Certified physical security

ArxBridge
Office lobby with speed gates, a turnstile and a security portal

ArxBridge

Turnstile vs speed gate vs security portal: choosing entrance control

Turnstile vs speed gate vs security portal: a UK buyer's guide to choosing entrance control, comparing throughput, security, footprint and cost drivers.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed across the UK
Prefer to talk?+44 7352 267239

Get a free project quote

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Choose a speed gate for a busy UK office lobby where flow and appearance matter most. Choose a turnstile where the lane faces weather, crowds or rough treatment. Choose a security portal where only one verified person may pass, such as a data hall or cash office. The rest is detail: throughput, footprint, accessibility and cost.

  • Speed gateMotorised panels; fastest lane for busy lobbies
  • TurnstileRotating arms; simple and tough, inside or out
  • Security portalInterlocking doors; one verified person at a time
  • TailgatingThe misuse all three are designed to stop

What each stops: tailgating, piggybacking and forced entry

Tailgating means slipping through on someone else’s credential, close behind them. Piggybacking is the deliberate version, where an authorised person holds the way open. Forced entry is the physical attack: climbing over, crawling under or forcing the barrier. Each product answers a different mix of the three.

A tripod turnstile gives a mechanical one-at-a-time action. The rotating arms stop casual tailgating because the next person cannot pass until the arms reset. At waist height the arms can still be jumped or crawled under, so the deterrent works best where staff or cameras watch the lane.

A speed gate answers tailgating with sensors rather than arms. Detection zones watch the lane, and the controller can spot a second person, reverse entry or a forced panel, then sound an alarm and hold the barrier. The glass or acrylic panels are a deterrent, not a wall. They suit a supervised lobby where misuse is opportunistic, not determined.

A full-height turnstile or a full height glass turnstile answers forced entry at the lane. The rotor or glass leaves run floor to ceiling, so climbing over and crawling under are off the table. It is the right call for unsupervised points: car park stairs, transport interchanges and perimeter gates where nobody watches.

A security portal answers piggybacking, the case the others cannot fully close. Two interlocking doors and single person detection mean the second door only opens when the sensors confirm one occupant. Where the threat assessment names forced entry as well, ask whether the portal has been attack tested to LPS 1175. B3 means 3 minutes against hand tools such as screwdrivers, pliers and hand saws. C5 means 5 minutes against crowbars, drills and chisels. D10 means 10 minutes against sledgehammers, disc cutters and jigsaws.

Honest limit. None of the three replaces a rated security door where the specification demands a tested delay. Lanes control honest people and deter the casual intruder. A determined attacker with tools is a job for security doors tested to a named rating.

Throughput and footprint

Throughput is set by the whole transaction, not the barrier. Credential presentation, reader speed, failed reads, bags, mobility aids and direction changes all slow a lane. Size the lane count from your own arrival pattern, not from a brochure figure.

Speed gates are the fastest of the three in steady office flow. The panels start opening as the credential is read, so a familiar user barely breaks stride. Tripod turnstiles are slower and more deliberate: one push, one person, one reset. That rhythm suits shift changes and crowds because it never loses count, even if it never sprints.

Portals are the slowest by design. One person enters, the first door closes, the sensors check, the second door opens. The cycle buys certainty at the cost of flow, which is why portals guard the data hall while pedestrian speed gates guard the lobby.

Footprint follows the same order. A tripod lane is compact. A speed gate needs lane length for the panels and their sensor zones. A portal needs the deepest footprint of all: two door sets plus the interlock zone between them. Leave queue space on both sides at peak, and check the floor can take the fixings, especially outdoors or on retrofit installs.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

The morning peak: the hour the lane count must pass

The lane count should follow the people the entrance must pass at its busiest hour, not the people it sees through the day. A lane that passes a steady trickle all day and queues at the morning peak has too few lanes, because the whole building arrives at once and the entrance must pass them all before the working day starts.

The peak belongs on the order beside the lane count, with the busiest hour named and the number of people who must pass in that hour. A count taken from the average day leaves the entrance short at the peak, and a count taken from the peak leaves the lobby with lanes that stand empty for the rest of the day.

The lane type sets how many people each lane can pass, because a tripod lane passes fewer people than a glass speed gate, and a portal that holds each person until the door behind them closes passes fewer still. The count should follow the lane type, so a portal line needs more lanes than a tripod line for the same crowd.

