A walk-in centre takes patients with no appointment, so each leaf takes the LPS 1175 grade its room demands, B3 at the entrance and D10 at the drugs store.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A walk-in centre takes patients through the day with no appointment, so the waiting room fills with people who arrived unannounced and the treatment rooms turn over from one patient to the next. The entrance takes the arrivals in, reception takes their names, the waiting room holds them till their turn comes, the treatment rooms hold the examination and the care, the drugs store holds the medicines, the staff office holds the records and the plant room keeps the lights and the air moving.
LPS 1175 Issue 8.2, dated September 2024, grades a leaf by the minutes it stands against the tools the test names. Three minutes is the hold of a B3 leaf, five minutes the hold of a C5 leaf and ten minutes the hold of a D10 leaf, and drawings drawn before the rename may still call the same three leaves SR2, SR3 and SR4, so the order carries both names beside each leaf.
A walk-in centre is not a GP surgery, because no patient books a time and no consultation is planned in advance, and it is not a hospital, because no one stays overnight and no ward sits behind the doors, and it is not a pharmacy, because the rooms behind the front hold treatment rather than a counter. The security doors for GP surgeries guide grades the doors of a building that books its patients in, and the security doors for pharmacies guide grades the doors round a counter and a dispensary.
- B3 / C5 / D10Grades to LPS 1175 Issue 8.2
- Drugs storeWhere D10 sits in the centre
- No appointmentPatients arrive through the day
- One listEvery centre leaf named
Seven rooms in a walk-in centre: the grade each leaf takes
Seven rooms make up a walk-in centre, and the grade follows what each room holds. The seven rooms are the entrance, reception, the waiting room, the treatment rooms, the drugs store, the staff office and the plant room, and the grade on each leaf follows what sits behind it.
B3 sits on the entrance, reception and the waiting room, because all three stand where patients and staff can see them through the day. C5 goes on the treatment rooms, the staff office and the plant room, because the care, the records and the plant behind those leaves ask for a longer hold than the public rooms. The drugs store takes D10, because the medicines behind it are the most portable value in the building.
Every opening is named on its own line of the order, with the leaf, the grade and the minutes written beside it, so the fitter checks each leaf against its line before hanging it.
| Room | Grade | Minutes | What to check |
|---|---|---|---|
| Entrance | B3 | 3 | Leaf, lock, closer |
| Reception | B3 | 3 | Leaf, lock, reader |
| Waiting room | B3 | 3 | Leaf, lock, closer |
| Treatment rooms | C5 | 5 | Leaf, lock, seals |
| Drugs store | D10 | 10 | Leaf, lock, hinges |
| Staff office | C5 | 5 | Leaf, lock, reader |
| Plant room | C5 | 5 | Leaf, lock, seals |
One leaf in the centre can carry the fire proof and the forced entry proof together, so a single report holds both. The fire minutes run from 30 to 120 under EN 1634-1, and the letter after the number says what stayed back, E for flame on its own, EW for flame with some of the heat, EI for flame with the heat as well. The fire and security doors dual certification guide shows the pair proved on the same leaf, and the SR2 vs SR3 vs SR4 guide puts the old names beside the new grades.
The entrance, reception and waiting room: B3 where patients arrive
Patients arrive at the entrance with no booking, so the leaf between the street and reception stays shut and locked between each arrival. The leaf must open fast to a card or a key in staff hands, and it must shut fully behind them.
The entrance asks for three minutes because it stands in sight of the staff at reception. A reader on the street side opens the leaf to staff cards, and a key override stands behind the reader for the day the reader fails. The access control doors guide covers readers and locks on a centre leaf, and the door entry systems guide covers the panel that lets staff through from the street.
A patient pushing the entrance leaf meets a limit set by BS 8300 and Approved Document M, under 30 N across the first 30 degrees of swing and under 22.5 N after that, so the leaf opens for a person leaning on a stick or carrying a child. The closer that shuts the leaf carries a proof to BS EN 1154, and EN 1 stands as the smallest power size the standard names.
No patient waits at a shut entrance
The entrance door opens for every arrival through the clinic day, because the walk-in centre takes patients who arrive without appointments. A patient walks in from the street, the door opens to them, and the door shuts behind them, so the front stays shut to the street while the waiting room fills inside.
The reader at the street side answers a staff card and keeps the door shut to every other card, so staff pass through while patients come in through the same door at the front. A spare key stands behind the reader for the day it stops working, and the key is kept where the clinician in charge can reach it at once. The reader is tried each morning before the first patient arrives.
