Certified physical security

ArxBridge
Installer checking the seal of navy steel fire-rated doors in a UK office corridor

ArxBridge

Golden Thread Records for Fire Doors

The golden thread is the digital record of a building's safety information. What it must hold for fire doors, who keeps it, and what passes at handover.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed across the UK
Prefer to talk?+44 7352 267239

Get a free project quote

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

The golden thread is the digital record of a building’s safety information, kept from design through construction and into occupation, and for fire doors it is the record that proves each door is the one the fire strategy names, fitted the way it was tested.

  • Digital recordKept electronically, not on paper files
  • Single source of truthOne record every duty holder works from
  • Whole lifeFrom design to occupation and beyond
  • Shared on requestTo the regulator, other accountable persons and residents

What the golden thread is

The golden thread is the name the government gives to the information about a building that must be kept as a digital record. It must be kept by a client, principal designer or principal contractor on a project that involves a higher-risk building, and by an accountable person or principal accountable person for a high-rise residential building. Keeping it helps the duty holder comply with the law and manage building safety. The government’s golden thread guidance sets out the duties in full.

A higher-risk building has at least 7 storeys or is at least 18 metres high, and has at least 2 residential units or is a hospital or a care home. A higher-risk building with at least 2 residential units must be registered with the regulator before people live there. The thread is not a single document and not a folder of certificates. It is a record-keeping system that holds the information in a form people can use, secure from unauthorised access, available when needed, and written in plain English.

Who keeps it, and when

During design and construction the client keeps the information, the principal designer captures and keeps the design information up to date, and the principal contractor uses the client’s record-keeping system. When the building is occupied, the accountable persons take the record over and keep it for as long as the building stands.

At the end of construction the client must demonstrate that the information has been given to the principal accountable person or the accountable person for a high-rise residential building, and to the responsible person for any non-residential parts. The person who receives it must confirm receipt and that it is in a format they can use. A thread that arrives as a pile of unlabelled files has not been handed over in any useful sense.

Phase Who keeps it Fire door records
Design and construction Client, principal designer, principal contractor Drawings, fire and emergency file, change control log
Handover Client to accountable person All approval and completion information, with access
Occupation Accountable person, principal accountable person Safety case report, checks, repairs, replacements

The record-keeping system should have version control so users can see any changes. Our fire door remediation programme guide sets out how a housing provider builds a door-by-door record a golden thread can carry forward.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

What the client must record during design and construction

As the client, the duty is to keep information that describes the building and shows how it complies with the building regulations, and how the work will be managed so the building that is built is the building that was set out. The information must be shared with every designer and contractor on the project, and the record-keeping system will hold the documents the building control approval application needs.

For fire doors, the design record is where the rating is fixed. The fire and emergency file, often called the fire strategy, must show how the work provides adequate means of escape and warning, inhibits fire spread, and gives the fire service reasonable access and facilities. The doors on those plans are the doors the golden thread must be able to prove: each opening, the rating it carries, and the evidence behind it. Our fire door certification guide covers the certificate and test evidence a doorset should show.

A golden thread is only as strong as its weakest entry. One fire door with no certificate, no label and no fitting record is a gap the next owner and the regulator will fall through.

Handover: what passes to the accountable person

When the building work is finished, the client must apply for a completion certificate, and demonstrate that the information about the building has been passed on to the person who will hold it in occupation, and to the responsible person for non-residential parts. The information handed over includes all of the information used to apply for building control approval, the completion certificate itself, access and control of the building information, and the relevant fire safety information for the responsible person.

The approval information includes the drawings, the compliance statement and the fire and emergency file, and the completion information adds the as-built record: what was actually fitted, where, and with what evidence. If the doors fitted differ from the doors approved, the handover must show the controlled change that approved the difference, with the evidence behind it.

What the accountable person keeps in occupation

In occupation, both the accountable person and the principal accountable person must keep information about the building and manage the record-keeping system that stores it, including the health and safety file, the safety case report, the residents’ engagement strategy and the mandatory occurrence reporting system. Where they have them, they should also keep information about refurbishments, information from previous owners including inspection reports and maintenance records, and what standard the building was built to.

That information helps the accountable person assess and manage building safety risks for the parts they are responsible for, and it supports the safety case report. The accountable person must be able to show how they assess and manage building safety risks, which include the spread of fire and structural failure, and understand the fire strategy for the parts they are responsible for. Our fire door maintenance guide covers the checks that keep the rating honest over the years.

