An airport door works in two worlds at once. On one side it opens for passengers with bags and trolleys, on the other it guards the rooms and routes the public never sees. A door that fails on either side leaves the terminal open to the wrong person, or shuts the wrong person in.

The order starts with the terminal map, not with the leaf. A check-in hall that fills at dawn asks for a different door from a baggage hall where trolleys roll all day, and an airside door that only badged staff may open asks for a different lock from a door on a public concourse.

Every door in the terminal sits on one schedule, and an order that names each one plainly gets the right door on the right opening. The transport hubs sector page sets out the buildings these doors guard, and the transport hub security requirements guide covers the doors on the hub in full.

  • LPS 1175 B3 / C5 / D10Forced entry ratings, three, five and ten minutes
  • FD30 / FD60Fire resistance periods tested to EN 1634-1
  • ISO 22343-1Vehicle security barrier ratings
  • Martyn’s Law enhanced tierPremises holding 800 or more people

Terminals, baggage halls and airside: where an airport puts its doors

The public side of a terminal is check-in halls, departure lounges and arrivals, where doors open for crowds all day. The doors here must take constant use, trolleys and bags, and still shut on their own, because a door left open on a public concourse is a gap in the line.

Behind the public side sit the baggage halls, where trolleys and carts move goods between the terminal and the aircraft. The doors here are wider, the leaves heavier, and the hardware must take the knocks of the working day, so the hinge and the closer belong on the schedule beside the leaf.

Airside is the third world, the stands and service roads where only badged staff may go. A door onto airside must open for a pass the system knows and stay shut for the rest, and the fire door regulations for airports guide sets out the periods for the doors inside a terminal.

Public doors and restricted doors: the line between the two

Every door in a terminal sits on one side of a line. Public doors open for anyone in the building, while restricted doors open only for a pass, and the line between them is drawn on the plan before the order is placed, so no door is left to decide for itself.

The restricted side holds the baggage halls, the plant rooms, the server rooms and the corridors that lead airside. A door on this side takes a reader and a lock that records who passed, because the record matters as much as the leaf.

A door that straddles the line fails both sides. A public door with a reader nobody uses is a lock with no purpose, and a restricted door that stands open is a gap, so each door should be named public or restricted on the schedule.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Airside passes and access control: who opens which door

An airside pass is the credential that opens the doors beyond the public side. A card or a fob opens the door for the staff who hold it, and a pass that has been stopped must stop working everywhere at once, so one stopped pass cannot open a door at the far end of the terminal.

The credential is checked at the door, and the lock answers it. A pass that belongs to a member of staff who has left must be stopped on the system the same day, because a pass that still works is a door left open.

Contractors who work airside for a day take a pass that dies at the end of the shift. The pass should end on its own, without anyone having to remember to stop it, and the record should name the person, the door and the day the pass ended. The turnstiles at the staff entrance are covered in the security turnstiles guide, and the choice between a turnstile, a speed gate and a portal is worked through in the turnstile versus speed gate versus portal guide.

A pass that outlives the person who holds it opens a door it should not

A pass is given to a person for a job, and the pass should end when the job ends. A member of staff who leaves takes no pass with them, because a pass that still works after the person has gone opens every door it ever opened, and the terminal has no way of knowing who holds it. The pass list is checked against the staff list on a set day each month, and every pass that belongs to a person no longer on the staff list is stopped that day, not at the next review. The check is written down beside each pass, with the name, the doors it opened and the day it was stopped, so the record shows the pass ended when the person left.

A contractor takes a pass for the work in hand, and the pass carries the end date of that work on the record beside it. A pass for a project that runs for weeks is signed by a named sponsor, and the sponsor signs again each week the pass stays live, so no pass runs on past the week it was needed for. A pass that is lost is reported the same day it is missed, and it is stopped everywhere at once, because a lost pass that still opens one door at the far end of the terminal is a door left open. A pass found after it was stopped stays stopped, and the person takes a new pass, because the stopped pass may have been copied while it was lost. The transport hub security requirements guide sets out the doors on the hub in full, and the fire door regulations airports guide sets out the periods for the doors inside a terminal.

