ArxBridge
Cold Store Doors
Cold store doors: insulated doors for chillers and freezers, with seals and thresholds that survive frost, hardware that works in the cold and one schedule.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A cold store door holds the cold in and the warm air out, and it does it every hour of every day. A chiller room that loses its cold through a door that does not shut costs power and spoils stock, and a freezer room that lets warm air in grows frost on the seals, so the door on a cold room matters as much as the refrigeration behind it.
The order starts with the room, not with the door. A chiller that holds food at a few degrees above freezing asks for a different door from a freezer that holds stock at minus 18 degrees, and a blast chiller that drops the temperature fast asks for a different seal from a store that holds one temperature all week.
The insulation, the seals, the hardware and the records all sit inside one schedule, and an order that names each one plainly gets the right doors on the right rooms. The rooms these doors guard are covered in our warehouse security doors guide, and the bays that feed them are covered in our loading bay doors guide.
- Insulated coreThe leaf that holds the cold in
- FD30 / FD60Fire resistance periods tested to EN 1634-1
- LPS 1175 B3 / C5 / D10Forced entry ratings, three, five and ten minutes
- 4 mmMaximum gap round a fire door leaf
Where a cold store door earns its keep: chillers, freezers and the rooms between
A chiller room holds food, drink or medicine a few degrees above freezing, and the door on it opens many times a day. Every opening lets warm air in, so the door must shut fast and seal tight, and the closer must pull the leaf shut against the draught from the corridor, because a chiller door left open is a room that warms while nobody watches.
A freezer room holds stock well below freezing, and the door on it faces a harder job. Warm air that reaches a freezer door turns to frost on the seal and ice on the threshold, so the seal must stay flexible in the cold and the threshold must stay clear, and the floor in front of the door must fall away from it so water runs off instead of freezing under the leaf. The rooms that hold the stock are covered in the warehouses and logistics sector page.
A blast chiller drops the temperature of food fast, and the door on it opens and shuts through the working day while the room behind it runs cold. The door must take that duty without the seals going hard or the hinges going stiff, and the shops that sell the stock are covered in the retail sector page.
Insulation and the thermal break: the leaf that holds the cold in
The leaf on a cold store door carries insulation in its core, and the thickness of that core follows the temperature the room must hold. A freezer leaf needs more insulation than a chiller leaf, so the core belongs on the schedule beside the temperature, and a leaf ordered without it cannot hold the room.
The thermal break stops the cold travelling through the metal from the inside face to the outside face. A door without a break carries the cold straight through the leaf, and the outside face drips with condensation, so the break belongs on the order beside the insulation. The leaves that carry one are covered in our thermally broken security doors guide.
The frame must carry the same insulation as the leaf, because a leaf that holds the cold in a frame that lets it out has failed half its job. The frame, the fixings and the seals belong on the same line as the leaf, so the door that arrives is the door that was proved.
Seals and thresholds: the parts that must survive frost
The seal round a cold store door must stay soft when the room behind it runs cold. A seal that goes hard in the cold leaves a gap round the leaf, and warm air through that gap turns to frost, so the seal material belongs on the order beside the temperature.
Some freezer doors carry a heated seal, with a low heat wire that keeps the seal free of frost. The heat wire needs power at the door, so the supply belongs on the order beside the seal, and the wire must be checked on the inspection round, because a wire that has failed leaves the seal to freeze to the frame.
The threshold must let trolleys and pallet trucks pass without a trip, and it must stay clear of ice. A threshold that holds water freezes the door to the floor, so the floor in front of the door must drain, and the parts that wear first are covered in our fire door hardware guide.
Frost on the threshold shows where warm air slips past the seal
A cold room tells on its door through frost. Warm air from the corridor slips past any gap in the seal, meets the cold of the room, and lays frost along the threshold and the frame. The frost is not a cleaning job; it is a map of the gap, and the thickest frost sits over the widest part of it.
Walk the room at the start of the shift and look at the threshold before the first trolley crosses it. Frost along one side only points at a seal that has gone hard on that side, while frost all round points at a doorset that no longer sits square in its frame. Either way the seal goes on the record the same morning, with the room named beside it, so the fault is traced to the door that caused it. The fire door inspection checklist gives the checks each round should make, and the maintenance checklist sets out the checks that keep the seals, hinges and release working through the shift.
Clear the frost before the shift, but do not mistake clearing it for fixing it. A threshold cleared each morning and frosted again by noon is a seal that needs changing, and the change is booked before the frost starts to lift the doorset off its seal. The sectional doors guide deals with the wide doorsets that serve the bays feeding the cold rooms.
