Exhibition Centre Fire Door Rules
An exhibition centre fills with visitors who do not know the halls, so each fire door takes its period from the room behind the leaf, hall to plant room.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
An exhibition centre is a set of halls, stores and back offices behind one entrance, where visitors arrive for a show they have never seen and the fire doors keep a fire in the room where it began while the crowd finds the way out. The period on each door follows the room behind the leaf, because a hall full of stands and visitors asks more of its doors than a back office full of paperwork.
Exhibition centres share their fire rules with stadiums, set out in the fire door regulations stadiums guide, while the doors that guard the crowds in a leisure centre are covered in the fire door regulations leisure centres guide. The centre order names every opening with its period and its hardware beside it, so the leaf that arrives is the leaf the room asked for.
Before a single leaf is ordered the centre writes down its fire plan, giving each opening the period it must hold and each visitor the route they must follow, and the order is built from that plan door by door.
- FD30 / FD60Fire periods to EN 1634-1
- E / EW / EI 30-120What the letters beside the period mean
- Sa / S200Smoke proof to BS EN 1634-3
- One listEvery exhibition door named
Halls, stores and back offices: one exhibition centre, three periods
An exhibition centre works as three places: the halls where the shows are held, the stores where the stands and the crates sit, and the back offices where the bookings are made and the records are kept. The rules follow those places, because a leaf between a hall and a stores room must hold the fire on the side where it started while the people on the far side reach the way out.
The halls take the doors that let visitors and exhibitors pass in and out through the day, and each leaf must open for a visitor who has never seen the building before. The stores take the doors that guard the stands, and each leaf must hold the fire back where the crates sit in rows.
The plan gives every opening a door of its own, so a leaf ordered for the back office never ends up guarding the hall, and a leaf ordered for the stores never ends up on the route.
FD30 and FD60 in an exhibition centre: which room takes which period
Each part of an exhibition centre asks a different period of its doors, because the load behind each leaf differs. The halls hold stands, cables and crowds, the stores hold crates in rows, and the plant room holds the machinery that serves the whole centre, so the period on each door follows the room and never the leaf alone.
A fire door takes its period from a test to EN 1634-1, where the leaf is set in a furnace and the minutes are counted while the flames and the heat work on it. The result is written as minutes beside letters, and the letters name what the leaf held back: flames alone, flames with some of the heat, or flames with the heat as well.
The heavier the proof, the heavier the leaf, so the frame must be deeper and the hinges stronger, and the figure on the order climbs as the period climbs. An opening that asks for 60 minutes cannot take a 30-minute leaf, because the leaf with the shortest proof gives way first and the wall goes with it.
The exhibition hall: crowds, stands and the doors around them
A hall is a wide room full of stands, cables and visitors, and the doors on it must hold their proof while letting crowds pass through. A glazed leaf lets the staff see the hall beyond it without opening the leaf, and the pane takes the same proof as the leaf, because leaf and glass are proved as one doorset.
The stands and the cables in a hall carry a fire load of their own, and the doors between the hall and the stores must hold the fire where it starts. A leaf between the two takes the period the stores demand, because a fire that starts among the crates must stay there while the visitors move out.
The windows in the same walls are covered in the fire rated windows guide, and what the glass adds to the order is worked through in the fire rated glass cost guide.
Stores and the loading bay: the doors behind the halls
The stores hold the heaviest fire load in the centre, because the stands and the crates sit there in rows and on pallets between shows. A stores leaf takes FD60, because the period is set by what sits behind the leaf, not by the size of the room.
Deliveries reach the centre through the loading bay, and the doors there stand open while the crates come in. A leaf that must stand open takes a hold-open device proved to BS EN 1155, which releases the leaf the moment the alarm sounds. A crate wedged under a leaf is not a hold-open device, because the leaf it holds open cannot shut when the fire reaches it.
What the bay doors must do is set out in the loading bay doors guide.
The back office and the plant room: the rooms that keep the centre running
The back office holds the bookings and the records, and its leaf takes the period the room beside it takes. A back office leaf takes FD60 where the office sits beside the halls, because a fire that starts among the stands must not reach the records.
The plant room holds the machinery and the boards that serve the whole centre, so its leaf takes FD60 as well. The plant room door requirements guide sets out what the plant room leaf must do.
A leaf on an exhibition hall can carry two proofs at once, because the rooms behind it need fire held back and an intruder held out. The forced entry side follows LPS 1175 Issue 8.2 of September 2024, with B3 holding three minutes, C5 five and D10 ten. The LPS 1175 vs PAS 24 guide puts the two ratings side by side, the keeping an LPS 1175 rating valid guide lists the faults that undo a rating after fitting, and how one doorset carries both proofs is shown in the fire and security doors dual certification guide.