Pass Who holds it When it ends
Staff pass A member of staff The day the person leaves
Contractor pass A contractor on a named job The end date on the record
Visitor pass A visitor under escort The end of the visit
Lost pass No one The day it is reported lost

The night the terminal empties, the doors still work

The terminal empties at night, but the doors do not stop working. Cleaning crews and maintenance staff move through the building after the last flight, and the readers still record each door they open, so the night has a record as full as the day. A door propped open for a cleaning trolley is a gap no one sees, and the night round checks each leaf is shut and each closer has pulled it home before the crew moves on. A fire door that stands open at night leaves the compartment open with it, and the closer that pulls it shut is part of the proof the door carries. The Martyn’s Law guide for premises sets out what the law asks of a premises and when, and the vehicle line outside the terminal is proved to ISO 22343-1, with the ISO 22343 vehicle security barriers guide setting out the ratings in full.

The handover between the day staff and the night staff names each door that was checked and each fault that was found, so the morning starts from the night record and not from a guess. A fault found at night goes beside the door it belongs to before the shift ends, and the repair is ordered before the next sitting of the day. The bollards on the forecourt take the same care, and the anti-ram bollards guide covers the rated options for the line outside the terminal. Put the pass list and the door schedule on one enquiry, and the security door enquiry checklist lists what to send so each door is quoted with its pass and its release.

Fire and security on one leaf: the terminal door that must do both

Some terminal doors carry two proofs. The fire proof names the period the leaf holds back fire, and the forced entry proof names the minutes it holds back attack, and each proof must name the same leaf, frame and hardware, because a door proved for one job and not the other leaves one side of the terminal unguarded.

Fire periods in a terminal follow the risk behind each door. A door on a corridor takes FD30, a door on a compartment wall takes FD60, and a door that guards a smoke path takes FD30S, with the seal proved to BS EN 1634-3, to Sa for smoke at room temperature and S200 for smoke at 200 degrees Celsius.

The dual certification guide covers how fire and forced entry proofs share one doorset. A closer that pulls the leaf shut every time is part of both proofs, with no fire door taking less than EN 3 to BS EN 1154, and the fire door closers guide covers the sizes and the fitting, while the fire door hardware guide covers the grades and the parts behind a working fire door.

Each door needs its fail position set before the power goes

A terminal runs on power, and a power cut asks every door the same question at once. A public door on the concourse must open so the crowd can leave, while a door onto airside must stay shut so the restricted side stays restricted, and a fire door must shut on its own so the compartment stays closed. The answer for each door is set before the order goes out, because a door that has never been told what to do on power loss will do whatever its lock does by default. Power operated doors take the rule in EN 12453, and terminal doors take the periods the fire door regulations airports guide gives them. A door on the baggage hall takes the same care, because trolleys roll through it all day and the hardware must take the knocks.

A reader that has lost power answers no pass, so the key beside it matters. A door that guards airside takes a key override that only named staff hold, and the turnstile beside it takes the same care, because a staff entrance that cannot open strands the people who must keep the terminal running. The security turnstiles guide takes the turnstiles at the staff entrance, and the doors on the hub in full are taken up in the transport hub security requirements guide. A hold-open device to BS EN 1155 lets go when the power or the alarm calls it, so the doorset it holds swings shut on its closer, and the closer that pulls it home belongs to the proof the door carries.

Door On power loss Why
Public entrance Opens The crowd must leave
Airside door Stays shut The restricted side stays shut
Fire door Shuts on its closer The compartment stays closed
Hold-open door Released, then shuts The alarm or the power lets it go

The blackout test sits on the round, beside the closer check

The round that looks after the doors should cut the power to one door at a time and watch what it does. A door that should open is pushed from the public side, a door that should stay shut is tried from the restricted side, and a door that should shut is watched until its closer pulls it home. Each result goes on the schedule beside its door, with the date and the name of the person who ran the test, so the next round starts from the last test and not from a guess. The fire door inspection checklist gives each round its list, and what the law asks of a premises that holds a crowd is set out in the Martyn’s Law guide for premises.