The staff who arrive early and the visitors who arrive late ask different things of the lanes, because the staff pass through on a card they hold every day while the visitors wait at reception for a pass. The peak should count both, so the lanes that pass the staff in the morning also pass the visitors who arrive through the day.

The queue before the lanes: the space the lobby must hold

The queue the entrance must hold belongs on the plan beside the lanes, because a crowd that cannot fit before the lanes spills into the street or back through the doors it came in by. The lobby should hold the queue for the busiest hour, with room for the people who wait and the people who pass them by.

The reception desk should sit where the queue can see it, because the visitors who need a pass must reach the desk without crossing the queue. A desk hidden behind the lanes leaves the visitors to push through the crowd, and a desk beside the lanes lets the staff hand out passes while the queue moves.

The way out needs the same space as the way in, because the crowd that leaves at the end of the day is the same crowd that arrived in the morning. The lobby should hold the queue for the way out as well, so the lanes that let people in also let them out without a crush at the doors.

Part What it names What to check When
Peak hour Busiest hour named People who must pass Before the order
Lane type Tripod, speed gate or portal Passes per lane Before the order
Staff Cards held every day Pass at the peak Before the order
Visitors Pass from reception Desk beside the lanes Before the order
Queue Space before the lanes Holds the busiest hour Before the order

The lanes in full are covered in the security turnstiles guide, and the lane count and the building work beside it are worked through in the turnstile cost factors guide. Readers, releases and wiring beside a lane are covered in the door entry systems guide, and the rules for the shared parts of a public building are set out in the fire door regulations commercial buildings guide.

Look and the reception area

The entrance sets the tone of the building, and the three products read very differently. Speed gates are the lobby product: slim cabinets, glass panels and a quiet action that suits corporate receptions, banks and headquarters. They present security as a background service, not a checkpoint.

Full-height glass turnstiles keep the full-height deterrent but let light and sightlines through. Staff at the desk can see the lane, and visitors can see the reception beyond. The trade-off is housekeeping: glass shows fingerprints and needs regular cleaning to keep its look.

Tripod turnstiles read as functional: fine back of house and on perimeters, but heavy in a client-facing lobby. Security portals read as high security, which is exactly right for a data centre or a cash office and exactly wrong where you want visitors to relax.

Where the entrance must also impress and control draughts, a revolving security door is the related option. It manages airflow and presents a grander face, with access control built into the rotation. Our types of security doors guide places all of these in the wider family.

Waist height versus full height

Waist-height lanes control honest users. Tripod arms, optical beams and speed gate panels all stop the casual walk-through, but they can be climbed or crawled past by someone who decides to. That is acceptable where the lane is supervised or where the risk is nuisance rather than loss.

Full-height lanes remove the climb-over and crawl-under routes. A full-height rotor turnstile suits outdoor and unsupervised points: perimeter gates, plant compounds and transport sites where weather and rough treatment rule out delicate equipment. Full-height glass versions do the same job indoors where appearance still matters, for example at a transport hub entrance that runs unstaffed at night.

Full height brings its own demands. The units are taller, heavier and more imposing, they need a firm fixing and they must release safely on fire alarm. If the threat does not justify that, waist height plus supervision is the cheaper and friendlier answer.

Security portals and single person detection

A portal is an interlocking cabin: two door leaves with a small chamber between them. The first door opens on a valid credential and the person steps in. The first door closes. Only then do the sensors check the chamber, and only when they confirm a single occupant does the second door open. One credential, one person, every time.

Single person detection usually combines weight measurement with volumetric or infrared sensing. The logic must tell one person with a bag from two people close together, without trapping a nervous visitor. That is why portals need commissioning on site, with sensitivity set for the real users.

Specify a portal where a second person must never enter on one credential: data halls, server rooms, cash offices and research labs. Our data centre physical security guide shows where the portal sits in the layered plan. Do not specify one where flow matters more than certainty. A portal on a main staff entrance will queue the building.

Accessibility lanes and fire egress

The Equality Act 2010 requires service providers to make reasonable adjustments for disabled people, and entrance control is part of that duty. Standard lanes are too narrow for a wheelchair user, so the design needs at least one wider lane: a broad speed gate lane, a powered accessible gate or a supervised manual gate beside the bank. Plan it from the start, not as an afterthought.

