Certified physical security

ArxBridge
Steel door sample in a security test frame with an assessor in a UK test laboratory

ArxBridge

Security Doors for Mental Health Units

A mental health unit holds locked wards, a medicines store and rooms where staff must open a leaf fast, so each leaf takes the LPS 1175 grade its room demands.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed across the UK
Prefer to talk?+44 7352 267239

Get a free project quote

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

A mental health unit keeps people who are unwell behind ward doors that lock, and the leaves round the ward must stand up to force while letting staff through fast. The entrance takes staff and visitors in, the reception takes them to the ward, the medicines store holds the drugs, the staff office holds the keys and the records, the plant room keeps the building running, and the ward bedroom doors stand between each patient and the corridor.

Issue 8.2 of LPS 1175, dated September 2024, puts a grade on a leaf by the minutes it stands against the tools the test names. B3 holds for three minutes, C5 holds for five minutes and D10 holds for ten minutes, and an old drawing may still show the same three leaves as SR2, SR3 and SR4, so the order carries both names beside each leaf.

A mental health unit is not a general hospital ward, because the ward doors lock and the people behind them are vulnerable, and it is not a care home, because the bedrooms sit behind a locked ward rather than along an open corridor. The hospital security doors guide grades the doors round a hospital and its wards, and the security doors for GP surgeries guide grades the doors of a practice that treats patients through the day, while the leaves in a mental health unit follow the locked ward and the medicines store behind it.

  • B3 / C5 / D10Grades to LPS 1175 Issue 8.2
  • Medicines storeWhere D10 sits in the unit
  • Locked wardWhere the grade meets the lock
  • One listEvery unit leaf named

Five rooms in a mental health unit: the grade each leaf takes

Five rooms make up a mental health unit, and the grade follows what each room holds. The entrance takes staff and visitors in, the reception sits between the entrance and the ward, the medicines store holds the drugs the ward runs on, the staff office holds the keys and the records, and the plant room keeps the building running behind the ward.

B3 sits on the entrance leaf and on the reception leaf, because both leaves stand where staff can see them through the day. C5 goes on the staff office and the plant room, because the keys, the records and the plant behind those leaves ask for a longer hold than the entrance. The medicines store takes D10, because the drugs behind it are the most portable value in the building and the leaf is shut and locked whenever no one is working inside.

Ward bedroom doors take the grade the ward demands, so the order names the grade for each bedroom leaf beside the grade for the five rooms. Each opening takes a line of its own on the order, naming the leaf, the grade and the minutes, so the fitter can match every leaf to its line before it is hung.

Room Grade Minutes What to check
Entrance B3 3 Leaf, lock, closer
Reception B3 3 Leaf, lock, reader
Medicines store D10 10 Leaf, lock, hinges
Staff office C5 5 Leaf, lock, reader
Plant room C5 5 Leaf, lock, seals
Ward bedroom Ward grade As set Leaf, lock, hardware

A leaf on the ward may need to hold fire as well as forced entry, and the two proofs sit in one report for the same doorset. EN 1634-1 counts the fire minutes from 30 to 120, with E for flames alone, EW for flames with part of the heat held back and EI for flames with the heat held back as well, while LPS 1175 Issue 8.2 of September 2024 sets the forced entry grade as B3, C5 or D10. How the two proofs sit on one leaf is shown in the fire and security doors dual certification guide, the changes Issue 8.2 brought are set out in the LPS 1175 Issue 8 explained guide, and the SR2 vs SR3 vs SR4 guide puts the old names beside the new grades.

The ward entrance: a B3 leaf between the corridor and the ward

Staff pass through the ward entrance through the day, and the leaf between the corridor and the ward stays shut and locked between each pass. The leaf must open fast to a card or a key in staff hands, and it must shut fully behind them, so the ward behind it is never left open to the corridor.

The entrance asks for three minutes because it stands in sight of the staff on the corridor, and three minutes gives the staff time to reach the leaf and raise help. A reader on the corridor side opens the leaf to staff cards, and a key override stands behind the reader for the day the reader fails. The access control doors guide covers readers and locks on a ward leaf, and the door entry systems guide covers the panel that lets staff through from the corridor.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Medicines store: D10 behind the drugs the ward holds

The medicines store holds the drugs the ward runs on, so its leaf takes D10, the longest hold LPS 1175 Issue 8.2 names. Leaf, frame, fixings and lock went through the test as one doorset, and the report puts ten minutes against the tools the test names.