A fault found on the test goes on the list the same day, with the door, the lock and the release named beside it, because a door whose fail position is wrong is a door that will fail the same way on the night it really goes. A door that fails the test stays on the list until the repair is done, and its opening is not left to a door that may not shut. Send the fail position of every door on the schedule. The security door enquiry checklist shows what the enquiry must hold, so each door is quoted with its power supply and its release.

The vehicle line outside the terminal: bollards, barriers and the forecourt

The forecourt is where vehicles reach the terminal, and the line outside it decides what may pass. Bollards, barriers and gates stand between the road and the frontage, so a vehicle that will not stop meets steel before it meets glass.

Vehicle ratings are proved to ISO 22343-1, which supersedes PAS 68:2013, with test vehicles from a 1,500 kg car to a 30,000 kg truck at 48, 64 or 80 km/h. The rating on the order should match the vehicle the approach could bring, and the ISO 22343 vehicle security barriers guide sets out the ratings in full.

ProtectUK sets the spacing on the line, with no more than 1,200 mm clear between bollards and a minimum height of 500 mm. The hostile vehicle mitigation page covers the line in full, and the anti-ram gates and barriers guide covers the rated options for the gate line.

Blast on the frontage: glass, frame and the stand-off

A terminal frontage faces the road, so the glass on it must be proved for the blast it could face. Windows are proved to ISO 16933, with EXV for a charge carried in a vehicle at a stand-off distance and SB for a hand-carried charge at the face, and the class on the order should match the threat the frontage faces.

The frame carries the rating as much as the glass does, because a blast that passes the pane still meets the frame. The frame, the beads and the fixings belong on the same line as the glass, so the window that arrives is the window that was tested.

The ratings in full are set out on the blast ratings page, and the windows that carry the rating are covered in the blast resistant windows guide. The vehicle ratings that guard the same frontage are set out on the vehicle impact ratings page, and the two proofs must stay on separate lines, because one test report cannot prove both.

Martyn’s Law and the crowded terminal: the enhanced tier

A terminal holds crowds, so it sits in the enhanced tier of Martyn’s Law, which covers premises that hold 800 or more people at a time. The law was given Royal Assent in April 2025, with go-live expected in spring 2027, and it asks the largest premises to plan for a terror attack and to keep the plan in practice.

Doors play their part in that plan. Escape routes must open when the alarm sounds, with no key, no card and no code standing between the crowd and the street, and the doors on those routes must release at once, for everyone in the building, including a passenger who has never seen the terminal before.

The Martyn’s Law guide for premises sets out what the law asks of a premises and when. The doors that serve the escape routes are covered in the smoke control doors guide, which covers the doors that must hold smoke back while people move past them.

One schedule for the whole airport: every door on one line

Write the enquiry as one schedule with a line for every door in the terminal, and put the position, the fire period, the forced entry rating, the glazing and the hardware on each line, so the door that arrives is the door that was proved.

Check each quote against the schedule before the order is placed, because a quote that leaves a closer or a seal off the list will cost the same part later, fitted round a door that is already in use. The security door cost factors guide sets out what each step up the scale adds to the build, and the how to specify security doors guide sets out the columns the schedule needs.

File the test reports and the inspection routine with the doors when they arrive, so the record covers the whole life of every door in the terminal. The fire door inspection checklist names what each round should look for, and the keeping an LPS 1175 rating valid guide sets out what breaks a rating.

Position Door Rating What to check
Check-in hall Glazed security door LPS 1175 B3 Glass, frame, closer
Baggage hall Solid security door LPS 1175 C5 Lock, hinges, closer
Airside door Fire and security door FD30 + B3 Seals, reader, release
Escape route Fire door FD30S Seals, closer, release
Plant room Fire door FD60 Seals, closer, latch

Terminals, baggage halls and airside each ask a different door, so the rating, the credential and the release must all sit on the same schedule.

What rating do airport security doors need?

The opening decides. Forced entry is proved to LPS 1175, with B3, C5 and D10 naming three, five and ten minutes, and fire is proved to EN 1634-1, with FD30 or FD60 naming the period.

Who may open an airside door?

Only a person who holds a pass the system knows. A pass that has been stopped must stop working everywhere at once, and a door onto airside must stay shut for anyone without one.