Fire egress is the other non-negotiable. On fire alarm or power failure the lanes must release to free exit, and the behaviour must be agreed with the building’s fire risk assessment before anything is ordered. Full-height turnstiles need a fail-safe release or an adjacent escape gate. A portal must never be the only way out of the space it guards unless the escape strategy specifically allows it.

The Terrorism (Protection of Premises) Act 2025 adds context for larger sites: 200 to 799 people is the standard tier, 800 or more the enhanced tier, with the Security Industry Authority as regulator. Where those duties apply, entrance control and clear egress belong in the same plan.

Turnstile, speed gate or portal: side by side

Feature Turnstile Speed gate Security portal
Main threat stopped Casual tailgating; full height stops climb-over Sensor-detected tailgating and reverse entry Piggybacking; one person per credential
Throughput Moderate, one at a time Fastest in steady office flow Slowest, one cycle per person
Footprint Compact Needs lane length for panels Deepest: two doors plus chamber
Look Functional to industrial Sleek, suited to receptions Enclosed, reads as high security
Outdoor use Yes, full height suits perimeters Prefers indoor, sheltered lobbies Possible with weather-rated build
Accessibility Needs an adjacent wide lane Wide lanes available in the bank Needs an adjacent wide lane
Fire egress Fail-safe release or escape gate Panels open on alarm Interlock must release to exit
Best for Perimeters, stadia, unsupervised points Office lobbies and receptions Data halls, cash offices, labs

Access control integration and what drives the cost

The lane is only as good as the system behind it. Card readers, fobs, mobile credentials, QR codes and biometrics all present to the lane controller, which must talk to the existing access control platform. Confirm the interface early, plan power and data to each lane, and make sure visitor management and the intercom reach the same controller so guests are not stranded.

Cost drivers, without prices because every site differs: lane count and width; barrier material, where glass panels cost more than steel arms; detection and anti-tailgating sophistication; access control integration; floor works and outdoor foundations; finishes and branding; and the ongoing maintenance that keeps sensors aligned. A lane that is never serviced gets propped open. See the full guides hub for related comparisons.

Can someone tailgate through a speed gate?

The sensors are designed to spot it. A second person in the lane, reverse entry or a forced panel raises an alarm and the barrier holds. That works well against opportunists in a supervised lobby. It is not a wall, so where the threat is determined rather than casual, a full-height turnstile or a portal is the stronger answer.

Do turnstiles work outdoors?

Full-height turnstiles are the outdoor choice. They tolerate weather and rough treatment and need no supervision to stay effective. Tripod models can work under a canopy. Speed gates prefer a sheltered indoor lobby, where their sensors and finishes stay at their best.

What happens to the lanes in a fire or a power cut?

They must fail safe to free exit, opening or releasing so people can leave. The exact behaviour is set with the building’s fire risk assessment before the order, and full-height units need a fail-safe release or an adjacent escape gate.

Can a wheelchair user get through?

Not through a standard lane, which is too narrow. The Equality Act 2010 duty of reasonable adjustment means the design should include at least one wider lane, such as a broad speed gate lane or a supervised accessible gate beside the bank.

Which should a data centre choose?

Both, in different places. Speed gates suit the office lobby where staff flow matters, and a security portal guards the data hall. The data centre physical security guide linked above maps the layers.

When is a rated portal worth asking for?

When the threat assessment names forced entry, not just tailgating. Ask for the attack test evidence. To LPS 1175, B3 is 3 minutes against hand tools, C5 is 5 minutes against heavier tools such as crowbars and drills, and D10 is 10 minutes against sledgehammers and disc cutters. No certificate means no rating, whatever the brochure implies.

What a comparison table does not prove

A comparison table proves one thing: how three products differ on paper. It proves nothing else. Treat the table as a starting point, and ask what it leaves out before the order is placed.

It does not prove the lane suits the lobby. A waist-high turnstile, a glass speed gate and a security portal all control one person at a time, but they ask different things of the building. A portal needs more floor space than a tripod lane, a speed gate needs a clear run for its glass leaves, and a lane that suits a quiet reception will queue at the morning peak when the whole building arrives at once.

It does not prove tailgating is stopped. A waist-high lane stops casual entry, but a person can climb over it or follow close behind the person in front. A glass optical lane with detection alarms when two people pass on one credential, and a portal with single person detection holds each person until the door behind them closes. The lane must match the risk the site actually carries.