No glass sits in the medicines store leaf, because a pane would show the corridor what the room holds and put a hand within reach of the lock, so the leaf runs solid steel from edge to edge. The hinges on a D10 leaf are proved to BS EN 1935, grade 13 carrying 120 kg and grade 14 carrying 160 kg, each proved through 200,000 cycles, so the leaf hangs true and the bolt still finds its keep.

Under TS 007, a 1 star cylinder beside a 2 star handle makes a 3 star set, so the cylinder and the handle are ordered as a pair and the cylinder on the medicines store leaf is the one the test saw with its handle. The security door locks guide names what the lock on the store must do, and the keys to the store are held by named staff only, with the names that may open it written on the list beside the leaf.

Ward bedroom doors: the grade the ward demands

A ward bedroom leaf stands between one patient and the corridor, so its grade follows what the ward asks of it rather than a fixed figure. The order names the grade for each bedroom leaf, and a bedroom leaf that needs a higher grade takes it, because the ward behind the leaf is locked and the people inside it are vulnerable.

The hardware on a bedroom leaf must not give a patient a point to tie to, and the detail of that hardware sits in the anti-ligature doors guide. What matters here is that the leaf, the lock and the hardware are ordered together, so the grade on the leaf is not lost by a fitting that was never proved with it.

Staff check on a patient through a glazed panel in the bedroom leaf, so the leaf stays shut while the patient is seen. Glass, bead and fixings go into the same report as the leaf round them, so the panel is proved with the leaf and not added after it. What can take a rating off a leaf once it is hung is named in the keeping an LPS 1175 rating valid guide.

Staff try the bedroom door on every round

A bedroom door on a mental health ward shuts for privacy first and opens for staff second. The thumb turn inside lets the person in the room shut the door without a key, and the key outside lets staff open the same door without a wait. Privacy rests on that pair working as one.

The round is the test. Staff walk the ward at set points through the day and the night, and each bedroom door is tried in turn as the round reaches it. The thumb turn is worked from inside the room, the key is worked from outside, and the door is watched as it meets its frame. A thumb turn that sticks or a key that drags is written down beside its room, so the fault is put right before the next round.

The key plan gives each member of staff the rooms their shift needs and no room past those, and the master key systems guide shows how such a plan is drawn room by room. The nurse in charge carries the key for the whole ward, while a nurse on one wing carries the key for that wing alone.

Moment What staff check What it proves
Start of the round Thumb turn inside Privacy without a key
Mid round Key outside Staff entry without delay
End of the round Door meets its frame A shut door that holds

The fittings on a bedroom door sit flush with the door, because a handle or a hook that stands proud of it is a point a cord can catch. The anti-ligature doors guide names the fittings that sit flat and give a patient nothing to hold.

Privacy holds when the thumb turn answers from inside

A thumb turn that answers at once is the heart of the room. The person inside turns it and the door stays shut, and staff outside know the room is in use without pushing the door open to look. A turn that needs force or a turn that spins without catching breaks that trust, because the person inside cannot tell from the turn alone whether the door is shut or not.

The lock on the bedroom door answers a key held by staff and the thumb turn inside, and the security door locks guide names the lock a bedroom door must carry and the way its parts work as one set. A key taken from a pocket on the corridor opens the bedroom doors on that wing and nothing past them.

The reader at the ward entrance writes down each opening, so the list shows which card opened the ward door and when, and a card reported lost is struck off the list the same day. The access control doors guide covers the readers that log each opening and the cards that open each door.

Once a month the ward manager walks the ward with the door list and works each bedroom door in turn. A fault found on that walk goes beside its own room the same day, so the door is put right before it is asked to hold again. The security door maintenance checklist guide sets out what that walk should look at on each door.

Ward bedrooms sit on one order with the rest of the ward, and the healthcare doors quote asks for the grade and the lock beside each room.

Staff office and plant room: C5 on the rooms behind the ward

Keys to the ward rooms and the papers that record the ward sit in the staff office, so its leaf takes C5 and stays locked when no one is inside, because an open office hands a passer by the keys to every room behind it.

Boards and equipment in the plant room keep the lights, the heating and the alarms running, so the leaf on that room takes C5. What a plant room leaf must do is covered in full in the plant room door requirements guide.

