Fire Door Rules for Theatres
Theatres fill with a crowd, so the fire doors must hold the line and let people out: the periods, the escape routes and the doors a theatre order names.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A theatre fills with people who do not know the building, and the fire doors must do two jobs at once. The leaf must hold fire back for its period, and it must open for a crowd that has never walked the route before.
The doors and the rules travel together in a theatre, because the order that names the leaf must also name the period, the closer and the way out. A door ordered without the room it guards may land on the wrong opening, and a leaf fitted to the wrong room guards the wrong thing.
The rules for the shared parts of a public building are set out in the fire door regulations commercial buildings guide, and the doors that guard a venue are worked through in the types of security doors guide. A theatre order names every door in the venue, with the period and the hardware beside each one.
- FD30 / FD60Fire periods to EN 1634-1
- E / EW / EI 30-120What the letters beside the period mean
- EN 3 minimumCloser power on a fire door
- One listEvery theatre door named
The audience, the stage and the rules between them
A theatre divides into three parts, and the rules follow the parts. The auditorium holds the audience, the stage holds the performance, and the rooms behind the stage hold the people and the things the performance needs. A door between one part and the next must hold the line between them, so the fire stays on the side where it started and the people reach the way out.
The auditorium takes the doors that let a crowd in and out, and each leaf must open for people who have never seen the building before. The stage takes the doors that guard the scenery, the fly tower and the stores, and each leaf must hold fire back where the load is greatest.
The fire strategy names every opening in the building, with the door or the closure beside each one, and the order follows the strategy, not the other way round.
FD30 and FD60 in a theatre: the periods each part takes
The period on a theatre door follows the fire load behind the opening, not the size of the leaf. A door that guards a scenery store takes the period the fire load behind it demands, while a door on the auditorium escape route takes the period the way out needs, and the period on each door matches the opening it guards.
EN 1634-1 tests a doorset for fire resistance, and the result is a number of minutes with letters beside it. The number runs from 30 to 120, and the letters say whether the doorset stopped the flames alone, the flames with some of the heat, or the flames with the heat as well. The number and the letters travel together on the order, because a period without its letters names only half the proof.
The leaf grows heavier as the period grows, because the build that holds fire back for an hour takes more than the build that holds it for half an hour. A leaf proved to the shorter period on an opening that needs the longer one leaves the wall beside it holding a line the door cannot hold, and the fire moves to the weakest part.
The auditorium doors: the leaves a crowd leans on
The auditorium doors take the crowd in and out, and each leaf must open with one push from people who have never touched it before. The release on each leaf throws the latch with one push, and the leaf swings open even when the power has gone.
The bar across an escape door runs to BS EN 1125, and it must cover at least 60 percent of the leaf it sits on. The bar and the lock beside it must work as one, so the push that throws the latch does not fight the lock that holds the leaf.
The push a door needs is measured, not guessed. Under BS 8300 and Approved Document M the force stays below 30 N for the first 30 degrees of travel and below 22.5 N beyond it, and the auditorium leaves are tested to those figures. The leaves on a building that fills with a crowd are covered in the fire door regulations stadiums guide, and the fire door regulations leisure centres guide covers the doors on a leisure building.
The stage and the scenery store: the doors behind the curtain
The stage holds the scenery, the curtains and the rigging, and the fire load behind the stage doors is the greatest in the building. The doors that guard the stage take the longest period on the order.
A store door can carry two proofs on one leaf, because the room behind it needs both. The fire proof runs in E, EW and EI from 30 to 120 minutes under EN 1634-1, while the forced entry proof runs in B3, C5 and D10 to LPS 1175, holding three, five and ten minutes. The leaf, the frame and the seals go to the test as one doorset for both proofs, and the report names them all.
The fly tower takes a door that guards the height above the stage, and the leaf must hold fire back where the heat rises first. The loading bay takes a door wide enough for scenery, and the bay door takes a closer that pulls it shut after each load. The doors that guard a warehouse take the same care with their stores, and the fire door regulations warehouses guide sets out the periods for a building that holds stock.
Escape from a full house: the routes that must stay clear
A theatre fills with a crowd that must leave through routes it has never walked, so the way out matters more than the way in. Each door on the route must open with one push, without a key and without power.
The seals on the route doors are proved to BS EN 1634-3, Sa for smoke at room temperature and S200 for smoke at 200 degrees. The seal must close the gap round the leaf, because smoke moves faster than flame and reaches the people on the route before the fire does.