It does not prove access control works. The readers, fobs and credentials decide who passes, and the lane is only the gate that carries them. A lane with no audit trail cannot say who entered or when, and a reader that fails in the rain leaves the entrance closed to the people it should let through.

It does not prove escape. Every lane must let people out fast when the alarm sounds, and the free exit and the wider accessible lane must work without a credential. A lane that needs power, a fob or a key to open in a fire is a lane that traps the people behind it.

Mistakes that leave a lobby entrance open

Most lobby entrances fail in small ways. Each mistake below has the same result: an entrance that looks controlled and lets people through unchecked.

Mistake Why it fails What to do instead
Lane chosen from the table alone The table says nothing about the floor space or the flow. Measure the lobby and count the busiest hour first.
Waist-high lane where climb-over matters A person can climb over a lane that only reaches the waist. Fit a portal or a full-height lane where the risk needs it.
No wider lane for wheelchairs and deliveries People and goods pass through the side gate unchecked. Fit a wider lane with the same control as the rest.
Free exit never tested A release that was never tripped may not work when the alarm sounds. Test the free exit at every inspection.
Access control with no audit trail Nobody can say who entered or when. Log every passage and check the log.

Keep the evidence with the entrance. The test report, the rating and the lane schedule should travel with the installation, so the next inspection can check what was fitted against what was tested. For the turnstile lane itself, see our security turnstiles guide, and for the fast lane for people on foot, see our pedestrian speed gates page.

Choosing entrance control for your lobby or perimeter?Tell us the footfall, the threat and the look you need, and we will configure the right lanes.
Get a free quote

