Security Doors for Walk-in Centres

A walk-in centre takes patients with no appointment, so each leaf takes the LPS 1175 grade its room demands, B3 at the entrance and D10 at the drugs store.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed across the UK
Prefer to talk?+44 7352 267239

Get a free project quote

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

A walk-in centre takes patients through the day with no appointment, so the waiting room fills with people who arrived unannounced and the treatment rooms turn over from one patient to the next. The entrance takes the arrivals in, reception takes their names, the waiting room holds them till their turn comes, the treatment rooms hold the examination and the care, the drugs store holds the medicines, the staff office holds the records and the plant room keeps the lights and the air moving.

LPS 1175 Issue 8.2, dated September 2024, grades a leaf by the minutes it stands against the tools the test names. Three minutes is the hold of a B3 leaf, five minutes the hold of a C5 leaf and ten minutes the hold of a D10 leaf, and drawings drawn before the rename may still call the same three leaves SR2, SR3 and SR4, so the order carries both names beside each leaf.

A walk-in centre is not a GP surgery, because no patient books a time and no consultation is planned in advance, and it is not a hospital, because no one stays overnight and no ward sits behind the doors, and it is not a pharmacy, because the rooms behind the front hold treatment rather than a counter. The security doors for GP surgeries guide grades the doors of a building that books its patients in, and the security doors for pharmacies guide grades the doors round a counter and a dispensary.

  • B3 / C5 / D10Grades to LPS 1175 Issue 8.2
  • Drugs storeWhere D10 sits in the centre
  • No appointmentPatients arrive through the day
  • One listEvery centre leaf named

Seven rooms in a walk-in centre: the grade each leaf takes

Seven rooms make up a walk-in centre, and the grade follows what each room holds. The seven rooms are the entrance, reception, the waiting room, the treatment rooms, the drugs store, the staff office and the plant room, and the grade on each leaf follows what sits behind it.

B3 sits on the entrance, reception and the waiting room, because all three stand where patients and staff can see them through the day. C5 goes on the treatment rooms, the staff office and the plant room, because the care, the records and the plant behind those leaves ask for a longer hold than the public rooms. The drugs store takes D10, because the medicines behind it are the most portable value in the building.

Every opening is named on its own line of the order, with the leaf, the grade and the minutes written beside it, so the fitter checks each leaf against its line before hanging it.

Room Grade Minutes What to check
Entrance B3 3 Leaf, lock, closer
Reception B3 3 Leaf, lock, reader
Waiting room B3 3 Leaf, lock, closer
Treatment rooms C5 5 Leaf, lock, seals
Drugs store D10 10 Leaf, lock, hinges
Staff office C5 5 Leaf, lock, reader
Plant room C5 5 Leaf, lock, seals

One leaf in the centre can carry the fire proof and the forced entry proof together, so a single report holds both. The fire minutes run from 30 to 120 under EN 1634-1, and the letter after the number says what stayed back, E for flame on its own, EW for flame with some of the heat, EI for flame with the heat as well. The fire and security doors dual certification guide shows the pair proved on the same leaf, and the SR2 vs SR3 vs SR4 guide puts the old names beside the new grades.

The entrance, reception and waiting room: B3 where patients arrive

Patients arrive at the entrance with no booking, so the leaf between the street and reception stays shut and locked between each arrival. The leaf must open fast to a card or a key in staff hands, and it must shut fully behind them.

The entrance asks for three minutes because it stands in sight of the staff at reception. A reader on the street side opens the leaf to staff cards, and a key override stands behind the reader for the day the reader fails. The access control doors guide covers readers and locks on a centre leaf, and the door entry systems guide covers the panel that lets staff through from the street.

A patient pushing the entrance leaf meets a limit set by BS 8300 and Approved Document M, under 30 N across the first 30 degrees of swing and under 22.5 N after that, so the leaf opens for a person leaning on a stick or carrying a child. The closer that shuts the leaf carries a proof to BS EN 1154, and EN 1 stands as the smallest power size the standard names.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

No patient waits at a shut entrance

The entrance door opens for every arrival through the clinic day, because the walk-in centre takes patients who arrive without appointments. A patient walks in from the street, the door opens to them, and the door shuts behind them, so the front stays shut to the street while the waiting room fills inside.

