Certified physical security

ArxBridge
Steel door sample in a security test frame with an assessor in a UK test laboratory

ArxBridge

College Security Doors

A college guards classrooms, workshops and offices behind its doors, so each leaf takes the grade the room behind it demands, from entrance to plant room.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed across the UK
Prefer to talk?+44 7352 267239

Get a free project quote

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

A college is a set of classrooms, workshops and offices under one roof, and the doors between those parts decide what stays where it belongs. The corridors hold the students, the workshops hold the tools, and the offices hold the records, so each door takes its proof from the room behind it.

LPS 1175 sets the grade on a college door, and the category follows the value behind the leaf. Issue 8.2, dated September 2024, names three categories: B3 at three minutes, C5 at five and D10 at ten. The entrance takes the lowest, the classroom corridors take the middle one, and the cash room takes the highest.

A college follows the same rules as any other education building, and the fire door regulations schools guide covers the fire rules for school buildings, while the university security doors guide covers the doors of a university. The college order names every door in the building, with the grade and the lock beside each one, so the door that arrives is the door the room needs.

  • LPS 1175 B3 / C5 / D10Forced entry grades to Issue 8.2
  • Classroom corridorsWhere the grade rises
  • FD30 / FD60Fire periods to EN 1634-1
  • One listEvery college door named

Classrooms, workshops and offices: one college, three grades

A college splits into three parts, and the grade follows what each part holds. The classrooms hold the students, the workshops hold the tools and the materials, and the office holds the fees and the records, so each part takes the doors its work demands.

The entrance takes the doors the students walk through all day, and each leaf must open for a student with books in hand and shut behind them on its own. The workshops take the doors the students never open alone, and each leaf must hold against the attack the tools behind it invite.

Every opening in the college is written down before any leaf is ordered, with the leaf it takes and the grade beside it. A leaf with no line on that list may be fitted to the wrong room, guarding the wrong thing.

The entrance and the corridors: the leaves students pass

The entrance leaf opens for every student who arrives and holds an intruder out once the college closes, and its leaf, frame and lock are proved as one doorset, with the report naming all three.

A closer on the entrance leaf brings it home after every student who passes, because a leaf left standing open guards nothing. The closer is set so the leaf returns to the frame without a slam, and the pull is checked by opening the leaf and letting it go.

Glazing in the entrance leaf lets the staff see who stands outside before the leaf opens, and the pane carries the same proof as the leaf beside it. What the glass itself costs is worked through in the fire rated glass cost guide, and the bead and the fixings that hold the pane are named in the test report.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Classroom corridors: the doors between lessons

The classroom corridor runs past every room in the college, and the leaf that guards it takes the grade the value behind it demands. A classroom corridor leaf takes C5, because the equipment behind it is worth the minutes it takes to break through, and the leaf must hold until the alarm is answered.

The corridor takes a lock the college team controls, because the students must never pass it alone after hours. A leaf that guards the corridor takes C5, while the cash room beside it takes D10 and the entrance takes B3.

The corridor needs a leaf that shuts out the noise as well as an intruder, because the sound of lessons must not carry from room to room. The leaf takes seals round its edges and a closer that brings it home after every member of staff who passes.

One doorset on the corridor can carry both proofs at once, because the corridor needs fire held back and an intruder held out. EN 1634-1 gives the fire proof in minutes and letters, E, EW and EI from 30 to 120, and LPS 1175 gives the forced entry proof in B3, C5 and D10. Both proofs are run on the same leaf, frame and seals, so a single report holds them both. How one doorset carries both proofs is worked through in the fire and security doors dual certification guide.

Workshops and stores: where the tools and materials wait

Behind the classrooms, the workshops hold the tools the students will need next, and the leaf takes the grade the value behind it demands. C5 suits the workshops, because the tools behind it justify the minutes it takes to break through, and the leaf must hold until the alarm is answered.

The stores beside the workshops take the same care, because the materials and the spares sit behind their doors. Their leaf takes a lock the tutor controls, and the doorset is proved as one piece, leaf, frame and lock together, with the report naming each part.

The college plant room holds the services that keep the building open, and the leaf that guards it takes the grade the value behind it demands. A plant room leaf takes C5, because the boards and the plant behind it are worth the minutes it takes to break through. The plant room door requirements guide sets out what the plant room leaf must do.