Do terminal doors need a fire rating?

Where the door sits on an escape route or a compartment wall, yes. Fire is proved to EN 1634-1 with the frame and the fixings, and the period follows the fire load behind the door.

What guards the forecourt outside the terminal?

Bollards, barriers and gates, proved to ISO 22343-1, with no more than 1,200 mm clear between bollards and a minimum height of 500 mm.

Who checks airport security doors?

The terminal team, on the routine the fire risk assessment sets. Every round covers the closers, the seals, the locks and the readers, and every fault found is written on the record the same day.

Specifying security doors for an airport?Send the door schedule and the terminal plan for a tested door quotation.
Get a free quote

Related

More in guides for specifiers

10 mistakes when specifying certified security doors 10 steps to specify an LPS 1175 door Acceptance and Snagging of a Security Door or Barrier Job Access Control Doors Acoustic Doors: Ratings and Specification After a Forced Entry Attempt: Checking a Security Door Anti-Ligature Doors for Mental Health Wards Anti-Ram Bollards Anti-ram gates and barriers: protecting vehicle entrances Arcade Security Doors Explained Automatic Doors Automatic Gates Cost Factors Automatic Vehicle Barriers Ballistic Panels Bank Security Doors Bingo Hall Security Doors Explained Blast doors: glazed vs solid and how they are rated Blast protection window film: what it does and what it cannot do Blast resistant windows: what drives the cost and how to specify them Bollard Cost Factors Explained Bollard regulations in the UK: spacing, height and depth Bookmaker Security Doors Explained Builders Merchant Security Doors Bullet Resistant Glass Cost Factors Bullet resistant glass ratings explained: BR1 to BR7 and SG classes Bullet resistant vs bulletproof glass: what the difference means Buying Security Doors and HVM Through Public Frameworks Car Park Security Doors Explained Car Showroom Security Doors Casino Security Doors Explained CDM 2015 Duties When Security Doors, Shutters or HVM Are Installed Cinema Security Doors Cleanroom Doors Cold Store Doors College Security Doors Commissioning, Handover and the O&M Manual for Security Doors and HVM Communal entrance doors for flats: Secured by Design and what to specify Community Centre Security Doors Control Room Doors Court Security Doors Crash Rated Fences and HVM Fencing Explained Data centre physical security: doors, glazing, HVM and shielding by zone Dental Practice Security Doors Depot Security Doors Explained Door Entry Systems Due Diligence When Selecting Vehicle Security Barriers Emergency Exit Doors EMP Shielding Cost Factors Explained Exhibition Centre Fire Door Rules Exhibition Centre Security Doors Factory Security Doors Faraday cage vs RF shielded room: what a business needs FB4 vs FB6 vs FB7: how to choose a ballistic rating Fire and security doors: how dual certification works Fire Compartmentation Fire Curtains Fire Door Certification Fire Door Closers Explained Fire Door Cost Factors Fire Door Duties of the Accountable Person Fire Door Gaps Fire Door Hardware Explained Fire door inspection checklist for steel and timber doors Fire Door Maintenance Fire Door Regulations Care Homes Fire Door Regulations for A and E Departments Fire Door Regulations for Airports Explained Fire Door Regulations for Bowls Clubs Fire door regulations for commercial buildings in the UK Fire Door Regulations for Dialysis Centres Fire Door Regulations for Hockey Clubs Fire Door Regulations for Hospitals Explained Fire Door Regulations for Offices Explained Fire Door Regulations for Operating Theatres Fire Door Regulations for Retail Explained Fire Door Regulations for Schools Explained Fire Door Regulations for Snooker Clubs Fire Door Regulations for Stadiums Fire Door Regulations for Student Accommodation Fire Door Regulations for Warehouses Fire Door Regulations Leisure Centres Fire Door Regulations Restaurants Fire Door Remediation Programme for Housing Providers Fire Door Rules for Badminton Clubs Fire Door Rules for Bingo Halls Fire Door Rules for Bookmakers Fire Door Rules for Bowling Alleys