The reader at the street side answers a staff card and keeps the door shut to every other card, so staff pass through while patients come in through the same door at the front. A spare key stands behind the reader for the day it stops working, and the key is kept where the clinician in charge can reach it at once. The reader is tried each morning before the first patient arrives.

The doors on the way out carry a bar proved to BS EN 1125 on every route that serves more than 60 people, with the bar spanning at least three fifths of the door width, so a crowd pressing on it gets the door open at once. The panic hardware guide names the bar that throws the door open when the waiting room empties at once.

Point in the day Door state Who moves it
First arrival Opened, then drawn shut Patient at the front
Midday queue Shut after each arrival Reception staff
Last patient Shut, latch caught Clinician closing the centre

Bollards guard the frontage where the queue stood, set with gaps of no more than 1,200 mm between them and each post at least 500 mm high, as ProtectUK sets it. The choosing HVM bollards guide shows where the posts stand along the frontage.

The reader answers a card for every member of staff

The list beside the reader names each card holder, so a new member of staff joins it on their first day and a lost card comes off it the day it is reported. The door entry systems guide covers the panels a centre fits at its front.

Once a month the clinician in charge goes round the centre with the door list, working each door in turn, and a door that will not shut or a lock that will not turn goes on the list beside its own room that same day. What that walk should cover is set out in the security door maintenance checklist guide.

The round reaches each door with the same checks, from the seal to the gap, and the fire door inspection checklist runs through the checks for each door as the round reaches it.

The entrance door is opened for every arrival and shut behind each one, and the door that takes that duty all day must still sit true in its frame at the end of it. A door that drags on its hinges or a bolt that misses its keep goes on the list the same day it turns up.

The centre sends its rooms to the healthcare doors quote as the day runs, entrance first and drugs store last, with the grade beside each one.

Treatment rooms: C5 on the leaf that shuts while a patient is treated

A treatment room holds a patient mid-treatment, so its leaf takes C5 and stays shut while the clinician works inside. The lock on the room side lets the clinician open it at once when the treatment ends.

The leaf hangs on hinges proved to BS EN 1935, grade 13 proved through 200,000 cycles under a leaf of 120 kg and grade 14 proved through the same cycles under a leaf of 160 kg, so the leaf stays square in its frame and the bolt keeps meeting its keep.

A panel set high in the leaf lets staff see whether the room is in use without opening it, and the panel goes through the test with the leaf, so the report names the glass and its fixings beside the leaf. The hospital security doors guide grades the doors of a building where patients stay overnight.

The drugs store: D10 behind the medicines

The drugs store holds the medicines, so its leaf takes D10, the longest hold LPS 1175 Issue 8.2 names. The leaf, the frame, the fixings and the lock were tested as one doorset, and the report gives ten minutes against the tools the test names, because the medicines counted inside are the easiest value in the building to carry out. No published table lines LPS 1175 grades up against ASTM ratings, so the order carries the LPS grade alone and no other rating beside it.

The drugs store leaf carries no glass, because a pane would let the corridor see the medicines and would put a hand close to the lock. The leaf stays shut whenever no one is working inside.

TS 007 counts a 1 star cylinder with a 2 star handle as a 3 star set, so the pair is ordered together and neither half is bought alone. The security door locks guide names what the lock on the drugs store must do, and the keys to the room are held by named staff only.

Staff office and plant room: C5 on the rooms behind the front desk

The staff office holds the patient records and the papers that run the centre, so C5 sits on its leaf and the leaf stays locked when the room is empty, because an open office would hand a passer by the records and the keys to the rooms behind it.

The plant room holds the boards and the equipment that keep the lights, the heating and the air moving, so its leaf takes C5 as well. The plant room door requirements guide names in full what a leaf on that room must do.

Staff move between the office and reception through the day, so the leaf between the two rooms needs to shut by itself after every pass. The closer on it is proved to BS EN 1154, and a fire leaf takes no power size below EN 3.

Locks, readers and keys: who opens which leaf through the day

Each leaf behind reception opens to the cards and keys of the staff who work there, and a card held on the public side opens none of them. A key plan that gives each holder the rooms their work needs, and no room beyond those, is set out in the master key systems guide.