Ice on the seal stops the room as surely as it stops the door
A seal that ices to the frame holds the doorset shut, and the room behind it stops. Staff cannot reach the stock, the shift waits at the threshold, and a hard pull on a frozen doorset tears the seal it was meant to protect. The heater wire is there to stop exactly that, warming the seal just enough to keep it free while the room stays cold.
Feel the seal at the start of the shift, before the room fills. A seal that is soft and free to move is doing its job, and a seal that is stiff and cold to the touch is telling the round the heater has failed. Where the doorset carries a heater wire, the wire is checked in the first week and on every round after, because a failed wire leaves the seal to freeze with no warning. The fire door hardware guide deals with the grades and parts that keep a cold room door working, and the dock doors where the stock arrives take their own schedule.
Never force a frozen doorset open. Warm the seal, free it gently, and check the face of the seal for tears before the room goes back into use. A torn seal lets warm air in all shift, and the frost returns by the next morning. The warehouse security doors guide covers the store room doors that hold the stock. Send the room plan with the temperature each room must hold, and the enquiry checklist lists the room details to send with the order.
| Sign at the threshold | What it means | Round action |
|---|---|---|
| Frost along one side | Seal hard on that side | Record it, book a seal change |
| Frost all round | Doorset out of square | Check the frame and the hinges |
| Seal stiff and cold | Heater wire has failed | Test the wire, change it |
| Seal torn after forcing | Warm air enters all shift | Change the seal before next use |
Hinges, locks and handles at low temperature
Hinges on a cold store door must carry the leaf through the daily cycle in the cold, and they are proved by cycles and by load. Hinges to BS EN 1935 are proved through 200,000 cycles, with grade 13 carrying 120 kg and grade 14 carrying 160 kg, so the hinge should be chosen for the weight of the leaf it carries.
Locks and handles on a cold room must work with gloves on, because staff in a freezer wear them. A small handle that needs bare fingers is a handle nobody can use, so the handle should be chosen for the hand that will use it, and the lock should shut the door without a struggle, because a door that will not latch is a door that stands open.
Every cold room door must open from the inside without a key, because a person shut in a cold room has minutes, not hours. The release inside the room belongs on the order beside the lock, and it must work when the room is at its coldest, so the release is checked on every round.
Sliding or hinged: the leaf that suits the room and the traffic
A cold store leaf hangs on hinges or runs on a track, and the choice follows the room and the traffic through it. A hinged leaf suits a small room where staff pass on foot, because it shuts fast, seals all round the leaf and needs no track across the opening. A hinged leaf swings into the room or out into the corridor, so the arc must stay clear of racking and trolleys, and a leaf that meets a pallet in its arc will not shut.
A sliding leaf suits a wide opening where trolleys and pallet trucks pass all day, because the leaf runs along the wall and leaves the whole opening clear. The track must stay clear of ice and dirt, because a track that has frozen leaves the leaf short of its shut position, and the seal along the track must hold when the leaf is shut, or warm air slips past it all day. A sliding leaf takes a heavier frame and a track fixed to solid wall, so the fixing goes on the order beside the leaf. The fire door inspection checklist sets out the checks each round should make.
The traffic decides the leaf. Forklifts and pallet trucks need the wide clear opening of a slider, staff on foot suit a hinged leaf that shuts behind them, and a room that takes both needs the slider with a hinged leaf beside it for staff. The sectional doors guide covers the wide leaves on the bays that feed the cold rooms, and the loading bay doors guide names the doors on the dock where the stock arrives.
Prove the door in its first week, before the handover is signed
A cold store door proves itself in its first week, and the proof belongs in the handover pack. The temperature log for the first days shows whether the room holds its temperature with the door in daily use, and a room that warms each time the door opens points at a leaf that does not shut or a seal that does not hold. The log should name the room, the temperature and the day, so the fault can be traced to the door that caused it.
Check the seal for frost on the first cold mornings, because warm air through a gap turns to frost on the seal, and frost freezes the seal to the frame. Check the heated seal wire as well, where the door carries one, because a wire that has failed leaves the seal to freeze. The release inside the room must be tested at the coldest temperature the room reaches, because a release that works in a warm store and sticks in a freezer is no release at all.
Ask for the record before the handover is signed: the temperature log, the seal check and the release test, each named against the room it belongs to. The fire door hardware guide covers the grades and the parts behind a working cold room door, and the doors on the store rooms that hold the stock are covered in the warehouse security doors guide. The security door maintenance checklist names the round that keeps the seals, hinges and release working. Send the room plan and the temperature each room must hold, and we will price a tested door for the cold rooms within one working day.
| Check | When | What passes |
|---|---|---|
| Temperature log | First week, daily | Room holds its temperature in daily use |
| Seal and frost | First cold mornings | Seal soft, no frost on the frame |
| Heated seal wire | First week | Wire warms, seal stays free |
| Inside release | At the coldest temperature | Opens without a key, by hand |
Fire and security on one leaf: the cold room that needs both proofs
A cold store door on a compartment wall must hold fire back for its period, and a door on the boundary must resist a forced entry, and a door that must do both needs a proof for each job. Fire is proved to EN 1634-1, with FD30 or FD60 and the letters E, EW or EI naming what the furnace measured, and forced entry is proved to LPS 1175, with the grades in full on our LPS 1175 page.
