire doors E, EW and EI from 30 to 120 minutes, and dual certification explains how the two ratings sit together. See also plant room door requirements.
Layering the measures: a complete requirement set
No single product secures a hub. The requirement set works as layers, and each layer answers one threat at one zone. The table below sets out a complete set, with the evidence to ask for at each layer. A layer with no evidence behind it is a claim.
| Zone | Threat | Measure | Evidence to ask for |
|---|---|---|---|
| Forecourt and drop-off | Vehicle attack on crowds | PAS 68 or ISO 22343-1 barriers | Rating code and test certificate |
| Station entrance | Uncontrolled entry and tailgating | Speed gates or portals | Throughput and access control specification |
| Concourse glazing | Blast fragments | ISO 16933 tested assembly | Hazard rating A to F for the assembly |
| Staff entrances | Forced entry | LPS 1175 B3 doorsets | Doorset test certificate |
| Plant rooms and service yards | Forced entry and vehicle intrusion | LPS 1175 C5 or D10 doors, LPS 2081 shutters | Doorset and shutter test evidence |
Evidence to ask for before you order
Every rated product should arrive with its evidence, and the time to ask for it is before the order, not after the installation. Ask for the test certificate naming the product and the standard, the rating code written in full, and confirmation that the tested assembly matches what will be supplied. For vehicle mitigation, ask for the PAS 68 or ISO 22343-1 classification in full, including the foundation the test used, because a barrier tested on one foundation and installed on another is unproven.
Installation records are part of the evidence: the record should show the products were fitted as tested, with the fixings and the substrate the test assumed. The installation page covers what a fitted installation includes, and installers should be asked to record the fixings used, the substrate found and any change made on site. A rating quoted without test evidence behind it should be treated as unproven.
Martyn’s Law names no product and no rating. A requirement that starts from a catalogue instead of a risk assessment is the wrong way round: define the threat, then choose the tested product that answers it.
The forecourt first: the vehicle line before the front door
A transport hub moves crowds through one building, so the security line starts outside, at the forecourt, and works inward to the doors. The vehicle line comes first, then the entrance, then the concourse, then the rooms behind it.
ISO 22343-1 proves a barrier by driving a vehicle at it, and the rating it earns names the vehicle, the speed, the angle and how far the vehicle gets past the line. The test covers vehicles from a 1,500 kg car to a 30,000 kg truck, at 48, 64 or 80 km/h, so the schedule names the exact rating the forecourt line must carry. The ratings in full are in our ISO 22343 vehicle security barriers guide.
The gap and the height sit beside the rating on the schedule. ProtectUK guidance caps the clear gap beside a barrier at 1,200 mm and sets the minimum height at 500 mm, so a gap wider than the cap lets a vehicle through beside the barrier and a barrier lower than the minimum lets a vehicle climb it. Bollards fill the gaps between the gate post and the wall, the gate and the fence, and along the pavement where a vehicle could mount the kerb. Our choosing HVM bollards guide works through the options, and the security bollards page covers the bollards themselves.
Anti-ram gates and road blockers hold the line where a vehicle must be stopped, not just slowed, and the rating for that line comes from the vehicle test, not from the gate leaf alone. Our anti-ram gates and barriers guide works through the options, and our road blockers guide covers the blockers that rise from the road.
Blast and vehicle ratings prove different things, so they stay on separate lines. A barrier that stopped a vehicle has proved nothing about a blast, and a door that held a blast has proved nothing about a vehicle. Each rating sits on the product it was tested on, and the schedule keeps the two apart.
Doors behind the crowd: staff, plant and the rooms the public never sees
Entrance control moves a crowd without creating a queue target. Turnstiles and speed gates sit on the way in, not on the way out, and they must release when the alarm sounds and fail safe when the power goes. The security turnstiles guide covers readers, fobs and biometrics in the lane.
Concourse glazing takes a blast rating where the threat asks for it. Under ISO 16933 the EXV class names the charge weight a door must resist at a set distance, and the SB class names the hazard the glazing leaves behind, from A to F. Windows, doors and shutters can also be proved under EN 13123 and EN 13124, whose ratings run EPR and EXR, so the schedule names the standard beside the class it belongs to. Our blast-resistant windows guide works through the same discipline for windows.
The rooms the public never sees carry their own ratings. A plant room door takes FD60, with a closer that can pull a heavy leaf shut against the draught the plant draws through the room, and a staff door takes a rating to LPS 1175, B3, C5 or D10 by the room it guards. A door that must hold fire and resist attack at once needs a proof for each job on the same doorset, and the plant room door requirements guide covers those doors in full.
| Line | Rating | What to check |
|---|---|---|
| Forecourt and drop-off | ISO 22343-1 | Vehicle mass, speed, gap 1,200 mm, height 500 mm |
| Entrance control | Turnstiles and speed gates | Release on alarm, fail safe |
| Concourse glazing | ISO 16933 EXV + SB | Charge weight, stand-off, hazard A to F |
| Staff and plant doors | FD60, B3 to D10 | Closer, lock, seals, self-closing |
Ask for the test report on each line before the order is placed, with the rating, the position and the assembly named on the same line, so the next reader can see what was proved and what holds it.
Common mistakes when specifying hub security
The most common mistake is buying before the risk assessment is done. An order placed on a catalogue description, without a capacity figure, without mapped vehicle routes and without a list of staff-only doors, will fit some zones and miss others, and the missed zones are usually the quiet ones: the service yard, the plant room, the corridor behind the ticket office.
The second mistake is specifying a rating and forgetting what carries it. A vehicle barrier needs the foundation its test used. A doorset needs the frame and fixings its test used. Glazing needs the frame its test used. The third mistake is reading Martyn’s Law as a product list. The Act sets duties by tier and asks enhanced tier premises to consider physical measures; it does not name a barrier, a door or a pane of glass.
Does every station fall in the enhanced tier?
No. The tier follows how many people may be present: 200 to 799 people is the standard tier, and 800 or more is the enhanced tier. A small station or bus station may sit in the standard tier, while a major interchange will usually sit in the enhanced tier. Check the capacity figure and the SIA guidance.
What vehicle rating does a drop-off need?
The risk assessment decides. A rating states the vehicle type and mass, the impact speed, the impact angle and the penetration distance, so the rating to specify is the one that matches the vehicles and speeds in the assessment. Ask for the test certificate before ordering.
Can a concourse keep its glass frontage?
Yes. Laminated assemblies tested to ISO 16933 can read as standard curtain walling, because the rating sits in the interlayer, the frame and the fixings. The tested assembly matters more than the appearance, so ask for the hazard rating for the assembly as installed.
Which LPS 1175 class suits a staff entrance?
B3 suits most staff entrances, C5 suits rooms holding cash or control equipment, and D10 suits the highest value rooms. The assessment decides: the class follows the value behind the door and the time an attacker would have before being challenged.
What should the handover pack contain?
Test certificates for every rated product, the rating codes written in full, installation records showing the products were fitted as tested, and the instructions for keeping each rating valid. If a certificate is missing, the rating is unproven, however the product is described.
Upgrading security at a transport hub? Send your site plan and we will specify HVM, blast glazing and rated doors for each zone.
Related
More in guides for specifiers
Products
One supplier for the whole building envelope
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.