Keys and readers: who opens which leaf on the ward

Behind the reception, each leaf opens to the cards and keys of the staff who work there, and no card held on the public side opens any of them. The master key systems guide shows how a key plan gives each holder the rooms their work needs and no other room.

The ward manager holds a key that opens every leaf behind the reception, and the ward staff hold keys that open only the rooms their shifts take them to. How the order runs from the first leaf to the last is set out in the 10 steps to specify an LPS 1175 door guide.

A lost card is taken off the reader list the day it is reported, so a card found in the corridor opens nothing. The list of card holders is kept beside the door list, and the two lists are read together when a new member of staff joins the ward.

Who carries the ward key after the night shift changes hands?

The ward key passes from one shift to the next by hand, never through a drawer or a hook on the wall, because the leaf it opens guards the medicines store and the ward behind it. The nurse who takes the shift signs for the key at the desk, and the nurse who leaves hands it over in person, so the key is never out of sight between one holder and the next. A key left on a desk is a key any passer by can lift, and a ward leaf opened by the wrong hands is a leaf that never locked at all.

A key plan drawn for the ward gives each member of staff the leaves their shift needs and no leaf beyond those, and the guide to master key systems shows how those plans are drawn room by room. The ward manager carries one key for every leaf behind the reception, while a ward nurse carries a key for the rooms on that shift alone.

Holder Leaves it opens When it turns
Ward manager Every leaf behind reception Start of each shift
Ward nurse Rooms on that shift only When the shift begins
Night staff Ward entrance and medicines store On the night round

The reader beside the ward entrance writes down every opening, so the list shows which card opened the leaf and when it opened, and a card reported lost is struck off the list the same day it is reported. Card holders are listed beside the door list, so a new member of staff is added to both lists on the same day they join. The guide to access control doors covers the readers that log each opening and the cards that open each leaf.

When the alarm sounds the lock lets go of the leaf at once, and the same leaf that stood locked through the day swings open to one push, so the people behind it reach the corridor without a key in hand. The lock answers the alarm and the reader together, so the leaf stays shut to a card that is not on the list and opens to the alarm without a card at all.

The reader logs the opening while the ward stays locked

A key that opens the medicines store leaf opens nothing else on the ward, so a key taken from a pocket on the corridor opens one room and one room only. The cylinder and the handle on that leaf are ordered as a pair, and TS 007 counts the pair as a 3 star set when a 1 star cylinder sits beside a 2 star handle. The locks guide names what the lock on a store leaf must do when the room stands empty and the leaf is shut.

The fittings on a ward leaf give a patient nothing to catch hold of, because a handle or a hook that stands proud of the leaf is a point a ligature can catch. The guide to anti-ligature doors names the fittings that sit flush with the leaf and give a patient nothing to hold.

Once a month the ward manager walks the ward with the door list and works each leaf in turn, trying the key, watching the closer draw the leaf home, and reading the reader log against the names on the list. A fault found on that walk goes beside its own leaf the same day, so the leaf is put right before it is asked to hold again. The guide to the security door maintenance checklist sets out what that walk should look at on each leaf.

The list of leaves, keys and readers goes on one order. The healthcare doors quote page covers the ward room by room, so the key plan and the reader log stand on the same order as the leaves they guard.

Glazed leaves and the view of the ward: watching without opening

Staff at the reception watch the corridor through glass in the entrance and reception leaves, so the leaves stay shut while the people on the ward are still seen. Glass, bead and fixings are proved in the same report as the leaf that holds them.

A glazed leaf suits the entrance and the reception, and a solid leaf suits the medicines store, because the watched rooms take glass and the unwatched room takes steel. The steel door frames guide names how the frame holds the leaf and the lock together, and the keeping an LPS 1175 rating valid guide names what takes a rating off a leaf once it is hung.

Forced entry under EN 1627 runs from RC1 to RC6, and the LPS 1175 vs EN 1627 guide puts the two tests beside each other, with no claim that one equals the other. The LPS 1175 standard page names the grades B3, C5 and D10 with the minutes each one holds.

The mental health unit order: every leaf, its grade and its lock

One list carries the whole mental health unit order, with a line for every opening that names the leaf, the grade, the lock and the closer beside it. A leaf with no line of its own may be hung where it does not belong, and a C5 leaf on the medicines store holds for five minutes where the drugs ask for ten.