LPS 1175 grades the forced entry side, B3 for three minutes against category B tools, C5 for five minutes against category C tools and D10 for ten minutes against category D tools, under Issue 8.2, dated September 2024. The two proofs sit on the same schedule line.
The frame and the fixings carry the rating as much as the leaf does, because the proof names the whole doorset as fitted. A leaf proved to the rating, set in a frame that was never tested with it, has no rating. How the two proofs sit together is worked through in our fire and security doors dual certification guide, and the periods in full are on our fire ratings page.
Access control for the cold store: who opens the door, and when
The cold store should open for the staff who belong there and stay shut for the rest. A card or a fob opens the door for the staff who use the store every day, and an intercom at the door lets a visitor ask to be let in, so the record shows who opened the door and when.
Run the cold store door on the same system as the rest of the site, so one card opens the store, the staff areas and the yard, and one stopped card stops working everywhere at once. Readers, fobs and biometrics in the lane are covered in our security turnstiles guide.
The access control must not trap anyone inside. A door that locks from the outside and will not open from the inside is a danger in a cold room, so the release inside the room works on power failure as well as on alarm, and the release is written into the order beside the reader.
Defrost, drainage and the floor under the door
A cold room runs a defrost cycle, and the water from that cycle must go somewhere. A drain in front of the door takes the water away, and a floor that falls away from the door keeps it from running back under the leaf.
Ice on the floor in front of a cold store door is a slip for the staff who use it. The floor and the drain should be checked on the inspection round, so the round covers the floor as well as the door, and the checks each round should make are set out in our security door maintenance checklist.
The plant that runs the cold room sits behind the door, and the door must let the engineers reach it. A door that blocks the plant room is a door that stops the service visit, so the clear width belongs on the schedule.
The cold store order: one schedule for every cold room
Write the enquiry as one schedule with a line for every cold room on the site, and put the position, the temperature, the insulation, the rating, the hardware and the seals on each line, so the door that arrives is the door that was proved.
Keep the test report, the rating and the service schedule with the door from the day it arrives, and write the inspection routine into the handover pack. The columns such a schedule needs are set out in our how to specify security doors guide, and what each step up the scale adds to the build is worked through in our security door cost factors guide.
Put the quotes side by side and check each line, because the quote that leaves a seal or a closer off the list is not cheaper, only shorter, and the missing line is paid for later. The checks each round should make are set out in our fire door inspection checklist, and the mistakes to avoid are set out in our security door specification mistakes guide.
| Position | Door | Rating | What to check |
|---|---|---|---|
| Chiller room | Insulated door | FD30 | Seals, closer, latch |
| Freezer room | Insulated door | FD30 | Heated seal, threshold, drain |
| Blast chiller | Insulated door | FD60 | Seals, hinges, release |
| Loading dock | Insulated door | LPS 1175 B3 | Frame, fixings, closer |
| Staff entrance | Insulated door | LPS 1175 C5 | Lock, handle, reader |
A cold store door holds the cold in and the warm air out, so the insulation, the seals and the hardware must all sit on the same schedule.
What temperature do cold store doors hold?
A chiller door holds a room a few degrees above freezing, and a freezer door holds a room well below freezing, down to minus 18 degrees and lower, with the insulation and the seal chosen for the temperature the room must hold.
Why does a cold store door need a heated seal?
Warm air that reaches a freezer door turns to frost on the seal, and frost freezes the seal to the frame. A heated seal keeps the seal free of frost, so the door shuts and opens through the working day.
Can a cold store door hold a fire rating?
Yes, where the door is tested for the job. Fire is proved to EN 1634-1, with FD30 or FD60 naming the period, and forced entry is proved to LPS 1175, with B3, C5 and D10 naming three, five and ten minutes.
What happens if someone is locked in a cold room?
The door must open from the inside without a key, and the release inside the room must work when the room is at its coldest. The release is written into the order beside the lock and checked on every round.
Who checks cold store doors?
Checks fall to the cold store team, working to the schedule the site keeps, and each visit leaves a note of the door checked, the fault found, the repair made and the day it was done.
To get one quote for every opening, use the security door enquiry checklist and send the list in one go.
Get a free quote
Related
More in guides for specifiers
Products
One supplier for the whole building envelope
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.