Fire Door Rules for Petrol Stations

A petrol station holds fuel, cash and stock behind its kiosk counter, so each fire door takes its period from the room behind it and the way out.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed across the UK
Prefer to talk?+44 7352 267239

Get a free project quote

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

A petrol station is a shop, a store and a fuel site under one roof, and the fire doors must hold the fire where it starts while drivers and staff reach the way out. The leaf holds fire back for its period, and it opens for people who have never walked the route, so each door takes the period the room behind it demands.

The period on a forecourt door follows the room behind the leaf, because the kiosk, the stores and the back office ask different things of the doors that guard them. The order carries the period beside each opening, so the leaf that arrives is the leaf the room needs.

The rules for the shared parts of a shop are set out in the fire door regulations retail guide, and the rules for the stores beside the kiosk are set out in the fire door regulations warehouses guide. The forecourt order names every door in the building, with the period and the hardware beside each one.

  • FD30 / FD60Fire periods to EN 1634-1
  • E / EW / EI 30-120What the letters beside the period mean
  • 4 mmThe gap round the leaf
  • One listEvery forecourt door named

Kiosk, stores and back offices: one forecourt, three parts

A petrol station is three buildings in one: the kiosk where the drivers pay, the stores where the goods wait, and the back office where the records sit. The rules follow those parts, because a door between one part and the next must hold the fire where it started while the drivers reach the way out.

The kiosk takes the doors that let a driver in and out, and each leaf must open for people who have never seen the building before. The stores take the doors that guard the goods, and each leaf must hold fire back where the stock sits. The route that joins them takes the doors the staff pass through, and each leaf takes the period the escape needs.

The forecourt writes its fire strategy first, naming every opening with the door beside it, and the order follows the strategy, so no leaf is ordered without the room it guards behind it.

FD30 and FD60 on a forecourt: the periods each room takes

Each part of a forecourt asks a different period of its doors, because the load behind each leaf is different. The kiosk holds the drivers and the goods on the shelves, the stores hold the goods in boxes and crates, and the back office holds the records, so the period on each door follows the room, not the leaf.

EN 1634-1 is the test behind every fire door, and its result is written as minutes with letters beside them. Thirty minutes is the shortest proof on the scale and 120 the longest, while the letters say what the leaf held back: flames alone, flames with some heat, or flames with the heat as well. Minutes without letters say only half of what the door proved, so the order names both together.

A leaf that must hold for longer weighs more, and the frame that carries it runs deeper, so the figure on the quotation rises with the weight. Where an opening needs 60 minutes, a leaf proved for 30 has no place in it, because the shorter leaf is the one that gives way first.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

The kiosk: glass, tills and the doors between the counter and the stock

The kiosk is mostly glass, and the doors on it must hold their proof while letting drivers see the tills beyond them. A glazed leaf lets a driver see the counter without opening the leaf, and the pane takes the same proof as the leaf, because the leaf and the glass are proved as one doorset. The bead and the fixings the test report names are written on the order beside the glass.

The goods on the kiosk shelves carry a fire load of their own, and the doors between the kiosk and the stores must hold the fire where it starts. A leaf between the kiosk and the stores takes the period the stores demand, because the fire that starts among the goods must stay among the goods while the drivers move out.

Windows on the same wall are covered in the fire rated windows guide, and the fire rated glass cost guide sets out what the glass itself costs.

Stores and the fuel controls: the doors behind the counter

The stores take the heaviest fire load on the forecourt, because the goods sit there in boxes and crates all day. A store leaf takes FD60 where the load is heaviest, and the period follows the fire load, not the size of the kiosk.

The fuel controls sit behind their own door, because the pumps and the tanks are shut down from the kiosk. A leaf that guards the fuel controls takes FD60, and it shuts after every person who passes, because a leaf left open lets smoke reach the route before the drivers do.

The stores take doors that stand open through the day, so the staff can move goods without stopping at every leaf. A leaf that must stand open takes a hold-open device proved to BS EN 1155, so the leaf shuts on its own the moment the alarm sounds. A leaf wedged open with a crate holds nothing back when the fire comes, and the wedge belongs in the store, not under the leaf.