The office and the cash room: where the fees and records sit

No room in the college takes a higher grade than the cash room, because the fees sit behind its leaf. Its leaf, frame, fixings and lock are proved as one doorset, and the test report names each part, so the door that arrives is the door that was proved.

D10 suits the cash room, because it must hold longest, while the corridor beside it takes C5 and the entrance takes B3. Drawings drawn before Issue 8 name the same three categories SR2, SR3 and SR4, and the order carries the new name beside the old one so the fitter is not left guessing.

The office beside the cash room takes the same care, because the records and the keys sit behind its doors. An office leaf takes C5, and the lock on it takes the same key as the cash room, so the staff who work the office can open both without carrying two keys. What breaks a rating once a door is fitted is named in the keeping an LPS 1175 rating valid guide.

The leaf that holds fire and forced entry together

One college leaf can hold both proofs, because the classrooms ask for fire held back while the cash room asks for an intruder held out. EN 1634-1 proves the fire side in E, EW and EI with minutes from 30 to 120, and LPS 1175 proves the forced entry side in B3, C5 and D10, with the leaf, the frame and the seals facing both tests together so one report holds both proofs. How one doorset carries both proofs is worked through in the fire and security doors dual certification guide.

The period on a college door follows the room behind it, because the classrooms, the workshops and the office put different loads behind each leaf, while the grade follows the value behind it. The minutes run from 30 to 120 beside letters that name what stayed back: flames on their own, flames with some heat, or flames with the heat as well. A route door carries a smoke rating beside the fire period, proved to BS EN 1634-3, with Sa for smoke at room temperature and S200 for smoke at 200 degrees. The smoke control doors guide covers how smoke is held back while people move past.

The gap beside the leaf is kept to 4 mm, so the leaf swings free and the seal can close the opening when the leaf shuts. When the heat nears 200 to 250 degrees the intumescent seal swells to close the gap.

Locks, readers and the college team: who opens which door

Staff move from the entrance through the corridors to the workshops and back, and every leaf on that route opens for staff and stays shut for the students after hours. Beside each leaf on the route sits a reader, and it opens for the passes the list names. The lock the key turns is named in the fire door hardware guide.

The readers, releases and wiring beside a leaf are set out in the door entry systems guide.

Beside each door on the order sits the answer for the night the power fails, so every leaf knows whether it opens or stays shut when the supply goes. A door with no answer beside it leaves the staff to guess on the night the answer matters most.

The college order: every leaf on one list

One list carries the whole college, a line for every door with the leaf, the grade, the lock and the closer beside it, so the door that arrives is the door the classrooms, the workshops and the office need. A list that names one leaf for the whole college leaves the fitter guessing which room takes which grade, and a leaf in the wrong room guards the wrong thing.

Before the order is sent, the quotation is walked through door by door against the schedule, so no door goes out without a figure beside it, because a figure that never made it onto the quotation still turns up on the invoice, and a part ordered on its own after the doorset costs more than the same part ordered with the doorset. The how to specify security doors guide covers the columns the schedule must carry, and the security door cost factors guide explains how a higher grade moves the figure.

College doors are tried through the week, a few leaves each day, so none goes untried for long: the entrance at opening, the workshop door before the first lesson, and the cash room door at closing. Any leaf that drags, any closer that has lost its pull and any seal out of its groove goes in the record against its own door on the day it is found, with the part and the date beside it. What a visit should look for is set out in the fire door inspection checklist, and the doors that must hold both fire and forced entry are covered in the security door maintenance checklist.

Position Door Grade What to check
Entrance Glazed leaf LPS 1175 B3 Leaf, glass, closer
Classroom corridor Steel leaf LPS 1175 C5 Leaf, lock, seals
Workshops Steel leaf LPS 1175 C5 Leaf, lock, seals
Office Steel leaf LPS 1175 C5 Leaf, lock, reader
Cash room Steel leaf LPS 1175 D10 Leaf, lock, reader
Plant room Steel leaf LPS 1175 C5 Leaf, closer, lock

On a college the grade, the period and the lock decide together whether the classrooms, the workshops and the office hold, so all three sit on the same list before the order goes out.

