ArxBridge
College Security Doors
A college guards classrooms, workshops and offices behind its doors, so each leaf takes the grade the room behind it demands, from entrance to plant room.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A college is a set of classrooms, workshops and offices under one roof, and the doors between those parts decide what stays where it belongs. The corridors hold the students, the workshops hold the tools, and the offices hold the records, so each door takes its proof from the room behind it.
LPS 1175 sets the grade on a college door, and the category follows the value behind the leaf. Issue 8.2, dated September 2024, names three categories: B3 at three minutes, C5 at five and D10 at ten. The entrance takes the lowest, the classroom corridors take the middle one, and the cash room takes the highest.
A college follows the same rules as any other education building, and the fire door regulations schools guide covers the fire rules for school buildings, while the university security doors guide covers the doors of a university. The college order names every door in the building, with the grade and the lock beside each one, so the door that arrives is the door the room needs.
- LPS 1175 B3 / C5 / D10Forced entry grades to Issue 8.2
- Classroom corridorsWhere the grade rises
- FD30 / FD60Fire periods to EN 1634-1
- One listEvery college door named
Classrooms, workshops and offices: one college, three grades
A college splits into three parts, and the grade follows what each part holds. The classrooms hold the students, the workshops hold the tools and the materials, and the office holds the fees and the records, so each part takes the doors its work demands.
The entrance takes the doors the students walk through all day, and each leaf must open for a student with books in hand and shut behind them on its own. The workshops take the doors the students never open alone, and each leaf must hold against the attack the tools behind it invite.
Every opening in the college is written down before any leaf is ordered, with the leaf it takes and the grade beside it. A leaf with no line on that list may be fitted to the wrong room, guarding the wrong thing.
The entrance and the corridors: the leaves students pass
The entrance leaf opens for every student who arrives and holds an intruder out once the college closes, and its leaf, frame and lock are proved as one doorset, with the report naming all three.
A closer on the entrance leaf brings it home after every student who passes, because a leaf left standing open guards nothing. The closer is set so the leaf returns to the frame without a slam, and the pull is checked by opening the leaf and letting it go.
Glazing in the entrance leaf lets the staff see who stands outside before the leaf opens, and the pane carries the same proof as the leaf beside it. What the glass itself costs is worked through in the fire rated glass cost guide, and the bead and the fixings that hold the pane are named in the test report.
Classroom corridors: the doors between lessons
The classroom corridor runs past every room in the college, and the leaf that guards it takes the grade the value behind it demands. A classroom corridor leaf takes C5, because the equipment behind it is worth the minutes it takes to break through, and the leaf must hold until the alarm is answered.
The corridor takes a lock the college team controls, because the students must never pass it alone after hours. A leaf that guards the corridor takes C5, while the cash room beside it takes D10 and the entrance takes B3.
The corridor needs a leaf that shuts out the noise as well as an intruder, because the sound of lessons must not carry from room to room. The leaf takes seals round its edges and a closer that brings it home after every member of staff who passes.
One doorset on the corridor can carry both proofs at once, because the corridor needs fire held back and an intruder held out. EN 1634-1 gives the fire proof in minutes and letters, E, EW and EI from 30 to 120, and LPS 1175 gives the forced entry proof in B3, C5 and D10. Both proofs are run on the same leaf, frame and seals, so a single report holds them both. How one doorset carries both proofs is worked through in the fire and security doors dual certification guide.
Workshops and stores: where the tools and materials wait
Behind the classrooms, the workshops hold the tools the students will need next, and the leaf takes the grade the value behind it demands. C5 suits the workshops, because the tools behind it justify the minutes it takes to break through, and the leaf must hold until the alarm is answered.
The stores beside the workshops take the same care, because the materials and the spares sit behind their doors. Their leaf takes a lock the tutor controls, and the doorset is proved as one piece, leaf, frame and lock together, with the report naming each part.
The college plant room holds the services that keep the building open, and the leaf that guards it takes the grade the value behind it demands. A plant room leaf takes C5, because the boards and the plant behind it are worth the minutes it takes to break through. The plant room door requirements guide sets out what the plant room leaf must do.
The office and the cash room: where the fees and records sit
No room in the college takes a higher grade than the cash room, because the fees sit behind its leaf. Its leaf, frame, fixings and lock are proved as one doorset, and the test report names each part, so the door that arrives is the door that was proved.
D10 suits the cash room, because it must hold longest, while the corridor beside it takes C5 and the entrance takes B3. Drawings drawn before Issue 8 name the same three categories SR2, SR3 and SR4, and the order carries the new name beside the old one so the fitter is not left guessing.