The back office and the plant room: the doors that guard the records and the services

The back office holds the records and the takings, and the leaf that guards it takes the period the room beside it takes. A back office leaf takes FD30 where the office sits beside the kiosk, because the fire that starts among the shelves must not reach the records.

The plant room takes the same care, because the electrical boards and the refrigeration plant sit behind its doors all day. A plant room leaf takes FD60, and the gap round it is kept to 4 mm, with the seal checked with the leaf shut.

The kiosk and the stores need a leaf that holds fire and holds an intruder out, so some forecourt leaves carry both proofs at once. What the leaf must hold decides the category: B3 for three minutes, C5 for five and D10 for ten, under Issue 8.2, dated September 2024. The LPS 1175 vs PAS 24 guide shows the two ratings beside each other, and the keeping an LPS 1175 rating valid guide names what can break a rating once a door is fitted. How one doorset carries both proofs is covered in the fire and security doors dual certification guide.

When a back office door stands shut for weeks, the seal tells first

A back office door on a forecourt can stand shut for weeks at a time, because the records inside are fetched only now and then. The plant room door beside it waits the same way, opened only when a contractor calls to service the pumps. A door that waits that long does not stay as it was hung, and the fault shows first where the seal meets the frame, because a strip that has sat pressed against one spot takes the shape of that spot and then sticks when the door is finally pulled.

Heat is what the seal is made for, and the strip stays ready through the quiet weeks. The strip swells once heat passes 200 degrees, and it closes the opening beside the door before the temperature reaches 250. A coat of paint holds the strip down, and a strip out of its groove opens the same gap to flame, so the monthly try must look at the strip as well as the swing. The seals guide gives the heat at which the strip starts to swell and the heat at which it closes the opening.

Hinges stiffen where they sit still, and a lock seizes where its bolt has not moved for a month. The opening left beside a hung door is four millimetres, enough for the door to swing clear and tight enough for the seal to close it, and a hinge that has stiffened lets the door drop until it scrapes the threshold. EN 3 is the lowest closer size BS EN 1154 allows on a fire door, and the back office door is given a size above that mark. The closer guide works through the sizes a forecourt door takes.

Part What weeks of stillness do Monthly try
Seal Sticks to the frame in one spot Strip seated, unpainted, unbroken
Hinge Stiffens and lets the door drop Door swings free without dragging
Lock Bolt seizes in the keep Key turns and bolt throws cleanly
Closer Loses pull and stops short Door meets the frame on its own

Which part fails first on a door that nobody opens for a month?

The answer is found by trying the door, not by looking at it from the corridor. Each back office and plant room door is pulled wide once a month and left to find its frame, and a door that stops short gets a note beside its room that same day. The hardware guide names the fittings proved with the door, and the gap guide gives the figure the gauge must show against the door.

A door that will not open on the day it is needed holds the records behind it and the plant behind it alike, and a door that will not shut opens the office to vapour from the pumps. The walk that tries them is short, one turn round the back of the building in daylight. The inspection checklist gives the monthly walk its order, room after room, so a quiet month skips none of them.

The back office list goes to the enquiry checklist with the seal, the hinges and the lock written beside the door, so the room that waits weeks still opens on the day it must.

Escape routes on a forecourt: the way out for drivers and staff

The drivers and staff on a forecourt follow the route the building gives them, and the way out must be clear when the alarm sounds. Each door on the route opens with one push from anyone who reaches it, because the leaf must open whether the power is there or not.

The smoke proof on a route door comes from BS EN 1634-3, with Sa for smoke at room temperature and S200 for smoke at 200 degrees. Smoke moves faster than flame, so it reaches the route ahead of the fire, and a seal holds only where it meets the frame all round. How the doors hold smoke back while people move past them is covered in the smoke control doors guide.

The route takes one period on every leaf it passes, because the leaf with the shortest proof decides how long the route stands. No leaf on the route takes a shorter proof than the leaves beside it, and the leaf that fails first is the leaf the route cannot spare. The doors that guard a warehouse are covered in the warehouse security doors guide, and a forecourt takes the same care with its stores as a warehouse takes with its own.

