ArxBridge
Turnstile vs speed gate vs security portal: choosing entrance control
Turnstile vs speed gate vs security portal: a UK buyer's guide to choosing entrance control, comparing throughput, security, footprint and cost drivers.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
Choose a speed gate for a busy UK office lobby where flow and appearance matter most. Choose a turnstile where the lane faces weather, crowds or rough treatment. Choose a security portal where only one verified person may pass, such as a data hall or cash office. The rest is detail: throughput, footprint, accessibility and cost.
- Speed gateMotorised panels; fastest lane for busy lobbies
- TurnstileRotating arms; simple and tough, inside or out
- Security portalInterlocking doors; one verified person at a time
- TailgatingThe misuse all three are designed to stop
What each stops: tailgating, piggybacking and forced entry
Tailgating means slipping through on someone else’s credential, close behind them. Piggybacking is the deliberate version, where an authorised person holds the way open. Forced entry is the physical attack: climbing over, crawling under or forcing the barrier. Each product answers a different mix of the three.
A tripod turnstile gives a mechanical one-at-a-time action. The rotating arms stop casual tailgating because the next person cannot pass until the arms reset. At waist height the arms can still be jumped or crawled under, so the deterrent works best where staff or cameras watch the lane.
A speed gate answers tailgating with sensors rather than arms. Detection zones watch the lane, and the controller can spot a second person, reverse entry or a forced panel, then sound an alarm and hold the barrier. The glass or acrylic panels are a deterrent, not a wall. They suit a supervised lobby where misuse is opportunistic, not determined.
A full-height turnstile or a full height glass turnstile answers forced entry at the lane. The rotor or glass leaves run floor to ceiling, so climbing over and crawling under are off the table. It is the right call for unsupervised points: car park stairs, transport interchanges and perimeter gates where nobody watches.
A security portal answers piggybacking, the case the others cannot fully close. Two interlocking doors and single person detection mean the second door only opens when the sensors confirm one occupant. Where the threat assessment names forced entry as well, ask whether the portal has been attack tested to LPS 1175. B3 means 3 minutes against hand tools such as screwdrivers, pliers and hand saws. C5 means 5 minutes against crowbars, drills and chisels. D10 means 10 minutes against sledgehammers, disc cutters and jigsaws.
Honest limit. None of the three replaces a rated security door where the specification demands a tested delay. Lanes control honest people and deter the casual intruder. A determined attacker with tools is a job for security doors tested to a named rating.
Throughput and footprint
Throughput is set by the whole transaction, not the barrier. Credential presentation, reader speed, failed reads, bags, mobility aids and direction changes all slow a lane. Size the lane count from your own arrival pattern, not from a brochure figure.
Speed gates are the fastest of the three in steady office flow. The panels start opening as the credential is read, so a familiar user barely breaks stride. Tripod turnstiles are slower and more deliberate: one push, one person, one reset. That rhythm suits shift changes and crowds because it never loses count, even if it never sprints.
Portals are the slowest by design. One person enters, the first door closes, the sensors check, the second door opens. The cycle buys certainty at the cost of flow, which is why portals guard the data hall while pedestrian speed gates guard the lobby.
Footprint follows the same order. A tripod lane is compact. A speed gate needs lane length for the panels and their sensor zones. A portal needs the deepest footprint of all: two door sets plus the interlock zone between them. Leave queue space on both sides at peak, and check the floor can take the fixings, especially outdoors or on retrofit installs.
The morning peak: the hour the lane count must pass
The lane count should follow the people the entrance must pass at its busiest hour, not the people it sees through the day. A lane that passes a steady trickle all day and queues at the morning peak has too few lanes, because the whole building arrives at once and the entrance must pass them all before the working day starts.
The peak belongs on the order beside the lane count, with the busiest hour named and the number of people who must pass in that hour. A count taken from the average day leaves the entrance short at the peak, and a count taken from the peak leaves the lobby with lanes that stand empty for the rest of the day.
The lane type sets how many people each lane can pass, because a tripod lane passes fewer people than a glass speed gate, and a portal that holds each person until the door behind them closes passes fewer still. The count should follow the lane type, so a portal line needs more lanes than a tripod line for the same crowd.
The staff who arrive early and the visitors who arrive late ask different things of the lanes, because the staff pass through on a card they hold every day while the visitors wait at reception for a pass. The peak should count both, so the lanes that pass the staff in the morning also pass the visitors who arrive through the day.
The queue before the lanes: the space the lobby must hold
The queue the entrance must hold belongs on the plan beside the lanes, because a crowd that cannot fit before the lanes spills into the street or back through the doors it came in by. The lobby should hold the queue for the busiest hour, with room for the people who wait and the people who pass them by.
The reception desk should sit where the queue can see it, because the visitors who need a pass must reach the desk without crossing the queue. A desk hidden behind the lanes leaves the visitors to push through the crowd, and a desk beside the lanes lets the staff hand out passes while the queue moves.