What grade should a college door carry?

The grade follows the room behind the leaf: B3, C5 or D10 to LPS 1175, with the cash room taking a higher category than the entrance beside it.

Can one leaf hold fire and forced entry?

Yes, a leaf that went through the fire test and the forced entry test on the same doorset carries one report for both jobs.

Do college doors need access control?

The doors behind the entrance take a reader beside the leaf, so the leaf opens for staff and stays shut for the students after hours.

What period should a college door carry?

A college door takes FD30 or FD60, proved to EN 1634-1, and the letters beside the minutes say what the leaf held back. The period follows the room the leaf guards.

Who checks the college doors?

The caretaker walks the round that covers every door, and the record of each visit stays with the college file.

Specifying doors for a college?Send the door list and the grade each room must hold for a tested door quotation.
Get a free quote

Related

More in guides for specifiers

10 mistakes when specifying certified security doors 10 steps to specify an LPS 1175 door Acceptance and Snagging of a Security Door or Barrier Job Access Control Doors Acoustic Doors: Ratings and Specification After a Forced Entry Attempt: Checking a Security Door Airport Security Doors Anti-Ligature Doors for Mental Health Wards Anti-Ram Bollards Anti-ram gates and barriers: protecting vehicle entrances Arcade Security Doors Explained Automatic Doors Automatic Gates Cost Factors Automatic Vehicle Barriers Ballistic Panels Bank Security Doors Bingo Hall Security Doors Explained Blast doors: glazed vs solid and how they are rated Blast protection window film: what it does and what it cannot do Blast resistant windows: what drives the cost and how to specify them Bollard Cost Factors Explained Bollard regulations in the UK: spacing, height and depth Bookmaker Security Doors Explained Builders Merchant Security Doors Bullet Resistant Glass Cost Factors Bullet resistant glass ratings explained: BR1 to BR7 and SG classes Bullet resistant vs bulletproof glass: what the difference means Buying Security Doors and HVM Through Public Frameworks Car Park Security Doors Explained Car Showroom Security Doors Casino Security Doors Explained CDM 2015 Duties When Security Doors, Shutters or HVM Are Installed Cinema Security Doors Cleanroom Doors Cold Store Doors Commissioning, Handover and the O&M Manual for Security Doors and HVM Communal entrance doors for flats: Secured by Design and what to specify Community Centre Security Doors Control Room Doors Court Security Doors Crash Rated Fences and HVM Fencing Explained Data centre physical security: doors, glazing, HVM and shielding by zone Dental Practice Security Doors Depot Security Doors Explained Door Entry Systems Due Diligence When Selecting Vehicle Security Barriers Emergency Exit Doors EMP Shielding Cost Factors Explained Exhibition Centre Fire Door Rules Exhibition Centre Security Doors Factory Security Doors Faraday cage vs RF shielded room: what a business needs FB4 vs FB6 vs FB7: how to choose a ballistic rating Fire and security doors: how dual certification works Fire Compartmentation Fire Curtains Fire Door Certification Fire Door Closers Explained Fire Door Cost Factors Fire Door Duties of the Accountable Person Fire Door Gaps Fire Door Hardware Explained Fire door inspection checklist for steel and timber doors Fire Door Maintenance Fire Door Regulations Care Homes Fire Door Regulations for A and E Departments Fire Door Regulations for Airports Explained Fire Door Regulations for Bowls Clubs Fire door regulations for commercial buildings in the UK Fire Door Regulations for Dialysis Centres Fire Door Regulations for Hockey Clubs Fire Door Regulations for Hospitals Explained Fire Door Regulations for Offices Explained Fire Door Regulations for Operating Theatres Fire Door Regulations for Retail Explained Fire Door Regulations for Schools Explained Fire Door Regulations for Snooker Clubs Fire Door Regulations for Stadiums Fire Door Regulations for Student Accommodation Fire Door Regulations for Warehouses Fire Door Regulations Leisure Centres Fire Door Regulations Restaurants Fire Door Remediation Programme