The clinician in charge holds a key that opens every leaf behind reception, and the reception staff hold keys that open only the rooms their shifts take them to. How the order runs from the first leaf to the last is set out in the 10 steps to specify an LPS 1175 door guide. A lost card is taken off the reader list the day it is reported, so a card found on the waiting room floor opens nothing.

Bollards and the waiting room at the end of the day

The waiting room can still hold a full room of people at once, so the leaves on the way out must let them move fast while a vehicle stays off the frontage. A push bar proved to BS EN 1125 runs across the leaves on the way out wherever the route serves more than 60 people, and the bar covers no less than 60 percent of the leaf width, so one push from a person in a crowd throws the leaf open. The panic hardware guide names what the bar must do when a crowd pushes against the leaf.

Royal Assent came for Martyn’s Law in April 2025 and the start is expected in spring 2027, with the lower tier covering premises that may hold 200 to 799 people and the higher tier covering 800 or more. A centre whose waiting room may hold that many people falls inside those tiers. What each tier asks of the building is named in the Martyn’s Law guide for premises.

A vehicle is kept off the frontage by bollards, and ProtectUK sets the clear gap between them at 1,200 mm at most, with each bollard standing at least 500 mm high. The choosing HVM bollards guide covers how the frontage is laid out.

One last walk round locks every leaf in turn

When the last patient leaves, the waiting room empties, and the leaves are shut and locked in turn, starting with the treatment rooms and ending with the drugs store leaf, which is checked last before the doors are locked for the night. The last person out walks the rooms in the same order every evening, so no leaf is left to chance and no room is skipped because the day ran late. The clinician in charge holds the list for that walk, and each leaf is tried with its own key before the building is left for the night.

The leaves on the way out carry a bar proved to BS EN 1125 on every route that serves more than 60 people, with the bar spanning at least three fifths of the leaf width, so a crowd pressing on it gets the leaf open at once. The guide to panic hardware names the bar that throws the leaf open when the waiting room empties at once.

Time Leaf Check
End of day Treatment rooms Shut and locked
End of day Drugs store Tried last, lock turned
Night Entrance Locked from inside

Where the queue stood through the day, bollards stand through the night, with no more than 1,200 mm of clear gap between them and each one standing at least 500 mm high, as ProtectUK sets it. The guide to choosing HVM bollards shows where the posts stand along the frontage.

Staff open the entrance leaf with a card at the street side reader, and a spare key stands behind the reader for the day it stops working. The guide to door entry systems covers the panels a centre fits at its front.

The leaf on the drugs store gets its try after every other leaf, because it guards the medicines and it must stand shut before the building empties. It is tried with its key, watched as the closer draws it home, and locked with a turn of the key, and a fault found on that last round is written down the same evening, so the leaf is put right before the next morning.

The bollards stand where the queue stood so that no vehicle reaches the frontage

Once a month the clinician in charge goes round the centre with the door list, working each leaf in turn, and a leaf that will not shut or a lock that will not turn goes on the list beside its own door that same day. A leaf that drags on its hinges or a bolt that misses its keep goes on the list beside its own door that same day. What that walk should cover is named in the security door maintenance checklist guide.

The round reaches each leaf with the same checks, from the seal to the gap, and the fire door inspection checklist runs through the checks for each leaf as the round reaches it.

The centre order is drawn up room by room, and the healthcare doors quote page covers the waiting room, the treatment rooms and the drugs store one by one, so the leaves and the bollards are priced together.

The walk-in centre order: every leaf, its grade and its lock

The whole order sits on one list, with a line for every opening that names the leaf, the grade, the lock and the closer beside it. A leaf with no line of its own may end up hung where it does not belong, and a C5 leaf on the drugs store would hold for five minutes where the medicines ask for ten.

The clinician in charge takes the door list round the centre each month and tries the leaves in turn. A leaf that drags, a bolt that misses its keep or a reader that stays silent is written beside its own door the day it is found, and the security door maintenance checklist names what the walk should cover.

The order is read leaf by leaf before anyone signs it, because a closer that turns up after the doorset holds the whole job up. What the order must hold for every door is set out in the how to specify security doors guide, and the steel door frames guide names how the frame holds the leaf and the lock together.