Fire Door Rules for Car Parks Fire Door Rules for Car Showrooms Fire Door Rules for Cinemas Fire Door Rules for Climbing Centres Fire Door Rules for Colleges Fire Door Rules for Community Centres Fire Door Rules for Cricket Clubs Fire Door Rules for Dental Practices Fire Door Rules for Depots Explained Fire Door Rules for Golf Clubs Fire Door Rules for GP Surgeries Fire Door Rules for Gyms Explained Fire Door Rules for Ice Rinks Fire Door Rules for Maternity Units Fire Door Rules for Mental Health Units Fire Door Rules for Museums Fire Door Rules for Oncology Units Fire Door Rules for Opticians Fire Door Rules for Pawnbrokers Fire Door Rules for Petrol Stations Fire Door Rules for Pharmacies Fire Door Rules for Ports Fire Door Rules for Post Offices Fire Door Rules for Prisons Fire Door Rules for Rehabilitation Centres Fire Door Rules for Self Storage Fire Door Rules for Shopping Centres Fire Door Rules for Squash Clubs Fire Door Rules for Supermarkets Fire Door Rules for Swimming Pools Fire Door Rules for Tennis Clubs Fire Door Rules for Theatres Fire Door Rules for UK Arcades Fire Door Rules for UK Casinos Fire Door Rules for UK Hospices Fire Door Rules for Walk-in Centres Fire Door Signage Fire Door Vision Panels Fire Doors and Gateway 2 in Higher-Risk Buildings Fire Rated Glass Cost Explained Fire Rated Sliding Doors Explained Fire Rated Windows Cost Factors Fire Rated Windows Explained Fire Safety Enforcement Notices and Fire Doors: What the Responsible Person Must Do Flat Entrance Doors: PAS 24 and Fire Rated Forced Entry vs Ballistic vs Blast: Which Rating a Site Needs Garage Security Doors Explained Gate Automation Explained Golden Thread Records for Fire Doors GP Surgery Security Doors Explained Gym Security Doors Explained High Speed Doors HMO Fire Doors Hospice Security Doors Explained Hospital Security Doors: Wards, A&E, Plant Hospital Security Gates Hotel Fire Doors Hotel Security Doors How to choose HVM bollards: fixed, shallow mount, removable and automatic How to keep an LPS 1175 door rating valid after installation How to Specify Fire Doors in a Housing Tender How to specify security doors: a checklist for architects How to Verify a Secured by Design Listing How to Verify an LPS 1175 Certificate on Red Book Live How to Write an Operational Requirement for Physical Security HVM planters and street furniture: protection that blends in In-Service Care of Vehicle Security Barriers Installation Handover: LPS 1175 Doors and PAS 68 Barriers Intumescent Seals ISO 16933 explained: EXV and SB classes and hazard ratings ISO 22343 vehicle security barriers explained Keeping a Dual-Certified Fire and Security Door Valid in Service Laboratory Security Doors Layered Security for a Site: Deter, Detect, Delay, Mitigate, Respond Lead Times and Programme Risks for LPS 1175 Doors Leisure Centre Security Doors Library Security Doors Listed Building Fire Doors Loading Bay Doors Explained Lockdown and Access Control Hardware on an LPS 1175 Door LPS 1175 Gates and Grilles Explained LPS 1175 Issue 8 explained: from SR1 to SR8 to A1 to H20 LPS 1175 Roller Shutters LPS 1175 vs ASTM F2781 and Other US Ratings Explained LPS 1175 vs EN 1627: how UK and European burglar resistance ratings compare LPS 1175 vs PAS 24: which security standard does your door need? LPS 1175 Windows and Walling Explained Martyn’s Law and Places of Worship: What a Buyer Checks for Doors and Entry Control Martyn’s Law Enhanced Tier: Physical Measures and the Specifier Brief Martyn’s Law Standard Tier: Procedures, Doors and Shutters Martyn’s Law Timeline and the SIA Regulator Martyn’s Law: what premises must do and which physical measures to consider Master Key Systems MRI and RF shielded rooms: how they work and what to specify Museum Security Doors NPSA Catalogue of Security Equipment (CSE) Explained NPSA Forced Entry and Blast Guidance for Government Sites NPSA Guidance on Lockdown and Marauding Attack: What It Asks of Doors and Entrances Office Security Doors Optician Security Doors Explained Panic Hardware PAS 24 requirements for doors and windows explained PAS 68 Bollard Foundations Explained PAS 68 bollards: ratings, spacing and cost