A pawnbroker holds cash, jewellery and pledged goods behind one small shop front, so each leaf takes the LPS 1175 grade that its room demands.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A pawnbroker shop keeps cash, jewellery and pledged goods in one small building, and the doors in that building draw a line between the counter where the public stands and the rooms where the value sits. The entrance takes the public in from the street, the counter keeps the public on one side of the till, and the cash office, the back office and the plant room sit behind the counter where callers never go.
LPS 1175 Issue 8.2, dated September 2024, grades a leaf by the minutes it stands against the tools the test names, and a pawnbroker leaf takes its grade from what waits behind it. B3 stands for three minutes, C5 stands for five minutes and D10 stands for ten minutes, and an old drawing may still call the same three leaves SR2, SR3 and SR4, so the order carries both names beside each leaf until the old drawings are replaced.
A pawnbroker is not a bank, because no vault stands behind its counter, and it is not an ordinary shop, because the goods behind its counter are pledged by callers and held for redemption. The bank security doors guide shows how a bank grades the doors round its cash, and the retail security doors guide shows how a shop grades the doors round its stock, while the leaves in a pawnbroker follow the till and the pledge counter that sit between them.
- B3 / C5 / D10Grades to LPS 1175 Issue 8.2
- Cash officeWhere D10 sits
- CounterWhere B3 sits
- One listEvery pawnbroker leaf named
Five openings in a pawnbroker shop: the grade each one carries
Five rooms make up a pawnbroker, and the grade follows what each room holds. The entrance takes the queue in, the counter holds the cash and the pledges the queue hands over, the cash office holds the takings and the goods awaiting redemption, the back office holds the keys and the redemption papers, and the plant room keeps the building running through the working day.
B3 sits on the entrance leaf and on the counter leaf, because both leaves stand in view of the queue all day and must resist a quick attempt while the staff can see them. The back office and the plant room take C5, because the keys, the papers and the plant behind those leaves need a longer hold than the entrance. The cash office takes D10, because the takings and the pledges behind it are the most portable value in the building and the leaf is shut and locked whenever no one is counting.
The order gives every opening its own line, with the leaf and the grade written beside it, so no leaf is hung on guesswork and no room ends up with a leaf that holds for the wrong number of minutes. The table names the five rooms with the grade and the minutes beside each one, so the fitter checks each leaf against its own line while it is hung.
| Room | Grade | Minutes | What to check |
|---|---|---|---|
| Entrance | B3 | 3 | Leaf, lock, closer |
| Counter | B3 | 3 | Leaf, lock, seals |
| Cash office | D10 | 10 | Leaf, lock, hinges |
| Back office | C5 | 5 | Leaf, lock, reader |
| Plant room | C5 | 5 | Leaf, lock, seals |
A leaf in the shop may need to hold fire as well as forced entry, and the two proofs sit in one report for the same doorset. EN 1634-1 counts the fire minutes from 30 to 120, with E for flames alone, EW for flames with part of the heat held back and EI for flames with the heat held back as well, while LPS 1175 Issue 8.2 of September 2024 names the grade in B3, C5 and D10. How the pair is proved on one leaf is shown in the fire and security doors dual certification guide, and what Issue 8.2 changed is set out in the LPS 1175 Issue 8 explained guide, while the SR2 vs SR3 vs SR4 guide puts the old names beside the new grades.
The street entrance takes B3 through a day of callers
Callers use the entrance leaf all day, and the closer on it must bring the leaf home after each person without a slam. A glazed panel in the leaf lets the staff at the till see who is coming in before the leaf opens, and the panel is proved with the leaf round it, with the glass, the bead and the fixings named together in the same report.
The entrance asks for three minutes because it stands in sight of the till through every hour the shop is open, and three minutes gives the staff time to shut the counter leaf and raise help. The entrance lock takes a key on the street side and a thumb turn on the shop side, so the last person out at closing can secure the leaf without a key in hand, and the first person in at opening uses the key from outside.
The street entrance opens for each caller and shuts behind them
The street entrance opens for every caller through the trading day, and the latch and the closer must shut the door behind each one, so the shop stays shut to the street between callers. A caller steps in and the door comes back on its closer before the next caller reaches it.
The latch carries the first part of that duty. It must catch each time the door is drawn to, and a latch that misses its keep lets the door stand ajar while the shop is busy, so the street can see straight in to the counter. The catch is heard as a click, and a latch that misses is put on the fault list the same day.