The ward manager takes the door list round the unit once a month and tries the leaves in turn, so every leaf is worked before the month is out. A dragging leaf, a bolt that misses its keep or a reader that stays silent goes on the list beside its own door on the day it is found, and the security door maintenance checklist names what the walk should cover.

The grade on a mental health unit leaf follows the room behind it, so the leaf, the lock and the reader are ordered together and checked together against the ward behind the leaf.

What grade should a mental health unit entrance door carry?

B3 to LPS 1175 Issue 8.2, which holds for three minutes, because the entrance stands in view of the staff on the corridor through the day.

What grade should a medicines store door carry?

D10 to LPS 1175 Issue 8.2, which holds for ten minutes, because the medicines store holds the drugs behind a shut leaf.

What grade should ward bedroom doors carry?

The grade the ward demands, because each bedroom leaf stands between one patient and the corridor, and the order names the grade for each bedroom leaf beside the five rooms.

Can one leaf hold fire and forced entry?

Yes, where the same leaf passed the fire test and the forced entry test, so one report names the period and the grade together.

Who checks the mental health unit doors?

The ward manager walks the unit with the door list each month and tries the leaves in turn, so a fault is found and put right before the leaf is asked to hold.

Specifying security doors for a mental health unit?Send the door list with the grade and the lock each room must hold for a tested door quotation.
Get a free quote