The grade on a walk-in centre leaf follows the room behind it, so the leaf, the lock and the reader are ordered together and checked together against the medicines and the patients behind the leaf.

What grade does a walk-in centre entrance take?

B3 to LPS 1175 Issue 8.2, which holds for three minutes, because the entrance stands in view of the staff at reception through the day.

What grade does a drugs store take?

D10 to LPS 1175 Issue 8.2, which holds for ten minutes, because the medicines sit behind a leaf that is shut and locked whenever no one is working inside.

What grade does a treatment room leaf take?

C5 to LPS 1175 Issue 8.2, which holds for five minutes, because the room holds a patient mid-treatment behind a shut leaf.

Can one leaf hold fire and forced entry?

Yes, where one leaf went through the fire test and the forced entry test, so a single report names the period and the grade together.

Who checks the walk-in centre doors?

The clinician in charge walks the centre with the door list each month and tries the leaves in turn, so a fault is found and put right.

Specifying security doors for a walk-in centre?Send the door list with the grade and the lock each room must hold for a tested door quotation.
Get a free quote

Related

More in guides for specifiers

10 mistakes when specifying certified security doors 10 steps to specify an LPS 1175 door Acceptance and Snagging of a Security Door or Barrier Job Access Control Doors Acoustic Doors: Ratings and Specification After a Forced Entry Attempt: Checking a Security Door Airport Security Doors Anti-Ligature Doors for Mental Health Wards Anti-Ram Bollards Anti-ram gates and barriers: protecting vehicle entrances Arcade Security Doors Explained Automatic Doors Automatic Gates Cost Factors Automatic Vehicle Barriers Ballistic Panels Bank Security Doors Bingo Hall Security Doors Explained Blast doors: glazed vs solid and how they are rated Blast protection window film: what it does and what it cannot do Blast resistant windows: what drives the cost and how to specify them Bollard Cost Factors Explained Bollard regulations in the UK: spacing, height and depth Bookmaker Security Doors Explained Builders Merchant Security Doors Bullet Resistant Glass Cost Factors Bullet resistant glass ratings explained: BR1 to BR7 and SG classes Bullet resistant vs bulletproof glass: what the difference means Buying Security Doors and HVM Through Public Frameworks Car Park Security Doors Explained Car Showroom Security Doors Casino Security Doors Explained CDM 2015 Duties When Security Doors, Shutters or HVM Are Installed Cinema Security Doors Cleanroom Doors Cold Store Doors College Security Doors Commissioning, Handover and the O&M Manual for Security Doors and HVM Communal entrance doors for flats: Secured by Design and what to specify Community Centre Security Doors Control Room Doors Court Security Doors Crash Rated Fences and HVM Fencing Explained Data centre physical security: doors, glazing, HVM and shielding by zone Dental Practice Security Doors Depot Security Doors Explained Door Entry Systems Due Diligence When Selecting Vehicle Security Barriers Emergency Exit Doors EMP Shielding Cost Factors Explained Exhibition Centre Fire Door Rules Exhibition Centre Security Doors Factory Security Doors Faraday cage vs RF shielded room: what a business needs FB4 vs FB6 vs FB7: how to choose a ballistic rating Fire and security doors: how dual certification works Fire Compartmentation Fire Curtains Fire Door Certification Fire Door Closers Explained Fire Door Cost Factors Fire Door Duties of the Accountable Person Fire Door Gaps Fire Door Hardware Explained Fire door inspection checklist for steel and timber doors Fire Door Maintenance Fire Door Regulations Care Homes Fire Door Regulations for A and E Departments Fire Door Regulations for Airports Explained Fire Door Regulations for Bowls Clubs Fire door regulations for commercial buildings in the UK Fire Door Regulations for Dialysis Centres Fire Door Regulations for Hockey Clubs Fire Door Regulations for Hospitals Explained Fire Door Regulations for Offices Explained Fire Door Regulations for Operating Theatres Fire Door Regulations for Retail Explained Fire Door Regulations for Schools Explained Fire Door Regulations for