Position Door Period What to check
Kiosk Glazed leaf FD30 Leaf, glass, closer
Stores Steel leaf FD60 Leaf, lock, seals
Back office Fire leaf FD30 Leaf, lock, closer
Plant room Fire leaf FD60 Leaf, seals, gap
Public route Fire leaf FD30 Leaf, bar, closer

The moving parts: closers, seals and the gap on a forecourt leaf

A kiosk leaf opens and shuts all day, so its closer works harder than any other closer on the site. BS EN 1154 sets the smallest power for a fire door closer at EN 3, and the test is to open the leaf and watch it shut on its own. Where the closer has lost its pull the leaf stands open after the driver has passed, and an open leaf holds nothing back.

The leaf is hung with a 4 mm gap beside it, so it swings free and the seal meets the frame all round when the leaf shuts. As the heat climbs towards 200 to 250 degrees the intumescent seal swells and closes the gap the leaf leaves, unless paint over the seal holds it down. When a seal slips from its groove it is noted against its door that same day, with the part and the date beside it.

Each hinge takes its share of the leaf through every opening of the day, and a loose hinge lets the leaf sink month by month until it drags and smoke slips through the gap at the top. What the lock the key turns must do is set out in the fire door hardware guide, and the fire door closers guide covers sizes and fitting.

Which closer pulls a forecourt leaf shut against the wind?

A forecourt never shelters its kiosk leaf. The wind runs straight off the pumps and catches the leaf on every opening, so the closer earns its keep in gusts rather than in calm air. Drivers push through a hundred times a day, and the leaf has to find its frame again after each of them without a hand to help it. BS EN 1154 puts EN 3 as the lowest closer size a fire leaf may take, and a leaf that faces the forecourt wind is given a size above that lowest mark, because a closer at the minimum is the first to lose the fight on a blustery day.

Vapour from the pumps sits low and drifts towards the kiosk, so the strip round the leaf has to touch the frame without a break. Heat does the work: past 200 degrees the intumescent strip swells, and before the temperature reaches 250 it has grown across the opening the leaf leaves. Paint laid over the strip holds it down, and a strip that has worked free of its groove leaves the same opening bare. The seals guide names the temperatures at which the strip starts to grow and the point where it closes the opening.

Four millimetres is the opening left beside a hung leaf, enough for the leaf to swing clear in a gust and narrow enough for the seal to close it. Hinges take the weight of that leaf through a hundred openings a day, and one that loosens lets the leaf drop until it scrapes the threshold and the wind pins it open. Closer sizes for a leaf that faces the wind are listed in the closer guide, and the fittings tested with the leaf are named in the hardware guide.

Part What the wind does Check
Closer Pushes the leaf back open Leaf meets the frame on its own
Seal Dries and shrinks in the draught Strip seated, unpainted, unbroken
Gap Widens as the leaf sinks Even round the leaf at 4 mm
Hinge Works loose under daily use Leaf swings free without dragging

The seal and the gap earn their check at the end of the day

At the end of trading the leaves are worked in turn, kiosk first and back office last. Each leaf is pushed wide and left to find its frame, and one that stops short is written down beside its door that same night, closer and date alongside, so the mending is booked before the morning drivers arrive. The gap guide names the figure to look for when the gauge goes against the leaf.

A leaf that stays open overnight leaves the kiosk open to vapour and to the wind, and the route beside it loses its guard before the first driver of the morning. After a storm the leaves are tried again, because a gust that throws a leaf back can bend a hinge or shake a fixing loose. The inspection checklist gives the night walk its order, leaf after leaf, so a tired evening skips none of them.

The forecourt order puts the closer, the seal and the opening beside each leaf, and the order goes to the security door enquiry checklist, where each leaf is listed with its period and its closer.

The forecourt order: every door on one list

The forecourt order is written as one list, and each line names a door, its leaf, its period, its lock and its closer, so the door that arrives is the door the room needs. A single leaf named for the whole forecourt leaves the fitter to guess which room takes which period, and a leaf in the wrong room guards the wrong thing.

Before the order goes out the quotation is checked figure by figure against the list, each one sitting beside the door it belongs to, so a figure left off still has to be paid and a part added after the order costs more than the same part ordered with the building. The how to specify security doors guide names the columns the list must hold, and the security door cost factors guide works through what a higher grade adds to the price.

Before the kiosk opens each morning the staff try the leaves in turn, from the kiosk through the stores to the back office. A leaf that drags, a seal that has slipped from its groove, or a closer that has lost its pull is noted against its door on the day it is found, and the repair is booked while the fault is still small. The record stays with the forecourt file, and what the visit should cover is set out in the fire door inspection checklist.