One key opens every door behind the counter, and it stays with the manager through the day, while the keys the counter staff carry stop at the counter and the back office. The master key systems guide sets out a plan where each key opens the rooms its holder works in and no room past them.
| Time of day | Door state | Who watches it |
|---|---|---|
| First caller | Opened, then drawn shut | Counter staff |
| Midday rush | Shut after each caller | Manager on the floor |
| Last caller | Shut, latch caught | Manager closing the shop |
To LPS 1175 Issue 8 the street entrance is B3, which holds for three minutes under the tools the test uses, and the LPS 1175 Issue 8 explained guide sets out what the issue changed and how each grade is proved. A B3 door at the front holds the street back for three minutes.
Keeping pace with a day of callers
The closer keeps pace by drawing the door home at the same speed after the first caller and after the hundredth, because a closer that slows through the day leaves the door ajar at the very hour the queue is longest. The closer is set so the door meets its frame without a slam.
A B3 door is heavy, and it hangs on hinges proved to BS EN 1935 through 200,000 cycles, with grade 13 proved under a 120 kg door and grade 14 proved under a heavier 160 kg door, so the bolt keeps meeting its keep through years of daily use. The steel door frames guide shows the frame carrying the door and its lock as one piece.
Once a month the manager takes the door list round the shop, trying each door, watching the closer draw it home, and noting a dragging door beside its own room on the day it turns up. The security door maintenance checklist guide runs through the checks that walk should make on each door.
The lock on the street entrance answers a key from outside and a thumb turn from inside, so the last person out can secure the door without hunting for a key. The security door locks guide sets out what the lock on a door like this one must do when the shop stands empty.
When the day ends the shop sends its room list to the healthcare doors quote, with the street entrance first and the cash office last.
Pledged goods behind the counter: a B3 leaf at the till
The counter leaf suits B3 because it stands in full view of the staff and the queue, and a leaf that is watched all day asks for three minutes rather than ten. Cash, jewellery and pledged goods pass over the counter while the leaf stays shut, and staff pass through it between the till, the printer and the cash office without letting the queue follow.
A serving hatch in the counter lets jewellery and cash pass without the leaf swinging, and LPS 2081 grades that hatch, with SRA at one minute and SRB at three minutes, so the hatch is ordered to the grade the counter leaf beside it carries. Both hatch grades are named on the LPS 2081 standard page, and EN 1627 runs its own grades from RC1 to RC6, so the LPS 1175 vs EN 1627 guide is the place where the two tests are set beside each other, with no claim that one equals the other.
The cash office door: D10 where takings and pledges are counted
The cash office holds the takings and the pledges that have not been redeemed, so its leaf takes D10, the longest hold LPS 1175 Issue 8.2 names. The leaf is proved with its frame, its fixings and its lock as one doorset, and the report beside it names ten minutes against the tools the test names.
Glass has no place on the cash office leaf, because a pane would let the corridor see the counting and give a hand a way to the lock, so the leaf is solid steel from edge to edge. The weight of a D10 leaf hangs on hinges proved to BS EN 1935, where grade 13 covers a leaf of 120 kg and grade 14 covers a leaf of 160 kg, and each grade is proved through 200,000 cycles, so the leaf keeps its line and the bolt keeps finding its keep through years of use.
Under TS 007, a cylinder rated 1 star and a handle rated 2 star combine into a 3 star set, and the pair is ordered together so the cylinder on the cash office leaf is the one the test saw beside its handle. The manager holds the key to the cash office, and the names that may open it are written on the list beside the leaf, so a leaf left standing open is shut at once and the name that left it open is asked why.
The cash office lock turns last, once the takings are counted
At closing the takings are counted behind the cash office leaf, and the lock is turned before the shutter comes down, so the counted money sits behind D10 through the night. The leaf is shut while the counting runs, because a leaf left open while money is counted is a leaf that guards nothing, and the count is finished before the shop empties. The pledges counted beside the takings are the goods nobody has redeemed, and they sit behind the same leaf as the money, because both are the most portable value in the building.
The cash office lock answers a key from the corridor and a thumb turn from inside, so the last person counting can secure the leaf without hunting for a key. The locks guide sets out what the lock on a leaf like this one must do when the room stands empty.
| Time | Leaf | State |
|---|---|---|
| Counting | Cash office | Lock turned, leaf shut |
| Closing | Street entrance | Key outside, thumb turn inside |
| Night | Counter leaf | Shut, queue gone |
One key opens every leaf behind the counter, and it stays with the manager through the day, while the keys the counter staff carry stop at the counter and the back office. The guide to master key systems sets out a plan where each key opens the rooms its holder works in and no room past them.