factors PAS 68 vs IWA 14 vs ISO 22343: hostile vehicle mitigation standards explained Pawnbroker Security Doors Explained Pedestrian Gates Petrol Station Security Doors Pharmacy Security Doors Planning Permission for Security Shutters, Gates and Bollards on Commercial Premises Plant room doors: fire, security and ventilation requirements Plant Room Fire Doors Port Security Doors Post Office Security Doors Explained Powder coating vs galvanising vs paint for steel Preliminary Market Engagement for Security Doors and HVM Prison Security Doors Programming a Security Door and Barrier Package on a Live Site Public-Sector Tender Response Checklist for Security Door and HVM Supply Reading a PAS 24 and SBD Door Test Report Regulation 38 Fire Safety Information at Handover for Fire-Rated Security Doorsets Replacing Security Doors in an Occupied Building Restaurant Security Doors Retail Security Doors Revolving Doors RF shielding standards and how shielded rooms are tested Rising Bollard Cost Factors Road Blocker Cost Factors Explained Road Blockers Explained Roller Shutter Cost Factors: What Drives the Price Roller shutter regulations in the UK: safety and maintenance Safe room and panic room doors: specification basics Safety Duties for Powered Doors, Gates and Barriers on Commercial Sites School Security Doors Sectional Doors Secured by Design explained: is it mandatory for doors? Secured by Design vs NPSA vs LPCB: Which One You Need Security Door Locks Security Door Maintenance Checklist Security Doors and Access for Everyone: What Approved Document M Asks Security Doors for A and E Departments Security Doors for Badminton Clubs Security Doors for Bowling Alleys Security Doors for Bowls Clubs Security Doors for Climbing Centres Security Doors for Cricket Clubs Security Doors for Dialysis Centres Security Doors for Golf Clubs Security Doors for Hockey Clubs Security Doors for Ice Rinks Security Doors for Maternity Units Security Doors for Mental Health Units Security Doors for Oncology Units Security Doors for Operating Theatres Security Doors for Rehabilitation Centres Security Doors for Snooker Clubs Security Doors for Squash Clubs Security Doors for Swimming Pools Security Doors for Tennis Clubs Security Doors for Walk-in Centres Security Doors West Midlands Explained Security Fencing Security Gates Cost Factors Explained Security shutters vs high performance roller doors Security shutters vs retractable grilles: which suits retail and commercial openings? Security Turnstiles Explained Security Window Film Security Windows for Schools Explained Self Storage Security Doors Server Room Doors Explained Shopping Centre Security Doors Smoke Control Doors Explained Smoke Curtains Specification Mistakes When Mixing LPS 1175, PAS 24 and SBD in One Tender SR2 vs SR3 vs SR4 security doors: choosing the right LPS 1175 level Stadium Security Doors Steel Door Frames Steel vs aluminium security doors: strength, ratings and looks Steel vs timber fire doors: which suits your building? Student Accommodation Security Doors Substation doors: security, ventilation and specification Supermarket Security Doors Telescopic Bollards Tender Evaluation Criteria and Scoring for Security Doors and HVM The Scope of a Maintenance Contract for Security Doors and Barriers Theatre Security Doors Thermal and Weather Performance of External Security Doorsets Thermally broken steel security doors: U-values and certification Traffic Calming as Hostile Vehicle Mitigation Transport hub security requirements Turnstile Cost Factors Explained Turnstile vs speed gate vs security portal: choosing entrance control Types of security doors for commercial buildings University Security Doors Explained Vehicle Dynamics Assessment: What It Tells the Buyer Before a Barrier Is Specified Warehouse Security Doors Explained Warehouse Security Gates Warranty, Defects Liability and Guarantees for Security Doors and Barriers What affects the cost of a bullet resistant door What affects the cost of a high-security door in the UK Window Security Bars View all →

Products

One supplier for the whole building envelope

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.