Related

More in guides for specifiers

10 mistakes when specifying certified security doors 10 steps to specify an LPS 1175 door Acceptance and Snagging of a Security Door or Barrier Job Access Control Doors Acoustic Doors: Ratings and Specification After a Forced Entry Attempt: Checking a Security Door Airport Security Doors Anti-Ligature Doors for Mental Health Wards Anti-Ram Bollards Anti-ram gates and barriers: protecting vehicle entrances Arcade Security Doors Explained Automatic Doors Automatic Gates Cost Factors Automatic Vehicle Barriers Ballistic Panels Bank Security Doors Bingo Hall Security Doors Explained Blast doors: glazed vs solid and how they are rated Blast protection window film: what it does and what it cannot do Blast resistant windows: what drives the cost and how to specify them Bollard Cost Factors Explained Bollard regulations in the UK: spacing, height and depth Bookmaker Security Doors Explained Builders Merchant Security Doors Bullet Resistant Glass Cost Factors Bullet resistant glass ratings explained: BR1 to BR7 and SG classes Bullet resistant vs bulletproof glass: what the difference means Buying Security Doors and HVM Through Public Frameworks Car Park Security Doors Explained Car Showroom Security Doors Casino Security Doors Explained CDM 2015 Duties When Security Doors, Shutters or HVM Are Installed Cinema Security Doors Cleanroom Doors Cold Store Doors College Security Doors Commissioning, Handover and the O&M Manual for Security Doors and HVM Communal entrance doors for flats: Secured by Design and what to specify Community Centre Security Doors Control Room Doors Court Security Doors Crash Rated Fences and HVM Fencing Explained Data centre physical security: doors, glazing, HVM and shielding by zone Dental Practice Security Doors Depot Security Doors Explained Door Entry Systems Due Diligence When Selecting Vehicle Security Barriers Emergency Exit Doors EMP Shielding Cost Factors Explained Exhibition Centre Fire Door Rules Exhibition Centre Security Doors Factory Security Doors Faraday cage vs RF shielded room: what a business needs FB4 vs FB6 vs FB7: how to choose a ballistic rating Fire and security doors: how dual certification works Fire Compartmentation Fire Curtains Fire Door Certification Fire Door Closers Explained Fire Door Cost Factors Fire Door Duties of the Accountable Person Fire Door Gaps Fire Door Hardware Explained Fire door inspection checklist for steel and timber doors Fire Door Maintenance Fire Door Regulations Care Homes Fire Door Regulations for A and E Departments Fire Door Regulations for Airports Explained Fire Door Regulations for Bowls Clubs Fire door regulations for commercial buildings in the UK Fire Door Regulations for Dialysis Centres Fire Door Regulations for Hockey Clubs Fire Door Regulations for Hospitals Explained Fire Door Regulations for Offices Explained Fire Door Regulations for Operating Theatres Fire Door Regulations for Retail Explained Fire Door Regulations for Schools Explained Fire Door Regulations for Snooker Clubs Fire Door Regulations for Stadiums Fire Door Regulations for Student Accommodation Fire Door Regulations for Warehouses Fire Door Regulations Leisure Centres Fire Door Regulations Restaurants Fire Door Remediation Programme for Housing Providers Fire Door Rules for Badminton Clubs Fire Door Rules for Bingo Halls Fire Door Rules for Bookmakers Fire Door Rules for Bowling Alleys Fire Door Rules for Car Parks Fire Door Rules for Car Showrooms Fire Door Rules for Cinemas Fire Door Rules for Climbing Centres Fire Door Rules for Colleges Fire Door Rules for Community Centres Fire Door Rules for Cricket Clubs Fire Door Rules for Dental Practices Fire Door Rules for Depots Explained Fire Door Rules for Golf Clubs Fire Door Rules for GP Surgeries Fire Door Rules for Gyms Explained Fire Door Rules for Ice Rinks Fire Door Rules for Maternity Units Fire Door Rules for Mental Health Units Fire Door Rules for Museums Fire Door Rules for Oncology Units Fire Door Rules for Opticians Fire Door Rules for Pawnbrokers Fire Door Rules for Petrol Stations Fire Door Rules for Pharmacies Fire Door Rules for Ports Fire Door Rules for Post Offices Fire Door Rules for Prisons Fire Door Rules for Rehabilitation Centres Fire Door Rules for Self Storage Fire Door Rules for Shopping Centres Fire Door Rules for Squash Clubs Fire Door Rules for Supermarkets Fire Door Rules for Swimming Pools Fire Door Rules for Tennis Clubs Fire Door Rules for Theatres Fire Door Rules for UK Arcades Fire Door Rules for UK Casinos Fire Door Rules for UK Hospices Fire Door Rules for Walk-in Centres Fire Door Signage Fire Door Vision Panels Fire Doors and Gateway 2 in Higher-Risk Buildings Fire Rated Glass Cost Explained Fire Rated Sliding Doors Explained Fire Rated Windows Cost Factors Fire Rated Windows Explained Fire Safety Enforcement Notices and Fire Doors: What the Responsible Person Must Do Flat Entrance Doors: PAS 24 and Fire Rated Forced Entry vs Ballistic vs Blast: Which Rating a Site Needs Garage Security Doors Explained Gate Automation Explained Golden Thread Records for Fire Doors GP Surgery Security Doors Explained Gym Security Doors Explained High Speed Doors HMO Fire Doors Hospice Security Doors Explained Hospital Security Doors: Wards, A&E, Plant Hospital Security Gates Hotel Fire Doors Hotel Security Doors How to choose HVM bollards: fixed, shallow mount, removable and automatic How to keep an LPS 1175 door rating valid after installation How to Specify Fire Doors in a Housing Tender How to specify security doors: a checklist for architects How to Verify a Secured by Design Listing How to Verify an LPS 1175 Certificate on Red Book Live How to Write an Operational Requirement for Physical Security HVM planters and street furniture: protection that blends in In-Service Care of Vehicle Security Barriers Installation