A D10 leaf is heavy, and it hangs on hinges proved to BS EN 1935 through 200,000 cycles, with grade 13 proved under a 120 kg leaf and grade 14 proved under a heavier 160 kg leaf, so the bolt keeps meeting its keep through years of daily use. TS 007 counts a 1 star cylinder beside a 2 star handle as a 3 star set, so the pair is ordered together and the test saw that cylinder beside that handle.
The grades B3, C5 and D10 are named in LPS 1175 Issue 8, with three, five and ten minutes of hold, and the guide to LPS 1175 Issue 8 explained sets out what the issue changed and how each grade is proved.
The takings stay behind D10 after the last caller leaves
The frame takes the weight of the leaf and the strain of the lock, and a frame that bends under force hands the leaf over with it. A frame ordered with the leaf is proved with it, so the report names the frame beside the leaf it carries. The guide to steel door frames shows the frame carrying the leaf and its lock as one piece.
Once a month the manager takes the door list round the shop, trying each leaf, watching the closer draw it home, and noting a dragging leaf beside its own door on the day it turns up. The security door maintenance checklist guide lists the checks that walk should make on each leaf.
The shop order runs from the room list. The healthcare doors quote page takes the rooms behind the counter one by one, so the cash office leaf and the lock that guards the takings stand on one line together.
Back office and plant room: C5 on the rooms that run the shop
The back office holds the keys to the other rooms and the papers that record each pledge, so its leaf takes C5 and is locked whenever the room stands empty, because a room left open gives any passer by the keys to the rest of the shop. A reader beside the back office leaf opens only for the cards the list names, so the room opens for the staff and stays shut for the public.
Boards and equipment in the plant room keep the lights, the till and the heating running, so the leaf on that room takes C5, because a stranger through that leaf reaches the boards that feed the whole shop. The plant room door requirements guide covers the leaves of a plant room in full, and the security doors for pharmacies guide shows how another small shop with locked rooms behind a counter grades its leaves.
Keys and cards: who opens which leaf in the shop
Behind the counter, each leaf opens to the cards and keys of the staff who work there, and no card held on the public side opens any of them. A key plan drawn under the master key systems guide gives each holder the rooms their work needs and no other room, and the security door locks guide names the lock that each leaf in the plan must carry.
The manager holds a key that opens every leaf behind the counter, and the counter staff hold keys that open only the counter and the back office. The 10 steps to specify an LPS 1175 door guide walks through the order from the first leaf to the last.
Glazed leaves at the counter: sight of the queue without an open leaf
Staff at the till watch the queue through glass in the entrance and counter leaves, so the leaves stay shut while the queue is still seen. That glass is proved as part of the leaf round it, with the pane, the bead and the fixings named in one report, because a pane ordered alone may not sit in the leaf the test saw.
A glazed leaf suits the entrance and the counter, and a solid leaf suits the cash office, because the watched rooms take glass and the unwatched room takes steel. The steel door frames guide names how the frame holds the leaf and the lock together, and the keeping an LPS 1175 rating valid guide names what can take a rating away once the leaf is hung.
The pawnbroker order: every leaf, its grade and its lock
One list carries the whole pawnbroker order, with a line for every opening that names the leaf, the grade, the lock and the closer beside it. A leaf with no line of its own may be hung where it does not belong, and a C5 leaf on the cash office holds for five minutes where the takings ask for ten.
Each month the shop manager takes the door list round the building and tries the leaves in turn, so every leaf is tried before the month is out. A leaf that drags, a bolt that misses its keep or a closer that leaves the leaf standing open is written against its own door on the day it is found, and the security door maintenance checklist names what the walk should cover.
The grade on a pawnbroker leaf follows the value behind it, so the leaf, the lock and the closer are ordered together and checked together against the room behind the leaf.
What grade should a pawnbroker entrance door carry?
B3 to LPS 1175 Issue 8.2, which holds for three minutes, because the entrance stands in view of the till and the queue all day.
What grade should a pawnbroker cash office door carry?
D10 to LPS 1175 Issue 8.2, which holds for ten minutes, because the cash office holds the takings and the pledges behind a shut leaf.
What grade should a pawnbroker counter door carry?
B3 to LPS 1175 Issue 8.2, because the counter leaf is watched by the staff and the queue through the day, and three minutes is the hold a watched leaf asks for.
Can one leaf hold fire and forced entry?
Yes, where the same doorset passed the fire test and the forced entry test, so the period and the grade are named in one report beside the same leaf.
Who checks the pawnbroker doors?
The shop manager walks the shop with the door list each month and tries the leaves in turn, so a fault is found and put right before the leaf is asked to hold.
Get a free quote