Getting a full hall out: exhibition centre escape routes
The alarm in an exhibition centre sends the visitors in the hall toward the exits the signs name, and nothing may stand on the way between the stands and the doors. A leaf on that way opens for the first person to reach it with one push, and it opens the same way when the lights have gone out.
Each door on the route takes a smoke rating beside its fire period, and BS EN 1634-3 gives it: Sa for smoke at room temperature, S200 for smoke at 200 degrees. Either mark works only where the seal meets the frame all the way round, because smoke reaches the route ahead of the flames. The smoke control doors guide shows how the doors keep smoke back while the crowd moves past them.
An exhibition centre is a crowded place, so the physical measures that support the risk assessment are set out in the Martyn’s Law guide for premises. A route holds only as long as its weakest leaf, because the leaf with the shortest proof gives way first and takes the route with it. Every leaf on the route must carry the period the route needs, and the fire door regulations stadiums guide shows the same care with crowds leaving a stand.
| Position | Door | Period | What to check |
|---|---|---|---|
| Hall | Steel leaf | FD60 | Leaf, lock, seals |
| Stores | Steel leaf | FD60 | Leaf, lock, seals |
| Back office | Steel leaf | FD60 | Leaf, lock, seals |
| Plant room | Fire leaf | FD60 | Leaf, seals, gap |
| Public route | Fire leaf | FD30 | Leaf, bar, closer |
| Back of house | Steel leaf | FD60 | Leaf, closer, seals |
What keeps the period: closers, seals and gaps on exhibition doors
The closer on an exhibition leaf works harder than the closer on most other doors, because visitors pass through it all day between shows. BS EN 1154 sets EN 3 as the smallest closer power on a fire door, and the check is to open the leaf and see it shut on its own. A closer that has lost its pull leaves the leaf standing open after the crowd has passed.
The gap round the leaf is 4 mm, measured with a gauge, never by eye, because the eye cannot tell 4 mm from 6 mm. The intumescent seal sits in its groove round the leaf, and once the heat nears 200 to 250 degrees it swells to fill the gap the fire would use. A seal painted over cannot swell, and a seal that has slipped leaves the gap open, so the seal is checked on every round and the fault is written against its door on the day it is found.
The leaf hangs on hinges that take its weight through every swing, and a hinge with screws that have worked loose lets the leaf drop until it catches on the floor. The fire door hardware guide names what the lock the key turns must do, and the fire door closers guide covers closer sizes and fitting.
Ordering for an exhibition centre: one list for every door
The whole exhibition order sits on one list, and each door has its own line with the leaf, the period, the lock and the closer beside it, so what arrives matches the room it was ordered for. A list that names one leaf for the whole centre leaves the fitter to guess which part takes which period, and a leaf in the wrong hall guards the wrong thing.
The figures are checked against the schedule one door at a time before the order is sent, because a door left off the quotation is a door the centre still pays for, and a part added once the order has gone out costs more than the same part added before it. The how to specify security doors guide lists what the schedule must hold, and the security door cost factors guide sets out what each step up the grade adds to the figure.
Each month the centre manager walks the halls and tries the leaves in turn, from the entrance to the plant room. A leaf that drags, a seal out of its groove or a closer that has lost its pull is put down against its own door on the day it is found, and the repair is booked while the fault is still small. The record stays with the centre file, and the fire door inspection checklist sets out what the visit should cover.
An exhibition leaf holds only as long as the halls behind it and the route beside it, so the period, the release and the closer must all sit on the same list.
What period should an exhibition centre door carry?
An exhibition centre does not take one period on every leaf. The test to EN 1634-1 gives sixty minutes where the halls and stores need it and thirty on the public route, and the order must name each leaf by the room it guards.
Can one leaf hold fire and forced entry?
Yes, a single doorset can hold both proofs where it faced the fire test and the forced entry test together, on the same leaf, frame and seals.
Do exhibition centre doors need panic hardware?
Yes. Every leaf on the way out takes a bar proved to BS EN 1125, across at least 60 percent of the leaf, so the latch throws under one push from a visitor who has never used the door before.
What period should an exhibition hall door carry?
A hall leaf takes FD60, because the stands and the crowds behind it carry the heaviest fire load in the centre, and the stores beside the halls take FD60 for the same reason.
Who checks the exhibition centre doors?
The centre manager walks the round that covers every door in the building, and the record of each visit stays with the centre file.