Handover: LPS 1175 Doors and PAS 68 Barriers Intumescent Seals ISO 16933 explained: EXV and SB classes and hazard ratings ISO 22343 vehicle security barriers explained Keeping a Dual-Certified Fire and Security Door Valid in Service Laboratory Security Doors Layered Security for a Site: Deter, Detect, Delay, Mitigate, Respond Lead Times and Programme Risks for LPS 1175 Doors Leisure Centre Security Doors Library Security Doors Listed Building Fire Doors Loading Bay Doors Explained Lockdown and Access Control Hardware on an LPS 1175 Door LPS 1175 Gates and Grilles Explained LPS 1175 Issue 8 explained: from SR1 to SR8 to A1 to H20 LPS 1175 Roller Shutters LPS 1175 vs ASTM F2781 and Other US Ratings Explained LPS 1175 vs EN 1627: how UK and European burglar resistance ratings compare LPS 1175 vs PAS 24: which security standard does your door need? LPS 1175 Windows and Walling Explained Martyn’s Law and Places of Worship: What a Buyer Checks for Doors and Entry Control Martyn’s Law Enhanced Tier: Physical Measures and the Specifier Brief Martyn’s Law Standard Tier: Procedures, Doors and Shutters Martyn’s Law Timeline and the SIA Regulator Martyn’s Law: what premises must do and which physical measures to consider Master Key Systems MRI and RF shielded rooms: how they work and what to specify Museum Security Doors NPSA Catalogue of Security Equipment (CSE) Explained NPSA Forced Entry and Blast Guidance for Government Sites NPSA Guidance on Lockdown and Marauding Attack: What It Asks of Doors and Entrances Office Security Doors Optician Security Doors Explained Panic Hardware PAS 24 requirements for doors and windows explained PAS 68 Bollard Foundations Explained PAS 68 bollards: ratings, spacing and cost factors PAS 68 vs IWA 14 vs ISO 22343: hostile vehicle mitigation standards explained Pawnbroker Security Doors Explained Pedestrian Gates Petrol Station Security Doors Pharmacy Security Doors Planning Permission for Security Shutters, Gates and Bollards on Commercial Premises Plant room doors: fire, security and ventilation requirements Plant Room Fire Doors Port Security Doors Post Office Security Doors Explained Powder coating vs galvanising vs paint for steel Preliminary Market Engagement for Security Doors and HVM Prison Security Doors Programming a Security Door and Barrier Package on a Live Site Public-Sector Tender Response Checklist for Security Door and HVM Supply Reading a PAS 24 and SBD Door Test Report Regulation 38 Fire Safety Information at Handover for Fire-Rated Security Doorsets Replacing Security Doors in an Occupied Building Restaurant Security Doors Retail Security Doors Revolving Doors RF shielding standards and how shielded rooms are tested Rising Bollard Cost Factors Road Blocker Cost Factors Explained Road Blockers Explained Roller Shutter Cost Factors: What Drives the Price Roller shutter regulations in the UK: safety and maintenance Safe room and panic room doors: specification basics Safety Duties for Powered Doors, Gates and Barriers on Commercial Sites School Security Doors Sectional Doors Secured by Design explained: is it mandatory for doors? Secured by Design vs NPSA vs LPCB: Which One You Need Security Door Locks Security Door Maintenance Checklist Security Doors and Access for Everyone: What Approved Document M Asks Security Doors for A and E Departments Security Doors for Badminton Clubs Security Doors for Bowling Alleys Security Doors for Bowls Clubs Security Doors for Climbing Centres Security Doors for Cricket Clubs Security Doors for Dialysis Centres Security Doors for Golf Clubs Security Doors for Hockey Clubs Security Doors for Ice Rinks Security Doors for Maternity Units Security Doors for Oncology Units Security Doors for Operating Theatres Security Doors for Rehabilitation Centres Security Doors for Snooker Clubs Security Doors for Squash Clubs Security Doors for Swimming Pools Security Doors for Tennis Clubs Security Doors for Walk-in Centres Security Doors West Midlands Explained Security Fencing Security Gates Cost Factors Explained Security shutters vs high performance roller doors Security shutters vs retractable grilles: which suits retail and commercial openings? Security Turnstiles Explained Security Window Film Security Windows for Schools Explained Self Storage Security Doors Server Room Doors Explained Shopping Centre Security Doors Smoke Control Doors Explained Smoke Curtains Specification Mistakes When Mixing LPS 1175, PAS 24 and SBD in One Tender SR2 vs SR3 vs SR4 security doors: choosing the right LPS 1175 level Stadium Security Doors Steel Door Frames Steel vs aluminium security doors: strength, ratings and looks Steel vs timber fire doors: which suits your building? Student Accommodation Security Doors Substation doors: security, ventilation and specification Supermarket Security Doors Telescopic Bollards Tender Evaluation Criteria and Scoring for Security Doors and HVM The Scope of a Maintenance Contract for Security Doors and Barriers Theatre Security Doors Thermal and Weather Performance of External Security Doorsets Thermally broken steel security doors: U-values and certification Traffic Calming as Hostile Vehicle Mitigation Transport hub security requirements Turnstile Cost Factors Explained Turnstile vs speed gate vs security portal: choosing entrance control Types of security doors for commercial buildings University Security Doors Explained Vehicle Dynamics Assessment: What It Tells the Buyer Before a Barrier Is Specified Warehouse Security Doors Explained Warehouse Security Gates Warranty, Defects Liability and Guarantees for Security Doors and Barriers What affects the cost of a bullet resistant door What affects the cost of a high-security door in the UK Window Security Bars View all →

Products

One supplier for the whole building envelope

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.