Fire doors in the thread: the records that matter

For each fire door, the thread should hold the doorset certificate, the label on the leaf, and the evidence behind the rating. It should hold the record of the fitting, and the record of every check, repair and replacement since, door by door, with the date and the finding. The government’s safety case report guidance says the report should show that fire doors are in place in necessary locations, and provide evidence that fire doors and door closers are regularly inspected.

Where an accountable person carries out a fire door survey, the safety case report should include the surveyor’s competence, the significant findings, and the accountable person’s response. A survey that finds a closer that no longer shuts a stair door, with no recorded response and no re-inspection, is a thread with a hole in it. Our fire door inspection checklist lists the points to check on a single door.

Sharing the thread, and keeping it up to date

The information must be provided on request to the Building Safety Regulator, to other accountable persons, and to residents or owners of residential units in the building. A resident who asks what the fire doors in their stair are rated for should be able to get an answer from the record, not from memory.

Every change to a door, every repair, every replacement and every survey finding should be recorded when it happens, with version control so users can see what changed and when. The system must stay secure, available for authorised access, and compliant with data protection law. A thread that is accurate on the day of handover and out of date a year later is no longer a single source of truth. Our fire compartmentation guide sets out how doors, walls and seals work together to hold fire back.

Is the golden thread a single document?

No. It is a digital record-keeping system that holds the building’s safety information, with version control so users can see changes. It holds the health and safety file and the safety case report, plus the residents’ engagement strategy and the system for mandatory occurrence reporting.

Who can ask to see the golden thread?

The Building Safety Regulator, other accountable persons for the building, and residents or owners of residential units can ask for the information on request. The accountable person must provide it in a format the person asking can use.

What happens to the thread when the building changes hands?

The information passes to the new accountable person, who must confirm they have it and can use it. A thread that arrives incomplete leaves the new accountable person unable to show how the building’s fire doors were specified or tested.

Does every fire door need its own record?

Yes, in practice. The thread should hold the certificate, label and test evidence for each doorset, the fitting record, and a dated record of every check, repair and replacement. The safety case guidance asks for evidence that fire doors and closers are regularly inspected.

What if the old records are missing?

Say so in the record. The safety case guidance says that where information has not been found, the report should explain what was done to try and find it.

Ready to build the record for your building?Send the door schedule, the certificates you hold and the rating for each opening.
Contact us for a free quote