A forecourt leaf holds only as long as the fuel behind it and the route beside it, so the period, the release and the closer must all sit on the same list.

What period should a petrol station door carry?

FD30 or FD60 to EN 1634-1. The letters beside the minutes say what the doorset held back, and the room behind the leaf decides which period the door takes.

Can one leaf hold fire and forced entry?

Yes, when one doorset was tested for fire and for forced entry together, so the one report covers both jobs.

Do petrol station doors need panic hardware?

Yes, the leaf on the way out takes a panic bar proved to BS EN 1125, across at least 60 percent of the leaf, so one push throws the latch for the drivers behind it.

What grade should a store door carry?

The grade follows the room: B3, C5 or D10 to LPS 1175, with the stores taking a higher category than the kiosk.

Who checks the petrol station doors?

The forecourt manager walks the round that covers every door, and each visit is written into the record the forecourt keeps.

Specifying doors for a petrol station?Send the door list and the period each door must hold for a tested door quotation.
Get a free quote

Related

More in guides for specifiers

10 mistakes when specifying certified security doors 10 steps to specify an LPS 1175 door Acceptance and Snagging of a Security Door or Barrier Job Access Control Doors Acoustic Doors: Ratings and Specification After a Forced Entry Attempt: Checking a Security Door Airport Security Doors Anti-Ligature Doors for Mental Health Wards Anti-Ram Bollards Anti-ram gates and barriers: protecting vehicle entrances Arcade Security Doors Explained Automatic Doors Automatic Gates Cost Factors Automatic Vehicle Barriers Ballistic Panels Bank Security Doors Bingo Hall Security Doors Explained Blast doors: glazed vs solid and how they are rated Blast protection window film: what it does and what it cannot do Blast resistant windows: what drives the cost and how to specify them Bollard Cost Factors Explained Bollard regulations in the UK: spacing, height and depth Bookmaker Security Doors Explained Builders Merchant Security Doors Bullet Resistant Glass Cost Factors Bullet resistant glass ratings explained: BR1 to BR7 and SG classes Bullet resistant vs bulletproof glass: what the difference means Buying Security Doors and HVM Through Public Frameworks Car Park Security Doors Explained Car Showroom Security Doors Casino Security Doors Explained CDM 2015 Duties When Security Doors, Shutters or HVM Are Installed Cinema Security Doors Cleanroom Doors Cold Store Doors College Security Doors Commissioning, Handover and the O&M Manual for Security Doors and HVM Communal entrance doors for flats: Secured by Design and what to specify Community Centre Security Doors Control Room Doors Court Security Doors Crash Rated Fences and HVM Fencing Explained Data centre physical security: doors, glazing, HVM and shielding by zone Dental Practice Security Doors Depot Security Doors Explained Door Entry Systems Due Diligence When Selecting Vehicle Security Barriers Emergency Exit Doors EMP Shielding Cost Factors Explained Exhibition Centre Fire Door Rules Exhibition Centre Security Doors Factory Security Doors Faraday cage vs RF shielded room: what a business needs FB4 vs FB6 vs FB7: how to choose a ballistic rating Fire and security doors: how dual certification works Fire Compartmentation Fire Curtains Fire Door Certification Fire Door Closers Explained Fire Door Cost Factors Fire Door Duties of the Accountable Person Fire Door Gaps Fire Door Hardware Explained Fire door inspection checklist for steel and timber doors Fire Door Maintenance Fire Door Regulations Care Homes Fire Door Regulations for A and E Departments Fire Door Regulations for Airports Explained Fire Door Regulations for Bowls Clubs Fire door regulations for commercial buildings in the UK Fire Door Regulations for Dialysis Centres Fire Door Regulations for Hockey Clubs Fire Door Regulations for Hospitals Explained Fire Door Regulations for Offices Explained Fire Door Regulations for Operating Theatres Fire Door Regulations for Retail Explained Fire Door Regulations for Schools Explained Fire Door Regulations for Snooker Clubs Fire Door Regulations for Stadiums Fire Door Regulations for Student Accommodation