The doors on the way out carry a bar proved to BS EN 1125 on every route that serves more than 60 people, with the bar spanning at least three fifths of the door width, so a crowd pressing on it gets the door open at once. The panic hardware guide names the bar that throws the door open when the waiting room empties at once.
| Point in the day | Door state | Who moves it |
|---|---|---|
| First arrival | Opened, then drawn shut | Patient at the front |
| Midday queue | Shut after each arrival | Reception staff |
| Last patient | Shut, latch caught | Clinician closing the centre |
Bollards guard the frontage where the queue stood, set with gaps of no more than 1,200 mm between them and each post at least 500 mm high, as ProtectUK sets it. The choosing HVM bollards guide shows where the posts stand along the frontage.
The reader answers a card for every member of staff
The list beside the reader names each card holder, so a new member of staff joins it on their first day and a lost card comes off it the day it is reported. The door entry systems guide covers the panels a centre fits at its front.
Once a month the clinician in charge goes round the centre with the door list, working each door in turn, and a door that will not shut or a lock that will not turn goes on the list beside its own room that same day. What that walk should cover is set out in the security door maintenance checklist guide.
The round reaches each door with the same checks, from the seal to the gap, and the fire door inspection checklist runs through the checks for each door as the round reaches it.
The entrance door is opened for every arrival and shut behind each one, and the door that takes that duty all day must still sit true in its frame at the end of it. A door that drags on its hinges or a bolt that misses its keep goes on the list the same day it turns up.
The centre sends its rooms to the healthcare doors quote as the day runs, entrance first and drugs store last, with the grade beside each one.
Treatment rooms: C5 on the leaf that shuts while a patient is treated
A treatment room holds a patient mid-treatment, so its leaf takes C5 and stays shut while the clinician works inside. The lock on the room side lets the clinician open it at once when the treatment ends.
The leaf hangs on hinges proved to BS EN 1935, grade 13 proved through 200,000 cycles under a leaf of 120 kg and grade 14 proved through the same cycles under a leaf of 160 kg, so the leaf stays square in its frame and the bolt keeps meeting its keep.
A panel set high in the leaf lets staff see whether the room is in use without opening it, and the panel goes through the test with the leaf, so the report names the glass and its fixings beside the leaf. The hospital security doors guide grades the doors of a building where patients stay overnight.
The drugs store: D10 behind the medicines
The drugs store holds the medicines, so its leaf takes D10, the longest hold LPS 1175 Issue 8.2 names. The leaf, the frame, the fixings and the lock were tested as one doorset, and the report gives ten minutes against the tools the test names, because the medicines counted inside are the easiest value in the building to carry out. No published table lines LPS 1175 grades up against ASTM ratings, so the order carries the LPS grade alone and no other rating beside it.
The drugs store leaf carries no glass, because a pane would let the corridor see the medicines and would put a hand close to the lock. The leaf stays shut whenever no one is working inside.
TS 007 counts a 1 star cylinder with a 2 star handle as a 3 star set, so the pair is ordered together and neither half is bought alone. The security door locks guide names what the lock on the drugs store must do, and the keys to the room are held by named staff only.
Staff office and plant room: C5 on the rooms behind the front desk
The staff office holds the patient records and the papers that run the centre, so C5 sits on its leaf and the leaf stays locked when the room is empty, because an open office would hand a passer by the records and the keys to the rooms behind it.
The plant room holds the boards and the equipment that keep the lights, the heating and the air moving, so its leaf takes C5 as well. The plant room door requirements guide names in full what a leaf on that room must do.
Staff move between the office and reception through the day, so the leaf between the two rooms needs to shut by itself after every pass. The closer on it is proved to BS EN 1154, and a fire leaf takes no power size below EN 3.
Locks, readers and keys: who opens which leaf through the day
Each leaf behind reception opens to the cards and keys of the staff who work there, and a card held on the public side opens none of them. A key plan that gives each holder the rooms their work needs, and no room beyond those, is set out in the master key systems guide.
The clinician in charge holds a key that opens every leaf behind reception, and the reception staff hold keys that open only the rooms their shifts take them to. How the order runs from the first leaf to the last is set out in the 10 steps to specify an LPS 1175 door guide. A lost card is taken off the reader list the day it is reported, so a card found on the waiting room floor opens nothing.
Bollards and the waiting room at the end of the day
The waiting room can still hold a full room of people at once, so the leaves on the way out must let them move fast while a vehicle stays off the frontage. A push bar proved to BS EN 1125 runs across the leaves on the way out wherever the route serves more than 60 people, and the bar covers no less than 60 percent of the leaf width, so one push from a person in a crowd throws the leaf open. The panic hardware guide names what the bar must do when a crowd pushes against the leaf.