Related

More in guides for specifiers

10 mistakes when specifying certified security doors 10 steps to specify an LPS 1175 door Acceptance and Snagging of a Security Door or Barrier Job Access Control Doors Acoustic Doors: Ratings and Specification After a Forced Entry Attempt: Checking a Security Door Airport Security Doors Anti-Ligature Doors for Mental Health Wards Anti-Ram Bollards Anti-ram gates and barriers: protecting vehicle entrances Arcade Security Doors Explained Automatic Doors Automatic Gates Cost Factors Automatic Vehicle Barriers Ballistic Panels Bank Security Doors Bingo Hall Security Doors Explained Blast doors: glazed vs solid and how they are rated Blast protection window film: what it does and what it cannot do Blast resistant windows: what drives the cost and how to specify them Bollard Cost Factors Explained Bollard regulations in the UK: spacing, height and depth Bookmaker Security Doors Explained Builders Merchant Security Doors Bullet Resistant Glass Cost Factors Bullet resistant glass ratings explained: BR1 to BR7 and SG classes Bullet resistant vs bulletproof glass: what the difference means Buying Security Doors and HVM Through Public Frameworks Car Park Security Doors Explained Car Showroom Security Doors Casino Security Doors Explained CDM 2015 Duties When Security Doors, Shutters or HVM Are Installed Cinema Security Doors Cleanroom Doors Cold Store Doors College Security Doors Commissioning, Handover and the O&M Manual for Security Doors and HVM Communal entrance doors for flats: Secured by Design and what to specify Community Centre Security Doors Control Room Doors Court Security Doors Crash Rated Fences and HVM Fencing Explained Data centre physical security: doors, glazing, HVM and shielding by zone Dental Practice Security Doors Depot Security Doors Explained Door Entry Systems Due Diligence When Selecting Vehicle Security Barriers Emergency Exit Doors EMP Shielding Cost Factors Explained Exhibition Centre Fire Door Rules Exhibition Centre Security Doors Factory Security Doors Faraday cage vs RF shielded room: what a business needs FB4 vs FB6 vs FB7: how to choose a ballistic rating Fire and security doors: how dual certification works Fire Compartmentation Fire Curtains Fire Door Certification Fire Door Closers Explained Fire Door Cost Factors Fire Door Duties of the Accountable Person Fire Door Gaps Fire Door Hardware Explained Fire door inspection checklist for steel and timber doors Fire Door Maintenance Fire Door Regulations Care Homes Fire Door Regulations for A and E Departments Fire Door Regulations for Airports Explained Fire Door Regulations for Bowls Clubs Fire door regulations for commercial buildings in the UK Fire Door Regulations for Dialysis Centres Fire Door Regulations for Hockey Clubs Fire Door Regulations for Hospitals Explained Fire Door Regulations for Offices Explained Fire Door Regulations for Operating Theatres Fire Door Regulations for Retail Explained Fire Door Regulations for Schools Explained Fire Door Regulations for Snooker Clubs Fire Door Regulations for Stadiums Fire Door Regulations for Student Accommodation Fire Door Regulations for Warehouses Fire Door Regulations Leisure Centres Fire Door Regulations Restaurants Fire Door Remediation Programme for Housing Providers Fire Door Rules for Badminton Clubs Fire Door Rules for Bingo Halls Fire Door Rules for Bookmakers Fire Door Rules for Bowling Alleys Fire Door Rules for Car Parks Fire Door Rules for Car Showrooms Fire Door Rules for Cinemas Fire Door Rules for Climbing Centres Fire Door Rules for Colleges Fire Door Rules for Community Centres Fire Door Rules for Cricket Clubs Fire Door Rules for Dental Practices Fire Door Rules for Depots Explained Fire Door Rules for Golf Clubs Fire Door Rules for GP Surgeries Fire Door Rules for Gyms Explained Fire Door Rules for Ice Rinks Fire Door Rules for Maternity Units Fire Door Rules for Mental Health Units Fire Door Rules for Museums Fire Door Rules for Oncology Units Fire Door Rules for Opticians Fire Door Rules for Pawnbrokers Fire Door Rules for Petrol Stations Fire Door Rules for Pharmacies Fire Door Rules for Ports Fire Door Rules for Post Offices Fire Door Rules for Prisons Fire Door Rules for Rehabilitation Centres Fire Door Rules for Self Storage Fire Door Rules for Shopping Centres Fire Door Rules for Squash Clubs Fire Door Rules for Supermarkets Fire Door Rules for Swimming Pools Fire Door Rules for Tennis Clubs Fire Door Rules for Theatres Fire Door Rules for UK Arcades Fire Door Rules for UK Casinos Fire Door Rules for UK Hospices Fire Door Rules for Walk-in Centres Fire Door Signage Fire Door Vision Panels Fire Doors and Gateway 2 in Higher-Risk Buildings Fire Rated Glass Cost Explained Fire Rated Sliding Doors Explained Fire Rated Windows Cost Factors Fire Rated Windows Explained Fire Safety Enforcement Notices and Fire Doors: What the Responsible Person Must Do Flat Entrance Doors: PAS 24 and Fire Rated Forced Entry vs Ballistic vs Blast: Which Rating a Site Needs Garage Security Doors Explained Gate Automation Explained GP Surgery Security Doors Explained Gym Security Doors Explained High Speed Doors HMO Fire Doors Hospice Security Doors Explained Hospital Security Doors: Wards, A&E, Plant Hospital Security Gates Hotel Fire Doors Hotel Security Doors How to choose HVM bollards: fixed, shallow mount, removable and automatic How to keep an LPS 1175 door rating valid after installation How to Specify Fire Doors in a Housing Tender How to specify security doors: a checklist for architects How to Verify a Secured by Design Listing How to Verify an LPS 1175 Certificate on Red Book Live How to Write an Operational Requirement for Physical Security HVM planters and street furniture: protection that blends in In-Service Care of Vehicle Security Barriers Installation Handover: LPS 1175 Doors and PAS 