The way out needs the same space as the way in, because the crowd that leaves at the end of the day is the same crowd that arrived in the morning. The lobby should hold the queue for the way out as well, so the lanes that let people in also let them out without a crush at the doors.
| Part | What it names | What to check | When |
|---|---|---|---|
| Peak hour | Busiest hour named | People who must pass | Before the order |
| Lane type | Tripod, speed gate or portal | Passes per lane | Before the order |
| Staff | Cards held every day | Pass at the peak | Before the order |
| Visitors | Pass from reception | Desk beside the lanes | Before the order |
| Queue | Space before the lanes | Holds the busiest hour | Before the order |
The lanes in full are covered in the security turnstiles guide, and the lane count and the building work beside it are worked through in the turnstile cost factors guide. Readers, releases and wiring beside a lane are covered in the door entry systems guide, and the rules for the shared parts of a public building are set out in the fire door regulations commercial buildings guide.
Look and the reception area
The entrance sets the tone of the building, and the three products read very differently. Speed gates are the lobby product: slim cabinets, glass panels and a quiet action that suits corporate receptions, banks and headquarters. They present security as a background service, not a checkpoint.
Full-height glass turnstiles keep the full-height deterrent but let light and sightlines through. Staff at the desk can see the lane, and visitors can see the reception beyond. The trade-off is housekeeping: glass shows fingerprints and needs regular cleaning to keep its look.
Tripod turnstiles read as functional: fine back of house and on perimeters, but heavy in a client-facing lobby. Security portals read as high security, which is exactly right for a data centre or a cash office and exactly wrong where you want visitors to relax.
Where the entrance must also impress and control draughts, a revolving security door is the related option. It manages airflow and presents a grander face, with access control built into the rotation. Our types of security doors guide places all of these in the wider family.
Waist height versus full height
Waist-height lanes control honest users. Tripod arms, optical beams and speed gate panels all stop the casual walk-through, but they can be climbed or crawled past by someone who decides to. That is acceptable where the lane is supervised or where the risk is nuisance rather than loss.
Full-height lanes remove the climb-over and crawl-under routes. A full-height rotor turnstile suits outdoor and unsupervised points: perimeter gates, plant compounds and transport sites where weather and rough treatment rule out delicate equipment. Full-height glass versions do the same job indoors where appearance still matters, for example at a transport hub entrance that runs unstaffed at night.
Full height brings its own demands. The units are taller, heavier and more imposing, they need a firm fixing and they must release safely on fire alarm. If the threat does not justify that, waist height plus supervision is the cheaper and friendlier answer.
Security portals and single person detection
A portal is an interlocking cabin: two door leaves with a small chamber between them. The first door opens on a valid credential and the person steps in. The first door closes. Only then do the sensors check the chamber, and only when they confirm a single occupant does the second door open. One credential, one person, every time.
Single person detection usually combines weight measurement with volumetric or infrared sensing. The logic must tell one person with a bag from two people close together, without trapping a nervous visitor. That is why portals need commissioning on site, with sensitivity set for the real users.
Specify a portal where a second person must never enter on one credential: data halls, server rooms, cash offices and research labs. Our data centre physical security guide shows where the portal sits in the layered plan. Do not specify one where flow matters more than certainty. A portal on a main staff entrance will queue the building.
Accessibility lanes and fire egress
The Equality Act 2010 requires service providers to make reasonable adjustments for disabled people, and entrance control is part of that duty. Standard lanes are too narrow for a wheelchair user, so the design needs at least one wider lane: a broad speed gate lane, a powered accessible gate or a supervised manual gate beside the bank. Plan it from the start, not as an afterthought.
Fire egress is the other non-negotiable. On fire alarm or power failure the lanes must release to free exit, and the behaviour must be agreed with the building’s fire risk assessment before anything is ordered. Full-height turnstiles need a fail-safe release or an adjacent escape gate. A portal must never be the only way out of the space it guards unless the escape strategy specifically allows it.
The Terrorism (Protection of Premises) Act 2025 adds context for larger sites: 200 to 799 people is the standard tier, 800 or more the enhanced tier, with the Security Industry Authority as regulator. Where those duties apply, entrance control and clear egress belong in the same plan.
Turnstile, speed gate or portal: side by side
| Feature | Turnstile | Speed gate | Security portal |
|---|---|---|---|
| Main threat stopped | Casual tailgating; full height stops climb-over | Sensor-detected tailgating and reverse entry | Piggybacking; one person per credential |
| Throughput | Moderate, one at a time | Fastest in steady office flow | Slowest, one cycle per person |
| Footprint | Compact | Needs lane length for panels | Deepest: two doors plus chamber |
| Look | Functional to industrial | Sleek, suited to receptions | Enclosed, reads as high security |
| Outdoor use | Yes, full height suits perimeters | Prefers indoor, sheltered lobbies | Possible with weather-rated build |
| Accessibility | Needs an adjacent wide lane | Wide lanes available in the bank | Needs an adjacent wide lane |
| Fire egress | Fail-safe release or escape gate | Panels open on alarm | Interlock must release to exit |
| Best for | Perimeters, stadia, unsupervised points | Office lobbies and receptions | Data halls, cash offices, labs |
Access control integration and what drives the cost
The lane is only as good as the system behind it. Card readers, fobs, mobile credentials, QR codes and biometrics all present to the lane controller, which must talk to the existing access control platform. Confirm the interface early, plan power and data to each lane, and make sure visitor management and the intercom reach the same controller so guests are not stranded.
