A master key system lets one key open many doors while a staff key opens only the doors its holder needs. The estate manager holds the key that opens the whole building, the cleaner holds the key that opens the rooms they clean, and the tenant holds the key that opens only their own flat.
The system is a hierarchy, not a pile of keys. Each door takes a cylinder that answers to its own key and to the keys above it, so the right key opens the right doors and no key opens a door it should not. A system planned on paper first works on the doors, and a system that grows one key at a time stops working.
The doors a keyed system guards are set out in the commercial buildings fire door regulations guide, and the fire door hardware guide covers the grades and the parts behind a working fire door.
- TS 007 3-starCylinder and handle sets
- BS EN 1935Hinge grades 13 and 14
- BS EN 1125Panic hardware for escape routes
- FD30 / FD60Fire resistance periods tested to EN 1634-1
One key, many doors: how a keyed system is put together
A keyed system starts with the doors, not with the keys. Each door on the estate is listed, the people who need it are named, and the keys are cut to match the list. The master key opens every door on the estate, the sub-master opens the doors on one floor or in one wing, and the individual key opens one door and no other.
The cylinder is the part that reads the key. A cylinder that answers to more than one key is pinned to accept each of them, and the pinning is set when the cylinder is made. A cylinder pinned for three keys cannot be changed by cutting a fourth key, because the pinning is fixed in the metal.
Plan the whole hierarchy before the first cylinder is ordered, because a system extended later has to be re-pinned, and re-pinning a building full of cylinders costs more than planning it once. The how to specify security doors guide sets out the columns a schedule needs, and the keying belongs on one of them.
The hierarchy: who opens which door, and who opens them all
The top of the hierarchy is the grand master key, held by the person who runs the estate. It opens every door, including the plant rooms, the stores and the rooms that hold the keys, and it should be kept in a safe when it is not in use.
Below it sit the sub-master keys, one for each floor, wing or department. A sub-master opens the doors in its own part of the building and no other, so the cleaner for the north wing cannot open the south wing, and the manager of one department cannot open another.
At the bottom sit the individual keys, one for each door or each small group of doors. A member of staff takes the keys for the rooms they use and no more, and a tenant takes the key for their own flat and the shared doors they need. The hotel fire doors guide covers the doors on bedroom corridors and stair cores, where the hierarchy matters most.
Cylinders and keys: the parts that carry the system
The cylinder is the part that must match the leaf it sits in. A TS 007 3-star set, made of a 1-star cylinder with a 2-star handle or escutcheon, keeps the lock proved, and the cylinder should be chosen for the door it guards, not for the key it takes.
A key that can be copied at any shop is a key that cannot be controlled. A restricted keyway, where blanks are held by the supplier and cut only on the order of the person who runs the estate, keeps the copies in known hands. Ask the supplier who holds the blanks and who may order a copy, and put the answer in the file.
Hinges must match the leaf they carry, because a door that sags on its hinges no longer meets its frame, and a lock that no longer meets its keep is a lock that no longer works. Hinges to BS EN 1935 carry the leaf through 200,000 cycles, with grade 13 rated for 120 kg and grade 14 for 160 kg, so the hinge should be chosen for the weight of the leaf it carries.
Key control: the record that names who holds each key
Key control is the record that names who holds each key, and it matters as much as the cylinders. Every key issued should be written down with the name of the person who holds it, the doors it opens and the date it was given out, so the next manager can see who can open which door.
Check the record every month against the keys in hand. A key issued to a member of staff who has left should be written down as returned or lost, and a key that cannot be found should be treated as a key in the wrong hands, because a missing key is a door left open.
Keep the record in one place, with the person who runs the estate. A record kept on a scrap of paper in a drawer is a record that will be lost, and a record that is lost leaves the estate guessing who holds its keys. The fire door inspection checklist names what each round should look for, and the key record should be checked on the same round.
When a key is lost: the change that follows
A lost key is a door left open until the cylinder is changed. First work out which doors the key opened, then change the cylinders on those doors, because a key that is lost cannot be called back. A master key lost is a building of cylinders to change, and that is the cost of holding the key that opens everything.
Change the cylinder, not the whole lock, where the lock allows it. A cylinder swap takes minutes and leaves the hardware in place, while a lock change takes longer and costs more. The new cylinder should be pinned to the same hierarchy, so the keys above it still work and the keys below it still open only their own doors.