for Housing Providers Fire Door Rules for Badminton Clubs Fire Door Rules for Bingo Halls Fire Door Rules for Bookmakers Fire Door Rules for Bowling Alleys Fire Door Rules for Car Parks Fire Door Rules for Car Showrooms Fire Door Rules for Cinemas Fire Door Rules for Climbing Centres Fire Door Rules for Colleges Fire Door Rules for Community Centres Fire Door Rules for Cricket Clubs Fire Door Rules for Dental Practices Fire Door Rules for Depots Explained Fire Door Rules for Golf Clubs Fire Door Rules for GP Surgeries Fire Door Rules for Gyms Explained Fire Door Rules for Ice Rinks Fire Door Rules for Maternity Units Fire Door Rules for Mental Health Units Fire Door Rules for Museums Fire Door Rules for Oncology Units Fire Door Rules for Opticians Fire Door Rules for Pawnbrokers Fire Door Rules for Petrol Stations Fire Door Rules for Pharmacies Fire Door Rules for Ports Fire Door Rules for Post Offices Fire Door Rules for Prisons Fire Door Rules for Rehabilitation Centres Fire Door Rules for Self Storage Fire Door Rules for Shopping Centres Fire Door Rules for Squash Clubs Fire Door Rules for Supermarkets Fire Door Rules for Swimming Pools Fire Door Rules for Tennis Clubs Fire Door Rules for Theatres Fire Door Rules for UK Arcades Fire Door Rules for UK Casinos Fire Door Rules for UK Hospices Fire Door Rules for Walk-in Centres Fire Door Signage Fire Door Vision Panels Fire Doors and Gateway 2 in Higher-Risk Buildings Fire Rated Glass Cost Explained Fire Rated Sliding Doors Explained Fire Rated Windows Cost Factors Fire Rated Windows Explained Fire Safety Enforcement Notices and Fire Doors: What the Responsible Person Must Do Flat Entrance Doors: PAS 24 and Fire Rated Forced Entry vs Ballistic vs Blast: Which Rating a Site Needs Garage Security Doors Explained Gate Automation Explained Golden Thread Records for Fire Doors GP Surgery Security Doors Explained Gym Security Doors Explained High Speed Doors HMO Fire Doors Hospice Security Doors Explained Hospital Security Doors: Wards, A&E, Plant Hospital Security Gates Hotel Fire Doors Hotel Security Doors How to choose HVM bollards: fixed, shallow mount, removable and automatic How to keep an LPS 1175 door rating valid after installation How to Specify Fire Doors in a Housing Tender How to specify security doors: a checklist for architects How to Verify a Secured by Design Listing How to Verify an LPS 1175 Certificate on Red Book Live How to Write an Operational Requirement for Physical Security HVM planters and street furniture: protection that blends in In-Service Care of Vehicle Security Barriers Installation Handover: LPS 1175 Doors and PAS 68 Barriers Intumescent Seals ISO 16933 explained: EXV and SB classes and hazard ratings ISO 22343 vehicle security barriers explained Keeping a Dual-Certified Fire and Security Door Valid in Service Laboratory Security Doors Layered Security for a Site: Deter, Detect, Delay, Mitigate, Respond Lead Times and Programme Risks for LPS 1175 Doors Leisure Centre Security Doors Library Security Doors Listed Building Fire Doors Loading Bay Doors Explained Lockdown and Access Control Hardware on an LPS 1175 Door LPS 1175 Gates and Grilles Explained LPS 1175 Issue 8 explained: from SR1 to SR8 to A1 to H20 LPS 1175 Roller Shutters LPS 1175 vs ASTM F2781 and Other US Ratings Explained LPS 1175 vs EN 1627: how UK and European burglar resistance ratings compare LPS 1175 vs PAS 24: which security standard does your door need? LPS 1175 Windows and Walling Explained Martyn’s Law and Places of Worship: What a Buyer Checks for Doors and Entry Control Martyn’s Law Enhanced Tier: Physical Measures and the Specifier Brief Martyn’s Law Standard Tier: Procedures, Doors and Shutters Martyn’s Law Timeline and the SIA Regulator Martyn’s Law: what premises must do and which physical measures to consider Master Key Systems MRI and RF shielded rooms: how they work and what to specify Museum Security Doors NPSA Catalogue of Security Equipment (CSE) Explained NPSA Forced Entry and Blast Guidance for Government Sites NPSA Guidance on Lockdown and Marauding Attack: What It Asks of Doors and Entrances Office Security Doors Optician Security Doors Explained Panic Hardware PAS 24 requirements for doors and windows explained PAS 