Related

More in guides for specifiers

10 mistakes when specifying certified security doors 10 steps to specify an LPS 1175 door Acceptance and Snagging of a Security Door or Barrier Job Access Control Doors Acoustic Doors: Ratings and Specification After a Forced Entry Attempt: Checking a Security Door Airport Security Doors Anti-Ligature Doors for Mental Health Wards Anti-Ram Bollards Anti-ram gates and barriers: protecting vehicle entrances Arcade Security Doors Explained Automatic Doors Automatic Gates Cost Factors Automatic Vehicle Barriers Ballistic Panels Bank Security Doors Bingo Hall Security Doors Explained Blast doors: glazed vs solid and how they are rated Blast protection window film: what it does and what it cannot do Blast resistant windows: what drives the cost and how to specify them Bollard Cost Factors Explained Bollard regulations in the UK: spacing, height and depth Bookmaker Security Doors Explained Builders Merchant Security Doors Bullet Resistant Glass Cost Factors Bullet resistant glass ratings explained: BR1 to BR7 and SG classes Bullet resistant vs bulletproof glass: what the difference means Buying Security Doors and HVM Through Public Frameworks Car Park Security Doors Explained Car Showroom Security Doors Casino Security Doors Explained CDM 2015 Duties When Security Doors, Shutters or HVM Are Installed Cinema Security Doors Cleanroom Doors Cold Store Doors College Security Doors Commissioning, Handover and the O&M Manual for Security Doors and HVM Communal entrance doors for flats: Secured by Design and what to specify Community Centre Security Doors Control Room Doors Court Security Doors Crash Rated Fences and HVM Fencing Explained Data centre physical security: doors, glazing, HVM and shielding by zone Dental Practice Security Doors Depot Security Doors Explained Door Entry Systems Due Diligence When Selecting Vehicle Security Barriers Emergency Exit Doors EMP Shielding Cost Factors Explained Exhibition Centre Fire Door Rules Exhibition Centre Security Doors Factory Security Doors Faraday cage vs RF shielded room: what a business needs FB4 vs FB6 vs FB7: how to choose a ballistic rating Fire and security doors: how dual certification works Fire Compartmentation Fire Curtains Fire Door Certification Fire Door Closers Explained Fire Door Cost Factors Fire Door Duties of the Accountable Person Fire Door Gaps Fire Door Hardware Explained Fire door inspection checklist for steel and timber doors Fire Door Maintenance Fire Door Regulations Care Homes Fire Door Regulations for A and E Departments Fire Door Regulations for Airports Explained Fire Door Regulations for Bowls Clubs Fire door regulations for commercial buildings in the UK Fire Door Regulations for Dialysis Centres Fire Door Regulations for Hockey Clubs Fire Door Regulations for Hospitals Explained Fire Door Regulations for Offices Explained Fire Door Regulations for Operating Theatres Fire Door Regulations for Retail Explained Fire Door Regulations for Schools Explained Fire Door Regulations for Snooker Clubs Fire Door Regulations for Stadiums Fire Door Regulations for Student Accommodation Fire Door Regulations for Warehouses Fire Door Regulations Leisure Centres Fire Door Regulations Restaurants Fire Door Remediation Programme for Housing Providers Fire Door Rules for Badminton Clubs Fire Door Rules for Bingo Halls Fire Door Rules for Bookmakers Fire Door Rules for Bowling Alleys Fire Door Rules for Car Parks Fire Door Rules for Car Showrooms Fire Door Rules for Cinemas Fire Door Rules for Climbing Centres Fire Door Rules for Colleges Fire Door Rules for Community Centres Fire Door Rules for Cricket Clubs Fire Door Rules for Dental Practices Fire Door Rules for Depots Explained Fire Door Rules for Golf Clubs Fire Door Rules for GP Surgeries Fire Door Rules for Gyms Explained Fire Door Rules for Ice Rinks Fire Door Rules for Maternity Units Fire Door Rules for Mental Health Units Fire Door Rules for Museums Fire Door Rules for Oncology Units Fire Door Rules for Opticians Fire Door Rules for Pawnbrokers Fire Door Rules for Petrol Stations Fire Door Rules for Pharmacies Fire Door Rules for Ports Fire Door Rules for Post Offices Fire Door Rules for Prisons Fire Door Rules for Rehabilitation Centres Fire Door Rules for Self Storage Fire Door Rules for Shopping Centres Fire Door Rules for Squash Clubs Fire Door Rules for Supermarkets Fire Door Rules for Swimming Pools Fire Door Rules for Tennis Clubs Fire Door Rules for Theatres Fire Door Rules for UK Arcades Fire Door Rules for UK Casinos Fire Door Rules for UK Hospices Fire Door Rules for Walk-in Centres Fire Door Signage Fire Door Vision Panels Fire Doors and Gateway 2 in Higher-Risk Buildings Fire Rated Glass Cost Explained Fire Rated Sliding Doors Explained Fire Rated Windows Cost Factors Fire Rated Windows Explained Fire Safety Enforcement Notices and Fire Doors: What the Responsible Person Must Do Flat Entrance Doors: PAS 24 and Fire Rated Forced Entry vs Ballistic vs Blast: Which Rating a Site Needs Garage Security Doors Explained Gate Automation Explained Golden Thread Records for Fire Doors GP Surgery Security Doors Explained Gym Security Doors Explained High Speed Doors HMO Fire Doors Hospice Security Doors Explained Hospital Security Doors: Wards, A&E, Plant Hospital Security Gates Hotel Fire Doors Hotel Security Doors How to choose HVM bollards: fixed, shallow mount, removable and automatic How to keep an LPS 1175 door rating valid after installation How to Specify Fire Doors in a Housing Tender How to specify security doors: a checklist for architects How to Verify a Secured by Design Listing How to Verify an LPS 1175 Certificate on Red Book Live How to Write an Operational Requirement for Physical Security HVM planters and street furniture: protection that blends in In-Service Care of Vehicle Security