68 Barriers Intumescent Seals ISO 16933 explained: EXV and SB classes and hazard ratings ISO 22343 vehicle security barriers explained Keeping a Dual-Certified Fire and Security Door Valid in Service Laboratory Security Doors Layered Security for a Site: Deter, Detect, Delay, Mitigate, Respond Lead Times and Programme Risks for LPS 1175 Doors Leisure Centre Security Doors Library Security Doors Listed Building Fire Doors Loading Bay Doors Explained Lockdown and Access Control Hardware on an LPS 1175 Door LPS 1175 Gates and Grilles Explained LPS 1175 Issue 8 explained: from SR1 to SR8 to A1 to H20 LPS 1175 Roller Shutters LPS 1175 vs ASTM F2781 and Other US Ratings Explained LPS 1175 vs EN 1627: how UK and European burglar resistance ratings compare LPS 1175 vs PAS 24: which security standard does your door need? LPS 1175 Windows and Walling Explained Martyn’s Law and Places of Worship: What a Buyer Checks for Doors and Entry Control Martyn’s Law Enhanced Tier: Physical Measures and the Specifier Brief Martyn’s Law Standard Tier: Procedures, Doors and Shutters Martyn’s Law Timeline and the SIA Regulator Martyn’s Law: what premises must do and which physical measures to consider Master Key Systems MRI and RF shielded rooms: how they work and what to specify Museum Security Doors NPSA Catalogue of Security Equipment (CSE) Explained NPSA Forced Entry and Blast Guidance for Government Sites NPSA Guidance on Lockdown and Marauding Attack: What It Asks of Doors and Entrances Office Security Doors Optician Security Doors Explained Panic Hardware PAS 24 requirements for doors and windows explained PAS 68 Bollard Foundations Explained PAS 68 bollards: ratings, spacing and cost factors PAS 68 vs IWA 14 vs ISO 22343: hostile vehicle mitigation standards explained Pawnbroker Security Doors Explained Pedestrian Gates Petrol Station Security Doors Pharmacy Security Doors Planning Permission for Security Shutters, Gates and Bollards on Commercial Premises Plant room doors: fire, security and ventilation requirements Plant Room Fire Doors Port Security Doors Post Office Security Doors Explained Powder coating vs galvanising vs paint for steel Preliminary Market Engagement for Security Doors and HVM Prison Security Doors Programming a Security Door and Barrier Package on a Live Site Public-Sector Tender Response Checklist for Security Door and HVM Supply Reading a PAS 24 and SBD Door Test Report Regulation 38 Fire Safety Information at Handover for Fire-Rated Security Doorsets Replacing Security Doors in an Occupied Building Restaurant Security Doors Retail Security Doors Revolving Doors RF shielding standards and how shielded rooms are tested Rising Bollard Cost Factors Road Blocker Cost Factors Explained Road Blockers Explained Roller Shutter Cost Factors: What Drives the Price Roller shutter regulations in the UK: safety and maintenance Safe room and panic room doors: specification basics Safety Duties for Powered Doors, Gates and Barriers on Commercial Sites School Security Doors Sectional Doors Secured by Design explained: is it mandatory for doors? Secured by Design vs NPSA vs LPCB: Which One You Need Security Door Locks Security Door Maintenance Checklist Security Doors and Access for Everyone: What Approved Document M Asks Security Doors for A and E Departments Security Doors for Badminton Clubs Security Doors for Bowling Alleys Security Doors for Bowls Clubs Security Doors for Climbing Centres Security Doors for Cricket Clubs Security Doors for Dialysis Centres Security Doors for Golf Clubs Security Doors for Hockey Clubs Security Doors for Ice Rinks Security Doors for Maternity Units Security Doors for Mental Health Units Security Doors for Oncology Units Security Doors for Operating Theatres Security Doors for Rehabilitation Centres Security Doors for Snooker Clubs Security Doors for Squash Clubs Security Doors for Swimming Pools Security Doors for Tennis Clubs Security Doors for Walk-in Centres Security Doors West Midlands Explained Security Fencing Security Gates Cost Factors Explained Security shutters vs high performance roller doors Security shutters vs retractable grilles: which suits retail and commercial openings? Security Turnstiles Explained Security Window Film Security Windows for Schools Explained Self Storage Security Doors Server Room Doors Explained Shopping Centre Security Doors Smoke Control Doors Explained Smoke Curtains Specification Mistakes When Mixing LPS 1175, PAS 24 and SBD in One Tender SR2 vs SR3 vs SR4 security doors: choosing the right LPS 1175 level Stadium Security Doors Steel Door Frames Steel vs aluminium security doors: strength, ratings and looks Steel vs timber fire doors: which suits your building? Student Accommodation Security Doors Substation doors: security, ventilation and specification Supermarket Security Doors Telescopic Bollards Tender Evaluation Criteria and Scoring for Security Doors and HVM The Scope of a Maintenance Contract for Security Doors and Barriers Theatre Security Doors Thermal and Weather Performance of External Security Doorsets Thermally broken steel security doors: U-values and certification Traffic Calming as Hostile Vehicle Mitigation Transport hub security requirements Turnstile Cost Factors Explained Turnstile vs speed gate vs security portal: choosing entrance control Types of security doors for commercial buildings University Security Doors Explained Vehicle Dynamics Assessment: What It Tells the Buyer Before a Barrier Is Specified Warehouse Security Doors Explained Warehouse Security Gates Warranty, Defects Liability and Guarantees for Security Doors and Barriers What affects the cost of a bullet resistant door What affects the cost of a high-security door in the UK Window Security Bars View all →

Products

One supplier for the whole building envelope

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.