Cost drivers, without prices because every site differs: lane count and width; barrier material, where glass panels cost more than steel arms; detection and anti-tailgating sophistication; access control integration; floor works and outdoor foundations; finishes and branding; and the ongoing maintenance that keeps sensors aligned. A lane that is never serviced gets propped open. See the full guides hub for related comparisons.
Can someone tailgate through a speed gate?
The sensors are designed to spot it. A second person in the lane, reverse entry or a forced panel raises an alarm and the barrier holds. That works well against opportunists in a supervised lobby. It is not a wall, so where the threat is determined rather than casual, a full-height turnstile or a portal is the stronger answer.
Do turnstiles work outdoors?
Full-height turnstiles are the outdoor choice. They tolerate weather and rough treatment and need no supervision to stay effective. Tripod models can work under a canopy. Speed gates prefer a sheltered indoor lobby, where their sensors and finishes stay at their best.
What happens to the lanes in a fire or a power cut?
They must fail safe to free exit, opening or releasing so people can leave. The exact behaviour is set with the building’s fire risk assessment before the order, and full-height units need a fail-safe release or an adjacent escape gate.
Can a wheelchair user get through?
Not through a standard lane, which is too narrow. The Equality Act 2010 duty of reasonable adjustment means the design should include at least one wider lane, such as a broad speed gate lane or a supervised accessible gate beside the bank.
Which should a data centre choose?
Both, in different places. Speed gates suit the office lobby where staff flow matters, and a security portal guards the data hall. The data centre physical security guide linked above maps the layers.
When is a rated portal worth asking for?
When the threat assessment names forced entry, not just tailgating. Ask for the attack test evidence. To LPS 1175, B3 is 3 minutes against hand tools, C5 is 5 minutes against heavier tools such as crowbars and drills, and D10 is 10 minutes against sledgehammers and disc cutters. No certificate means no rating, whatever the brochure implies.
What a comparison table does not prove
A comparison table proves one thing: how three products differ on paper. It proves nothing else. Treat the table as a starting point, and ask what it leaves out before the order is placed.
It does not prove the lane suits the lobby. A waist-high turnstile, a glass speed gate and a security portal all control one person at a time, but they ask different things of the building. A portal needs more floor space than a tripod lane, a speed gate needs a clear run for its glass leaves, and a lane that suits a quiet reception will queue at the morning peak when the whole building arrives at once.
It does not prove tailgating is stopped. A waist-high lane stops casual entry, but a person can climb over it or follow close behind the person in front. A glass optical lane with detection alarms when two people pass on one credential, and a portal with single person detection holds each person until the door behind them closes. The lane must match the risk the site actually carries.
It does not prove access control works. The readers, fobs and credentials decide who passes, and the lane is only the gate that carries them. A lane with no audit trail cannot say who entered or when, and a reader that fails in the rain leaves the entrance closed to the people it should let through.
It does not prove escape. Every lane must let people out fast when the alarm sounds, and the free exit and the wider accessible lane must work without a credential. A lane that needs power, a fob or a key to open in a fire is a lane that traps the people behind it.
Mistakes that leave a lobby entrance open
Most lobby entrances fail in small ways. Each mistake below has the same result: an entrance that looks controlled and lets people through unchecked.
| Mistake | Why it fails | What to do instead |
|---|---|---|
| Lane chosen from the table alone | The table says nothing about the floor space or the flow. | Measure the lobby and count the busiest hour first. |
| Waist-high lane where climb-over matters | A person can climb over a lane that only reaches the waist. | Fit a portal or a full-height lane where the risk needs it. |
| No wider lane for wheelchairs and deliveries | People and goods pass through the side gate unchecked. | Fit a wider lane with the same control as the rest. |
| Free exit never tested | A release that was never tripped may not work when the alarm sounds. | Test the free exit at every inspection. |
| Access control with no audit trail | Nobody can say who entered or when. | Log every passage and check the log. |
Keep the evidence with the entrance. The test report, the rating and the lane schedule should travel with the installation, so the next inspection can check what was fitted against what was tested. For the turnstile lane itself, see our security turnstiles guide, and for the fast lane for people on foot, see our pedestrian speed gates page.
Get a free quote
Related
More in guides for specifiers
Products
One supplier for the whole building envelope
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.