Tell the people who hold the keys above and below the lost one what has changed, because a sub-master that no longer opens a door will be tried at the door, and a door that will not open for its own key will be forced. The security door maintenance checklist covers the doors that must hold both fire and forced entry.
Keys beside the access system: cards, fobs and the override
A keyed system and a card system can share the same doors. The card opens the door for the staff who use it every day, and the key opens the door when the card system fails, because a door that will not open when the power goes is a door that holds people inside.
Give the doors a card or a fob where the traffic is heavy, and keep the key for the override. A fob can be stopped the day a member of staff leaves, while a key that walks out with them stays live until the cylinder is changed, and the live fobs should be checked every month. The security turnstiles guide covers readers, fobs and biometrics in the lane.
Escape doors must still release on alarm, whatever the keying says, so no one is held inside when the alarm sounds. Rooms that fill for the evening need panic hardware to BS EN 1125, a bar across at least 60 percent of the leaf width, and the opening force must stay below 30 N for the first 30 degrees of travel and below 22.5 N beyond, under BS 8300 and Approved Document M. The fire door closers guide covers the sizes and the fitting of the closer that pulls the leaf shut.
The handover pack: what the estate keeps on file
The handover pack holds the keying plan, the record of who holds each key, and the pinning chart that shows which key opens which door. Without the chart, a cylinder that needs changing cannot be re-pinned, and without the record, a key that needs stopping cannot be traced.
Keep the pinning chart away from the keys themselves, because a chart left beside the key cabinet is a map of the building for anyone who finds it. The chart belongs in the file with the person who runs the estate, and a copy in the safe with the grand master key.
The pack should also hold the test reports for the doors the keys guard. A fire door only works when it is shut, and a door that must hold fire takes FD30 or FD60 proved to EN 1634-1, with the period following the fire load behind the door. The fire and security doors dual certification guide works through how the two proofs share one leaf, where a door must hold fire and resist attack at once.
The key plan for the whole estate
Put every door on one list before the order goes out, with the key level, the cylinder and the hardware written beside each position, so the door that turns up is the door that was planned. A list that names one key for the whole estate leaves the fitter to guess which cylinder goes where, and a guess is not a plan.
Go through each quote line by line against the list before ordering. A cylinder left off a quote still has to be bought, and fitting it round a door already in use costs more than ordering it with the door. The security door cost factors guide sets out what each step up the scale adds to the build, and the keeping an LPS 1175 rating valid guide sets out what breaks a rating once a door is fitted.
Keep the key record with the doors from the day they arrive, so the proof is never far from the leaf it belongs to. The plant room door requirements guide covers the doors on the rooms that feed a building, and the loading bay doors guide covers the bays where deliveries arrive and leave.
| Key level | Opens | Held by | What to check |
|---|---|---|---|
| Grand master | Every door | Estate manager | Safe, record, chart |
| Sub-master | One floor or wing | Department manager | Record, return on leaving |
| Individual | One door | Member of staff | Record, return on leaving |
| Service | Plant rooms | Contractor, one day | Record, expiry, return |
| Override | Escape doors | Fire service access | Release, panic bar, closer |
A master key system is a hierarchy on paper first, so the keying plan, the cylinders and the record must all sit on the same schedule.
What is a master key system?
A keying hierarchy where one key opens many doors and a staff key opens only the doors its holder needs. The master key opens every door, sub-master keys open one floor or wing, and individual keys open one door.
Who should hold the master key?
One person, the person who runs the estate, and it should be kept in a safe when it is not in use. A master key lost means every cylinder it opened has to be changed.
How are lost keys handled?
Work out which doors the key opened, then change the cylinders on those doors. A cylinder swap takes minutes and leaves the hardware in place, and the new cylinder is pinned to the same hierarchy.
Can keys be copied without permission?
Not where the keyway is restricted. Blanks are held by the supplier and cut only on the order of the person who runs the estate, so the copies stay in known hands.
Do keyed doors still need a fire rating?
Yes, where the door guards an escape route or a compartment wall. The proof is to EN 1634-1, and the period follows the fire load behind the door, FD30 for most rooms and FD60 where the load is heaviest.