The doors on the same route take the same period, because the fire moves to the weakest part of the wall. A corridor door proved to a shorter period than the doors beside it leaves a hole in the line. The smoke control doors guide covers the doors that hold smoke back while people move past them.
| Position | Door | Period | What to check |
|---|---|---|---|
| Auditorium exit | Fire leaf | FD60 | Leaf, bar, closer |
| Stage door | Fire leaf | FD60 | Leaf, seals, lock |
| Scenery store | Fire leaf | FD60 | Leaf, lock, seals |
| Foyer | Glazed leaf | FD30 | Leaf, glass, closer |
| Plant room | Fire leaf | FD60 | Leaf, seals, gap |
The front of house doors: the entrance that takes the crowd
Front of house takes the doors the public sees, and they must hold their line while looking like part of the building. A glazed leaf lets light into the foyer and lets the staff at the door see who stands outside, and the pane beside the leaf takes the same proof as the leaf itself.
The room that holds the takings takes a leaf proved against the attack the room faces, and the grade on the order follows the risk behind the leaf, not the size of the opening. A leaf that guards cash takes a higher category than the leaf beside it that guards a corridor.
The public entrance must open for a crowd and shut behind it, and the closer on each leaf must pull it home after every person who passes through. A closer that has lost its pull leaves the leaf standing open. The fire door closers guide sets out the sizes and the fitting of closers, and the fire door regulations retail guide sets out the periods for the shared parts of a shop front.
Closers, seals and gaps: the parts a theatre wears out first
The closer on a theatre door works harder than the closer on any other door. The smallest power a fire door closer may take is EN 3 to BS EN 1154, and the closer is tested by opening the leaf and watching it shut on its own. A closer that no longer pulls the leaf home leaves the door standing open, and the seal in its groove holds nothing while the leaf stands open.
The gap round the leaf is held to 4 mm, wide enough for the leaf to swing and narrow enough for the seal to close. An intumescent seal swells at around 200 to 250 degrees, and a coat of paint over it holds it flat, so the seal cannot close the gap when the fire comes. The gap is measured on the round with the gauge, and a leaf that drags or a seal that has hardened is noted beside the door it belongs to.
The hinges take the weight of the leaf through every swing of the night, and a hinge that has worked loose lets the leaf sag until it drags on the floor. The hinges are tried on every visit, and the fixings are tightened before the leaf drops further. The lock the key turns is covered in the fire door hardware guide, and the doors that must hold both fire and forced entry are covered in the security door maintenance checklist.
The theatre door list: every leaf named before the order
The order for a theatre is one list, and each door in the venue takes a line of its own. The line names the leaf, the period, the hardware and the fitting beside the opening it closes. A list that names one leaf for every opening leaves the choice to the fitter, and a leaf chosen on site is a leaf without a proof.
Every line of the quotation is checked against that list before the order goes out, so no leaf, closer or seal is missed from the price. A part missed from the price still has to be bought, and fitting it to a door already in use costs more than ordering it with the building. The how to specify security doors guide sets out the columns the list needs, and the security door cost factors guide works through what each step up the scale adds to the price.
The round walks the auditorium, the stage, the dressing rooms and the plant room in turn, and tries each leaf as it passes. A leaf that will not shut, a gap that has opened since the last visit, or a bar that sticks is written down where it is found, with the door named beside it. The fire door inspection checklist names what each visit should look for.
A theatre door holds only as long as the period on its leaf and the way out behind it, so the period, the release and the closer must all sit on the same list.
What period should a theatre door carry?
FD30 or FD60 to EN 1634-1, following the fire load behind the leaf, with the letters E, EW or EI beside the number saying what the doorset held back.
Can one leaf hold fire and forced entry?
Yes, where the leaf, the frame and the seals went to the test together for both proofs, fire to EN 1634-1 and forced entry to LPS 1175.
Do theatre doors need panic hardware?
The doors on an escape route take a bar to BS EN 1125, covering at least 60 percent of the leaf, so the leaf opens for a crowd with one push.
What happens when the power fails?
The leaf on the way out must open without power, because the crowd behind it cannot wait for the power to come back. The leaf that guards cash or instruments stays shut when the power fails.
Who checks the theatre doors?
The person who runs the venue walks the round that covers every door, and each fault is noted beside the door it belongs to before the visit ends.