Barriers Installation Handover: LPS 1175 Doors and PAS 68 Barriers Intumescent Seals ISO 16933 explained: EXV and SB classes and hazard ratings ISO 22343 vehicle security barriers explained Keeping a Dual-Certified Fire and Security Door Valid in Service Laboratory Security Doors Layered Security for a Site: Deter, Detect, Delay, Mitigate, Respond Lead Times and Programme Risks for LPS 1175 Doors Leisure Centre Security Doors Library Security Doors Listed Building Fire Doors Loading Bay Doors Explained Lockdown and Access Control Hardware on an LPS 1175 Door LPS 1175 Gates and Grilles Explained LPS 1175 Issue 8 explained: from SR1 to SR8 to A1 to H20 LPS 1175 Roller Shutters LPS 1175 vs ASTM F2781 and Other US Ratings Explained LPS 1175 vs EN 1627: how UK and European burglar resistance ratings compare LPS 1175 vs PAS 24: which security standard does your door need? LPS 1175 Windows and Walling Explained Martyn’s Law and Places of Worship: What a Buyer Checks for Doors and Entry Control Martyn’s Law Enhanced Tier: Physical Measures and the Specifier Brief Martyn’s Law Standard Tier: Procedures, Doors and Shutters Martyn’s Law Timeline and the SIA Regulator Martyn’s Law: what premises must do and which physical measures to consider Master Key Systems MRI and RF shielded rooms: how they work and what to specify Museum Security Doors NPSA Catalogue of Security Equipment (CSE) Explained NPSA Forced Entry and Blast Guidance for Government Sites NPSA Guidance on Lockdown and Marauding Attack: What It Asks of Doors and Entrances Office Security Doors Optician Security Doors Explained Panic Hardware PAS 24 requirements for doors and windows explained PAS 68 Bollard Foundations Explained PAS 68 bollards: ratings, spacing and cost factors PAS 68 vs IWA 14 vs ISO 22343: hostile vehicle mitigation standards explained Pawnbroker Security Doors Explained Pedestrian Gates Petrol Station Security Doors Pharmacy Security Doors Planning Permission for Security Shutters, Gates and Bollards on Commercial Premises Plant room doors: fire, security and ventilation requirements Plant Room Fire Doors Port Security Doors Post Office Security Doors Explained Powder coating vs galvanising vs paint for steel Preliminary Market Engagement for Security Doors and HVM Prison Security Doors Programming a Security Door and Barrier Package on a Live Site Public-Sector Tender Response Checklist for Security Door and HVM Supply Reading a PAS 24 and SBD Door Test Report Regulation 38 Fire Safety Information at Handover for Fire-Rated Security Doorsets Replacing Security Doors in an Occupied Building Restaurant Security Doors Retail Security Doors Revolving Doors RF shielding standards and how shielded rooms are tested Rising Bollard Cost Factors Road Blocker Cost Factors Explained Road Blockers Explained Roller Shutter Cost Factors: What Drives the Price Roller shutter regulations in the UK: safety and maintenance Safe room and panic room doors: specification basics Safety Duties for Powered Doors, Gates and Barriers on Commercial Sites School Security Doors Sectional Doors Secured by Design explained: is it mandatory for doors? Secured by Design vs NPSA vs LPCB: Which One You Need Security Door Locks Security Door Maintenance Checklist Security Doors and Access for Everyone: What Approved Document M Asks Security Doors for A and E Departments Security Doors for Badminton Clubs Security Doors for Bowling Alleys Security Doors for Bowls Clubs Security Doors for Climbing Centres Security Doors for Cricket Clubs Security Doors for Dialysis Centres Security Doors for Golf Clubs Security Doors for Hockey Clubs Security Doors for Ice Rinks Security Doors for Maternity Units Security Doors for Mental Health Units Security Doors for Oncology Units Security Doors for Operating Theatres Security Doors for Rehabilitation Centres Security Doors for Snooker Clubs Security Doors for Squash Clubs Security Doors for Swimming Pools Security Doors for Tennis Clubs Security Doors for Walk-in Centres Security Doors West Midlands Explained Security Fencing Security Gates Cost Factors Explained Security shutters vs high performance roller doors Security shutters vs retractable grilles: which suits retail and commercial openings? Security Turnstiles Explained Security Window Film Security Windows for Schools Explained Self Storage Security Doors Server Room Doors Explained Shopping Centre Security Doors Smoke Control Doors Explained Smoke Curtains Specification Mistakes When Mixing LPS 1175, PAS 24 and SBD in One Tender SR2 vs SR3 vs SR4 security doors: choosing the right LPS 1175 level Stadium Security Doors Steel Door Frames Steel vs aluminium security doors: strength, ratings and looks Steel vs timber fire doors: which suits your building? Student Accommodation Security Doors Substation doors: security, ventilation and specification Supermarket Security Doors Telescopic Bollards Tender Evaluation Criteria and Scoring for Security Doors and HVM The Scope of a Maintenance Contract for Security Doors and Barriers Theatre Security Doors Thermal and Weather Performance of External Security Doorsets Thermally broken steel security doors: U-values and certification Traffic Calming as Hostile Vehicle Mitigation Transport hub security requirements Turnstile Cost Factors Explained Types of security doors for commercial buildings University Security Doors Explained Vehicle Dynamics Assessment: What It Tells the Buyer Before a Barrier Is Specified Warehouse Security Doors Explained Warehouse Security Gates Warranty, Defects Liability and Guarantees for Security Doors and Barriers What affects the cost of a bullet resistant door What affects the cost of a high-security door in the UK Window Security Bars View all →

Products

One supplier for the whole building envelope

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.