The office beside the cash room takes the same care, because the records and the keys sit behind its doors. An office leaf takes C5, and the lock on it takes the same key as the cash room, so the staff who work the office can open both without carrying two keys. What breaks a rating once a door is fitted is named in the keeping an LPS 1175 rating valid guide.
The leaf that holds fire and forced entry together
One college leaf can hold both proofs, because the classrooms ask for fire held back while the cash room asks for an intruder held out. EN 1634-1 proves the fire side in E, EW and EI with minutes from 30 to 120, and LPS 1175 proves the forced entry side in B3, C5 and D10, with the leaf, the frame and the seals facing both tests together so one report holds both proofs. How one doorset carries both proofs is worked through in the fire and security doors dual certification guide.
The period on a college door follows the room behind it, because the classrooms, the workshops and the office put different loads behind each leaf, while the grade follows the value behind it. The minutes run from 30 to 120 beside letters that name what stayed back: flames on their own, flames with some heat, or flames with the heat as well. A route door carries a smoke rating beside the fire period, proved to BS EN 1634-3, with Sa for smoke at room temperature and S200 for smoke at 200 degrees. The smoke control doors guide covers how smoke is held back while people move past.
The gap beside the leaf is kept to 4 mm, so the leaf swings free and the seal can close the opening when the leaf shuts. When the heat nears 200 to 250 degrees the intumescent seal swells to close the gap.
Locks, readers and the college team: who opens which door
Staff move from the entrance through the corridors to the workshops and back, and every leaf on that route opens for staff and stays shut for the students after hours. Beside each leaf on the route sits a reader, and it opens for the passes the list names. The lock the key turns is named in the fire door hardware guide.
The readers, releases and wiring beside a leaf are set out in the door entry systems guide.
Beside each door on the order sits the answer for the night the power fails, so every leaf knows whether it opens or stays shut when the supply goes. A door with no answer beside it leaves the staff to guess on the night the answer matters most.
The college order: every leaf on one list
One list carries the whole college, a line for every door with the leaf, the grade, the lock and the closer beside it, so the door that arrives is the door the classrooms, the workshops and the office need. A list that names one leaf for the whole college leaves the fitter guessing which room takes which grade, and a leaf in the wrong room guards the wrong thing.
Before the order is sent, the quotation is walked through door by door against the schedule, so no door goes out without a figure beside it, because a figure that never made it onto the quotation still turns up on the invoice, and a part ordered on its own after the doorset costs more than the same part ordered with the doorset. The how to specify security doors guide covers the columns the schedule must carry, and the security door cost factors guide explains how a higher grade moves the figure.
College doors are tried through the week, a few leaves each day, so none goes untried for long: the entrance at opening, the workshop door before the first lesson, and the cash room door at closing. Any leaf that drags, any closer that has lost its pull and any seal out of its groove goes in the record against its own door on the day it is found, with the part and the date beside it. What a visit should look for is set out in the fire door inspection checklist, and the doors that must hold both fire and forced entry are covered in the security door maintenance checklist.
| Position | Door | Grade | What to check |
|---|---|---|---|
| Entrance | Glazed leaf | LPS 1175 B3 | Leaf, glass, closer |
| Classroom corridor | Steel leaf | LPS 1175 C5 | Leaf, lock, seals |
| Workshops | Steel leaf | LPS 1175 C5 | Leaf, lock, seals |
| Office | Steel leaf | LPS 1175 C5 | Leaf, lock, reader |
| Cash room | Steel leaf | LPS 1175 D10 | Leaf, lock, reader |
| Plant room | Steel leaf | LPS 1175 C5 | Leaf, closer, lock |
On a college the grade, the period and the lock decide together whether the classrooms, the workshops and the office hold, so all three sit on the same list before the order goes out.
What grade should a college door carry?
The grade follows the room behind the leaf: B3, C5 or D10 to LPS 1175, with the cash room taking a higher category than the entrance beside it.
Can one leaf hold fire and forced entry?
Yes, a leaf that went through the fire test and the forced entry test on the same doorset carries one report for both jobs.
Do college doors need access control?
The doors behind the entrance take a reader beside the leaf, so the leaf opens for staff and stays shut for the students after hours.
What period should a college door carry?
A college door takes FD30 or FD60, proved to EN 1634-1, and the letters beside the minutes say what the leaf held back. The period follows the room the leaf guards.
Who checks the college doors?
The caretaker walks the round that covers every door, and the record of each visit stays with the college file.
Get a free quote
Related
More in guides for specifiers
Products
One supplier for the whole building envelope
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.