Royal Assent came for Martyn’s Law in April 2025 and the start is expected in spring 2027, with the lower tier covering premises that may hold 200 to 799 people and the higher tier covering 800 or more. A centre whose waiting room may hold that many people falls inside those tiers. What each tier asks of the building is named in the Martyn’s Law guide for premises.
A vehicle is kept off the frontage by bollards, and ProtectUK sets the clear gap between them at 1,200 mm at most, with each bollard standing at least 500 mm high. The choosing HVM bollards guide covers how the frontage is laid out.
One last walk round locks every leaf in turn
When the last patient leaves, the waiting room empties, and the leaves are shut and locked in turn, starting with the treatment rooms and ending with the drugs store leaf, which is checked last before the doors are locked for the night. The last person out walks the rooms in the same order every evening, so no leaf is left to chance and no room is skipped because the day ran late. The clinician in charge holds the list for that walk, and each leaf is tried with its own key before the building is left for the night.
The leaves on the way out carry a bar proved to BS EN 1125 on every route that serves more than 60 people, with the bar spanning at least three fifths of the leaf width, so a crowd pressing on it gets the leaf open at once. The guide to panic hardware names the bar that throws the leaf open when the waiting room empties at once.
| Time | Leaf | Check |
|---|---|---|
| End of day | Treatment rooms | Shut and locked |
| End of day | Drugs store | Tried last, lock turned |
| Night | Entrance | Locked from inside |
Where the queue stood through the day, bollards stand through the night, with no more than 1,200 mm of clear gap between them and each one standing at least 500 mm high, as ProtectUK sets it. The guide to choosing HVM bollards shows where the posts stand along the frontage.
Staff open the entrance leaf with a card at the street side reader, and a spare key stands behind the reader for the day it stops working. The guide to door entry systems covers the panels a centre fits at its front.
The leaf on the drugs store gets its try after every other leaf, because it guards the medicines and it must stand shut before the building empties. It is tried with its key, watched as the closer draws it home, and locked with a turn of the key, and a fault found on that last round is written down the same evening, so the leaf is put right before the next morning.
The bollards stand where the queue stood so that no vehicle reaches the frontage
Once a month the clinician in charge goes round the centre with the door list, working each leaf in turn, and a leaf that will not shut or a lock that will not turn goes on the list beside its own door that same day. A leaf that drags on its hinges or a bolt that misses its keep goes on the list beside its own door that same day. What that walk should cover is named in the security door maintenance checklist guide.
The round reaches each leaf with the same checks, from the seal to the gap, and the fire door inspection checklist runs through the checks for each leaf as the round reaches it.
The centre order is drawn up room by room, and the healthcare doors quote page covers the waiting room, the treatment rooms and the drugs store one by one, so the leaves and the bollards are priced together.
The walk-in centre order: every leaf, its grade and its lock
The whole order sits on one list, with a line for every opening that names the leaf, the grade, the lock and the closer beside it. A leaf with no line of its own may end up hung where it does not belong, and a C5 leaf on the drugs store would hold for five minutes where the medicines ask for ten.
The clinician in charge takes the door list round the centre each month and tries the leaves in turn. A leaf that drags, a bolt that misses its keep or a reader that stays silent is written beside its own door the day it is found, and the security door maintenance checklist names what the walk should cover.
The order is read leaf by leaf before anyone signs it, because a closer that turns up after the doorset holds the whole job up. What the order must hold for every door is set out in the how to specify security doors guide, and the steel door frames guide names how the frame holds the leaf and the lock together.
The grade on a walk-in centre leaf follows the room behind it, so the leaf, the lock and the reader are ordered together and checked together against the medicines and the patients behind the leaf.
What grade does a walk-in centre entrance take?
B3 to LPS 1175 Issue 8.2, which holds for three minutes, because the entrance stands in view of the staff at reception through the day.
What grade does a drugs store take?
D10 to LPS 1175 Issue 8.2, which holds for ten minutes, because the medicines sit behind a leaf that is shut and locked whenever no one is working inside.
What grade does a treatment room leaf take?
C5 to LPS 1175 Issue 8.2, which holds for five minutes, because the room holds a patient mid-treatment behind a shut leaf.
Can one leaf hold fire and forced entry?
Yes, where one leaf went through the fire test and the forced entry test, so a single report names the period and the grade together.
Who checks the walk-in centre doors?
The clinician in charge walks the centre with the door list each month and tries the leaves in turn, so a fault is found and put right.