Snooker Clubs Fire Door Regulations for Stadiums Fire Door Regulations for Student Accommodation Fire Door Regulations for Warehouses Fire Door Regulations Leisure Centres Fire Door Regulations Restaurants Fire Door Remediation Programme for Housing Providers Fire Door Rules for Badminton Clubs Fire Door Rules for Bingo Halls Fire Door Rules for Bookmakers Fire Door Rules for Bowling Alleys Fire Door Rules for Car Parks Fire Door Rules for Car Showrooms Fire Door Rules for Cinemas Fire Door Rules for Climbing Centres Fire Door Rules for Colleges Fire Door Rules for Community Centres Fire Door Rules for Cricket Clubs Fire Door Rules for Dental Practices Fire Door Rules for Depots Explained Fire Door Rules for Golf Clubs Fire Door Rules for GP Surgeries Fire Door Rules for Gyms Explained Fire Door Rules for Ice Rinks Fire Door Rules for Maternity Units Fire Door Rules for Mental Health Units Fire Door Rules for Museums Fire Door Rules for Oncology Units Fire Door Rules for Opticians Fire Door Rules for Pawnbrokers Fire Door Rules for Petrol Stations Fire Door Rules for Pharmacies Fire Door Rules for Ports Fire Door Rules for Post Offices Fire Door Rules for Prisons Fire Door Rules for Rehabilitation Centres Fire Door Rules for Self Storage Fire Door Rules for Shopping Centres Fire Door Rules for Squash Clubs Fire Door Rules for Supermarkets Fire Door Rules for Swimming Pools Fire Door Rules for Tennis Clubs Fire Door Rules for Theatres Fire Door Rules for UK Arcades Fire Door Rules for UK Casinos Fire Door Rules for UK Hospices Fire Door Rules for Walk-in Centres Fire Door Signage Fire Door Vision Panels Fire Doors and Gateway 2 in Higher-Risk Buildings Fire Rated Glass Cost Explained Fire Rated Sliding Doors Explained Fire Rated Windows Cost Factors Fire Rated Windows Explained Fire Safety Enforcement Notices and Fire Doors: What the Responsible Person Must Do Flat Entrance Doors: PAS 24 and Fire Rated Forced Entry vs Ballistic vs Blast: Which Rating a Site Needs Garage Security Doors Explained Gate Automation Explained Golden Thread Records for Fire Doors GP Surgery Security Doors Explained Gym Security Doors Explained High Speed Doors HMO Fire Doors Hospice Security Doors Explained Hospital Security Doors: Wards, A&E, Plant Hospital Security Gates Hotel Fire Doors Hotel Security Doors How to choose HVM bollards: fixed, shallow mount, removable and automatic How to keep an LPS 1175 door rating valid after installation How to Specify Fire Doors in a Housing Tender How to specify security doors: a checklist for architects How to Verify a Secured by Design Listing How to Verify an LPS 1175 Certificate on Red Book Live How to Write an Operational Requirement for Physical Security HVM planters and street furniture: protection that blends in In-Service Care of Vehicle Security Barriers Installation Handover: LPS 1175 Doors and PAS 68 Barriers Intumescent Seals ISO 16933 explained: EXV and SB classes and hazard ratings ISO 22343 vehicle security barriers explained Keeping a Dual-Certified Fire and Security Door Valid in Service Laboratory Security Doors Layered Security for a Site: Deter, Detect, Delay, Mitigate, Respond Lead Times and Programme Risks for LPS 1175 Doors Leisure Centre Security Doors Library Security Doors Listed Building Fire Doors Loading Bay Doors Explained Lockdown and Access Control Hardware on an LPS 1175 Door LPS 1175 Gates and Grilles Explained LPS 1175 Issue 8 explained: from SR1 to SR8 to A1 to H20 LPS 1175 Roller Shutters LPS 1175 vs ASTM F2781 and Other US Ratings Explained LPS 1175 vs EN 1627: how UK and European burglar resistance ratings compare LPS 1175 vs PAS 24: which security standard does your door need? LPS 1175 Windows and Walling Explained Martyn’s Law and Places of Worship: What a Buyer Checks for Doors and Entry Control Martyn’s Law Enhanced Tier: Physical Measures and the Specifier Brief Martyn’s Law Standard Tier: Procedures, Doors and Shutters Martyn’s Law Timeline and the SIA Regulator Martyn’s Law: what premises must do and which physical measures to consider Master Key Systems MRI and RF shielded rooms: how they work and what to specify Museum Security Doors NPSA Catalogue of Security Equipment (CSE) Explained NPSA Forced Entry and Blast Guidance for Government Sites NPSA Guidance on