Fire Door Regulations for Warehouses Fire Door Regulations Leisure Centres Fire Door Regulations Restaurants Fire Door Remediation Programme for Housing Providers Fire Door Rules for Badminton Clubs Fire Door Rules for Bingo Halls Fire Door Rules for Bookmakers Fire Door Rules for Bowling Alleys Fire Door Rules for Car Parks Fire Door Rules for Car Showrooms Fire Door Rules for Cinemas Fire Door Rules for Climbing Centres Fire Door Rules for Colleges Fire Door Rules for Community Centres Fire Door Rules for Cricket Clubs Fire Door Rules for Dental Practices Fire Door Rules for Depots Explained Fire Door Rules for Golf Clubs Fire Door Rules for GP Surgeries Fire Door Rules for Gyms Explained Fire Door Rules for Ice Rinks Fire Door Rules for Maternity Units Fire Door Rules for Mental Health Units Fire Door Rules for Museums Fire Door Rules for Oncology Units Fire Door Rules for Opticians Fire Door Rules for Pawnbrokers Fire Door Rules for Pharmacies Fire Door Rules for Ports Fire Door Rules for Post Offices Fire Door Rules for Prisons Fire Door Rules for Rehabilitation Centres Fire Door Rules for Self Storage Fire Door Rules for Shopping Centres Fire Door Rules for Squash Clubs Fire Door Rules for Supermarkets Fire Door Rules for Swimming Pools Fire Door Rules for Tennis Clubs Fire Door Rules for Theatres Fire Door Rules for UK Arcades Fire Door Rules for UK Casinos Fire Door Rules for UK Hospices Fire Door Rules for Walk-in Centres Fire Door Signage Fire Door Vision Panels Fire Doors and Gateway 2 in Higher-Risk Buildings Fire Rated Glass Cost Explained Fire Rated Sliding Doors Explained Fire Rated Windows Cost Factors Fire Rated Windows Explained Fire Safety Enforcement Notices and Fire Doors: What the Responsible Person Must Do Flat Entrance Doors: PAS 24 and Fire Rated Forced Entry vs Ballistic vs Blast: Which Rating a Site Needs Garage Security Doors Explained Gate Automation Explained Golden Thread Records for Fire Doors GP Surgery Security Doors Explained Gym Security Doors Explained High Speed Doors HMO Fire Doors Hospice Security Doors Explained Hospital Security Doors: Wards, A&E, Plant Hospital Security Gates Hotel Fire Doors Hotel Security Doors How to choose HVM bollards: fixed, shallow mount, removable and automatic How to keep an LPS 1175 door rating valid after installation How to Specify Fire Doors in a Housing Tender How to specify security doors: a checklist for architects How to Verify a Secured by Design Listing How to Verify an LPS 1175 Certificate on Red Book Live How to Write an Operational Requirement for Physical Security HVM planters and street furniture: protection that blends in In-Service Care of Vehicle Security Barriers Installation Handover: LPS 1175 Doors and PAS 68 Barriers Intumescent Seals ISO 16933 explained: EXV and SB classes and hazard ratings ISO 22343 vehicle security barriers explained Keeping a Dual-Certified Fire and Security Door Valid in Service Laboratory Security Doors Layered Security for a Site: Deter, Detect, Delay, Mitigate, Respond Lead Times and Programme Risks for LPS 1175 Doors Leisure Centre Security Doors Library Security Doors Listed Building Fire Doors Loading Bay Doors Explained Lockdown and Access Control Hardware on an LPS 1175 Door LPS 1175 Gates and Grilles Explained LPS 1175 Issue 8 explained: from SR1 to SR8 to A1 to H20 LPS 1175 Roller Shutters LPS 1175 vs ASTM F2781 and Other US Ratings Explained LPS 1175 vs EN 1627: how UK and European burglar resistance ratings compare LPS 1175 vs PAS 24: which security standard does your door need? LPS 1175 Windows and Walling Explained Martyn’s Law and Places of Worship: What a Buyer Checks for Doors and Entry Control Martyn’s Law Enhanced Tier: Physical Measures and the Specifier Brief Martyn’s Law Standard Tier: Procedures, Doors and Shutters Martyn’s Law Timeline and the SIA Regulator Martyn’s Law: what premises must do and which physical measures to consider Master Key Systems MRI and RF shielded rooms: how they work and what to specify Museum Security Doors NPSA Catalogue of Security Equipment (CSE) Explained NPSA Forced Entry and Blast Guidance for Government Sites NPSA Guidance on Lockdown and Marauding Attack: What It Asks of Doors and Entrances Office Security Doors Optician Security Doors Explained Panic Hardware