The accountable person is the person the Building Safety Act 2022 holds responsible for managing building safety risks in a higher-risk building, and fire doors are one of the risks that person must assess, manage and prove.
- Section 72Who counts as an accountable person
- Section 77Occupying an unregistered building is an offence
- 28 daysTo apply for a building assessment certificate when told to
- Safety case reportPrepared by the principal accountable person
Who counts as an accountable person
Under section 72 of the Building Safety Act 2022, an accountable person for a higher-risk building is a person who holds a legal estate in possession in any part of the common parts, or who is under a relevant repairing obligation for any part of the common parts. A relevant repairing obligation is a duty under a lease or an enactment to repair or maintain that part, and where the building is on commonhold land, the commonhold association is the accountable person.
Common parts mean the structure and exterior of the building, except a part demised to a single dwelling or business premises, and any part provided for the use of the residents of more than one residential unit. Flat entrance doors, stair doors, lobby doors and corridor doors are common parts in that sense, and the person who owns or must repair them is the accountable person for them. A housing provider that owns the freehold of a block is usually the accountable person for its common parts.
The principal accountable person
Where a building has more than one accountable person, section 73 names one of them the principal accountable person: the one who holds a legal estate in the relevant parts of the structure and exterior, or the repairing obligation for them. Where there is only one accountable person, that person is the principal accountable person, who carries the duties that belong to the whole building.
The principal accountable person prepares the safety case report for the building, registers the building, and applies for the building assessment certificate when told to. Each accountable person must assess and manage the building safety risks in their own parts, and share information with the other accountable persons. A door on a stair that two accountable persons share needs one record, not two competing ones.
| Duty | Accountable person | Principal accountable person |
|---|---|---|
| Assess and manage building safety risks | Yes, for their parts | Yes, and holds the whole-building view |
| Keep golden thread information | Yes | Yes, and sets the policies |
| Register the building | No | Yes, before occupation |
| Prepare the safety case report | Contributes assessments | Yes, prepares and holds it |
| Mandatory occurrence reporting | Must report occurrences | Yes, and runs the system |
| Building assessment certificate | No | Yes, applies within 28 days |
Our fire door remediation programme guide sets out how a housing provider works through a stock of doors, finding by finding.
Register the building before anyone lives there
A higher-risk building is a building in England that is at least 18 metres high or has at least 7 storeys, and contains at least 2 residential units. The principal accountable person commits an offence if the building is occupied but not registered, and a relevant accountable person commits an offence if a residential unit is occupied before a completion certificate for the relevant part has been issued.
The registration number begins with HRB. The safety case report should carry it with the building’s name, address, build date, height and number of storeys. A building that was already occupied when the regime began had to be registered by 1 October 2023. Our flat entrance doors guide covers the FD30S door, its closer and its seals.
Registration is not paperwork for its own sake. It is the regulator’s record that a named person has taken responsibility for the building’s fire doors.
Assess the building safety risks, including fire spread
Every accountable person must assess the building safety risks for the parts they are responsible for, and take all reasonable steps to prevent a building safety risk materialising and to reduce the severity of any incident that occurs. Building safety risks are the spread of fire or smoke, and structural failure.
For fire doors, the assessment starts with the fire risk assessment already carried out under the Fire Safety Order. The accountable person should know the standards the building was built to, or have inferred them from the build date, height and type, and should describe the compartmentation: fire resistance between floors, between flats, above false ceilings, and around penetrations such as pipes and cables. Where the assessment finds a door that no longer holds fire back, the accountable person must act on it. Our fire door maintenance guide covers the checks that keep the rating honest over the years.
The safety case report: where fire doors appear
The principal accountable person should prepare the safety case report as soon as possible when the building is already occupied or becomes occupied, or when they become the principal accountable person. The report sets out the building safety risks and how they are being managed, and it must be sent to the regulator when the regulator tells the principal accountable person to apply for a building assessment certificate, or at any time the regulator asks for it.
Fire doors have their own section in the government’s guidance for the safety case report. It should show that fire doors are in place in necessary locations, such as entrance doors to flats, stairs and lobbies, and provide evidence that fire doors and door closers are regularly inspected. Where a fire door survey has been carried out, the report should include the surveyor’s competence, the significant findings, and the accountable person’s response. Our commercial buildings regulations guide sets out the wider duties that sit beside the accountable person’s own.
Mandatory occurrence reporting and the residents engagement strategy
The principal accountable person must establish and operate a mandatory occurrence reporting system. The system must let people report and record occurrences, assess them promptly, and tell the regulator as soon as possible where required. An occurrence that manages a risk of fire spread or structural failure and likely prevented death or serious injury to a significant number of people must be reported.
The principal accountable person must also prepare and review a residents engagement strategy, and act in accordance with it, promoting the participation of residents and the owners of residential units in building safety decisions. For fire doors, that means residents who understand why their flat entrance door must be kept shut, why the closer must not be tampered with, and why damage must be reported at once. The Fire Safety (England) Regulations 2022 already ask the responsible person to give residents that information. Our fire door inspection checklist lists the points to check on a single door.
The building assessment certificate, and displaying it
When the regulator directs the principal accountable person to apply, the application for a building assessment certificate must be made within 28 days, accompanied by the most recent safety case report, information about the mandatory occurrence reporting system, information showing compliance with the duty to provide information, and the residents engagement strategy. The regulator must assess whether the relevant duties are being complied with.
If satisfied that all relevant duties are being complied with, the regulator must give the certificate. If not, it must refuse and tell the principal accountable person why. Once issued, the principal accountable person must ensure that the most recent certificate is displayed together with a notice about the accountable persons. The regulator aims to reassess a building’s certificate every 5 years. Our fire door certification guide covers the certificate and test evidence a doorset should show.
Am I the accountable person or the responsible person?
They are different roles under different laws. The accountable person is named by the Building Safety Act 2022 for a higher-risk building. The responsible person is named by the Fire Safety Order 2005 for the premises, and is usually the owner or the person with control.
What if there is more than one accountable person?
Each accountable person carries the duties for their own parts, and one of them is named the principal accountable person under section 73. The principal accountable person is the one who prepares the safety case report and registers the building.
How often must the safety case report be reviewed?
The guidance says to prepare it as soon as possible when the building becomes occupied or when you become the principal accountable person. The report should carry a date or version number so the latest version can be identified.
What must the safety case report say about fire doors?
It should show fire doors in place where they are needed: entrance doors to flats, stairs and lobbies. If a survey of the fire doors has been done, it should record who did it, what they found, and how the accountable person responded.
What happens if the building is not registered?
Occupying the building before it is registered is an offence for the principal accountable person.