Lockdown and Marauding Attack: What It Asks of Doors and Entrances Office Security Doors Optician Security Doors Explained Panic Hardware PAS 24 requirements for doors and windows explained PAS 68 Bollard Foundations Explained PAS 68 bollards: ratings, spacing and cost factors PAS 68 vs IWA 14 vs ISO 22343: hostile vehicle mitigation standards explained Pawnbroker Security Doors Explained Pedestrian Gates Petrol Station Security Doors Pharmacy Security Doors Planning Permission for Security Shutters, Gates and Bollards on Commercial Premises Plant room doors: fire, security and ventilation requirements Plant Room Fire Doors Port Security Doors Post Office Security Doors Explained Powder coating vs galvanising vs paint for steel Preliminary Market Engagement for Security Doors and HVM Prison Security Doors Programming a Security Door and Barrier Package on a Live Site Public-Sector Tender Response Checklist for Security Door and HVM Supply Reading a PAS 24 and SBD Door Test Report Regulation 38 Fire Safety Information at Handover for Fire-Rated Security Doorsets Replacing Security Doors in an Occupied Building Restaurant Security Doors Retail Security Doors Revolving Doors RF shielding standards and how shielded rooms are tested Rising Bollard Cost Factors Road Blocker Cost Factors Explained Road Blockers Explained Roller Shutter Cost Factors: What Drives the Price Roller shutter regulations in the UK: safety and maintenance Safe room and panic room doors: specification basics Safety Duties for Powered Doors, Gates and Barriers on Commercial Sites School Security Doors Sectional Doors Secured by Design explained: is it mandatory for doors? Secured by Design vs NPSA vs LPCB: Which One You Need Security Door Locks Security Door Maintenance Checklist Security Doors and Access for Everyone: What Approved Document M Asks Security Doors for A and E Departments Security Doors for Badminton Clubs Security Doors for Bowling Alleys Security Doors for Bowls Clubs Security Doors for Climbing Centres Security Doors for Cricket Clubs Security Doors for Dialysis Centres Security Doors for Golf Clubs Security Doors for Hockey Clubs Security Doors for Ice Rinks Security Doors for Maternity Units Security Doors for Mental Health Units Security Doors for Oncology Units Security Doors for Operating Theatres Security Doors for Rehabilitation Centres Security Doors for Snooker Clubs Security Doors for Squash Clubs Security Doors for Swimming Pools Security Doors for Tennis Clubs Security Doors West Midlands Explained Security Fencing Security Gates Cost Factors Explained Security shutters vs high performance roller doors Security shutters vs retractable grilles: which suits retail and commercial openings? Security Turnstiles Explained Security Window Film Security Windows for Schools Explained Self Storage Security Doors Server Room Doors Explained Shopping Centre Security Doors Smoke Control Doors Explained Smoke Curtains Specification Mistakes When Mixing LPS 1175, PAS 24 and SBD in One Tender SR2 vs SR3 vs SR4 security doors: choosing the right LPS 1175 level Stadium Security Doors Steel Door Frames Steel vs aluminium security doors: strength, ratings and looks Steel vs timber fire doors: which suits your building? Student Accommodation Security Doors Substation doors: security, ventilation and specification Supermarket Security Doors Telescopic Bollards Tender Evaluation Criteria and Scoring for Security Doors and HVM The Scope of a Maintenance Contract for Security Doors and Barriers Theatre Security Doors Thermal and Weather Performance of External Security Doorsets Thermally broken steel security doors: U-values and certification Traffic Calming as Hostile Vehicle Mitigation Transport hub security requirements Turnstile Cost Factors Explained Turnstile vs speed gate vs security portal: choosing entrance control Types of security doors for commercial buildings University Security Doors Explained Vehicle Dynamics Assessment: What It Tells the Buyer Before a Barrier Is Specified Warehouse Security Doors Explained Warehouse Security Gates Warranty, Defects Liability and Guarantees for Security Doors and Barriers What affects the cost of a bullet resistant door What affects the cost of a high-security door in the UK Window Security Bars View all →