PAS 24 requirements for doors and windows explained PAS 68 Bollard Foundations Explained PAS 68 bollards: ratings, spacing and cost factors PAS 68 vs IWA 14 vs ISO 22343: hostile vehicle mitigation standards explained Pawnbroker Security Doors Explained Pedestrian Gates Petrol Station Security Doors Pharmacy Security Doors Planning Permission for Security Shutters, Gates and Bollards on Commercial Premises Plant room doors: fire, security and ventilation requirements Plant Room Fire Doors Port Security Doors Post Office Security Doors Explained Powder coating vs galvanising vs paint for steel Preliminary Market Engagement for Security Doors and HVM Prison Security Doors Programming a Security Door and Barrier Package on a Live Site Public-Sector Tender Response Checklist for Security Door and HVM Supply Reading a PAS 24 and SBD Door Test Report Regulation 38 Fire Safety Information at Handover for Fire-Rated Security Doorsets Replacing Security Doors in an Occupied Building Restaurant Security Doors Retail Security Doors Revolving Doors RF shielding standards and how shielded rooms are tested Rising Bollard Cost Factors Road Blocker Cost Factors Explained Road Blockers Explained Roller Shutter Cost Factors: What Drives the Price Roller shutter regulations in the UK: safety and maintenance Safe room and panic room doors: specification basics Safety Duties for Powered Doors, Gates and Barriers on Commercial Sites School Security Doors Sectional Doors Secured by Design explained: is it mandatory for doors? Secured by Design vs NPSA vs LPCB: Which One You Need Security Door Locks Security Door Maintenance Checklist Security Doors and Access for Everyone: What Approved Document M Asks Security Doors for A and E Departments Security Doors for Badminton Clubs Security Doors for Bowling Alleys Security Doors for Bowls Clubs Security Doors for Climbing Centres Security Doors for Cricket Clubs Security Doors for Dialysis Centres Security Doors for Golf Clubs Security Doors for Hockey Clubs Security Doors for Ice Rinks Security Doors for Maternity Units Security Doors for Mental Health Units Security Doors for Oncology Units Security Doors for Operating Theatres Security Doors for Rehabilitation Centres Security Doors for Snooker Clubs Security Doors for Squash Clubs Security Doors for Swimming Pools Security Doors for Tennis Clubs Security Doors for Walk-in Centres Security Doors West Midlands Explained Security Fencing Security Gates Cost Factors Explained Security shutters vs high performance roller doors Security shutters vs retractable grilles: which suits retail and commercial openings? Security Turnstiles Explained Security Window Film Security Windows for Schools Explained Self Storage Security Doors Server Room Doors Explained Shopping Centre Security Doors Smoke Control Doors Explained Smoke Curtains Specification Mistakes When Mixing LPS 1175, PAS 24 and SBD in One Tender SR2 vs SR3 vs SR4 security doors: choosing the right LPS 1175 level Stadium Security Doors Steel Door Frames Steel vs aluminium security doors: strength, ratings and looks Steel vs timber fire doors: which suits your building? Student Accommodation Security Doors Substation doors: security, ventilation and specification Supermarket Security Doors Telescopic Bollards Tender Evaluation Criteria and Scoring for Security Doors and HVM The Scope of a Maintenance Contract for Security Doors and Barriers Theatre Security Doors Thermal and Weather Performance of External Security Doorsets Thermally broken steel security doors: U-values and certification Traffic Calming as Hostile Vehicle Mitigation Transport hub security requirements Turnstile Cost Factors Explained Turnstile vs speed gate vs security portal: choosing entrance control Types of security doors for commercial buildings University Security Doors Explained Vehicle Dynamics Assessment: What It Tells the Buyer Before a Barrier Is Specified Warehouse Security Doors Explained Warehouse Security Gates Warranty, Defects Liability and Guarantees for Security Doors and Barriers What affects the cost of a bullet resistant door What affects the cost of a high-security door in the UK Window Security Bars View all →

Products

One supplier for the whole building envelope

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.