68 Bollard Foundations Explained PAS 68 bollards: ratings, spacing and cost factors PAS 68 vs IWA 14 vs ISO 22343: hostile vehicle mitigation standards explained Pawnbroker Security Doors Explained Pedestrian Gates Petrol Station Security Doors Pharmacy Security Doors Planning Permission for Security Shutters, Gates and Bollards on Commercial Premises Plant room doors: fire, security and ventilation requirements Plant Room Fire Doors Port Security Doors Post Office Security Doors Explained Powder coating vs galvanising vs paint for steel Preliminary Market Engagement for Security Doors and HVM Prison Security Doors Programming a Security Door and Barrier Package on a Live Site Public-Sector Tender Response Checklist for Security Door and HVM Supply Reading a PAS 24 and SBD Door Test Report Regulation 38 Fire Safety Information at Handover for Fire-Rated Security Doorsets Replacing Security Doors in an Occupied Building Restaurant Security Doors Retail Security Doors Revolving Doors RF shielding standards and how shielded rooms are tested Rising Bollard Cost Factors Road Blocker Cost Factors Explained Road Blockers Explained Roller Shutter Cost Factors: What Drives the Price Roller shutter regulations in the UK: safety and maintenance Safe room and panic room doors: specification basics Safety Duties for Powered Doors, Gates and Barriers on Commercial Sites School Security Doors Sectional Doors Secured by Design explained: is it mandatory for doors? Secured by Design vs NPSA vs LPCB: Which One You Need Security Door Locks Security Door Maintenance Checklist Security Doors and Access for Everyone: What Approved Document M Asks Security Doors for A and E Departments Security Doors for Badminton Clubs Security Doors for Bowling Alleys Security Doors for Bowls Clubs Security Doors for Climbing Centres Security Doors for Cricket Clubs Security Doors for Dialysis Centres Security Doors for Golf Clubs Security Doors for Hockey Clubs Security Doors for Ice Rinks Security Doors for Maternity Units Security Doors for Mental Health Units Security Doors for Oncology Units Security Doors for Operating Theatres Security Doors for Rehabilitation Centres Security Doors for Snooker Clubs Security Doors for Squash Clubs Security Doors for Swimming Pools Security Doors for Tennis Clubs Security Doors for Walk-in Centres Security Doors West Midlands Explained Security Fencing Security Gates Cost Factors Explained Security shutters vs high performance roller doors Security shutters vs retractable grilles: which suits retail and commercial openings? Security Turnstiles Explained Security Window Film Security Windows for Schools Explained Self Storage Security Doors Server Room Doors Explained Shopping Centre Security Doors Smoke Control Doors Explained Smoke Curtains Specification Mistakes When Mixing LPS 1175, PAS 24 and SBD in One Tender SR2 vs SR3 vs SR4 security doors: choosing the right LPS 1175 level Stadium Security Doors Steel Door Frames Steel vs aluminium security doors: strength, ratings and looks Steel vs timber fire doors: which suits your building? Student Accommodation Security Doors Substation doors: security, ventilation and specification Supermarket Security Doors Telescopic Bollards Tender Evaluation Criteria and Scoring for Security Doors and HVM The Scope of a Maintenance Contract for Security Doors and Barriers Theatre Security Doors Thermal and Weather Performance of External Security Doorsets Thermally broken steel security doors: U-values and certification Traffic Calming as Hostile Vehicle Mitigation Transport hub security requirements Turnstile Cost Factors Explained Turnstile vs speed gate vs security portal: choosing entrance control Types of security doors for commercial buildings University Security Doors Explained Vehicle Dynamics Assessment: What It Tells the Buyer Before a Barrier Is Specified Warehouse Security Doors Explained Warehouse Security Gates Warranty, Defects Liability and Guarantees for Security Doors and Barriers What affects the cost of a bullet resistant door What affects the cost of a high-security door in the UK Window Security Bars View all →

Products

One supplier for the whole building envelope

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.